• Title/Summary/Keyword: Endoscopy, gastrointestinal

Search Result 590, Processing Time 0.024 seconds

Role of interventional endoscopic ultrasound in a developing country

  • Hasan Maulahela;Nagita Gianty Annisa;Achmad Fauzi;Kaka Renaldi;Murdani Abdullah;Marcellus Simadibrata;Dadang Makmun;Ari Fahrial Syam
    • Clinical Endoscopy
    • /
    • v.56 no.1
    • /
    • pp.100-106
    • /
    • 2023
  • Background/Aims: Endoscopic ultrasound (EUS) has become an essential diagnostic and therapeutic tool. EUS was introduced in 2013 in Indonesia and is considered relatively new. This study aimed to describe the current role of interventional EUS at our hospital as a part of the Indonesian tertiary health center experience. Methods: This retrospective study included all patients who underwent interventional EUS (n=94) at our center between January 2015 and December 2020. Patient characteristics, technical success, clinical success, and adverse events associated with each type of interventional EUS procedure were evaluated. Results: Altogether, 94 interventional EUS procedures were performed at our center between 2015 and 2020 including 75 cases of EUS-guided biliary drainage (EUS-BD), 14 cases of EUS-guided pancreatic fluid drainage, and 5 cases of EUS-guided celiac plexus neurolysis. The technical and clinical success rates of EUS-BD were 98.6% and 52%, respectively. The technical success rate was 100% for both EUS-guided pancreatic fluid drainage and EUS-guided celiac plexus neurolysis. The adverse event rates were 10.6% and 7.1% for EUS-BD and EUS-guided pancreatic fluid drainage, respectively. Conclusions: EUS is an effective and safe tool for the treatment of gastrointestinal and biliary diseases. It has a low rate of adverse events, even in developing countries.

Efficacy of a novel channel-cleaning ball brush for endoscope reprocessing: a randomized controlled trial

  • Kwang Hyun Chung;Jeong Don Chae;Wonho Choe;Hyo Young Lee;Il Hwan Oh;Byoung Kwan Son
    • Clinical Endoscopy
    • /
    • v.55 no.5
    • /
    • pp.674-682
    • /
    • 2022
  • Background/Aims: Endoscopic channels are difficult to clean and can cause infection transmission. We examined the effectiveness of a newly developed channel-cleaning ball brush (BB), which is sucked into the endoscopic channel and scrapes and cleans the lumen as it passes through. Methods: The upper and lower gastrointestinal endoscopes used for patient examinations were randomly selected as the conventional brush (CB) or BB group. After manual cleaning, the presence or absence of carbohydrates, proteins, adenosine triphosphate, and hemoglobin was assessed. Results: Fifty-six and 58 endoscopes were cleaned with the CB and BB, respectively. Carbohydrate and protein were detected in one (1.8%) and two endoscopes (3.4%) in the CB and BB groups, respectively (p=1.000). Hemoglobin was observed in one (1.8%) and three endoscopes (5.2%) in the CB and BB groups, respectively (p=0.636). The adenosine triphosphate levels were 10.6±15.9 and 12.5±14.3 relative light units in the CB and BB groups, respectively (p=0.496). Twenty-seven (48.2%) and 19 (32.8%) endoscopes were positive for microbial cultures in the CB and BB groups, respectively (p=0.136). Conclusions: The efficacy of BB was not significantly different from that of CB in the endoscopic channel-cleaning process.

A Study on Emotional Characteristics Using Upper Gastrointestinal Endoscopic Findings and The Core Seven Emotions Inventory-Short Form (상부위장관내시경 소견과 핵심칠정척도 단축형을 활용한 정서적 특성 연구)

