• Title/Summary/Keyword: Endurance strength

Search Result 478, Processing Time 0.035 seconds

A study on the Bending Fatigue Strength of Die Steels coated with VC(Vanadium Carbide)by Immersing in Molten Borax Bath (용융염 침적법에 의한 VC coating 금형강의 굽힘 피로강도에 관한 연구)

  • Lee, B.K.;Nam, T.W.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.6 no.3
    • /
    • pp.166-177
    • /
    • 1993
  • Bending fatigue strength tests were made for VC coated die steels which were coated by immersing in a molten borax bath and for hardened die steels which were quenched and tempered, in order to clarify the effect of VC coating at $1000^{\circ}C$ and $1025^{\circ}C$. The material used in this investigation was a representative cold and hot die steels STD11, STD61. The results obtained are as follows. 1) The endurance limit of VC coated die steels was a little lower than that of hardened die steels. It is considered to be mainly due to the decfl.lase of hardness in the substrates. Accordingly, the endurance limit reo covered almost to the level of hardened die steels by an additional diffusion treatment. 2) The initiation point of fatigue fracture of VC coated die steels in reversed bening was on the substrate just under the VC layer. Hence, the endurance limit is corrected to the hardness of this part. 3) But, there is a considerable scatter in this relationship and the endurance limit of VC coated die steels was a little lower than that of hardened die steels with equal hardness. These results suggest that the fatigue strength of VC coated die steels is determined not only by the hardness but also by other factors. For example. the residual stress in the substrate just under VC coating layer is one of the factors besides hardness which is mainly related to the retained austenite(${\gamma}_R$).

  • PDF

Spalling Resistance of $80{\sim}100MPa$ High Strength Concrete ($80{\sim}100MPa$급 고강도 콘크리트의 폭렬방지)

  • Heo, Young-Sun;Pei, Chang-Chun;Lee, Jae-Sam;Han, Chang-Pyung;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.481-484
    • /
    • 2006
  • This study investigates the engineering and fire endurance properties of ultra high strength concrete. The mixture proportions with water to binder ratios (W/B) of 0.15 and 0.25 consist of various adding ratios, such as 0, 0.05, 0.1, 0.15, 0.2, 0.25 and 0.3 percent respectively, of polypropylene (PP) fiber. As for the parameters of specimens, fluidity, compressive strength and unloading fire test were carried out. Test showed that an increase of fiber contents had the favorable properties in fire endurance performance; specimens in W/B 15% required 0.3vol% of PP fiber and specimens in W/B 25% needed only 0.1vol% to prevent spalling.

  • PDF

A Study on Physical Fitness in Student Nurses (간호대학생의 체력에 관한 조사)

  • Kim Hyang-Dong;Park Jeong-Suk;Kwon Young-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.10 no.3
    • /
    • pp.399-407
    • /
    • 2003
  • Purpose: This study was done to identify levels of physical fitness in student nurses and to ascertain the relationship among the different aspects of physical fitness of strength, power, muscle endurance, agility, balance and flexibility. Method: The participants were 266 students selected from one college of nursing. From May 1 to July 31 in 2003, physical constitution, muscle strength (grip strength, back strength), power (standing long jump), muscle endurance (sit-ups), agility (whole body reaction time-light, sound), balance (close-eyes foot-balance), and flexibility (sitting trunk flexion) were measured. Result: The mean(standard deviation) for grip strength was 22.59(3.93) kg., for back strength, 48.52(12.85) kg., for standing long jump, 135.29(20.54) m., for sit-up's, 23.66(9.35) per minute, whole body reaction time (light), 0.43(0.11) sec, whole body reaction time (sound), 0.50(0.16) sec, close-eyes foot-balance, 33.35(38.67) sec, and sitting trunk flexion 34.72(9.37) cm. Conclusion: This study showed that the physical fitness of student nurses is very low compared to the results in a report from the Korea Sports Science Institute. It is necessary to include exercise programs for student nurses in order to improve their physical fitness.

