• 제목/요약/키워드: Endovascular aneurysm repair

검색결과 55건 처리시간 0.025초

Aortopulmonary Fistula Presenting without an Endoleak after Thoracic Endovascular Aortic Repair

  • Sica, Giacomo;Rea, Gaetano;Bocchini, Giorgio;Lombardi, Romilda;Muto, Massimo;Valente, Tullio
    • Journal of Chest Surgery
    • /
    • 제50권4호
    • /
    • pp.287-290
    • /
    • 2017
  • Herein, we report the case of a 60-year-old man, a smoker with a history of arterial hypertension and diabetes mellitus. After computed tomography (CT) for an episode of hemoptysis, the patient underwent elective thoracic endovascular aortic repair (TEVAR) because of a degenerative aneurysm of the descending thoracic aorta. The area of perianeurysmal pulmonary atelectasis reported on the CT scan was not considered. Three months later, he developed an aortopulmonary fistula without endoleaks. Although TEVAR is a relatively safe procedure, no detail should be overlooked in the preoperative evaluation in order to avoid life-threatening complications. Further, the effectiveness and modality of prolonged antibiotic prophylaxis and/or preoperative respiratory physiotherapy should be assessed in such cases.

Delayed Type III Endoleak Caused by Fabric Erosion after Endovascular Repair of an Abdominal Aortic Aneurysm

  • Lee, Jae Hang;Kim, Eung-joong;Choi, Jin-Ho
    • Journal of Chest Surgery
    • /
    • 제50권4호
    • /
    • pp.291-294
    • /
    • 2017
  • A 74-year-old patient presented with recurrent aneurysms in the infrarenal abdominal aorta and right common iliac artery 6 years after endovascular aortic repair using endografts in the same location. The patient underwent an aorto-bi-iliac replacement with removal of the stent graft. Two holes measuring 2 mm each were found in the removed graft, and they appeared to have been caused by wear from continuous friction between the endograft and the aortic wall.

Acute Thrombotic Occlusion of Left Internal Jugular Vein Compressed by Bypass Graft for Thoracic Endovascular Aortic Repair Debranching Procedure

  • Sim, Hyung Tae;Beom, Min Sun;Kim, Sung Ryong;Ryu, Sang Wan
    • Journal of Chest Surgery
    • /
    • 제47권6호
    • /
    • pp.552-555
    • /
    • 2014
  • Thoracic endovascular aortic repair has become a widespread alternative treatment option for thoracic aortic aneurysm. The debranching of arch vessels may be required to provide an acceptable landing zone for an endovascular stent graft. We report a case where the bypass graft used in the thoracic endovascular aortic repair procedure compressed the left internal jugular vein, causing acute thrombotic occlusion.

Clinical Efficacy of Endovascular Abdominal Aortic Aneurysm Repair

  • Son, Bong-Su;Chung, Sung-Woon;Lee, Chung-Won;Ahn, Hyo-Yeong;Kim, Sang-Pil;Kim, Chang-Won
    • Journal of Chest Surgery
    • /
    • 제44권2호
    • /
    • pp.142-147
    • /
    • 2011
  • Background: Endovascular aortic aneurysm repair (EVAR) has come into use and been widely extended because of the low complication rate and less-invasiveness. This article aimed to describe our experience in the treatment of abdominal aortic aneurysm with EVAR. Materials and Methods: A retrospective review was conducted for the 22 patients who underwent EVAR in a single hospital December 2001 to June 2009. Results: The mean age of the patients was $68.5{\pm}7.6$ years. There were several risk factors and comorbidities in 20 patients (90.9%). The mean diameter of the aortic aneurysms was $61.2{\pm}12.9$ mm. The mean length, diameter, and angle of the aneurysmal neck were $30.5{\pm}15.5$ mm, $24.0{\pm}4.5$ mm, and $43.9{\pm}16.0^{\circ}$, respectively. The mean follow-up period of the patients was $28.8{\pm}29.5$ months. The 30-day postoperative mortality was none. Seven patients (31.8%) had endoleaks during the hospital stay and three patients (13.6%) had endoleaks during the follow-up period. One patient (4.5%) died due to a ruptured aortic aneurysm. The cumulative patient survival rates were 88.2%, 88.2%, and 70.6% at 1, 3, and 5 years of follow-up, respectively. Conclusion: EVAR is currently a safe, feasible procedure for high risk patients with abdominal aortic aneurysm because of low postoperative complication and mortality if patients are selected properly and followed up carefully.

