A Study on Savings Analysis of Light Dimming Control System Using the Daylight based on Photovoltaic Power Generation (태양광발전 기반의 주광을 활용한 조명제어 시스템의 에너지 절감량 분석 연구)

  • Ham, Won-Tae;Jang, Cheol-Yong;Jeong, Hak-Guen
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.11-21
    • /
    • 2012
  • In the normal office building, the energy consumption to maintain the reasonable intensity of illumination for the work by using the artificial illumination occupies 30% or greater of the whole building electric energy consumption. If the dependability of the artificial illumination is dropt by positively using the natural lighting from the outside, the large amount of electrical energy can be saved, in addition the more nice visual environment for work can be created. Daylight is lighting source that most closely match visual response of the human, because sunlight and skylight achieve the harmony. For this reason, the daylight of small amount than amount of the artificial lighting source also can give the same effect in work activities of human. In addition, if there is daylight at the window of the building, the energy can be saved by controlling the artificial lighting. In this paper, in the building using the photovoltaic power generation analyze the correlation between the amount of energy generated by photovoltaic and indoor illumination and this was proved through the simulation with Relux 2010. In addition, the amount of daylight inflow in the room and distribution was drawn by the equation and the ratio for the sectional dimming control of each lighting equipment was predicted and the energy saving amount according to this was calculated. As a result, the indoor illumination was satisfied with recommended illumination value of the office and consumption power could be reduced approximately with 20~70%.

Modeling of a Compressed Air Energy Electrification by Using Induction Generator Based on Field Oriented Control Principle

  • Vongmanee, Varin;Monyakul, Veerapol
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1511-1519
    • /
    • 2014
  • The objective of this paper is to propose a modelling of a small compressed air energy storage system, which drives an induction generator based on a field-oriented control (FOC) principle for a renewable power generation. The proposed system is a hybrid technology of energy storage and electrification, which is developed to use as a small scale of renewable energy power plant. The energy will be transferred from the renewable energy resource to the compressed air energy by reciprocating air compressor to be stored in a pressurized vessel. The energy storage system uses a small compressed air energy storage system, developed as a small unit and installed above ground to avoid site limitation as same as the conventional CAES does. Therefore, it is suitable to be placed at any location. The system is operated in low pressure not more than 15 bar, so, it easy to available component in country and inexpensive. The power generation uses a variable speed induction generator (IG). The relationship of pressure and air flow of the compressed air, which varies continuously during the discharge of compressed air to drive the generator, is considered as a control command. As a result, the generator generates power in wide speed range. Unlike the conventional CAES that used gas turbine, this system does not have any combustion units. Thus, the system does not burn fuel and exhaust pollution. This paper expresses the modelling, thermodynamic analysis simulation and experiment to obtain the characteristic and performance of a new concept of a small compressed air energy storage power plant, which can be helpful in system designing of renewable energy electrification. The system was tested under a range of expansion pressure ratios in order to determine its characteristics and performance. The efficiency of expansion air of 49.34% is calculated, while the efficiency of generator of 60.85% is examined. The overall efficiency of system of approximately 30% is also investigated.

The Effect of Atrium on Energy Conservation and Environmental Control of a Building (아트리움의 에너지 절약(節約)과 환경조절기능(環境調節機能)에 관한 연구(硏究))

  • Lee, Eon-Gu;Lee, Hyeon-Ho
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.5-11
    • /
    • 1993
  • The study, considering the fact that most of the recently built atrium buildings do not fulfill their capacity of energy conservation and environmental control, aims to develop design strategies for architects in designing atrium buildings in terms of energy/environment standpoint. The research includes case studies of existing atrium buildings, quantatative analysis of energy performance for atrium buildings and systematic investigation of various aspects of atrium regarding its function of thermal, luminous and acoustical control of a building. The result of the study may contribute to the considerable reduction of energy consumption as well as to improvement of overall building environment.

  • PDF

Simulation study on one-step ahead control of a photovoltaic energy storage system

  • Sugisaka, Masanori;Kuroiwa, Kenzo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.741-746
    • /
    • 1987
  • Solar cell which transforms the light energy into the electric energy from Sun comes into prominence as a new energy for next generation. However, it is difficult to obtain the stable output voltage and current from the solar cell due to the uncertainty in weather conditions, etc, In the present paper, two types of control laws are considered for regulating the input voltage in a photovoltaic energy storage system such as the system with the super conducting magnetic energy storage. (1) Oone is the design of optimal controller. (2) The other is that of weighted minimum prediction error controllers (weighted one-step ahead controllers). Simulation study for the above controllers is performed to see how they work and to get preliminary knowledge in the regulation of the input voltage to the experimental photovoltaic energy storage system.

  • PDF

Development of Simulation Model Based Optimal Start and Stop Control Daily Strategy (시뮬레이션 모델기반 냉난방 설비 일별 최적 기동/정지 제어기법 개발)

  • Lee, Chanwoo;Koo, Junemo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.1
    • /
    • pp.16-21
    • /
    • 2018
  • This work aims to develop a platform to investigate the effect of operation schedules on the building energy consumption and to derive a simulation model based optimal start and stop daily strategy. An open-source building energy simulation tool DOE2 is used for the engine, and the developed simulation model is validated using ASHRAE guideline 14. The effect of late-start/early-stop operation of HVAC system on the daily building energy consumption was analyzed using the developed simulation model. It was found that about 10% of energy consumption cut was possible using the control strategy for an hour of advance of the stop operation, and about 3% per an hour of delay of the start operation.

