• Title/Summary/Keyword: Endodontic file

Search Result 64, Processing Time 0.029 seconds

Comparison of three digital radiographic imaging systems for the visibility of endodontic files (근관 파일의 인지도 평가시 세 가지 디지털 방사선영상시스템의 비교)

  • Park Jong-Won;Kim Eun-Kyung;Han Won-Jeong
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.145-150
    • /
    • 2004
  • Purpose: To compare three digital radiographic imaging sensors by evaluating the visibility of endodontic file tips with interobserver reproducibility and assessing subjectively the clarity of images in comparison with the x-ray film images. Materials and Methods: Forty-five extracted sound premolars were used for this study. Fifteen plaster blocks were made with three premolars each and #8, 10, 15 K-flexofiles were inserted into the root canal of premolars. They were radiographically exposed using periapical x-ray films (Kodak Insight Dental film, Eastmann Kodak company, Rochester, USA), Digora imaging plates (Soredex-Orion Co., Helsinki, Finland), CDX 2000HQ sensors (Biomedisys Co., Seoul, Korea), and CDR sensors (Schick Inc., Long Island, USA). The visibility of endodontic files was evaluated with interobserver reproducibility, which was calculated as the standard deviations of X, Y coordinates of endodontic file tips measured on digital images by three oral and maxillofacial radiologists. The clarity of images was assessed subjectively using 3 grades, i.e. plus, equal, and minus in comparison with the conventional x-ray film images. Results: Interobserver reproducibility of endodontic file tips was the highest in CDR sensor (p < 0.05) only except at Y coordinates of #15 file. In the subjective assessment of the image clarity, the plus grade was the most frequent in CDR sensor at all size of endodontic file (p < 0.05). Conclusion : CDR sensor was the most superior to the other sensors, CDX 2000HQ sensor and Digora imaging plate in the evaluation of interobserver reproducibility of endodontic file tip and subjective assessment of image clarity.

  • PDF

ROOT CANAL TREATMENT ON PRIMARY TEETH USING NICKEL-TITANIUM NOTARY FILES (회전식 nickel-titanium file을 이용한 유치의 근관치료)

  • Seo, Ju-Hee;Lee, Kwang-Hee;Kim, Dae-Eop;Yang, Kye-Sik
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.620-625
    • /
    • 2001
  • The pulpectomy or root canal treatment on primary teeth is to be done when there is evidence of chronic in flammation or necrosis in the radicular pulp. Due to the tortuous and ribbon-shaped anatomy of the primary teeth, the instrumentation of endodontic hand files and barbed broaches is not an easy procedure. Recently, many automatic Ni-Ti rotary instruments have been developed and has made endodontic treatment easier and faster. This report describes two cases of root canal treatment on primary molars using Ni-Ti rotary files. The cervical constricture was eliminated by the crown-down method, as smaller file proceeded unhindered into the apical third of the canal. In addition, the crown-down technique enhanced the efficacy of the endodontic irrigant. The use of rotary instrumentation for primary teeth seemed to be a more effective way to debride the uneven walls of primary teeth.

  • PDF

Effects of the endodontic access cavity on apical debris extrusion during root canal preparation using different single-file systems

