• 제목/요약/키워드: Energy Detector

검색결과 899건 처리시간 0.025초

Basic characterization of uranium by high-resolution gamma spectroscopy

  • Choi, Hee-Dong;Kim, Junhyuck
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.929-936
    • /
    • 2018
  • A basic characterization of uranium samples was performed using gamma- and X-ray spectroscopy. The studied uranium samples were eight types of certified reference materials with $^{235}U$ enrichments in the range of 1-97%, and the measurements were performed over 24 h using a high-resolution and high-purity planar germanium detector. A general peak analysis of the spectrum and the $XK_{\alpha}$ region of the uranium spectra was carried out by using HyperGam and HyperGam-U, respectively. The standard reference sources were used to calibrate the spectroscopy system. To obtain the absolute detection efficiency, an effective solid angle code, EXVol, was run for each sample. Hence, the peak activities and isotopic activities were determined, and then, the total U content and $^{234}U$, $^{235}U$, and $^{238}U$ isotopic contents were determined and compared with those of the certified reference values. A new method to determine the model age based on the ratio of the activities of $^{223}Ra$ and $^{235}U$ in the sample was studied, and the model age was compared with the known true age. In summary, the present study developed a method for basic characterization of uranium samples by nondestructive gamma-ray spectrometry in 24 h and to obtain information on the sample age.

Determination of some useful radiation interaction parameters for waste foods

  • Akman, F.;Gecibesler, I.H.;Sayyed, M.I.;Tijani, S.A.;Tufekci, A.R.;Demirtas, I.
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.944-949
    • /
    • 2018
  • The mass attenuation coefficients (${\mu}/{\rho}$) of food waste samples (pomegranate peel, acorn cap, lemon peel, mandarin peel, pumpkin peel, grape peel, orange peel, pineapple peel, acorn peel and grape stalk) have been measured employing a Si(Li) detector at 13.92, 17.75, 20.78, 26.34 and 59.54 keV. Also, the theoretical values of the mass attenuation coefficients have been evaluated utilizing mixture rule from WinXCOM program. The results showed that the lemon peel has the highest values of ${\mu}/{\rho}$ among the selected samples. From the obtained mass attenuation coefficients, we determined some absorption parameters such as effective atomic number ($Z_{eff}$), electron density ($N_E$) and molar extinction coefficient (${\varepsilon}$). It was found that the $Z_{eff}$ values of all food wastes lie within the range of 4.034-7.595, whereas the $N_E$ of the studied food wastes was found to be in the range of $0.301-1.720{\times}10^{25}$ (electrons/g) for present energy region.

Collective Excitations in Thin K Films on Al(111)

  • Kim, Bong-Ok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.137-137
    • /
    • 2000
  • The surface collective modes of thin K films deposited on Al(111) have been investigated using frequency dependent photoyield measurements and momentum resolved inelastic electron scattering. Jellium based theoretical calculations have predicted a richer set of features in the thin films than for the surface of a semi-infinite solid because there are th interference between two interfaces (substrate-film and film-vacuum) and heavy damping on the substrate. The use of an optical probe and electron scattering has allowed us to draw a more complete picture of the dynamic screening in thin films. The number, dispersion, damping and optical activity of the collective modes of the thin films have been measured as a function of K film thickness. New overlayer-induced excitations are observed : At qII=0, they correspond to the antisymmetric slab mode and the multipole surface plasmon. At finite qII=0, these modes undergo a transition towards the K multipole and monopole surface plasmons. With increasing coverage, the overlayer excitations turn into the collective modes of semi-infinite K. For a consistent interpretation of photoyield and electron energy loss spectra it is crucial to account for the non-analytic dispersion of the overlayer modes at small parallel wave vectors and for the finite angular resolution of the detector. The observed dispersions confirm predictions based on the time-dependent density functional approach.

