• Title/Summary/Keyword: Energy System Simulator

Search Result 320, Processing Time 0.027 seconds

Syngas and Hydrogen Production from $CeO_2/ZrO_2$ coated Foam Devices under Simulated Solar Radiation (다공성 폼에 코팅된 $CeO_2/ZrO_2$ 를 이용한 고온 태양열 합성가스 및 수소 생산 연구)

  • Jang, Jong-Tak;Yoon, Ki-June;Han, Gui-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.260-266
    • /
    • 2012
  • Syngas and hydrogen from the $CeO_2/ZrO_2$ coated foam devices were investigated under simulated solar radiation. The $CeO_2/ZrO_2$ coated SiC, Ni and Cu foam device were prepared using drop-coating method. Syngas production step was performed at $900^{\circ}C$, and hydrogen production process was performed for ten repeated cycles to compare the CeO2 conversion in syngas production step, $H_2$ yield in hydrogen production step and cycle reproducibility. The produced syngas had the $H_2$/CO ratio of 2, which was suitable for methanol synthesis or Fischer-Tropsch synthesis process. In addition, syngas and hydrogen production process is one of the promising chemical pathway for storage and transportation of solar heat by converting solar energy to chemical energy. After ten cycles of redox reaction, the $CeO_2/ZrO_2$ was analyzed using XRD pattern and SEM image in order to characterize the physical and chemical change of metal oxide at the high temperature.

  • PDF

Interior Partitioned Layout and Daylighting Energy Performance in Office Buildings

  • Kim, Gon
    • Architectural research
    • /
    • v.1 no.1
    • /
    • pp.31-40
    • /
    • 1999
  • In this age of "Information", many people consider it a deterrent to information flow to provide a hierarchy with private rooms in a modern office layout. There are others, however, who insist that visual and acoustical privacy are more important than any other design factor in achieving higher productivity. The debate may never end, but the partitioned open plan, which is a new form of the vast open plan, has merits of each concept - open and closed layout. Consequently, office design has dramatically shifted to partitioned open planning, with shorter, temporary walls or partitions, originally intended for increasing privacy and diminishing hierarchy, yet still keeping flexibility in spatial organization. The introduction of low-level partitioned spaces in an office layout, however, produces a complicated lighting design problem. Obviously, accurately predicted daylighting performance data are needed not only for daylighting design but for artificial lighting system design. Scale models of 12 sets of unit partitioned spaces are constructed and extensive scale model measurements of both daylight and reflected sunlight have been performed within an artificial sky simulator. The prototype-building interior is modeled with different partition configurations, each of which is modeled using the different envelope geometry and exterior configurations, and then the variations in interior light levels are estimated. The result indicates that partitioned spaces employed in an open plan of modern offices still offer a large potential for daylighting and energy saving as well. Much of the savings may derive from the cumulative effect of reflected sunlight. Optimal design for building envelope geometry and exterior configuration promises additional savings.

  • PDF

Development of a Unified Research Platform for Plug-In Hybrid Electrical Vehicle Integration Analysis Utilizing the Power Hardware-in-the-Loop Concept

  • Edrington, Chris S.;Vodyakho, Oleg;Hacker, Brian A.
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.471-478
    • /
    • 2011
  • This paper addresses the establishment of a kVA-range plug-in hybrid electrical vehicle (PHEV) integration test platform and associated issues. Advancements in battery and power electronic technology, hybrid vehicles are becoming increasingly dependent on the electrical energy provided by the batteries. Minimal or no support by the internal combustion engine may result in the vehicle being occasionally unable to recharge the batteries during highly dynamic driving that occurs in urban areas. The inability to sustain its own energy source creates a situation where the vehicle must connect to the electrical grid in order to recharge its batteries. The effects of a large penetration of electric vehicles connected into the grid are still relatively unknown. This paper presents a novel methodology that will be utilized to study the effects of PHEV charging at the sub-transmission level. The proposed test platform utilizes the power hardware-in-the-loop (PHIL) concept in conjunction with high-fidelity PHEV energy system simulation models. The battery, in particular, is simulated utilizing a real-time digital simulator ($RTDS^{TM}$) which generates appropriate control commands to a power electronics-based voltage amplifier that interfaces via a LC-LC-type filter to a power grid. In addition, the PHEV impact is evaluated via another power electronic converter controlled through $dSPACE^{TM}$, a rapid control systems prototyping software.

