• Title/Summary/Keyword: Energy Consumption Units

Search Result 89, Processing Time 0.029 seconds

Installation for Preparing of Nanopowders by Target Evaporation with Pulsed Electron Beam

  • Sokovnin S. Yu.;Kotov Yu. A.;Rhee C. K.
    • Journal of Powder Materials
    • /
    • v.12 no.3
    • /
    • pp.167-173
    • /
    • 2005
  • Production of weakly agglomerated nanopowders with the characteristic size of about 10 nm and a narrow particle size distribution is still a topical problem especially if the matter is an acceptable output (>50 g/hour), a high purity of the final product, and a low (energy consumption. The available experience and literature data show that the most promising approach to production of such powders is the evaporation-condensation method, which has a set of means for heating of the target. From this viewpoint the use of pulsed electron accelerators for production of nanopowders is preferable since they allow a relatively simple adjustment of the energy, the pulse length, and the pulse repetition rate. The use of a pulsed electron accelerator provides the following opportunities: a high-purity product; only the target and the working gas will interact and their purity can be controlled; evaporation products will be removed from the irradiation zone between pulses; as a result, the electron energy will be used more efficiently; adjustment of the particle size distribution and the characteristic size of particles by changing the pulse energy and the irradiated area. Considering the obtained results, we developed a design and made an installation for production of nanopowders, which is based on a hollow-cathode pulsed gas-filled diode. The use of a hollow-cathode gas-filled diode allows producing and utilizing an electron beam in a single chamber. The emission modulation in the hollow cathode will allow forming an electron beam 5 to 100 ms long. This will ensure an exact selection of the beam energy. By now we have completed the design work, manufactured units, equipped the installation, and began putting the installation into operation. A small amount of nanopowders has been produced.

Comparison of discharging electrodes for the electrostatic precipitator as an air filtration system in air handling units (에어핸들링 유닛의 공기정화용 전기집진기의 방전극 비교)

  • Shin, Dongho;Woo, Chang Gyu;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.11-16
    • /
    • 2017
  • Indoor air quality is of increasing concern because it is closely related human health. An air handling unit (AHU) can be used to control the indoor air quality related to particulate matters and $CO_2$ as well as air conditioning such as temperature and humidity of indoor air. An electrostatic precipitator has a high collection efficiency and low pressure drop, however, ozone can possibly generate from its chargers, which is one of drawbacks to apply it for indoor air control. Here we compared four charging electrodes such as a $50{\mu}m$ tungsten wire, a $100{\mu}m$ tungsten wire, a $16{\mu}m$-thickness Al foil and a carbon fabric comprised of $5-10{\mu}m$ fibers. The carbon fabric electrode showed a superior particle collection efficiency and a lower ozone generation at a given power consumption compared to tungsten wires of 50, $100{\mu}m$ and an Al foil electrode. This low ozone generating, micro-sized electrode can be applied to the electrostatic precipitator in AHU for indoor air control.

Design of an Efficient Power Manger through the cooperative Dynamic Power Management for Ad hoc Wireless Sensor Networks (Ad hoc 무선 센서네트워크에서의 효율 전력 매니지먼트에 관한 연구)

  • Jeon, Dong-Keun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.6
    • /
    • pp.809-814
    • /
    • 2011
  • The major resource problem in sensor networks is energy efficiency. There are two major access methods to efficiently use energy. The first is to use dynamic power management (DPM). The second is to use energy efficient protocols. In DPM methods, the OS, the power manager, is responsible for managing the proper power state of CPU and each I/O with respect to the events, but the OS is not largely concerned about the internal operation of each network protocols. Also, energy efficient protocols are mainly focused on the power saving operation of the radio PHY. In addition, in wireless sensor network most of tasks are connected to communication. In such a situation, traditional power managers can waste unpredicted power. In this paper, we introduce an efficient power manger that can reduce a lot of unwanted power consumption through cooperative power management (CPM) in communication-related tasks between each units, such as radio, sensing unit, and CPU, for ad hoc wireless sensor nodes.