  • PDF

Optimal Strategies for Cooperative Spectrum Sensing in Multiple Cross-over Cognitive Radio Networks

  • Hu, Hang;Xu, Youyun;Liu, Zhiwen;Li, Ning;Zhang, Hang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제6권12호
    • /
    • pp.3061-3080
    • /
    • 2012
  • To improve the sensing performance, cooperation among secondary users can be utilized to collect space diversity. In this paper, we focus on the optimization of cooperative spectrum sensing in which multiple cognitive users efficiently cooperate to achieve superior detection accuracy with minimum sensing error probability in multiple cross-over cognitive radio networks. The analysis focuses on two fusion strategies: soft information fusion and hard information fusion. Under soft information fusion, the optimal threshold of the energy detector is derived in both noncooperative single-user and cooperative multiuser sensing scenarios. Under hard information fusion, the optimal randomized rule and the optimal decision threshold are derived according to the rule of minimum sensing error (MSE). MSE rule shows better performance on improving the final false alarm and detection probability simultaneously. By simulations, our proposed strategy optimizes the sensing performance for each cognitive user which is randomly distributed in the multiple cross-over cognitive radio networks.

방사능 존재확인과 정량분석시 최적화된 측정시간의 결정을 위한 계측전략 (Counting Strategies in Radioactivity Measurement for the Monitoring and Screening)

  • 서경원
    • Journal of Radiation Protection and Research
    • /
    • 제23권2호
    • /
    • pp.65-74
    • /
    • 1998
  • 저 준위방사능 계측에서 가장 기본적으로 요구되는 것이 최적 측정시간의 결정이다. 최적화된 계측전략으로 측정시간을 결정하기 위하여 측정시간을 고정하는 방법, 측정값을 고정하는 방법, 시료와 자연계수율 또는 기준준위를 비교하여 측정하는 방법을 비교 검토하는 결정식을 도출하였다. 이 계측전략에서 기기에 주어진 측정조건 즉, 검출기의 효율, 측정기의 용량, 측정기의 최대 및 평균 자연계수율과 관련기준 즉, 기준준위, 검출한계 등을 만족하는 측정시간이 결정된다. 계측전략은 측정시 주어진 조건에서 방사능 존재확인과 정량분석에 대한 시료의 최적 측정시간의 결정을 편리하게 함으로써 일상의 저준위방사능 측정에 유용하게 사용될 것이다.

  • PDF

레이저빔을 이용한 펄스변조 적외선탐색기 기만 (Laser-based Jamming of a Pulse Modulated Infrared Seeker)

  • 김성재;정춘식;신용산
    • 한국군사과학기술학회지
    • /
    • 제22권2호
    • /
    • pp.179-188
    • /
    • 2019
  • Laser beam is directional and small in divergence angle so that it is well qualified to deliver high intensity infrared energy into a coming MANPADS threat for aircraft survivability. The threat will be deceived and loose tracking of a target when it is exposed to the laser beam modulated relevant to the track mechanism of the threat. The laser beam goes through scattering inside the seeker of the threat and reach the detector in a stray light form, which is a critical phenomenon enabling jamming of the seeker. The mechanism of the laser beam based jamming against a pulse modulated infrared seeker is shown. Simulations are carried out to support the understanding of how the jam technique works.

최대 리아프노프 지수를 활용한 전력계통 측정 데이터 기반 비선형 동요 현상 검출 방안 (MLE Based Power System Oscillation Detector by Using Measurement Data)

  • 조환희;이병준;남수철;김용학
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권2호
    • /
    • pp.55-61
    • /
    • 2018
  • 본 연구는 시각 동기 위상 측정 정보를 이용하여 전력계통에 나타나는 여러 가지 동요 현상을 검출하기 위한 기초 연구로써, 시계열 데이터 분석 분야로 분류된다. 제시한 방법은 비선형 동특성에 해석 기반으로 접근하여 전력계통에 나타날 수 있는 여러 동요 현상을 범용적으로 검출해 낼 수 있다. 비선형 동요 현상의 신호적 패턴을 수학적으로 기본 순시치 파형으로부터 피크치 샘플링을 통해 전개하여 계통 요소간 간섭으로 인한 원하지 않는 진동 모드를 검출하고자 한다. 계통의 변화로 진동 모드가 나타날 때, 2차원 평면에 실효치로 환산한 시계열 전압 데이터와 선형화된 플로퀘트 상수(Floquet multiplier)를 맵핑하여 도시하고, 정상상태 지점으로부터 거리를 계산하여 최대 리아프노프 지수 계산을 통해 계통이 불안정하게 되는 시간을 시계열 데이터 분석으로 추정하는 것이 본 방법의 핵심이다. 이러한 접근으로 제시한 비선형 동요 검출 알고리즘을 적용하여 디지털 필터 적용 또는 주파수 영역 해석과 같은 오프라인 Study와 달리 온라인으로 신속하게 계통의 현재 상태를 알 수 있게 된다.

