• 제목/요약/키워드: Energy Control

검색결과 9,852건 처리시간 0.047초

Control of Booster Output Voltage in Fuel Cell Power Plant (연료전지발전용 부스터의 출력전압제어 연구)

  • Han, Soo-Bin;Jung, Bong-Man;Shin, Dong-Ryul;Choi, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1038-1040
    • /
    • 1992
  • Booster is used widely as one of the step-up DC/DC power converter in power conversion process for fuel cell power plant which have the electrical characteristic of the high current density and low cell voltage. In view of control system, booster can be unstable when it is operated in broad operation range because the transfer function of booster has zero in right half plane of s-domain. So for reliable operation, controller must make the system stable in whole working range. In this paper, the two control method such as digital PID control and fuzzy control is studied for booster output voltage regulation in fuel cell plant. The design procedure of PID control and fuzzy control is described. And the experiment of designed controller action is performed in various operation points for controller performance test.

  • PDF

Energy Performance Evaluation of VAV System through Various Operating Strategies in Office Buildings (VAV 시스템의 현장 운전방식에 따른 에너지 성능평가)

  • 서종욱;허정호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제16권2호
    • /
    • pp.184-193
    • /
    • 2004
  • The purpose of this study is to evaluate the performance of various control strategies in commercial buildings which have been operated by the variable air volume (VAV) system. Two buildings in Seoul were chosen for the field study. The one (D building) combined by LonWorks has the constant airflow of supply fan and the proportional control of VAV units (damper type). The other (S building) combined by DDC has the PI control mode of the supply fan and the floating control of VAV units (venturi type). In estimating thermal comfort and energy performance through control modes of PI, PID, and CAV in the supply fan, we could identify several energy efficient operating control strategies for the VAV system.

Light Control System For The Saving of Electric Energy (전기에너지 절약을 위한 조명제어시스템)

  • Han, Seung-Ho;Kim, Seong-Cheol;Choi, Kyoung-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.289-292
    • /
    • 2008
  • This paper represents the electric energy saving using light control system. Without Light Control System(LCS), it is very hard to classify the amount of electric energy saving for lighting, since it is determined by the end-user's preference in times. Typical LCS has an fixed algorithm to control each light's intensity by ON/Off Control, Step Control, or Dimming Control. We have studied the electric energy saving effect in a LCS equiped building with natural lighting. The electric power consumption at the peak power consumption time with LCS reduced up to 65% of the non-controled case.

  • PDF

Adaptive Control for Speed of Wound Rotor Induction Motor With Slip Energy Recovery

  • Tunyasrirut, Satean;Kanchanatep, Attapol;Ngamwiwit, Jongkol;Furuya, Tadayoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.419-422
    • /
    • 1998
  • This paper presents how to design speed control of wound rotor induction motors with slip energy recovery. The speed is limited at some range of sub-synchronous speed of the rotating magnetic field. The problem with speed control by adjusting resistance value in the rotor circuit reduces the efficiency of power, because of the slip energy is lost when it passes through the rotor resistance. The control system is designed to maintain efficiency of motor, where it recovers loss energy by returning it to the system to improve the efficiency. A new PI control method of adaptive control [1],[13]is applied for the system with cascade type PI controller on the main loop to keep the speed constant and the internal loop to adjust the rotor appropriated current of the load provides the good transient response without overshoot.

  • PDF

An Development of Landscape Lighting Power Control System with Solar Cell Generator Equipment for Energy Saving (에너지절감을 위한 태양광발전설비 연계형 경관조명 전력제어시스템의 개발)

  • Kim, Dong-Wan;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제59권4호
    • /
    • pp.364-371
    • /
    • 2010
  • In this paper, we propose the landscape lighting power control system with solar sell generator equipment for energy saving, and also which is included the landscape lighting power transformation device. The power transformation device can check inverse current in the power of the solar cell module and control the power of the battery. And we present the design of landscape lighting power control system. The power control system uses microprocessor with charging system and power transformation device. And also it can control the power of loads under consideration intensity of illumination. The landscape lighting loads are composed of LED(Lighting Emitting Diode) and HID(High Intensity Discharge)lamps. To evaluate property, we installed the solar cell array which generate three kilo watt power. Experimental results show that the proposed system can have stability and energy saving on the mixed configuration of electric loads with DC and AC lamps.