  • Tufenkci, Pelin;Yilmaz, Koray;Adiguzel, Mehmet
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.3
    • /
    • pp.33.1-33.10
    • /
    • 2020
  • Objectives: This study was conducted to evaluate the effects of traditional and contracted endodontic cavity (TEC and CEC) preparation with the use of Reciproc Blue (RPC B) and One Curve (OC) single-file systems on the amount of apical debris extrusion in mandibular first molar root canals. Materials and Methods: Eighty extracted mandibular first molar teeth were randomly assigned to 4 groups (n = 20) according to the endodontic access cavity shape and the single file system used for root canal preparation (reciprocating motion with the RCP B and rotary motion with the OC): TEC-RPC B, TEC-OC, CEC-RPC B, and CEC-OC. The apically extruded debris during preparation was collected in Eppendorf tubes. The amount of extruded debris was quantified by subtracting the weight of the empty tubes from the weight of the Eppendorf tubes containing the debris. Data were analyzed using 1-way analysis of variance with the Tukey post hoc test. The level of significance was set at p < 0.05. Results: The CEC-RPC B group showed more apical debris extrusion than the TEC-OC and CEC-OC groups (p < 0.05). There were no statistically significant differences in the amount of apical debris extrusion among the TEC-OC, CEC-OC, and TEC-RPC B groups. Conclusions: RPC B caused more apical debris extrusion in the CEC groups than did the OC single-file system. Therefore, it is suggested that the RPC B file should be used carefully in teeth with a CEC.

Effect of digital noise reduction on the accuracy of endodontic file length determination

  • Mehdizadeh, Mojdeh;Khademi, Abbas Ali;Shokraneh, Ali;Farhadi, Nastaran
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.185-190
    • /
    • 2013
  • Purpose: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Materials and Methods: Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO #08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (${\alpha}=0.05$). Results: Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P<0.05). There were no significant differences between the measurement accuracy of the original and enhanced images (P>0.05). Conclusion: Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

Study of endodontic working length of Korean posterior teeth (한국인의 구치부 근관작업장에 관한 연구)

  • Kim, Jeong-Yeob;Lee, Sang-Hoon;Lee, Gwang-Hee;Park, Sang-Hyuk
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.429-435
    • /
    • 2010
  • Objectives: The aim of this study was to investigate average working lengths of Korean posterior teeth and evaluate validity of endodontic file length. Materials and Methods: The endodontic working length of the posterior teeth of 670 Korean patients were measured than each mean value and standard deviation were investigated than the frequency deviation and standard deviation per each length were calculated. Results: Among the canals of premolar, 66.5% of canal length was marked under 20 mm by endodontic working length and 95.4% could be measured under 22 mm and Among the canals of molars, 95.5% of canal length was marked under 20 mm endodontic working length. Conclusions: With the result of measurement of endodontic working length of premolars of Korean, it suggested that 23 mm endodontic file is more proper than the 21 mm and 25 mm file on the market.

Investigation of fracture prevalence of instruments used in root canal treatments at a faculty of dentistry: a prospective study

  • Mehmet Eskibaglar;Merve Yeniceri Ozata;Mevlut Sinan Ocak;Faruk Oztekin
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.4
    • /
    • pp.38.1-38.10
    • /
    • 2023
  • Objectives: The aim of this study was to examine the use of hand or rotary files by pre-graduation (fourth- and fifth-year) and postgraduate students in endodontic treatments and to determine the incidence of file fracture and the management of cases with broken instruments. Materials and Methods: A total of 2,168 teeth undergoing primary endodontic treatment were included in this study. It was determined that 79 of these teeth resulted in broken tools. In the case of broken tools, the education level of the treating clinician, the tooth that was being treated, the canal and fracture level, the curvature of the tooth and the management of the broken instrument were recorded. Periapical radiographs of the patients were used to calculate curvature following the Schneider method. Results: There was no significant difference in the incidence of broken tools according to education level (p > 0.05). The incidence of file fracture in molar teeth (73.4%) was higher than in other teeth (p < 0.05). More files were broken in the mandibular molar MB canal (20.25%) and in the apical third of the canals (72.1%). The risk of instrument fracture was high in teeth with moderate (44.3%) and severe (38%) curvature canals. The management of apically broken (80%) files mostly involved lefting (p < 0.05). Conclusions: There was no statistically significant difference between fourth-year students, fifth-year students and postgraduate students in terms of instrument fracture.

Current clinical practice of endodontic irrigation (파일이 닿지 않는 곳. 어떻게 세척할 것인가!)

