• 제목/요약/키워드: Energy Dynamics

검색결과 1,635건 처리시간 0.032초

Application of Cluster Distributions to Energy Transfer in Two-Dimensional Choleic Acid Crystals

  • 박치헌;송추윤;우희권;최용국;국성근
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권7호
    • /
    • pp.630-634
    • /
    • 1995
  • The cluster distributions for different concentrations of 1,4-dibromonaphthalene (DBN) in 4,4'-dibromobenzophenone (DBBP)/1,4-dibromonaphthalene (DBN) choleic acid were determined by a computer simulation in order to model the energy transfer dynamics. The results of the simulation indicate that long range interaction between molecules further apart than nearest does not occur and energy transfer efficiency is restricted by single range interaction. The results also demonstrate that the trapping is diffusion limited. The energy transfer rate is reduced by a factor of 15 in DBBP/DBN choleic acid realtive to that in DBBP/DBN doped into polystyrene due to the larger distance between molecules.

경쟁체제 하에서의 발전소 건설 시스템 다이내믹스 모델 개발 (Development of System Dynamics model for Electric Power Plant Construction in a Competitive Market)

  • 안남성
    • 한국시스템다이내믹스연구
    • /
    • 제2권2호
    • /
    • pp.25-40
    • /
    • 2001
  • This paper describes the forecast of power plant construction in a competitive korean electricity market. In Korea, KEPCO (Korea Electric Power Corporation, fully controlled by government) was responsible for from the production of the electricity to the sale of electricity to customer. However, the generation part is separated from KEPCO and six generation companies were established for whole sale competition from April 1st, 2001. The generation companies consist of five fossil power companies and one nuclear power company in Korea at present time. Fossil power companies are scheduled to be sold to private companies including foreign investors. Nuclear power company is owned and controlled by government. The competition in generation market will start from 2003. ISO (Independence System Operator will purchase the electricity from the power exchange market. The market price is determined by the SMP(System Marginal Price) which is decided by the balance between demand and supply of electricity in power exchange market. Under this uncertain circumstance, the energy policy planners such as government are interested to the construction of the power plant in the future. These interests are accelerated due to the recent shortage of electricity supply in California. In the competitive market, investors are no longer interested in the investment for the capital intensive, long lead time generating technologies such as nuclear and coal plants. Large unclear and coal plants were no longer the top choices. Instead, investors in the competitive market are interested in smaller, more efficient, cheaper, cleaner technologies such as CCGT(Combined Cycle Gas Turbine). Electricity is treated as commodity in the competitive market. The investors behavior in the commodity market shows that the new investment decision is made when the market price exceeds the sum of capital cost and variable cost of the new facility and the existing facility utilization depends on the marginal cost of the facility. This investors behavior can be applied to the new investments for the power plant. Under these postulations, there is the potential for power plant construction to appear in waves causing alternating periods of over and under supply of electricity like commodity production or real estate production. A computer model was developed to sturdy the possibility that construction will appear in waves of boom and bust in Korean electricity market. This model was constructed using System Dynamics method pioneered by Forrester(MIT, 1961) and explained in recent text by Sternman (Business Dynamics, MIT, 2000) and the recent work by Andrew Ford(Energy Policy, 1999). This model was designed based on the Energy Policy results(Ford, 1999) with parameters for loads and resources in Korea. This Korea Market Model was developed and tested in a small scale project to demonstrate the usefulness of the System Dynamics approach. Korea electricity market is isolated and not allowed to import electricity from outsides. In this model, the base load such as unclear and large coal power plant are assumed to be user specified investment and only CCGT is selected for new investment by investors in the market. This model may be used to learn if government investment in new unclear plants could compensate for the unstable actions of private developers. This model can be used to test the policy focused on the role of unclear investments over time. This model also can be used to test whether the future power plant construction can meet the government targets for the mix of generating resources and to test whether to maintain stable price in the spot market.

  • PDF

Numerical simulations of a horizontal axis water turbine designed for underwater mooring platforms

  • Tian, Wenlong;Song, Baowei;VanZwieten, James H.;Pyakurel, Parakram;Li, Yanjun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권1호
    • /
    • pp.73-82
    • /
    • 2016
  • In order to extend the operational life of Underwater Moored Platforms (UMPs), a horizontal axis water turbine is designed to supply energy for the UMPs. The turbine, equipped with controllable blades, can be opened to generate power and charge the UMPs in moored state. Three-dimensional Computational Fluid Dynamics (CFD) simulations are performed to study the characteristics of power, thrust and the wake of the turbine. Particularly, the effect of the installation position of the turbine is considered. Simulations are based on the Reynolds Averaged Navier-Stokes (RANS) equations and the shear stress transport ${\kappa}-{\omega}$ turbulent model is utilized. The numerical method is validated using existing experimental data. The simulation results show that this turbine has a maximum power coefficient of 0.327 when the turbine is installed near the tail of the UMP. The flow structure near the blade and in the wake are also discussed.