  • PDF

Changes in Median Frequency of Quadriceps Muscle According to Application Modes of Neuromuscular Electrical Stimulation (신경근전기자극 적용양식에 따른 대퇴사두근의 중앙주파수 변화)

  • Choi, Soo-Hee;Oh, Myung-Hwa;Kim, Tae-Youl;Jeong, Jin-Gyu
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.3 no.1
    • /
    • pp.49-59
    • /
    • 2005
  • This study assigns each 8 of 24 normal persons to control group(Group I), strength increase group(Group II) and endurance increase group(Group III) to analyze differences in changes of strength and endurance with surface electromyography and kinetics according to application modes of neuromuscular electrical stimulation(NMES). Group I had not any treatment, group II performed 15 repeated contraction with 60% intensity of maximal voluntary isometric contraction(MVIC) by setting 10-sec on time and 50-sec off time and group III conducted 30 repeated contraction with 30% intensity of MVIC by setting 10-sec on time and 20-sec off time. For neuromuscular electrical stimulation, 2,500 Hz of Russian current, 35 pps of pulse rate and 200 of pulse width. Neuromuscular electrical stimulation was conducted by five times for total 4 weeks. Before and after experimentmotor unit action potential of vastus medialis, rectus femoris and vastus lateralis were measured with sEMG, median frequency(MDF) was analyzed, and thus the following results were obtained. There was significant difference in the period of measuring vastus medialis and rectus femoris in change of MDF and interaction among groups with analysis of surface electromyography before and after neuromuscular electrical stimulation(p<.001) and in particular, there was a remarkable change among groups according to the period of measurement. In conclusion, NMES influenced changes of strength and endurance according to its application modes and in particular, it was found that strength increment application had a significant influence on strength increment in applying short-time NMES.

  • PDF

Mechanical strength of Zirconia Abutment in Implant Restoration (지르코니아 임플란트 지대주의 기계적 강도에 관한 연구)

  • Shin, Sung-ae;Kim, Chang-Seop;Cho, Wook;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.349-360
    • /
    • 2009
  • Purpose: As the esthetic demands of dental implant patients are increased, the demands of zirconia as implant abutment material are also increased. It has non-metalic color, good biocompatibility, high strength and high toughness. Even thought the advatage of zirconia abutment, there are a few studies about mechanical properties of zirconia abutment. This study evaluated the mecanical strength with compressive bending strength and endurance limit of implant-zirconia abutment assembly. Materials and Methods: Static and cyclic loading of implant-Zirconia abutment assembly were simulated under worst case condition according to ISO. Test groups were implants of external butt joint with straight regular diameter and angled regular diameter zirconia abutment, implant of external butt joint with narrow straight diameter zirconia abutment and implant of internal conical joint with straight narrow diameter zirconia abutment. All test group were evaluated the mecanical strength with compressive bending strength and endurance limit. After fatique testing, fracture surface were examined by SEM. Results: The compressive bending strengths exceed 927N. Regular diameter zirconia abutment were stronger than narrow diameter zirconia abutment(P<.05). The endurance limits ranged from 503N to 868N. Conclusion: Within the limitation of this study, zirconia implant abutment exceeded the estabilished values for maximum incisal biting forces reported in the literature.

Evaluation of Fatigue Endurance for an MTB Frame (산악용 자전거 프레임의 피로 내구성 평가)

  • Kim, Taek Young;Lee, Man Suk;Lim, Woong;Kim, Ho Kyung
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.1-5
    • /
    • 2013
  • In order to evaluate fatigue endurance for an MTB(mountain bike) frame, FEM(finite element method) analysis was performed. For evaluating the fatigue endurance of the MTB frame, the S-N data for Al-6061 fillet weldment were compared with the stress analysis results through FEM analysis of the frame. Three loading condition, pedalling, horizontal and vertical loading conditions were considered for fatigue endurance evaluation. Horizontal loading(+1200 N) condition was found to be the most severe to the frame. The maximum von Mises stress of the frame under horizontal loading(+1200 N) condition was determined 294 MPa through FEM analysis of the frame. Conclusively, on the basis of fatigue strength of 200 MPa at the number of cycles of 50,000, the MTB frame has an improper safety factor of approximately 0.25, suggesting that this frame needs reinforcement.

Stress Analysis and Design Improvement to Prevent Failure of the Damping Hinges of Built-in Refrigerators (빌트인 냉장고 댐핑힌지의 응력해석 및 파손방지를 위한 설계개선)

  • Lee, Boo-Youn
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.81-88
    • /
    • 2020
  • The damping hinge of a built-in refrigerator was examined in terms of its stress and fatigue life. Analysis of the initial design showed that stress concentration occurred at the concave surface of the hinge lever, which was broken during the door opening-and-closing endurance test of the prototype. The maximum von Mises stress at this location exceeded the yield strength. In addition, Goodman fatigue analysis of the initial design showed that the fatigue life at this location was consistent with the failure observed during the endurance test. Based on these results, an improved design for the damping hinge was derived. Analysis of this improved design showed that the stress concentration in the hinge lever of the initial design was eliminated. In this case, the maximum stress occurred at the position where the hinge lever was in contact with the door stopping pin, and the maximum von Mises stress was smaller than the yield strength. Goodman fatigue analysis of the improved design indicated that the fatigue life of the entire damping hinge was infinite. It was therefore concluded that the improved design does not suffer from fatigue damage during the endurance test.