A Teleoperated Bilateral Control System for Heavy Duty Tasks

  • S.H. Ahn;Kim, S.H.;D.H. Hong;J.S. Yoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.155.2-155
    • /
    • 2001
  • A heavy duty power manipulator consisting of high reduction ratio joints is usually used in heavy duty tasks. When the heavy duty power manipulator is used as the slave manipulator in the teleoperated bilateral control system, the position control performance of the slave manipulator and the system stability tend to deteriorate due to the windup phenomenon caused by actuator saturation. KAERI has developed a teleoperated bilateral control system for the study of the remote handling of a spent fuel mockup bundle, which has an enhanced bilateral control algorithm improving the position tracking performance of the slave manipulator while compensating for the windup phenomenon. In this paper, the developed bilateral control system ...

  • PDF

Dynamic Model for Ocean Thermal Energy Conversion Plant with Working Fluid of Binary Mixtures

  • Nakamura, Masatoshi;Zhang, Yong;Bai, Ou;Ikegami, Yasuyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2304-2308
    • /
    • 2003
  • Ocean thermal energy conversion (OTEC) is an effective method of power generation, which has a small impact on the environment and can be utilized semi-permanently. This paper describes a dynamic model for a pilot OTEC plant built by the Institute of Ocean Energy, Saga University, Japan. This plant is based on Uehara cycle, in which binary mixtures of ammonia and water is used as the working fluid. Some simulation results attained by this model and the analysis of the results are presented. The developed computer simulation can be used to actual practice effectively, such as stable control in a steady operation, optimal determination of the plant specifications for a higher thermal efficiency and evaluation of the economic prospects and off-line training for the operators of OTEC plant.

  • PDF

Optimal Energy Costs based on Improving Retort Process In Food Canning Manufacturing

  • Saredchapan, Supawut;Chaikla, Amphawan;Masuchun, Ruedee;Trisuwannawat, Thanit;Julsereewong, Prasit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2309-2312
    • /
    • 2003
  • This paper presents the minimization of the energy costs based on energy saving for industrial retort process of canned food. The approved proposed method is related the optimal steam or hot water flow control to achieve desired temperature of retort process. The smooth response and zero steady state error can be also achieved. The performances of the proposed control technique were observed using a small tuna canned food plant in Thailand as an illustrative example. The experimental results are given to support the saving in energy costs and some benefits of the proposed technique.

  • PDF

A Communication Method Between Distributed Control System and Function Test Facility Using TCP/IP and Shared Memory

  • Kim, Jung-Soo;Jung, Chul-Hwan;Kim, Jung-Taek;Lee, Dong-Young;Ham, Chang-Sik
    • Nuclear Engineering and Technology
    • /
    • 제30권4호
    • /
    • pp.298-307
    • /
    • 1998
  • In order to design mutual communication between a distributed control system and a function test facility, we used the Inter-Process Communication(IPC) in two systems and Transmission Control Protocol/Internet Protocol(TCP/IP) protocol. The data from the function test facility are put in the shared memory using an IPC, which is then accessed by the distributed control system through an Application Program Interface(API). The server in the function test facility includes two processes(one for sending and one for receiving), which are generated by the fork function from the client signal. The client in the distributed control system includes two separate programs(one for receiving and one for sending).

  • PDF

Optimum Automated Control Strategies of Inside Slat-type Blind considering Visual Comport and Building Energy Performance (재실자의 시쾌적과 건물에너지성능을 고려한 슬랫형 블라인드 자동제어전략)

  • Oh, Myung-Hwan;Yoon, Jong-Ho;Shin, U-Cheol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.187-195
    • /
    • 2011
  • Glass Envelope is vulnerable to insulation performance and controling solar radiation. Insulation performance is consistently improving these days due to recent building energy saving policy in South Korea. However, solar control at glass envelope is still limited to meeting requirements of ideal high performance. Generally, Inside Blind plays an important role of solar control instead of glass which have a characteristics of transmitted solar. Unfortunately, most of them are controled by occupants and which method is not resonable in building energy. Therefore, achieving the high efficient performance building, automated control blind system considering reduction of building loads have to be adopted. Furthermore, considering occupants visual comport about removing discomfort glare is also essential.

  • PDF