추사피중에서 자동조타로써 항행하는 선박의 추진에너지 손실량 평가에 관한 연구 (A Study on Prediction of Propulsive Energy Loss Related to Automatic Steering of Ships in Following Seas)

  • 이경우;손경호
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1996년도 The Korean Institute of Navigation 1996년도 춘계학술발표회 논문집
    • /
    • pp.77-92
    • /
    • 1996
  • When an automatic course-keeping is concerned as is quite popular in modern navigation the closed-loop steering system consists of autopilot device power unit (or telemotor unit) steering gear magnetic or gyro compass and ship dynamics. The consideration of irregular disturbances to ship dyanmics and a few non-linear mechanisms involved in the system inevitably or artificially are known to be very important in properly evaluating or analyzing the automatic steering system. In the present study the mathematical model of each element of an automatic steering system is derived which takes account of a fex non-linear mechanisms. PD(Proportional-Derivative) controller and low-pass filter with a weather adjustment are adopted to modelling the characteristics of an autopilot. The calculation method of imposing irregular disturbances to ship dynamics is proposed where irregular disturbances implying irregular wave and the fluctuating component of wind. For he evaluation of automatic steering system of ships in the open seas an important term "performance index" is introduced from the viewpoint of energy saving which derived from the concept of energy loss on ship propulsion. Finally the present methods are applied to two typical types of ship ; an ore carrier and a fishing boat. The various effects of linear and/or non-linear control constants of autopilot on propulsive energy loss are investigated to validate and clarify the present smulation technique.

  • PDF

전산유체역학을 이용한 소듐-소듐 열교환기 설계코드의 검증 (VALIDATION OF A DESIGN CODE FOR SODIUM-TO-SODIUM HEAT EXCHANGERS BY UTILIZING COMPUTATIONAL FLUID DYNAMICS)

  • 김대희;어재혁;이태호
    • 한국전산유체공학회지
    • /
    • 제21권1호
    • /
    • pp.19-29
    • /
    • 2016
  • A Prototype Gen-IV Sodium-cooled Fast Reactor which is one of the $4^{th}$ generation nuclear reactors is in development by Korea Atomic Energy Research Institute. The reactor is composed of four main fluid systems which are categorized by its functions, i.e., Primary Heat Transport System, Intermediate Heat Transport System, Decay Heat Removal System and Sodium-Water Reaction Pressure Relief System. The coolant of the reactor is liquid sodium and sodium-to-sodium heat exchangers are installed at the interfaces between two fluid systems, Intermediate Heat Exchangers between the Primary Heat Transport System and the Intermediate Heat Transport System and Decay Heat Exchangers between the Primary Heat Transport System and the Decay Heat Removal System. For the design and performance analysis of the Intermediate Heat Exchanger and the Decay Heat Exchanger, a computer code was written during previous step of research. In this work, the computer code named "SHXSA" has been validated preliminarily by computational fluid dynamics simulations.

이산화탄소 분리를 위한 Pd-Ag 분리막 공정의 CFD 모사 (CFD Simulation of Pd-Ag Membrane Process for $CO_2$ Separation)

  • 오민;박준용;노승효;홍성욱
    • 공업화학
    • /
    • 제20권1호
    • /
    • pp.104-108
    • /
    • 2009
  • 본 연구에서는 이산화탄소/수소 혼합기체가 관 모양의 Pd-Ag 막을 통과할 때 관 안에서의 이산화탄소 및 수소의 몰분율, 수소 분압, 그리고, 속도 구배 등을 CFD (Computational Fluid Dynamics) 기법을 사용하여서 다양한 유입 속도에 대해서 모사하였다. 모사 결과에 의하면 유입 속도가 증가할수록 관의 길이 방향을 따라서 이산화탄소의 몰분율이 더디게 증가함을 알 수 있었다. 또한, 혼합 기체의 유입 속도와 관의 길이가 수소 회수율에 미치는 영향에 대해서 살펴보았으며 낮은 유입속도와 긴 관의 경우에 수소 회수율이 큰 것을 알 수 있었다.