  • Kim, Gwang Woo;Ko, Kyeong Jin;Han, Min Seok;Kang, Seong Hyeon;Kang, Hyung Won;Lyu, Yeoung Su
    • Journal of Oriental Neuropsychiatry
    • /
    • v.33 no.1
    • /
    • pp.21-31
    • /
    • 2022
  • Objectives: To perform correlation analysis between the Core Seven Emotions Inventory-Short Form (CSEI-s), Beck Anxiety Inventory (BAI), Beck Depression Inventory (BDI), upper gastrointestinal symptoms, and gastroscopic findings and to compare emotional characteristics with upper gastrointestinal endoscopic findings. Methods: In this study, medical records of 38 participants who visited the hospital for examination purposes or complained upper gastrointestinal symptoms and completed the CSEI-s, BAI, BDI, and Questionnaire for upper gastrointestinal symptoms were analyzed using SPSS (Statistical Package for the Social Sciences) version 25.0. Frequency Analysis, Descriptive Analysis, Independent t-test, Mann-Whitney's U-test, and Correlation analysis were performed. Results: The upper gastrointestinal symptom group showed higher levels of anger, sorrow, depression, and anxiety than the asymptomatic group. On gastroscopy, the normal group had higher levels of Joy than the abnormal group. The reflux esophagitis group showed higher levels of thought, depression, sorrow, and anxiety than the non-reflux esophagitis group. Joy showed a negative correlation with BDI score. However, anger, depression, sorrow, BAI, and BDI score showed positive correlations. Conclusions: Results of this study suggest that CSEI-s can be used to treat patients with upper gastrointestinal symptoms and reflux esophagitis.

Cost-effectiveness Outcomes of the National Gastric Cancer Screening Program in South Korea

  • Cho, Eun;Kang, Moon Hae;Choi, Kui Son;Suh, MiNa;Jun, Jae Kwan;Park, Eun-Cheol
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2533-2540
    • /
    • 2013
  • Background: Although screening is necessary where gastric cancer is particularly common in Asia, the performance outcomes of mass screening programs have remained unclear. This study was conducted to evaluate cost-effectiveness outcomes of the national cancer screening program (NCSP) for gastric cancer in South Korea. Materials and Methods: People aged 40 years or over during 2002-2003 (baseline) were the target population. Screening recipients and patients diagnosed with gastric cancers were identified using the NCSP and Korea Central Cancer Registry databases. Clinical outcomes were measured in terms of mortality and life-years saved (LYS) of gastric cancer patients during 7 years based on merged data from the Korean National Health Insurance Corporation and National Statistical Office. We considered direct, indirect, and productivity-loss costs associated with screening attendance. Incremental cost-effectiveness ratio (ICER) estimates were produced according to screening method, sex, and age group compared to non-screening. Results: The age-adjusted ICER for survival was 260,201,000-371,011,000 Korean Won (KW; 1USD=1,088 KW) for the upper-gastrointestinal (UGI) tract over non-screening. Endoscopy ICERs were lower (119,099,000-178,700,000 KW/survival) than UGI. To increase 1 life-year, additional costs of approximately 14,466,000-15,014,000 KW and 8,817,000-9,755,000 KW were required for UGI and endoscopy, respectively. Endoscopy was the most cost-effective strategy for males and females. With regard to sensitivity analyses varying based on the upper age limit, endoscopy NCSP was dominant for both males and females. For males, an upper limit of age 75 or 80 years could be considered. ICER estimates for LYS indicate that the gastric cancer screening program in Korea is cost-effective. Conclusion: Endoscopy should be recommended as a first-line method in Korea because it is beneficial among the Korean population.

Polypectomy by Intraoperative Total Gut Endoscopy in a Child with Peutz-Jeghers Syndrome (소아 Peutz-Jeghers 증후군 환자에서 전장 내시경술에 의한 용종 절제술 1례)

  • Kwak, Jeong Won;Kim, Hae Young;Park, Jae Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.8 no.1
    • /
    • pp.76-80
    • /
    • 2005
  • Peutz-Jeghers syndrome is an autosomal dominant inherited syndrome characterized by mucocutaneous pigmentation and gastrointestinal hamartomatous polyps. The most important complications that increase morbidity are intussusception, bleeding and obstruction. Most patients with Peutz-Jeghers syndrome may undergo multiple laparotomies for complications such as intussusception or bleeding every 2 to 3 years during adolescence and early adulthood. To decrease the relaparotomy rate, intraoperative endoscopy may be useful in the treatment of complications that are related to Peutz-Jeghers syndrome. Use of intraoperative endoscopy can lead to a healthier life and to a longer life expectancy for the patient. We describe a case of Peutz-Jeghers syndrome, who underwent polypectomy by total gut endoscopy in an 11-year-old girl presented with intestinal obstruction and anemia. During the course of the operation, the endoscope was inserted per the enterostomy and colostomy sites, and 16 polyps in the small and large intestine were removed endoscopically using a snare.