A Study on Safety Assessment of Hydrogen Station (수소충전소의 안전성 평가 연구)

  • PYO, DON-YOUNG;KIM, YANG-HWA;LIM, OCK-TAECK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.6
    • /
    • pp.499-504
    • /
    • 2019
  • Due to the rapid spread and low minimum ignition energy of hydrogen, rupture is highly likely to cause fire, explosion and major accidents. The self-ignition of high-pressure hydrogen is highly likely to ignite immediately when it leaks from an open space, resulting in jet fire. Results of the diffusion and leakage simulation show that jet effect occurs from the leakage source to a certain distance. And at the end of location, the vapor cloud explosion can be occurred due to the formation of hydrogen vapor clouds by built-up. In the result, it is important that depending on the time of ignition, a jet fire or a vapor cloud explosion may occur. Therefore, it is necessary to take into account jet effect by location of leakage source and establish a damage minimizing plan for the possible jet fire or vapor cloud explosion. And it is required to any kind of measurements such as an interlock system to prevent hydrogen leakage or minimize the amount of leakage when detecting leakage of gas.

Fire Simulations for the Abandonment Risk Assessment of Main Control Room Fire in Domestic Nuclear Power Plant (국내 원자력발전소의 주제어실 화재 피난 리스크 평가를 위한 화재 시뮬레이션)

  • Kang, Dae Il;Kim, Kilyoo;Jang, Seung-Cheol;Yoo, Seong Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.199-207
    • /
    • 2014
  • In this paper, to systematically assess the abandonment risk of main control room (MCR) fire, fire simulations with Fire Dynamics Simulator were performed and abandonment probabilities were estimated for the MCR bench-board fire of domestic reference nuclear power plant. The fire simulation scenarios performed in this study included propagating and non-propagating fires of the MCR bench-board, and the availability and unavailability of heating, ventilation, and air conditioning system (HVACS). The following results were obtained. First, temperature was the major abandonment impact factor for the MCR bench-board fire if the HVACS was available and optical density was that if the HVACS was unavailable. Second, the fire scenario contributing the MCR bench-board fire abandonment risk was identified to be only the propagating fire. Third, it was confirmed that the abandonment probability of the MCR bench-board fire for domestic reference nuclear power plant could be reduced by using the fire modeling.

Assessment on Power Quality of Grid-Connected PV System Based on Incremental Conductance MPPT Control (증분컨덕턴스 MPPT제어 기반 계통연계형 태양광발전시스템의 전력품질 평가)

  • Seol, Jae-Woong;Jang, Jae-Jung;Kim, Dong-Min;Lee, Seung-Hyuk;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.8-13
    • /
    • 2007
  • During the last years, there has been an increased interest in the new energy such as photovoltaic(PV) system from the viewpoint of environmental pollution. In this regard, this paper estimates the power quality of grid-connected PV system. As the maximum power operating point(MPOP) of photovoltaic(PV) power systems alters with changing atmospheric conditions, the efficiency of maximum power point tracking(MPPT) is important in PV power systems. Moreover, grid-connected PV system occurs some problems such as voltage inequality and harmonics. Therefore, this paper presents the results of a grid-connected PV system modeling that contains incremental conductance MPPT controller by PSCAD/EMTDC simulator and investigates the influence that can occur in the grid-connected PV system from aspect of power quality, i.e. voltage drop, total harmonic distortion(TDD) and total demand distortion(TDD). For the case study, the measured data of the PV way in Cheongwadae, Seoul, Korea is used.

A Study on the Ballast Control System for Offshore Plant (Offshore Plant용 발라스트 제어 시스템에 관한 연구)

  • Oh, Jin Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2944-2951
    • /
    • 2013
  • Recently, the offshore plant has been revived by rise in oil prices and energy consumption. Due to the external environmental impact, the ballast system is essential for an offshore plant. The ballast system for the existing offshore plant, consist of pump 6EA and Ballast tank 4EA, is performed by the tilt control. However, this system is vulnerable to a failure due to the fact that a lot of equipment needs to be installed within the system. In this paper, a new concept of ballast system and the control algorithm based on IT is proposed. Simulator has been created to test the proposed system and algorithm, and as a result, it has proven that it is controlled stably.

