• Title/Summary/Keyword: Energy Production Facility

Search Result 141, Processing Time 0.027 seconds

Safety Assessments for the IS(Iodine Sulfur) Process in a Hydrogen Production Facility (수소생산시설에서의 요오드-황 공정에 대한 안전성 평가연구)

  • Lee, Hyon-Woo;Jae, Moo-Sung;Cho, Nam-Chul;Yang, Jon-Eon;Lee, Won-Jae
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.54-58
    • /
    • 2009
  • A substitute energy development has been required due to the exhaust of the fossil fuel and an environmental problem. Consequently, possible technologies producing hydrogen from water that does not release carbon is a very promising technology. Also, Iodine-Sulfur(IS) thermochemical water decomposition is one of the promising processes that are used to produce hydrogen efficiently using the high temperature gas-cooled reactor(HTGR) as an energy source that is possible to supply heat over 900$^{\circ}C$. In this study, to make a initiating events identification for the IS process, Master Logic Diagram(MLD) is used and 9 initiating events that cause a leakage of the chemical material are identified. Also, 6 events are identified among 9 initiating events above and are quantified using event tree.

Safety Evaluation of a Radioisotope Transport Package (방사성 동위원소 운반용기의 안전성 평가)

  • Lee, J.C.;Ku, J.H.;Seo, K.S.;Min, D.K.
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.251-261
    • /
    • 1997
  • A package to transport the high level radioactive materials is required to withstand the hypothetical accident conditions as well as normal transport conditions according to IAEA standards and domestic regulations. The regulations require that the package should maintain the shielding, thermal and structural integrities to release no radioactive material. In general, safety evaluation of packages is performed by experimental methods using scale model and/or analytical methods using computer codes. This paper presents the safety evaluation of package to transport the radioisotopes produced in the HANARO to the radioisotope production facility. Radiation shielding, thermal and structural analyses were peformed using the computer codes. It has been verified that the package is safe under hypothetical accident conditions as well as normal transport conditions.

  • PDF

Economic Feasibility of Forest Biomass Thermal Energy Facility Using Real Option Approach (실물옵션법을 이용한 산림 바이오매스 열공급 시설의 투자 분석)

  • An, Hyunjin;Min, Kyungtaek
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.3
    • /
    • pp.453-461
    • /
    • 2021
  • The energy use of forest biomass is crucial to deal with climate change and achieve the carbon-neutral goal. This study aims to analyze the economic feasibility of forest biomass thermal energy facilities and calculate the optimal subsidy level of heat supply to ensure continued operation of the facilities. To achieve this aim, the net present value approach (NPV) and call option price model are adopted considering wood chip price volatilities. The Forest Energy Self-Sufficient Village Project financed by Korea Forest Service is considered as the research case study. In our analysis, when 50% of the initial investment is given to the subsidies and RECs are applied to only power generation, NPV and IRR are both negative and the investment value using the real option model is also zero. We concluded that some heat subsidies should be acknowledged to keep the facilities operating. Besides, the simulation results reveal reliable economic values when the heating subsidy is priced at KRW 0.0248 per kcal.

Optimization Process Models of Gas Combined Cycle CHP Using Renewable Energy Hybrid System in Industrial Complex (산업단지 내 CHP Hybrid System 최적화 모델에 관한 연구)

  • Oh, Kwang Min;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.65-79
    • /
    • 2019
  • The study attempted to estimate the optimal facility capacity by combining renewable energy sources that can be connected with gas CHP in industrial complexes. In particular, we reviewed industrial complexes subject to energy use plan from 2013 to 2016. Although the regional designation was excluded, Sejong industrial complex, which has a fuel usage of 38 thousand TOE annually and a high heat density of $92.6Gcal/km^2{\cdot}h$, was selected for research. And we analyzed the optimal operation model of CHP Hybrid System linking fuel cell and photovoltaic power generation using HOMER Pro, a renewable energy hybrid system economic analysis program. In addition, in order to improve the reliability of the research by analyzing not only the heat demand but also the heat demand patterns for the dominant sectors in the thermal energy, the main supply energy source of CHP, the economic benefits were added to compare the relative benefits. As a result, the total indirect heat demand of Sejong industrial complex under construction was 378,282 Gcal per year, of which paper industry accounted for 77.7%, which is 293,754 Gcal per year. For the entire industrial complex indirect heat demand, a single CHP has an optimal capacity of 30,000 kW. In this case, CHP shares 275,707 Gcal and 72.8% of heat production, while peak load boiler PLB shares 103,240 Gcal and 27.2%. In the CHP, fuel cell, and photovoltaic combinations, the optimum capacity is 30,000 kW, 5,000 kW, and 1,980 kW, respectively. At this time, CHP shared 275,940 Gcal, 72.8%, fuel cell 12,390 Gcal, 3.3%, and PLB 90,620 Gcal, 23.9%. The CHP capacity was not reduced because an uneconomical alternative was found that required excessive operation of the PLB for insufficient heat production resulting from the CHP capacity reduction. On the other hand, in terms of indirect heat demand for the paper industry, which is the dominant industry, the optimal capacity of CHP, fuel cell, and photovoltaic combination is 25,000 kW, 5,000 kW, and 2,000 kW. The heat production was analyzed to be CHP 225,053 Gcal, 76.5%, fuel cell 11,215 Gcal, 3.8%, PLB 58,012 Gcal, 19.7%. However, the economic analysis results of the current electricity market and gas market confirm that the return on investment is impossible. However, we confirmed that the CHP Hybrid System, which combines CHP, fuel cell, and solar power, can improve management conditions of about KRW 9.3 billion annually for a single CHP system.