Energy Regenerative Damper Applied to the Railway Vehicle (철도차량의 현가장치로서 에너지 재생 댐퍼 이용에 대한 고찰)

  • Kim Sang-Soo;Park Chun-Soo;Mok Jin-Yong;Seo Sung-Il;Lee Tae-Hyung;Kim Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.375-380
    • /
    • 2004
  • Vibration of railway vehicle has harmful effect to dynamic performances of railway represented to stability, safety and ride comfort. Hence reduction of vibration has been discussed as an important problem and has been widely investigated. A new technology of vibration control, energy regenerative control, is introduced. Energy regenerative damper using this new vibration control converts vibration energy into other kind of energy that we can utilize. In this paper, this energy regenerative damper is applied to the dynamic absorber and vehicle suspension. And it is evaluated whether the energy regenerative railway vehicle suspension is possible.

  • PDF

AN ANALYSIS OF TECHNICAL SECURITY CONTROL REQUIREMENTS FOR DIGITAL I&C SYSTEMS IN NUCLEAR POWER PLANTS

  • Song, Jae-Gu;Lee, Jung-Woon;Park, Gee-Yong;Kwon, Kee-Choon;Lee, Dong-Young;Lee, Cheol-Kwon
    • Nuclear Engineering and Technology
    • /
    • v.45 no.5
    • /
    • pp.637-652
    • /
    • 2013
  • Instrumentation and control systems in nuclear power plants have been digitalized for the purpose of maintenance and precise operation. This digitalization, however, brings out issues related to cyber security. In the most recent past, international standard organizations, regulatory institutes, and research institutes have performed a number of studies addressing these systems cyber security.. In order to provide information helpful to the system designers in their application of cyber security for the systems, this paper presents methods and considerations to define attack vectors in a target system, to review and select the requirements in the Regulatory Guide 5.71, and to integrate the results to identify applicable technical security control requirements. In this study, attack vectors are analyzed through the vulnerability analyses and penetration tests with a simplified safety system, and the elements of critical digital assets acting as attack vectors are identified. Among the security control requirements listed in Appendices B and C to Regulatory Guide 5.71, those that should be implemented into the systems are selected and classified in groups of technical security control requirements using the results of the attack vector analysis. For the attack vector elements of critical digital assets, all the technical security control requirements are evaluated to determine whether they are applicable and effective, and considerations in this evaluation are also discussed. The technical security control requirements in three important categories of access control, monitoring and logging, and encryption are derived and grouped according to the elements of attack vectors as results for the sample safety system.

Infrared and visible image fusion based on Laplacian pyramid and generative adversarial network

  • Wang, Juan;Ke, Cong;Wu, Minghu;Liu, Min;Zeng, Chunyan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.5
    • /
    • pp.1761-1777
    • /
    • 2021
  • An image with infrared features and visible details is obtained by processing infrared and visible images. In this paper, a fusion method based on Laplacian pyramid and generative adversarial network is proposed to obtain high quality fusion images, termed as Laplacian-GAN. Firstly, the base and detail layers are obtained by decomposing the source images. Secondly, we utilize the Laplacian pyramid-based method to fuse these base layers to obtain more information of the base layer. Thirdly, the detail part is fused by a generative adversarial network. In addition, generative adversarial network avoids the manual design complicated fusion rules. Finally, the fused base layer and fused detail layer are reconstructed to obtain the fused image. Experimental results demonstrate that the proposed method can obtain state-of-the-art fusion performance in both visual quality and objective assessment. In terms of visual observation, the fusion image obtained by Laplacian-GAN algorithm in this paper is clearer in detail. At the same time, in the six metrics of MI, AG, EI, MS_SSIM, Qabf and SCD, the algorithm presented in this paper has improved by 0.62%, 7.10%, 14.53%, 12.18%, 34.33% and 12.23%, respectively, compared with the best of the other three algorithms.

Energy Cost Saving Control of Water Reuse Pumping System Using Particle Swarm Optimization (PSO를 이용한 물 재이용 펌프시스템의 에너지 비용 제어)

  • Boo, Chang-Jin;Kim, Ho-Chan;Kang, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.860-867
    • /
    • 2015
  • This paper presents a control method for energy cost saving in the water reuse pumping system. An optimize horizon switching strategy is proposed to implement an pump control. And Particle Swarm Optimization (PSO) algorithm is used to solve optimal problems in each time step. Energy costs are calculated for electricity on both TOU in the light, heavy, and maximum load time period and peak charges. The control method in water reuse pumping systems is determined to reduce the TOU cost. The simulation results show a energy cost saving for water reuse pumping systems.

A New Design of Wave Energy Generator Using Hydrostatic Transmission (정유압 구동식 변속기를 사용한 새로운 파력 발전기 설계)

  • Ahn, Kyoungkwan;Dinh, Quangtruong;Yoon, Jongil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.171-171
    • /
    • 2010
  • An innovative design of a floating-buoy wave energy converter (WEC) using hydrostatic transmission (HST), named HSTWEC, is presented in this paper. The system is designed to convert ocean wave fluctuation into electricity by using the HST circuit and an electric generator. Based on the floating-buoy concept, the wave forces the sub-buoy to move up and down. Consequently, the electric power can be obtained from the generator in both the moving directions of the sub-buoy through the HST circuit as shown in Fig. 1. In order to investigate the HSTWEC operations, a mathematical model of the system is indispensible. In addition, the method to control the HSTWEC, including: pump displacement control, tension adjustment control and ballast weight control, is also discussed in this paper. Finally, the design concept as well as simulation results indicated that this HSTWEC design is an effective solution and possible to fabricate for wave energy generation.

  • PDF