Tuberculous Aneurysm of the Abdominal Aorta: Endovascular Repair Using Stent Grafts in Two Cases

  • Wei Chiang Liu;Byung Kook Kwak;Kyo Nam Kim;Soon Yong Kim;Joung Joo Woo;Dong Jin Chung;Ju Hee Hong;Ho Sung Kim;Chang Jun Lee;Hyung Jin Shim
    • Korean Journal of Radiology
    • /
    • 제1권4호
    • /
    • pp.215-218
    • /
    • 2000
  • Tuberculous aneurysm of the aorta is exceedingly rare. To date, the standard therapy for mycotic aneurysm of the abdominal aorta has been surgery involving in-situ graft placement or extra-anatomic bypass surgery followed by effective anti-tuberculous medication. Only recently has the use of a stent graft in the treatment of tuberculous aortic aneurysm been described in the literature. We report two cases in which a tuberculous aneurysm of the abdominal aorta was successfully repaired using endovascular stent grafts. One case involved is a 42-year-old woman with a large suprarenal abdominal aortic aneurysm and a right psoas abscess, and the other, a 41-year-old man in whom an abdominal aortic aneurysm ruptured during surgical drainage of a psoas abscess.

  • PDF

Use of Embolic Protection Devices during Hybrid Thoracic Endovascular Aortic Repair for a Shaggy Aorta: A Case Report

  • Kim, Eun Chae;Lee, Jae Hang;Chang, Hyoung Woo;Kim, Dong Jung;Kim, Jun Sung;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • 제54권6호
    • /
    • pp.513-516
    • /
    • 2021
  • An 87-year-old man presented with a saccular aneurysm at the proximal descending thoracic aorta. As computed tomography revealed a shaggy aorta, we planned hybrid thoracic endovascular aortic repair (TEVAR) with embolic protection devices (EPDs) in both internal carotid arteries to prevent a cerebrovascular accident. We inserted an Emboshield NAV6 Embolic Protection System (Abbott Vascular, Abbott Park, IL, USA) into both internal carotid arteries before performing the TEVAR procedure. The patient was discharged from the hospital on postoperative day 4 without any neurological complications.

Type I 급성 대동맥 박리 수술 후 진행하는 원위부 박리성 동맥류에 대한 대동맥궁 탈분지술과 전향적 대동맥궁 스텐트 그라프트의 설치 (Aortic Arch Debranching and Antegrade Stent Graft Placement in an Expanding Distal Dissecting Aneurysm after Repair of an Acute Type I Aortic Dissection)

  • 백완기;김영삼;임현경;윤용한;김정택;김광호
    • Journal of Chest Surgery
    • /
    • 제43권6호
    • /
    • pp.729-733
    • /
    • 2010
  • 스텐트 그라프트를 이용한 대동맥류에 대한 혈관내 치료는 급격히 발전하고 있다. 저자들은 대동맥궁 탈분지술 후 스텐트 그라프트를 설치한 hybrid TEVAR (thoracic endovascular aortic repair) 1예에 대해 보고하고자 한다. 환자는 2년 반 전 Type I 급성 대동맥 박리로 상행 대동맥 치환술을 시행하였다. 수술 후 박리 원위부의 동맥류성 변화가 점차 진행하여 이에 대한 치료로 먼저 상행 대동맥으로 부터 무명동맥과 좌경동맥으로 향하는 우회로를 만든 다음 전향적으로 대동맥궁 전체 및 근위부 하행 흉부 대동맥에 걸쳐 스텐트 그라프트를 설치하였다.

