• 제목/요약/키워드: Energy Converting

검색결과 275건 처리시간 0.022초

Terfenol-D를 이용한 선형 자기변형 구동기의 설계 및 특성 연구 (A Study on Design and Characteristics of Linear Magnetostrictive Actuator Using Terfenol-D)

  • 임채욱;정태영;문석준;김병현
    • 한국소음진동공학회논문집
    • /
    • 제13권4호
    • /
    • pp.308-316
    • /
    • 2003
  • Terfenol-D is one of magnetostrictive materials which have the property of converting the energy in magnetic fields into mechanical movement and vice versa. We designed and fabricated a linear magnetostrictive actuator using Terfenol-D. It has 25 mm diameter and 100 mm long. To grasp the characteristics of it, a series of tests were performed in the range of 50 Hz below. Induced-strain actuation displacements of the actuator measured by test and predicted by magnetic analysis agreed well. And blocked forces according to the input currents were estimated from the testing results. Modelling method representing the exerting force of a linear magnetostrictive actuator was confirmed through some testing results.

A Study on Repowering of Domestic Aged Coal-fired Power Plant

  • Baek, SeHyun;Kim, YoungJoo;Kim, HyunHee;Park, SangBin;Jang, JiHoon
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권1호
    • /
    • pp.35-39
    • /
    • 2017
  • Recently, the public opinion is growing that the main cause of greenhouse gas, fine dust and nitrogen oxide, sulfuric acid emission is coal-fired power plant, and now the decommission or conversion to other clean fuel is being demanded. However, it is a huge national loss to decommission coal-fired power plant with remaining life, and also simple fuel converting to natural gas will lead to drastic rise on power generating cost. Therefore, this study aims to provide the analysis result about the reduction effect of $CO_2$, environment emission, and to influence to power plant performance and facilities when repowering with adding gas turbine is applied to domestic aged coal-fired power plant.

가정용 직류 플랫폼 설계 (DC Platform Design for Home Application)

  • 한상수
    • 한국정보통신학회논문지
    • /
    • 제15권9호
    • /
    • pp.1979-1984
    • /
    • 2011
  • 본 논문은 가정내 주 배전시스템으로 DC 전력을 사용하기 위한 그린 Platform을 제시하였다. 제안한 Platform은 공통 DC bus와 양방향 DC 그리드를 갖는 구조이며 DC bus에 연결된 장비들은 에너지원(source), 부하(load), 양방향 장비(bi-directional devices)로 구분하였다. 현재의 기술을 바탕으로 전압과 시스템을 DC로 변환하고 부하에 직접 연결 시킴으로서 시스템 효율을 증가시키기 위한 구축 방법을 제시하였다.

Analysis of the Virtual Power Plant Model Based on the Use of Emergency Generators in South Korea

  • Chung, Beom Jin;Kim, Chang Seob;Son, Sung-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.38-46
    • /
    • 2016
  • This study analyzes the economic efficiency of the virtual power plant (VPP) model that aims to integrate a number of emergency generators installed at the consumer end and operate them as a single power plant. Several factors such as the demand response benefits from VPP operation and costs incurred for converting emergency generators into VPP are considered to assess the economic efficiency of the proposed VPP model. Scenarios for yearly VPP conversion are prepared based on the installed capacities of the emergency generators distributed in South Korea, while the costs and benefits are calculated from the viewpoints of participants and power companies in accordance with California Test Methods. Furthermore, a sensitivity analysis is conducted on the cost factors among those affecting the economic efficiency of VPP business because these two factors have a great impact on benefits.

Terfenol-D를 이용한 선형 자기변형 구동기의 설계 및 특성 연구 (A Study on Design and Characteristics of Linear Magnetostrictive Actuator Using Terfenol-D)

  • 임채욱;정태영;문석준;김병헌
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.17-24
    • /
    • 2002
  • Terfenol-D is one of magnetostrictive materials which have the property of converting the energy in magnetic fields into mechanical movement and vice versa. We designed and fabricated a linear magnetostrictive actuator using Terfenol-D. It has 25mm diameter and 100mm long. To grasp the characteristics of it, n series of tests were performed in the range of 50Hz below. Induced-strain actuation displacements of the actuator measured by test and predicted by magnetic analysis agreed well. And blocked forces according to the input currents were estimated from the testing results. Modelling method representing the exerting force of a linear magnetostrictive actuator was confirmed through some testing results.

