• 제목/요약/키워드: Energy Control

검색결과 9,894건 처리시간 0.043초

Output control of solar cells using PWM chopper (PWM chopper 에 의한 태양전지의 출력제어)

  • Yu, Gwon-Jong;Kim, Yong-Sik;Park, I-Jun;Song, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.401-404
    • /
    • 1990
  • A new control method of solar cell output using PWM chopper is described. Theoretical analysis and comparision for all sorts of system are also discussed for improving photovoltic system efficiency. It is expected that the result of this study will be utilized to some other DC or AC application equipments.

  • PDF

Attitude Control of a Vehicle under the Disturbances by Sliding Mode Controller with Reaction Jets

  • Son, Sung-Han;Kim, Jinsu;Park, Kang-Bak;Teruo Tsuji;Tsuyoshi Hanamoto
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.166.6-166
    • /
    • 2001
  • An attitude control of an air vehicle based on the variable structure control is proposed. For an air vehicle, minimum weight is required. Thus, it is desired to reduce the input energy. The optimal state portrait curve using time-varying sliding surface is proposed to reduce the control energy. Tracking performance of the closed loop system is guaranteed under the existence of parameter variation and external disturbances.

  • PDF

An experimental study on the optimal control algorithm for central heating system (중앙난방 시스템의 최적제어 알고리즘의 적용을 위한 실험적 연구)

  • Ahn, Byung-Cheon;Chun, Won-Ik
    • Proceedings of the SAREK Conference
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.463-468
    • /
    • 2005
  • An experimental study on the optimal control algorithm for central heating system for minimizing energy consumption while maintaining the comfort of indoor thermal en vironment in terms of the environmental variables such as loads and weather. experimental study has been done by one using the prototype of central heating system. As a result the optimal control algorithm shows good energy performance in comparison with conventional control one.

  • PDF

Change of performance, serum metabolite, and carcass characteristics on high energy diet of Hanwoo steers

  • Jang, Sun Sik;Yang, Seung Hak;Lee, Eun Mi;Kang, Dong Hun;Park, Bo Hye;Kim, Hye Jae;Kwon, Eung Gi;Chung, Ki Yong
    • Korean Journal of Agricultural Science
    • /
    • 제43권5호
    • /
    • pp.810-817
    • /
    • 2016
  • The aim of this experiment was to determine the effect of a high-energy diet on the level of serum metabolites and on carcass characteristics of Hanwoo steers. High energy diets have been used for enhancing intramuscular adipose tissue in high quality beef cattle. However, there is not much information about the physiological reactions to this diet. We hypothesized that a high energy diet would increase blood metabolites and the meat quality of Hanwoo steers during the early and final fattening periods. A $2{\times}2$ factorial arrangement (High, Control, and Early, Final) in a completely randomized design was used to feed 24 Hanwoo steers. Two steers were kept in the same pen and 12 pens were used for the experiment. Blood was drawn from each steer on the first week of every other month from 11 to 28 months. Overall Average Daily Gain (ADG) and feed efficiency were not different between high energy and control diets (p > 0.05). However, Dry Matter Intake (DMI greater with the control diet than DMI with the high energy diet during the final fattening period (p < 0.05). Serum non-esterified fatty acid (NEFA) concentrations were greater in the control diet group than in the high energy diet group during the final fattening period (p < 0.05). However, serum albumin, glucose, total protein, triglyceride, and phosphorus were greater in the high energy group than those of the control group (p < 0.05). Carcass traits or physico-chemical characteristics were not different between high energy diet treatment and the control. These data indicated that a high energy diet (+ 3% TDN) increased serum triglyceride during early fattening periods and decreased non-esterified fatty acids during final fattening periods in Hanwoo steers.