  • Seo, Minseock
    • The Journal of the Korean dental association
    • /
    • v.56 no.10
    • /
    • pp.556-566
    • /
    • 2018
  • Whether you use a hand file or an engine-driven file, you cannot remove bacteria completely from the root canal by mechanical work alone. If the root canal is well cleaned, endodontic irrigants will well penetrate into these areas that will not be mechanically accessible. It will decompose and remove the biofilm and also remove the smear layer to reach the dentinal tubule. Clinicians who are not yet using NaOCl as their primary irrigant, should be aware that there are no other irrigants that offer all the benefits of NaOCl and are inexpensive. Clinicians may be reluctant to use it because of concern about NaOCl accident, but this possibility is extremely low if used with caution.

  • PDF

Endodontic treatment of mandibular molar with root dilaceration using Reciproc single-file system

  • Meireles, Daniely Amorin;Bastos, Mariana Mena Barreto;Marques, Andre Augusto Franco;Garcia, Lucas Da Fonseca Roberti;Sponchiado, Emilio Carlos Junior
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.3
    • /
    • pp.167-171
    • /
    • 2013
  • Biomechanical preparation of root canals with accentuated curvature is challenging. New rotatory systems, such as Reciproc, require a shorter period of time to prepare curved canals, and became a viable alternative for endodontic treatment of teeth with root dilaceration. Thus, this study aimed to report a clinical case of endodontic therapy of root with accentuated dilaceration using Reciproc single-file system. Mandibular right second molar was diagnosed as asymptomatic irreversible pulpitis. Pulp chamber access was performed, and glide path was created with #10 K-file (Dentsply Maillefer) and PathFile #13, #16 and #19 (Dentsply Maillefer) up to the temporary working length. The working length measured corresponded to 20 mm in the mesio-buccal and mesio-lingual canals, and 22 mm in the distal canal. The R25 file (VDW GmbH) was used in all the canals for instrumentation and final preparation, followed by filling with Reciproc gutta-percha cones (VDW GmbH) and AH Plus sealer (Dentsply Maillefer), using thermal compaction technique. The case has been receiving follow-up for 6 mon and no painful symptomatology or periapical lesions have been found. Despite the difficulties, the treatment could be performed in a shorter period of time than the conventional methods.

Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using micro-computed tomography

  • Lee, Woo-Jin;Baek, Seung-Ho;Bae, Kwang-Sik
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.597-598
    • /
    • 2003
  • I. Objectives Endodontic success depends on thoroughly cleaned and completely obturated root canal system. Effective cleaning and obturation will be achieved by well shaped canal. Numerous methodologies evaluating the efficacy and safety of canal preparation has been developed and the use of micro-computed tomography(MCT) in endodontic research is one of the latest innovations. This scientific tools could overcome the inherent limitations of other methodologies, and possesses the ability to visualize morphological characteristics in a detailed and accurate manner without destruction of the tooth and offers reproducible data in all three dimensions. The purpose of this study was to determine the optimal master apical file size with less transportation and more efficiency in removing the infected dentin. For this purpose we evaluated the transportation of canal center and change of untouched area after preparation sequentially from #25 file through #40 file with 3 different instruments:Stainless steel(SS) K-type hand instruments(MANI, Japan), ProFile.04 instruments (Dentply Tulsa Dental, USA) and Lightspeed instruments(Lightspeed Technology, San Antonio, USA) using micro-computed tomography.(omitted)

  • PDF

Comparison of apical extrusion of intracanal bacteria by various glide-path establishing systems: an in vitro study

  • Dagna, Alberto;El Abed, Rashid;Hussain, Sameeha;Abu-Tahun, Ibrahim H;Visai, Livia;Bertoglio, Federico;Bosco, Floriana;Beltrami, Riccardo;Poggio, Claudio;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.316-323
    • /
    • 2017
  • Objectives: This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Materials and Methods: Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). Results: The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups (p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. Conclusions: All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.