High sensitivity determination of iridium contents in ultra-basic rocks by INAA with coincidence gamma-ray detection

  • Ebihara, Mitsuru;Shirai, Naoki;Kuwayama, Jin;Toh, Yosuke
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.423-428
    • /
    • 2022
  • Very low contents (in the range of 10-9 g/g) of Ir in mantle-derived rock samples (komatiites) were non-destructively determined by INAA coupled with coincidence gamma-ray spectrometry using 16 Ge detectors. Aliquots of the same samples were analyzed by NiS fire-assay ICP-MS for Ir and other platinum group elements. Because the INAA procedure used in this study is non-destructive and is almost free from spectral interference in gamma-ray spectrometry, the INAA values of Ir contents obtained in this study can be highly reliable. Iridium values obtained by ICP-MS were consistent with the INAA values, implying that the ICP-MS values of Ir obtained in this study are equally reliable. Under the present experimental conditions, detection limits were estimated to be 1 pg/g, which corresponds to 0.1 pg for a sample mass of 0.1 g. These levels can be even lowered by an order of magnitude, if necessary, which cannot be achieved by ICP-MS carried out in this study.

Implementation of waste silicate glass into composition of ordinary cement for radiation shielding applications

  • Eid, Mohanad S.;Bondouk, I.I.;Saleh, Hosam M.;Omar, Khaled M.;Sayyed, M.I.;El-Khatib, Ahmed M.;Elsafi, Mohamed
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1456-1463
    • /
    • 2022
  • The aim of this work is to study the radiation shielding properties of cement samples with waste glass incortated into its composition. The mass attenuation coefficient (MAC) of the samples were experimentally determined to evaluate their radiation shielding ability. The experimental coefficient was evaluated using NaI detector for gamma energies between 59.53 keV and 1408.01 keV using different radioactive point sources Am-241, Eu-152, Co-60, and Cs-137, and the gamma transmission parameters half-value layer, mean free path, and transmission factor were calculated. The theoretical coefficient of the composites was determined using Geant4 and XCOM software. The results were also compared against Geant4 and XCOM simulations by calculating the relative deviation between the values to determine the accuracy of the results. In addition the mechanical properties (including Compressive and porosity) as well as the thermogravimetric analysis were tested for the present samples. Overall, it was concluded that the cement sample with 50% waste glass has the greatest shielding potential for radiation shielding applications and is a useful way to reuse waste glass.

사례 분석을 통한 IoT 기반 화재탐지시스템의 화재 감지신호 특성 (A Case Study of the Characteristics of Fire-Detection Signals of IoT-based Fire-Detection System)

  • 박승환;김두현;김성철
    • 한국안전학회지
    • /
    • 제37권3호
    • /
    • pp.16-23
    • /
    • 2022
  • This study aims to provide a fundamental material for identifying fire and no-fire signals using the detection signal characteristics of IoT-based fire-detection systems. Unlike analog automatic fire-detection equipment, IoT-based fire-detection systems employ wireless digital communication and are connected to a server. If a detection signal exceeds a threshold value, the measured values are saved to a server within seconds. This study was conducted with the detection data saved from seven fire accidents that took place in traditional markets from 2020 to 2021, in addition to 233 fire alarm data that have been saved in the K institute from 2016 to 2020. The saved values demonstrated variable and continuous VC-Signals. Additionally, we discovered that the detection signals of two fire accidents in the K institution had a VC-Signal. In the 233 fire alarms that took place over the span of 5 years, 31% of smoke alarms and 30% of temperature alarms demonstrated a VC-Signal. Therefore, if we selectively recognize VC-Signals as fire signals, we can reduce about 70% of false alarms.