Cost savings for paper machines with automation solution packages (초지기 자동화 해법에 의한 운전비용 절감대책)

  • Sorsa, Jukka
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 한국펄프종이공학회 2007년도 제32회 펄프종이기술 국제세미나
    • /
    • pp.83-125
    • /
    • 2007
  • Increasing energy costs have caused profitability problems for paper suppliers. Therefore unprofitable lines are being closed down. The actions aiming for improved profits are focused either on cost savings or on increasing the capacity of the remaining machines. The runnability of a paper machine and its total efficiency have a significant effect on energy consumption. Producing one ton of waste paper consumes at least as much energy as producing the same amount of sellable end product. New automation solutions enable significant cost-effective improvements to the total efficiency of a line without large investment projects. The measures focus on minimizing changes, interruptions, interruption recovery times and grade change times. Newest actuators, online quality measurements and wet end analysators create an improvement potential, which can be optimally implemented with the latest machine direction control solutions, based on model predictive control concepts. Equally, drying management is significant to the energy consumption. The newest control strategies optimize the use of various drying actuators for different situations; either by responding to changes as efficiently as possible or by using only the cheapest energy sources in stable situations. An even steam supply, which is vital for paper machines, is achieved with control for the power plant steam network. This makes possible to avoid the delays upon starting the paper machine and assure an even steam supply for the drying section and the actuators. This document describes means which have brought significant energy and raw material savings for paper machines. Metso Automation has provided efficiency improvement packages, which are usually based on optimized control of dry weight and drying in all running conditions. The solutions are based on performance analysis, on which the estimations for improvement potential and the necessary actions are based on. Typically benefits on an annual level have been from hundreds of thousands of euros to over one million euro. For example, variations in dry weight have been decreased more than 50%. The results are presented with a few examples. Additionally, the analysis models, adjustment solutions and the changes in running methods with which the results were achieved, are presented.

  • PDF

Energy-efficient Relay MAC with Dynamic Power Control in Wireless Body Area Networks

  • Cai, Xuelian;Yuan, Jingjing;Yuan, Xiaoming;Zhu, Wu;Li, Jiandong;Li, Changle;Ullah, Sana
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권7호
    • /
    • pp.1547-1568
    • /
    • 2013
  • Wireless body area network (WBAN) is an emerging short-range wireless communication network with sensor nodes located on, in or around the human body for healthcare, entertainment and ubiquitous computing. In WBANs, energy is severely constrained which is the prime consideration in the medium access control (MAC) protocol design. In this paper, we propose a novel MAC protocol named Energy-efficient Relay MAC with dynamic Power Control (ERPC-MAC) to save energy consumption. Without relying on the additional devices, ERPC-MAC employs relaying nodes to provide relay service for nodes which consume energy fast. Accordingly the superframe adjustment is performed and then the network topology can be smoothly switched from single-hop to multi-hop. Moreover, for further energy saving and reliability improvement, the dynamic power control is introduced to adjust the power level whenever a node transmits its packets to the coordinator or the relaying node. To the best of the authors' knowledge, this is the first effort to integrate relay, topology adjustment and power control to improve the network performance in a WBAN. Comprehensive simulations are conducted to evaluate the performance. The results show that the ERPC-MAC is more superior to the existing standard and significantly prolongs the network lifetime.

Fault Detection Sensitivity of a Data-driven Empirical Model for the Nuclear Power Plant Instruments (데이터 기반 경험적 모델의 원전 계측기 고장검출 민감도 평가)

  • Hur, Seop;Kim, Jae-Hwan;Kim, Jung-Taek;Oh, In-Sock;Park, Jae-Chang;Kim, Chang-Hwoi
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제65권5호
    • /
    • pp.836-842
    • /
    • 2016
  • When an accident occurs in the nuclear power plant, the faulted information might mislead to the high possibility of aggravating the accident. At the Fukushima accident, the operators misunderstood that there was no core exposure despite in the processing of core damage, because the instrument information of the reactor water level was provided to the operators optimistically other than the actual situation. Thus, this misunderstanding actually caused to much confusions on the rapid countermeasure on the accident, and then resulted in multiplying the accident propagation. It is necessary to be equipped with the function that informs operators the status of instrument integrity in real time. If plant operators verify that the instruments are working properly during accident conditions, they are able to make a decision more safely. In this study, we have performed various tests for the fault detection sensitivity of an data-driven empirical model to review the usability of the model in the accident conditions. The test was performed by using simulation data from the compact nuclear simulator that is numerically simulated to PWR type nuclear power plant. As a result of the test, the proposed model has shown good performance for detecting the specified instrument faults during normal plant conditions. Although the instrument fault detection sensitivity during plant accident conditions is lower than that during normal condition, the data-drive empirical model can be detected an instrument fault during early stage of plant accidents.