Analysis of operation performance of PHILS-based superconducting current limiter connected to MVDC system

  • Seok-Ju Lee;Jae In Lee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.54-59
    • /
    • 2023
  • In this paper, we analyze experimental results by applying the PHILS model to a lab-scale superconducting current limiter system for its actual application in medium-voltage direct current (MVDC) systems. Superconducting current limiters exhibit effective current-limiting performance in circuit breaker operations, particularly in limiting large fault currents within a short period, addressing the challenges posed by the increasing use of renewable energy and the integration of DC medium-voltage distribution systems. The development of such superconducting current limiters faces various technical and cost disadvantages, especially when applying a medium-voltage 35kV level system, which is intended for future introduction. The proven lab-scale superconducting current limiter system and the PHILS model are combined and integrated into the actual system. Our plan involves analyzing the limiter's performance, assessing its impact on the system, and preparing for its application in future medium-voltage systems. Utilizing RTDS, a simulation was conducted by connecting actual scaled-down equipment and systems, with the analysis results presented.

A Study on the Efficiency Improvement of Glazing Panel with DSC Modules (염료감응형 태양전지를 적용한 유리 패널의 효율 향상에 관한 연구)

  • Jang, Han-Bin;Kang, Jun-Gu;Lee, Sang-Gil;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.35-41
    • /
    • 2013
  • Dye-sensitized solar cell (DSC) allows light transmission and the application of various colors that make it especially suitable for building-integrated PV (BIPV) application. In order to apply DSC module into windows, it has to be panelized: DSC module should be protected with reinforced glass to the entire surface. Up to date, it seems to be common to make double glazing with DSC modules with air gaps between the glasses and the DSC modules. Few research has been conducted on the characteristics of various glazing types with DSC modules. This study aims to analyze the electrical performance of DSC modules according to panelizing method for glazing unit with DSC modules. The prototype of the DSC glazing that applied silicone filler between DSC modules and glasses was developed. The electrical performances of this type of DSC glazing with the filler and rather conventional double glazing with DSC modules were compared. Their performances were measured using a solar simulator that is suitable for DSC performance testing. The results indicated that the electrical performance of the filler type DSC glazing improved by 7% compared to that of the conventional DSC double glazing type.

Measurement of inconvenience, human errors, and mental workload of simulated nuclear power plant control operations

  • Oh, I.S.;Sim, B.S.;Lee, H.C.;Lee, D.H.
    • Proceedings of the ESK Conference
    • /
    • 1996.10a
    • /
    • pp.47-55
    • /
    • 1996
  • This study developed a comprehensive and easily applicable nuclear reactor control system evaluation method using reactor operators behavioral and mental workload database. A proposed control panel design cycle consists of the 5 steps: (1) finding out inconvenient, erroneous, and mentally stressful factors for the proposed design through evaluative experiments, (2) drafting improved design alternatives considering detective factors found out in the step (1), (3) comparative experiements for the design alternatives, (4) selecting a best design alternative, (5) returning to the step (1) and repeating the design cycle. Reactor operators behavioral and mental workload database collected from evaluative experiments in the step (1) and comparative experiments in the step (3) of the design cycle have a key roll in finding out defective factors and yielding the criteria for selection of the proposed reactor control systems. The behavioral database was designed to include the major informations about reactor operators' control behaviors: beginning time of operations, involved displays, classification of observational behaviors, dehaviors, decisions, involved control devices, classification of control behaviors, communications, emotional status, opinions for man-machine interface, and system event log. The database for mental workload scored from various physiological variables-EEG, EOG, ECG, and respir- ation pattern-was developed to indicate the most stressful situation during reactor control operations and to give hints for defective design factors. An experimental test for the evaluation method applied to the Compact Nuclear Simulator (CNS) installed in Korea Atomic Energy Research Institute (KAERI) suggested that some defective design factors of analog indicators should be improved and that automatization of power control to a target level would give relaxation to the subject operators in stressful situation.

  • PDF