Utility of Noncontrast Magnetic Resonance Angiography for Aneurysm Follow-Up and Detection of Endoleaks after Endovascular Aortic Repair

  • Hiroshi Kawada;Satoshi Goshima;Kota Sakurai;Yoshifumi Noda;Kimihiro Kajita;Yukichi Tanahashi;Nobuyuki Kawai;Narihiro Ishida;Katsuya Shimabukuro;Kiyoshi Doi;Masayuki Matsuo
    • Korean Journal of Radiology
    • /
    • 제22권4호
    • /
    • pp.513-524
    • /
    • 2021
  • Objective: To assess the noncontrast two-dimensional single-shot balanced turbo-field-echo magnetic resonance angiography (b-TFE MRA) features of the abdominal aortic aneurysm (AAA) status following endovascular aneurysm repair (EVAR) and evaluate to detect endoleaks (ELs). Materials and Methods: We examined four aortic stent-grafts in a phantom study to assess the degree of metallic artifacts. We enrolled 46 EVAR-treated patients with AAA and/or common iliac artery aneurysm who underwent both computed tomography angiography (CTA) and b-TFE MRA after EVAR. Vascular measurements on CTA and b-TFE MRA were compared, and signal intensity ratios (SIRs) of the aneurysmal sac were correlated with the size changes in the AAA after EVAR (AAA prognoses). Furthermore, we examined six feasible b-TFE MRA features for the assessment of ELs. Results: There were robust intermodality (r = 0.92-0.99) correlations and interobserver (intraclass correlation coefficient = 0.97-0.99) agreement. No significant differences were noted between SIRs and aneurysm prognoses. Moreover, "mottled high-intensity" and "creeping high-intensity with the low-band rim" were recognized as significant imaging findings suspicious for the presence of ELs (p < 0.001), whereas "no signal black spot" and "layered high-intensity area" were determined as significant for the absence of ELs (p < 0.03). Based on the two positive features, sensitivity, specificity, and accuracy for the detection of ELs were 77.3%, 91.7%, and 84.8%, respectively. Furthermore, the k values (0.40-0.88) displayed moderate-to-almost perfect agreement. Conclusion: Noncontrast MRA could be a promising imaging modality for ascertaining patient follow-up after EVAR.

Endovascular Repair in Acute Complicated Type B Aortic Dissection: 3-Year Results from the Valiant US Investigational Device Exemption Study

  • Lim, Chang Young
    • Journal of Chest Surgery
    • /
    • 제50권3호
    • /
    • pp.137-143
    • /
    • 2017
  • Acute complicated type B aortic dissection (TBAD) is a potentially catastrophic, life-threatening condition. If left untreated, there is a high risk of aortic rupture, irreversible organ or limb damage, or death. Several risk factors have been associated with acute complicated TBAD, including age and refractory hypertension. In the acute phase, even uncomplicated patients are more prone to develop complications if hypertension and pain are left medically untreated. Innovations in stent graft technologies have incrementally improved outcomes since their first use for this condition in 1999, though improvement is needed in mitigating periprocedural complications, adverse events, and mortality. In the past decade, endovascular repair has become the preferred treatment because of its superior outcomes to open repair and medical therapy. The Valiant Captivia Thoracic Stent Graft System is a third-generation endovascular stent graft with advancements in minimally invasive delivery, conformability to the anatomy, and the minimization of adverse sequelae. Herein, this stent graft is briefly reviewed and its 3-year outcomes are presented. Freedom from all-cause and dissection-related mortality was 79.1% and 90.0%, respectiv ely. The Valiant Captiv ia Stent Graft represents a safe, effective intervention for acute complicated TBAD. Continued surveillance is needed to verify its longer-term durability.

자가팽창성 Stent-graft의 경관적 설치술을 이용한 대동맥류의 치료 -2 예 보고- (Endovascular Placement of Self-Expandable Stent-Graft for the Treatment of Aortic Aneurysms -2 cases-)

  • 신현우;이재성
    • Journal of Chest Surgery
    • /
    • 제33권1호
    • /
    • pp.99-102
    • /
    • 2000
  • The usual treatment for aortic aneurysms is surgical replacement with a prosthetic graft; however the associated morbidity and mortality rates must be considered. Endovascular placement of self-expandable stent-graft is a safe noninvasive treatment that can be an alternative to the surgical repair, the postoperative course of the 2 cases of thoracoabdominal aortic aneurysms was uneventful and no complication has been associated with the stent-graft during the 17 months and 5 months follow-up studies,.

  • PDF