  • PDF

Prospective Assessment of the Performance of a New Fine Needle Biopsy Device for EUS-Guided Sampling of Solid Lesions

  • El Hajj, Ihab I.;Wu, Howard;Reuss, Sarah;Randolph, Melissa;Harris, Akeem;Gromski, Mark A.;Al-Haddad, Mohammad
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.576-583
    • /
    • 2018
  • Background/Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) remains the most common EUS-guided tissue acquisition technique. This study aimed to evaluate the performance of a new Franseen tip fine needle biopsy (FNB) device for EUSguided sampling of solid lesions and compare it with the historical FNA technique. Methods: $Acquire^{(R)}$ 22 G FNB needle (Boston Scientific Co., Natick, MA, USA) was used for solid tumor sampling (Study group). Tissue was collected for rapid on-site evaluation, and touch and crush preparations were made. Historical EUS-FNA samples obtained using $Expect^{(R)}$ 22 G FNA needle (Boston Scientific Co.) were used as controls (Control group). All specimens were independently evaluated by two cytopathologists blinded to the formal cytopathological diagnosis. Results: Mean cell block histology scores were significantly higher (p=0.046) in the FNB group (51 samples) despite a significantly lower (p<0.001) mean number of passes compared to the FNA group (50 specimens). The overall diagnostic yields for the FNB vs. FNA groups were 96% vs. 88%. The degree of tumor differentiation was adequately assessed in all cell block qualifying lesions in the FNB group. Two patients developed post-FNB abdominal pain. Conclusions: The new Franseen tip FNB device provides histologically superior and cytologically comparable specimens to those obtained by FNA, but with fewer passes.

Integrated Power Optimization with Battery Friendly Algorithm in Wireless Capsule Endoscopy

  • Mehmood, Tariq;Naeem, Nadeem;Parveen, Sajida
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.11
    • /
    • pp.338-344
    • /
    • 2021
  • The recently continuous enhancement and development in the biomedical side for the betterment of human life. The Wireless Body Area Networks is a significant tool for the current researcher to design and transfer data with greater data rates among the sensors and sensor nodes for biomedical applications. The core area for research in WBANs is power efficiency, battery-driven devices for health and medical, the Charging limitation is a major and serious problem for the WBANs.this research work is proposed to find out the optimal solution for battery-friendly technology. In this research we have addressed the solution to increasing the battery lifetime with variable data transmission rates from medical equipment as Wireless Endoscopy Capsules, this device will analyze a patient's inner body gastrointestinal tract by capturing images and visualization at the workstation. The second major issue is that the Wireless Endoscopy Capsule based systems are currently not used for clinical applications due to their low data rate as well as low resolution and limited battery lifetime, in case of these devices are more enhanced in these cases it will be the best solution for the medical applications. The main objective of this research is to power optimization by reducing the power consumption of the battery in the Wireless Endoscopy Capsule to make it battery-friendly. To overcome the problem we have proposed the algorithm for "Battery Friendly Algorithm" and we have compared the different frame rates of buffer sizes for Transmissions. The proposed Battery Friendly Algorithm is to send the images on average frame rate instead of transmitting the images on maximum or minimum frame rates. The proposed algorithm extends the battery lifetime in comparison with the previous baseline proposed algorithm as well as increased the battery lifetime of the capsule.

Methylene blue chromoendoscopy is more useful in detection of intestinal metaplasia in the stomach than mucosal pit pattern or vessel evaluation and predicts advanced Operative Link on Gastric Intestinal Metaplasia stages

  • Justyna Wasielica-Berger;Pawel Rogalski;Anna Pryczynicz;Agnieszka Swidnicka-Siergiejko;Andrzej Dabrowski
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.203-213
    • /
    • 2023
  • Background/Aims: Intestinal metaplasia (IM) of the stomach is a precancerous condition that is often not visible during conventional endoscopy. Hence, we evaluated the utility of magnification endoscopy and methylene blue (MB) chromoendoscopy to detect IM. Methods: We estimated the percentage of gastric mucosa surface staining with MB, mucosal pit pattern, and vessel visibility and correlated it with the presence of IM and the percentage of metaplastic cells in histology, similar to the Operative Link on Gastric Intestinal Metaplasia (OLGIM) stage. Results: IM was found in 25 of 33 (75.8%) patients and in 61 of 135 biopsies (45.2%). IM correlated with positive MB staining (p<0.001) and other than dot pit patterns (p=0.015). MB staining indicated IM with better accuracy than the pit pattern or vessel evaluation (71.7% vs. 60.5% and 49.6%, respectively). At a cut-off point of 16.5% for the MB-stained gastric surface, the sensitivity, specificity, and accuracy of chromoendoscopy in the detection of advanced OLGIM stages were 88.9%, 91.7%, and 90.9%, respectively. The percentage of metaplastic cells detected on histology was the strongest predictor of positive MB staining. Conclusions: MB chromoendoscopy can serve as a screening method for detecting advanced OLGIM stages. MB mainly stains IM areas with a high concentration of metaplastic cells.