Performance Evaluation of Propane(R290)/Isobutane(R600a) Mixture as a Substitute for CFC12 in Domestic Refrigerators (프로판/이소부탄 혼합냉매를 적용한 가정용 냉장고의 성능에 관한 연구)

  • Lim, B.H.;Park, Y.B.;Yoo, H.K.;Jung, D.S.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.249-265
    • /
    • 1995
  • The performance of a refrigerant mixture of propane(R290)/isobutane(R600a) as a substitute for CFC12 was investigated in a domestic refrigerator with single evaporator. A thermodynamic cycle simulation indicated an increase in COP of a 1.7 to 2.4% with R-290/600a in the composition range of 0.2 to 0.6 mass fraction of R290 compared to CFC12. For the tests, two units($299{\ell}$, $465{\ell}$) were used. All refrigeration components remained the same throughout the tests, except that the length of capillary tube and amount of charge were changed for the mixture. The refrigerators were fully instrumented with more than 20 thermocouples, 2 pressure transducers, and watt/watt-hour meter for each refrigerator. 'Energy consumption test' and 'no load pulldown test' were performed under the same condition. The experimental results obtained with the same compressor indicated that R-290/600a mixture at 0.6 mass fraction of R290 showed a 3 to 5% increase in energy efficiency and a faster cooling speed compared to CFC12. The R-290/600a mixture showed a shorter compressor on-time and a lower compressor dome temperature than CFC12. In conclusion, the proposed hydrocarbon mixture seems to be an appropriate candidate to replace CFC12 without causing more environmental problems.

  • PDF

A Design of an AMI System Based on an Extended Home Network for the Smart Grid (스마트 그리드를 위한 확장 홈 네트워크 기반의 AMI 시스템 설계)

  • Hwang, Yu-Jin;Lee, Kwang-Hui
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.7
    • /
    • pp.56-64
    • /
    • 2012
  • A smart grid is the next generation power grid which combines the existing power grid with information technology, so an energy efficient power grid can be provided. In this paper, in order to build an efficient smart grid an AMI system, which gears with the existing home network and provides an user friendly management function, is proposed. The proposed AMI system, which is based on an extended home network, consists of various functional units; smart meters, communication modules, home gateway, security modules, meter data management modules (MDMM), electric power application modules and so on. The proposed home network system, which can reduce electric power consumption and transmit data more effectively, is designed by using IEEE 802.15.4. The extended home gateway can exchange energy consumption information with the outside management system via web services. The proposed AMI system is designed to enable two-way communication between the home gateway and MDMM via the Internet. The AES(Advanced Encryption Standard) algorithm, which is a symmetric block cipher algorithm, is used to ensure secure information exchange. Even though the results in this study could be limited to our experimental environment, the result of the simulation test shows that the proposed system reduces electric power consumption by 4~42% on average compared to the case of using no control.

Buffer Cache Management for Low Power Consumption (저전력을 위한 버퍼 캐쉬 관리 기법)

  • Lee, Min;Seo, Eui-Seong;Lee, Joon-Won
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.6
    • /
    • pp.293-303
    • /
    • 2008
  • As the computing environment moves to the wireless and handheld system, the power efficiency is getting more important. That is the case especially in the embedded hand-held system and the power consumed by the memory system takes the second largest portion in overall. To save energy consumed in the memory system we can utilize low power mode of SDRAM. In the case of RDRAM, nap mode consumes less than 5% of the power consumed in active or standby mode. However hardware controller itself can't use this facility efficiently unless the operating system cooperates. In this paper we focus on how to minimize the number of active units of SDRAM. The operating system allocates its physical pages so that only a few units of SDRAM need to be activated and the unnecessary SDRAM can be put into nap mode. This work can be considered as a generalized and system-wide version of PAVM(Power-Aware Virtual Memory) research. We take all the physical memory into account, especially buffer cache, which takes an half of total memory usage on average. Because of the portion of buffer cache and its importance, PAVM approach cannot be robust without taking the buffer cache into account. In this paper, we analyze the RAM usage and propose power-aware page allocation policy. Especially the pages mapped into the process' address space and the buffer cache pages are considered. The relationship and interactions of these two kinds of pages are analyzed and exploited for energy saving.