Maximum Power Point Tracking Control Scheme for Grid Connected Variable Speed Wind Driven Self-Excited Induction Generator

  • El-Sousy Fayez F. M.;Orabi Mohamed;Godah Hatem
    • Journal of Power Electronics
    • /
    • 제6권1호
    • /
    • pp.52-66
    • /
    • 2006
  • This paper proposes a wind energy conversion system connected to a grid using a self-excited induction generator (SEIG) based on the maximum power point tracking (MPPT) control scheme. The induction generator (IG) is controlled by the MPPT below the base speed and the maximum energy can be captured from the wind turbine. Therefore, the stator currents of the IG are optimally controlled using the indirect field orientation control (IFOC) according to the generator speed in order to maximize the generated power from the wind turbine. The SEIG feeds a (CRPWM) converter which regulates the DC-link voltage at a constant value where the speed of the IG is varied. Based on the IG d-q axes dynamic model in the synchronous reference frame at field orientation, high-performance synchronous current controllers with satisfactory performance are designed and analyzed. Utilizing these current controllers and IFOC, a fast dynamic response and low current harmonic distortion are attained. The regulated DC-link voltage feeds a grid connected CRPWM inverter. By using the virtual flux orientation control and the synchronous frame current regulators for the grid connected CRPWM inverter, a fast current response, low harmonic distortion and unity power factor are achieved. The complete system has been simulated with different wind velocities. The simulation results are presented to illustrate the effectiveness of the proposed MPPT control scheme for a wind energy system. In the simulation results, the d-q axes current controllers and DC-link voltage controller give prominent dynamic response in command tracking and load regulation characteristics.

The Energy Absorption Control Characteristics of Al Thin-walled Tubes for Crashworthiness Enhancement (충돌성능 향상을 위한 Al 박육부재의 에너지흡수 제어특성)

  • Yang, Yong-Jun;Kim, Sun-Kyu;Yang, In-Young;Sim, Jae-Ki
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제16권4호
    • /
    • pp.81-87
    • /
    • 2008
  • In this study, concerns the crashworthiness of the widely used vehicle structure, square thin-walled tubes, which are excellent on the point of the energy absorbing capacity. An experimental investigation was carried out to study the energy absorption characteristics of thin-walled square tubes subjected to dynamic crushing by axial loading to develop the optimum structural members. The impact velocity was tested in the rage $4.698{\sim}8.2m/s$. To efficiently review the collapse characteristics of these sections, the simulation have been carried out using explicit FEM package, LS-DYNA. The solutions compared with results the impact collapse experiment. Here, the controller are introduced to improve and control the absorbed energy of thin-walled square tubes in this paper. To predict and control the energy absorption, we designed it in consideration to the it's influence, height, thickness, wide ratio in this study. When the controller used, the experimental results of crushing of square tubes controlled by the controller's elements showed a good candidate for a controllable energy absorption capability in impact axial crushing.

LED color control using Arduino and Human motion sensors (아두이노와 인체감지 센서를 이용한 LED 컬러 제어)

  • Kim, Sang Ki;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • 제9권2호
    • /
    • pp.69-73
    • /
    • 2014
  • Recent interest in the worldwide energy to increase, and energy savings of the energy for effective operation of the IT technology there is a demand. By using a low-power LED energy efficient energy use worldwide for a variety of studies have been conducted. In Korea, 20-30% of the domestic electricity consumption corresponding to the illumination in order to conserve energy used by various sensors associated with illumination control studies are underway. That is the next generation of energy began to pay attention to the LED light source, LED and Arduino In this paper, an ultrasonic sensor to control and want to maximize the energy efficiency of the management. Paper, the user is directly operating the separate controller that controls the LED light, instead of being recognized through human body detection LED light on / off to control the experiment and study verified. In this paper, we develop an interface that also allows them to maximize the efficiency of energy management and efficiency, accompanied by expansion of commercialization can be achieved.