Significance of rescue hybrid endoscopic submucosal dissection in difficult colorectal cases

  • Hayato Yamaguchi;Masakatsu Fukuzawa;Takashi Kawai;Takahiro Muramatsu;Taisuke Matsumoto;Kumiko Uchida;Yohei Koyama;Akir Madarame;Takashi Morise;Shin Kono;Sakik Naito;Naoyoshi Nagata;Mitsushige Sugimoto;Takao Itoi
    • Clinical Endoscopy
    • /
    • v.56 no.6
    • /
    • pp.778-789
    • /
    • 2023
  • Background/Aims: Hybrid endoscopic submucosal dissection (ESD), in which an incision is made around a lesion and snaring is performed after submucosal dissection, has some advantages in colorectal surgery, including shorter procedure time and preventing perforation. However, its value for rescue resection in difficult colorectal ESD cases remains unclear. This study evaluated the utility of rescue hybrid ESD (RH-ESD). Methods: We divided 364 colorectal ESD procedures into the conventional ESD group (C-ESD, n=260), scheduled hybrid ESD group (SH-ESD, n=69), and RH-ESD group (n=35) and compared their clinical outcomes. Results: Resection time was significantly shorter in the following order: RH-ESD (149 [90-197] minutes) >C-ESD (90 [60-140] minutes) >SH-ESD (52 [29-80] minutes). The en bloc resection rate increased significantly in the following order: RH-ESD (48.6%), SH-ESD (78.3%), and C-ESD (97.7%). An analysis of factors related to piecemeal resection of RH-ESD revealed that the submucosal dissection rate was significantly lower in the piecemeal resection group (25% [20%-30%]) than in the en bloc resection group (40% [20%-60%]). Conclusions: RH-ESD was ineffective in terms of curative resection because of the low en bloc resection rate, but was useful for avoiding surgery.

Does computer-aided diagnostic endoscopy improve the detection of commonly missed polyps? A meta-analysis

  • Arun Sivananthan;Scarlet Nazarian;Lakshmana Ayaru;Kinesh Patel;Hutan Ashrafian;Ara Darzi;Nisha Patel
    • Clinical Endoscopy
    • /
    • v.55 no.3
    • /
    • pp.355-364
    • /
    • 2022
  • Background/Aims: Colonoscopy is the gold standard diagnostic method for colorectal neoplasia, allowing detection and resection of adenomatous polyps; however, significant proportions of adenomas are missed. Computer-aided detection (CADe) systems in endoscopy are currently available to help identify lesions. Diminutive (≤5 mm) and nonpedunculated polyps are most commonly missed. This meta-analysis aimed to assess whether CADe systems can improve the real-time detection of these commonly missed lesions. Methods: A comprehensive literature search was performed. Randomized controlled trials evaluating CADe systems categorized by morphology and lesion size were included. The mean number of polyps and adenomas per patient was derived. Independent proportions and their differences were calculated using DerSimonian and Laird random-effects modeling. Results: Seven studies, including 2,595 CADe-assisted colonoscopies and 2,622 conventional colonoscopies, were analyzed. CADe-assisted colonoscopy demonstrated an 80% increase in the mean number of diminutive adenomas detected per patient compared with conventional colonoscopy (0.31 vs. 0.17; effect size, 0.13; 95% confidence interval [CI], 0.09-0.18); it also demonstrated a 91.7% increase in the mean number of nonpedunculated adenomas detected per patient (0.32 vs. 0.19; effect size, 0.05; 95% CI, 0.02-0.07). Conclusions: CADe-assisted endoscopy significantly improved the detection of most commonly missed adenomas. Although this method is a potentially exciting technology, limitations still apply to current data, prompting the need for further real-time studies.