  • PDF

이동 격자를 이용한 Power Steering용 Vane Pump 유동 해석 (Numerical Simulation of a Vane Pump Characteristics of an Automotive Power Steering System Using Moving Mesh Technique)

  • 이상혁;허남건;진봉용
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.459-462
    • /
    • 2006
  • In this study, the characteristic of a vane pump of an automative power steering system is numerically analyzed. The vane pump changes the energy level of operation fluid by converting mechanical input power to hydraulic output. To simulate this mechanism, moving mesh technique is adopted. As a result, the flow rate and pressure are obtained by numerical analysis. The flow rate agrees well with the experimental data. Moreover, the variation and oscillation of the pressure around the rotating vane are confirmed. The difference of pressure appears in the vane tip as a result of the flow characteristics. Furthermore, the back flow into the rotor was observed.

  • PDF

집광추적형 PV발전의 특성에 관한 연구 (Characteristics of Photovoltaic Power Generation by Concentration and Tracking)

  • 김봉래;박상규;오현경;유영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.39-40
    • /
    • 2005
  • Photovoltaic Power Generation system occupies an important position as an alternative energy source, converting directly sunlight into electricity,using a photovoltaic cell. The Purpose of this research is to present and confirm the effectiveness of concentration and tracking of sun in photovoltaic power generation. Comparative experiments were carried outwith two rating 75 watt solar modules in $25^{\circ}$ under condition of various times concentration, tracking and plain normal measuring generated voltages, currents and temperatures of back sheet of modules by internet monitoring system to find out which is best in economic sense. The experiments show that output power of concentration and tracking photovoltaic power generation is over 180% more then that of plain normal system.

  • PDF

저압 증발기를 갖는 청수제조 장치에 관한 실험적 연구 (Experimental Study on Fresh Water Generation System with Low Pressure Evaporation)

  • 정한식;위보워;이경환;신용한;정효민
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.25-30
    • /
    • 2011
  • A fresh water generation system is designed for converting brackish water or seawater into fresh water. In this paper fresh water generation by distillation process that evaporates feed water and subsequently condenses vapor as evaporation product to get fresh water was studied and city water was employed as feed water. The system uses the ejector to create a vacuum, under which liquid can be evaporated at lower temperature than it at normal or atmospheric condition, hence less energy consumption. The effect of various operating conditions i.e. temperature of feed water and different orifice diameters were studied experimentally to investigate the characteristic of the system. It was found that these parameters have significant effect in the performance of fresh water generation system with low pressure evaporation.

Terfenol-D를 이용한 선형 자기변형 구동기의 설계 및 특성 연구 (A Study on Design and Characteristics of Linear Magneto-strictive Actuator Using Terfenol-D)

  • Lim, Chae-Wook;Chung, Tae-Young;Moon, Seok-Jun;Kim, Byung-Hyun
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.310.2-310
    • /
    • 2002
  • Terfenol-D is one of magnetostrictive materials which have the property of converting the energy in magnetic fields into mechanical movement and vice versa. We designed and fabricated a linear magnetostrictive actuator using Terfenol-D. It has 25mm diameter and 100mm long. To grasp the characteristics of it, a series of tests were performed in the range of 50㎐ below. Induced-strain actuation displacements of the actuator measured by test and predicted by magnetic analysis agreed well. (omitted)

  • PDF

10kW급 지붕재용 태양전지모듈 실증연구 (Demonstration Study of 10kW Poly Metal Panel integrated PV Module)

  • 이소미;노지희;주만식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.246-249
    • /
    • 2007
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are sol id state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre- manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. So, this paper describes a design and performance test of the 10kW poly metal pv module(pmpp) system. It is concluded that the prediction of BIPV system's performance should be based on the more accurate PV module installation.

  • PDF