A study on the introduction of organic waste-to-energy incentive system(III): Preparation of an incentive system for biogasification (proposal) (유기성폐자원에너지 인센티브제도 도입방안 연구(III): 바이오가스화 인센티브제도(안) 마련)

  • Moon, Hee-Sung;Kwon, Jun-Hwa;Lee, Won-Seok;Lee, Dong-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.4
    • /
    • pp.87-97
    • /
    • 2021
  • This study was conducted to prepare an incentive system (proposal) for the activation of waste-to-energy. Weights for each type of energy use were prepared by conducting prior research and economic analysis. In addition, the waste-to-energy incentive (proposal) was calculated in consideration of energy efficiency for each type of energy use. As a result of economic analysis of 11 biogasification facilities, the B/C value was found to be very diverse, ranging from 0.16 to 1.69. In terms of benefits, imports of waste treatment import fees were very high at 68.4 to 99.3% of the total, and four facilities with a surplus (+) or higher in the management balance. In order to convert energy consumption into units of sales volume, 0.58 Nm3/KW for power generation, 0.17 Nm3/kg for steam, and 1.00 Nm3/Nm3 for external supply were calculated using the 'scale factor'. The 'weight factor' was calculated as 0.249 for power generation, 0.656 for steam, and 0.806 for external supply, respectively, by use type.

Investigation into Methods for reducing Greenhouse Gas Emission in Paper Industry with Development of Greenhouse Gas Inventory (온실가스 인벤토리 구축을 통한 제지산업에서 온실가스 절감 방법론 조사)

  • Kim, Dong-Seop;Sung, Yong-Joo;Lee, Joon-Woo;Kim, Se-Bin;Park, Gwan-Soo
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.2
    • /
    • pp.49-57
    • /
    • 2012
  • The reduction of greenhouse gas emission currently becomes more urgent task for Korean Industries, especially for the paper industries because of the new regulation based on the low carbon-green growth law. In order to reduce effectively the greenhouse gas emission, the development of greenhouse gas emission inventory has been widely considered as one of the basic processes and has been applied to many industries. In this study, the fundamental schemes and the cases of greenhouse gas inventories were investigated. Especially, the major considering units for paper industries were suggested to develope greenhouse emission inventory of paper industry.

Low Power Trace Cache for Embedded Processor

  • Moon Je-Gil;Jeong Ha-Young;Lee Yong-Surk
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.204-208
    • /
    • 2004
  • Embedded business will be expanded market more and more since customers seek more wearable and ubiquitous systems. Cellular telephones, PDAs, notebooks and portable multimedia devices could bring higher microprocessor revenues and more rewarding improvements in performance and functions. Increasing battery capacity is still creeping along the roadmap. Until a small practical fuel cell becomes available, microprocessor developers must come up with power-reduction methods. According to MPR 2003, the instruction and data caches of ARM920T processor consume $44\%$ of total processor power. The rest of it is split into the power consumptions of the integer core, memory management units, bus interface unit and other essential CPU circuitry. And the relationships among CPU, peripherals and caches may change in the future. The processor working on higher operating frequency will exact larger cache RAM and consume more energy. In this paper, we propose advanced low power trace cache which caches traces of the dynamic instruction stream, and reduces cache access times. And we evaluate the performance of the trace cache and estimate the power of the trace cache, which is compared with conventional cache.

  • PDF

Development of Hanging Type Circular-patterned System for Strawberry Cultivation (행거식 순환형 딸기 재배시스템 개발)

  • Sewoong An;Dong Eok Kim;Soonjung Hong;Dong Hyeon Kang
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.26 no.2
    • /
    • pp.25-30
    • /
    • 2024
  • This study was conducted to develop the hanging type circular-patterned system that at maximizing the spatial efficiency of strawberry cultivation to increase yields, while also reducing labor and improving energy efficiency. The system consists of a cultivation bed units, longitudinal moving device, bed lifting device, front and rear transfer devices, lateral transfer device, nutrient supply device, and control unit. Performance testing revealed that the operational motor for longitudinal movement should have a torque of at least 0.1Nm based on the design weight and traction force of the cultivation bed unit. The power consumption required to move one cycle was calculated to be approximately 149Wh when performing harvesting or maintenance tasks for all 10 cultivation beds. Vibration angles measured during bed movement showed that the lateral transfer resulted in a roll angle ranging from -0.62° to 0.68° and a pitch angle ranging from -3.79° to 5.26°. For longitudinal transfer, the roll angle ranged from -3.37° to 3.36°, and the pitch angle ranged from -0.45° to 0.49°.