Fatigue Strength Evaluation of LCV Leaf spring Considering Road Load Response II (도로 하중조건을 고려한 상용차 판스프링의 피로강도 평가 II)

  • Sohn, Il-Seon;Bae, Dong-Ho;Jung, Won-Seok;Jung, Won-Wook;Park, Sun-Cheol
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1127-1132
    • /
    • 2003
  • Suspension system of vehicle have enough endurance during its life time to protect passenger. Spring is one of major part of vehicle. Thus, a fatigue strength evaluation for leaf spring based on road load response was carried out. At first, strain of leaf spring is measured on the city condition and proving ground condition. And next, the damage analysis of road load response data was carried out. And fatigue test of leaf spring were also carried out. Based on -N life relation, fatigue life of leaf spring was evaluated at belgian mode, city mode and drawing test specification. After that, it is compared the design life of leaf spring and evaluated fatigue life by belgian mode, city mode and drawing test specification. From the above, the maximum load-fatigue life relation of leaf spring was defined by test. and new test target of belgian mode and city mode was proposed to accept design specification of leaf spring. It is expect that proposed test target can verify leaf spring fatigue endurance at specific road condition.

  • PDF

Effect of Active Vibro-Swing Exercise of Upper Limb on Physical Capacity and Vasomotor for Middle Aged Women (상지 능동 진동운동이 중년여성의 신체능력 및 혈관운동성에 미치는 영향)

  • Lee, Hyun Ju;Yim, Hyun Seung;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.264-271
    • /
    • 2020
  • The purpose of this study was to investigate the effects of active vibration exercise of upper limb on physical capacity index (endurance, grip strength, balance, and flexibility) and vasomotor index (capillary length and body surface temperature) in middle aged women. 20 participants randomly divided into two groups: vibro-swing exercise (VSE) and non vibro-swing exercise (NVSE). Subjects in each group measured the 30 second arm curl test, hand dynamometer, one leg standing test, back scratch test, nail fold capillary microscope (NFM), and digital infrared thermal imaging (DITI) before and after exercise. The results showed that active vibration exercise of upper limb with vibro-swing equipment increased the endurance, balance ability, and the capillary length. In addition, changes in body temperature immediately after exercise were predicted to affect vasomotor. Active vibration exercise of upper limb has the advantage of being able to exercise anywhere regardless of the location by inducing different frequency changes in movement of various ranges and velocity. For this reason, the combination of vibration and active movement can be expected the physiological effects when producing exercise programs for middle aged women.

Effects of Korean Ginseng and Wild Simulated Cultivation Ginseng for Muscle Strength and Endurance

  • Sohn, Eun-Hwa;Yang, Yoon Jung;Koo, Hyun Jung;Park, Dae Won;Kim, Ye-Jin;Jang, Ki Ho;NamKoong, Seung;Kang, Se Chan
    • Korean Journal of Plant Resources
    • /
    • v.25 no.6
    • /
    • pp.657-663
    • /
    • 2012
  • Muscle strength and endurance activities of Korean ginseng (Panax ginseng C. A. Meyer; KG) were compared with those of wild simulated cultivation ginseng (WCG) in mice. Fifty male ICR mice were divided into five groups: A (vehicle); B (WCG 100 mg/kg); C (WCG 500 mg/kg); D (KG 100 mg/kg); E (KG 500 mg/kg). Subsequently, the mice were subjected to the forced swimming test (FST) and treadmill test at the $4^{th}$ and $7^{th}$ weeks. The glycogen content in the muscle and blood analysis (levels of glucose, triglyceride (TG), IGF-1) were also performed immediately after the last FST and treadmill test at the $7^{th}$ week. Immobility times in FST were shorter in WCG- than KG-treated groups, and the results of the treadmill tests were also significant except for KG-treated at 100 mg/kg. The glycogen content was increased in both groups with a peak at 500 mg/kg of WCG groups. Serum concentrations of TG and glucose were decreased by administration of KG and WCG and all treated groups showed increase in the level of IGF-1 in serum. These results suggest that KG and WCG supplementations are effective in escalating the muscle strength and endurance.