극저온 선형 팽창기용 리드밸브의 기하학적 형상변화에 따른 유동 특성 연구 (A Study on the Flow Characteristics of Reed Valve with Variable Geometric Variations for Cryogenic Linear Expander)

  • 정은아;김지우;염한길;윤소남
    • 드라이브 ㆍ 컨트롤
    • /
    • 제12권4호
    • /
    • pp.48-53
    • /
    • 2015
  • This paper deals with the flow characteristics of a reed valve analyzed using computational dynamics(CFD) for optimal design. The seat sizes of the valve are modeled asØ6[mm] and Ø8[mm] to compare the flow characteristics. The inlet boundary condition is entered at 10[kPa], 15[kPa], 20[kPa], and 30[kPa] and the outlet boundary condition is set to the atmospheric pressure. The flow coefficient(C) and pressure loss coefficient(K) are calculated from the results of flow analysis. From the analysis results, it was confirmed that the flow coefficient of a reed valve having a seat size of Ø6[mm] is greater than that having a seat size of Ø8[mm], and the coefficient of pressure loss of a valve with a seat size of Ø6[mm] is lower than the Ø8[mm] size valve.

Performance evaluation of sea water heat exchanger installed in the submerged bottom-structure of floating architecture

  • Sim, Young-Hoon;Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권10호
    • /
    • pp.1062-1067
    • /
    • 2015
  • Floating architecture is a type of building that is geographically located on a sea or a river. It floats under the influence of buoyancy, and does not have an engine for moving it. Korea is a peninsula surrounded by sea except on the north side, so floating architectures have been mainly focused on two points: solving the issue of small territory and providing various leisure & cultural spaces. Floating architectures are expected to save energy effectively, if they use sea water heat, which is known to be clean energy with infinite reserves. To use sea water heat as the heat source and/or heat sink, this study proposes a model in which a sea water heat exchanger is embedded in the concrete structure in the lower part of the floating architecture that is submerged under the sea. Based on the results of performance evaluations of the sea water heat exchanger using CFD (computational fluid dynamics) analysis and mock-up experiments under various conditions, it is found out that the temperature difference between the inlet and outlet of the heat exchanger is in the range of $3.06{\sim}9.57^{\circ}C$, and that the quantity of heat transfer measured is in the range of 3,812~7,180 W. The CFD evaluation results shows a difference of 5% with respect to the results of mock-up experiment.

Diagnostics of nuclear reactor coolant pump in transition process on performance and vortex dynamics under station blackout accident

  • Ye, Daoxing;Lai, Xide;Luo, Yimin;Liu, Anlin
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2183-2195
    • /
    • 2020
  • A mathematical model for the flowrate and rotation speed of RCP during idling was established. The numerical calculation method and dimensionless method were used to analyze the flow, head, torque and pressure and speed changes under idle conditions. Regularity, using the Q criterion vortex identification judgment method combined with surface flow spectrum morphology analysis to diagnose the vortex dynamic characteristics on RCP blade. On impeller blade, there is two oscillations in the pressure ratio on pressure surface in blade outlet region. The velocity on the suction surface is two times more oscillating than the inlet of blade, and there is an intersection with the velocity ratio curve on pressure surface. On blade of guide vane, the pressure ratio increases along the inlet to outlet direction, and the speed ratio decreases with the increase of idle time. There is a vortex that rotates counterclockwise on the suction surface, and the streamline on the suction surface of blade is subjected to the entrainment and blocking action of the vortex creates a large reverse flow in the main flow region. There are two vortices at the outlet of guide vane suction side and the vortices are in opposite directions.

극저온 고압액체수소 공급용 인쇄기판 열교환기의 열설계에 관한 연구 (A Study on Thermal Design of Printed Circuit Heat Exchanger for Supply of Cryogenic High Pressure Liquid Hydrogen)

  • 손상호;최병일
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.347-355
    • /
    • 2021
  • This paper is a study on the thermal design of printed circuit heat exchanger (PCHE) to supply cryogenic high pressure liquid hydrogen stored from hydrogen liquefaction process by using computational fluid dynamics (CFD). This PCHE should be thermally designed to raise the temperature of cryogenic liquid hydrogen to a desired temperature and also to be anti-icing to avoid any local freezing in hot channel. This research presents the effect of inlet velocity and inlet temperature of hydrogen, and the effect of flow configurations of co/counter-flow on thermal design of PCHE heat exchanger based on various CFD simulation analysis.