Management Methods of Bone Mineral Density Examination Using Dual Energy X-ray Absorptiometry (이중에너지 엑스선 흡광분석법을 이용한 골밀도검사의 관리법)

  • Kim, Ho-Sung;Kim, Tae-Hyung;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.351-360
    • /
    • 2018
  • In recent years, demand for examination of bone mineral density (BMD) is increasing in Korea according aging society. Therefore, it is required to develop an efficient management program that can increase the safety and reliability of Dual Energy X-ray Absorptiometry (DXA) that can be applied to the criteria of the World Health Organization. It is necessary to develop a management program that can design a program to improve the accuracy and precision of the results of the analysis and to improve the accuracy of diagnosis of osteoporosis by development a high quality DXA report. It is recommended to prepare the examination manuals and to establish procedures of standard operating including the program to prevent the pitfalls during the examination, the compatibility evaluation of the examination data, and the contents of the radiation safety. In addition, relevant regulations on the production of high-quality DXA reports are required and government and related agencies should introduce individual and facility recognition programs through DXA measurement and education programs and training. It is considered that efforts should be made to prepare high quality DXA report by guidelines on all aspects of BMD for preparation about aging society.

Development of Summer Leaf Vegetable Crop Energy Model for Rooftop Greenhouse (옥상온실에서의 여름철 엽채류 작물에너지 교환 모델 개발)

  • Cho, Jeong-Hwa;Lee, In-Bok;Lee, Sang-Yeon;Kim, Jun-Gyu;Decano, Cristina;Choi, Young-Bae;Lee, Min-Hyung;Jeong, Hyo-Hyeog;Jeong, Deuk-Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.246-254
    • /
    • 2022
  • Domestic facility agriculture grows rapidly, such as modernization and large-scale. And the production scale increases significantly compared to the area, accounting for about 60% of the total agricultural production. Greenhouses require energy input to create an appropriate environment for stable mass production throughout the year, but the energy load per unit area is large because of low insulation properties. Through the rooftop greenhouse, one of the types of urban agriculture, energy that is not discarded or utilized in the building can be used in the rooftop greenhouse. And the cooling and heating load of the building can be reduced through optimal greenhouse operation. Dynamic energy analysis for various environmental conditions should be preceded for efficient operation of rooftop greenhouses, and about 40% of the solar energy introduced in the greenhouse is energy exchange for crops, so it should be considered essential. A major analysis is needed for each sensible heat and latent heat load by leaf surface temperature and evapotranspiration, dominant in energy flow. Therefore, an experiment was conducted in a rooftop greenhouse located at the Korea Institute of Machinery and Materials to analyze the energy exchange according to the growth stage of crops. A micro-meteorological and nutrient solution environment and growth survey were conducted around the crops. Finally, a regression model of leaf temperature and evapotranspiration according to the growth stage of leafy vegetables was developed, and using this, the dynamic energy model of the rooftop greenhouse considering heat transfer between crops and the surrounding air can be analyzed.

A Study on the Sea Water DTEC Power Generation System of the FPSO (FPSO의 온배수를 활용한 해수 DTEC 발전시스템에 대한 연구)

  • Song, Young-Uk
    • Journal of Navigation and Port Research
    • /
    • v.42 no.1
    • /
    • pp.9-16
    • /
    • 2018
  • The development of limited petroleum resources for use with mankind inevitably explores and seeks to develop oil fields in the deep sea area, under the rise of the oil prices market situation. The use of Oceanic Thermal Energy Conversion (OTEC) technology, which operates the power generation facility using the temperature differences between the deep water and the surface water, is progressing actively as a trend to follow. In this study, the application of the Discharged Thermal Energy Conversion (DTEC) was designed and analyzed under the condition that the supply condition of seawater used in the FPSO installed in the deep sea area is changed up to 400m depth. In this case, it was confirmed that the design of the system that can generate more electric power according to the depth of water is confirmed, by thus applying the DTEC system by taking the cooling water at a deeper water depth than the existing design water depth. The FPSO considers the similarity of the OTEC power generation facilities, and will apply the DTEC system to FPSO in the deep sea area to accumulate technology and the conversion to further utilize the OTEC power generation facilities after the end of life cycle of oil production, which could be a solution to two important issues, namely, resource development and sustainable development.

Production and Fuel Properties of Wood Chips from Logging Residues by Timber Harvesting Methods (목재수확 방법에 따른 벌채부산물 목재칩의 생산 및 연료 특성)

  • Choi, Yun-Sung;Jeong, In-Seon;Cho, Min-Jae;Mun, Ho-Seong;Oh, Jae-Heun
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.2
    • /
    • pp.217-232
    • /
    • 2021
  • This study calculated the productivity and cost of extraction and processing of logging residues by cut-to-length (CTL) and whole-tree (WT) harvesting methods. In addition, the comparative analysis of the characteristics of wood chip fuel to examine whether it was suitable for the fuel conditions of the energy facility. In the harvesting and processing system to produce the wood chips of logging residues the system productivity and cost of the CTL harvesting system were 1.6 Gwt/SMH and 89,865 won/Gwt, respectively. The productivity and cost of the WT harvesting system were 2.9 Gwt/SMH and 72,974 won/Gwt, respectively. The WT harvesting productivity increased 1.3times while harvesting cost decreased by 18.7% compared to the CTL harvesting system. The logging residues of wood chips were not suitable for CTL wood chips based on International Organization for Standardization (ISO 17225-4:2021) and South Korea standard (NIFoS, 2020), but the quality (A2, Second class) was improved through screening operation. The WT-unscreened wood chips conformed to NIFoS standard (second class) and did not conform to ISO but were improved through screening operation (Second class). In addition to the energy facility in plant A, all wood chips except CTL-unscreened wood chips were available through drying processing. The WT-unscreened wood chips were the lowest at 99,408 won/Gwt. Plants B, C, and D had higher moisture content than plant A, so WT-unscreened wood chips without drying processing were the lowest at 57,204 won/Gwt. Therefore, the production of logging residues should improve with operation methods that improve the quality of wood chips required for applying the variable biomass and energy facility.

Operation Characteristics of Coal Syngas Production and DME Conversion Facilities (석탄 합성가스 제조 및 화학원료(DME) 전환설비의 운전 특성)

  • Chung, Seok-Woo;Kim, Mun-Hyun;Lee, Seung-Jong;Yun, Yong-Seung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.83-86
    • /
    • 2006
  • In this study, the syngas producing facility that consists of pulverized coal feeding/gasification and hot gas clean-up system was tested for Indonesian subbituminous coal. And the DME conversion facilities have been developed and tested for converting syngas to DME by reactions with catalysts. So, the entrained-bed slagging type pi lot scale coal gasifier was operated normally in the temperature range of $1,400{\sim}1,450^{\circ}C,\;7{\sim}8kg/cm^2$ pressure. And Roto middle coal produced syngas that has a composition of $36{\sim}38%$ CO, $14{\sim}16%\;H_2,\;and\;5{\sim}8%\;CO_2$. Particulates in syngas were 99.8% removed by metal filters. $H_2S$ composition in syngas was also desulfurized by the Fe chelate system to yield less than 0.1 ppm level. When the clean syngas $70{\sim}100 Nm^3/h$ was provided to DME conversion rector, normally operated in the temperature range of $230{\sim}250^{\circ}C$ and $60kg/cm^2$ pressure, 4.5% DME was yielded.

  • PDF

Technical Development of Environment Control Complex of Micro-climatic Factors for Oyster Mushroom Cultivated in Protected Environment (복합 환경제어형 새송이 버섯 시설재배의 기술개발)

  • Suh, Won-Myung;Yoon, Yong-Cheol;Kim, Woong-Gyu
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.121-124
    • /
    • 2002
  • King Oyster(Pleurotus eryngii) is one of the most promising mushrooms produced on the domestic farms. The quality as well as quantity of King oyster is sensitively affected by micro climate factors such as temperature, relative humidity, $CO_2$ concentration, and light intensity. To safely produce high-quality King oysters year round, it is required that the environmental factors be carefully controlled by well designed structures equipped with various facilities and control systems. In this study, we are focusing on carrying out growing experiment to find out reasonable range of each environmental factor together with economic and safe structures influencing on the optimal productivity of king oyster mushroom. The optimal productivity will be evaluated by considering the quality and quantity of mushroom production, energy requirements, facility construction and management cost, etc.

  • PDF