DOI QR코드

DOI QR Code

Endodontic treatment of mandibular molar with root dilaceration using Reciproc single-file system

  • Received : 2013.04.17
  • Accepted : 2013.06.08
  • Published : 2013.08.30

Abstract

Biomechanical preparation of root canals with accentuated curvature is challenging. New rotatory systems, such as Reciproc, require a shorter period of time to prepare curved canals, and became a viable alternative for endodontic treatment of teeth with root dilaceration. Thus, this study aimed to report a clinical case of endodontic therapy of root with accentuated dilaceration using Reciproc single-file system. Mandibular right second molar was diagnosed as asymptomatic irreversible pulpitis. Pulp chamber access was performed, and glide path was created with #10 K-file (Dentsply Maillefer) and PathFile #13, #16 and #19 (Dentsply Maillefer) up to the temporary working length. The working length measured corresponded to 20 mm in the mesio-buccal and mesio-lingual canals, and 22 mm in the distal canal. The R25 file (VDW GmbH) was used in all the canals for instrumentation and final preparation, followed by filling with Reciproc gutta-percha cones (VDW GmbH) and AH Plus sealer (Dentsply Maillefer), using thermal compaction technique. The case has been receiving follow-up for 6 mon and no painful symptomatology or periapical lesions have been found. Despite the difficulties, the treatment could be performed in a shorter period of time than the conventional methods.

Keywords

References

  1. Prichard J. Rotation or reciprocation: a contemporary look at NiTi instruments? Br Dent J 2012;212:345-346. https://doi.org/10.1038/sj.bdj.2012.268
  2. Elayouti A, Chu AL, Kimionis I, Klein C, Weiger R, Lost C. Efficacy of rotary instruments with greater taper in preparing oval root canals. Int Endod J 2008;41:1088- 1092. https://doi.org/10.1111/j.1365-2591.2008.01475.x
  3. Marchesan MA, Arruda MP, Silva-Sousa YT, Saquy PC, Pecora JD, Sousa-Neto MD. Morphometrical analysis of cleaning capacity using nickel-titanium rotary instrumentation associated with irrigating solutions in mesiodistal flattened root canals. J Appl Oral Sci 2003;11:55-59. https://doi.org/10.1590/S1678-77572003000100010
  4. Yared G. Canal preparation using only one Ni-Ti rotary instrument: preliminary observations. Int Endod J 2008;41:339-344. https://doi.org/10.1111/j.1365-2591.2007.01351.x
  5. Hulsmann M, Peters OA, Dummer PMH. Mechanical preparation of root canals: shaping goals, techniques and means. Endod Topics 2005;10:30-76. https://doi.org/10.1111/j.1601-1546.2005.00152.x
  6. Alapati SB, Brantley WA, Iijma M, Clark WA, Kovarik L, Buie C, Liu J, Ben Johnson W. Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments. J Endod 2009;35:1589-1593. https://doi.org/10.1016/j.joen.2009.08.004
  7. Gutmann JL, Gao Y. Alteration in the inherent metallic and surface properties of nickel-titanium root canal instruments to enhance performance, durability and safety: a focussed review. Int Endod J 2012;45:113-128. https://doi.org/10.1111/j.1365-2591.2011.01957.x
  8. Kim HC, Kwak SW, Cheung GS, Ko DH, Chung SM, Lee W. Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion: Reciproc versus WaveOne. J Endod 2012;38: 541-544. https://doi.org/10.1016/j.joen.2011.11.014
  9. Gavini G, Caldeira CL, Akisue E, Candeiro GT, Kawakami DA. Resistance to flexural fatigue of Reciproc R25 files under continuous rotation and reciprocating movement. J Endod 2012;38:684-687. https://doi.org/10.1016/j.joen.2011.12.033
  10. Burklein S, Hinschitza K, Dammaschke T, Schafer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J 2012;45:449-461. https://doi.org/10.1111/j.1365-2591.2011.01996.x
  11. Roane JB, Sabala CL, Duncanson MG Jr. The 'balanced force' concept for instrumentation of curved canals. J Endod 1985;11:203-211. https://doi.org/10.1016/S0099-2399(85)80061-3
  12. De-Deus G, Moreira EJ, Lopes HP, Elias CN. Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement. Int Endod J 2010;43:1063- 1068. https://doi.org/10.1111/j.1365-2591.2010.01756.x
  13. Burklein S, Schafer E. Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems. J Endod 2012;38:850-852. https://doi.org/10.1016/j.joen.2012.02.017
  14. Pedulla E, Grande NM, Plotino G, Gambarini G, Rapisarda E. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments. J Endod 2013;39:258-261. https://doi.org/10.1016/j.joen.2012.10.025
  15. Bürklein S, Benten S, Schäfer E. Shaping ability of different single-file systems in severely curved root canals of extracted teeth. Int Endod J 2013;46:590- https://doi.org/10.1111/iej.12037
  16. Yoo YS, Cho YB. A comparison of the shaping ability of reciprocating NiTi instruments in simulated curved canals. Restor Dent Endod 2012;37:220-227. https://doi.org/10.5395/rde.2012.37.4.220
  17. Lim YJ, Park SJ, Kim HC, Min KS. Comparison of the centering ability of Wave.One and Reciproc nickeltitanium instruments in simulated curved canals. Restor Dent Endod 2013;38:21-25. https://doi.org/10.5395/rde.2013.38.1.21
  18. Gergi R, Rjeily JA, Sader J, Naaman A. Comparison of canal transportation and centering ability of twisted files, Pathfile-ProTaper system, and stainless steel hand K-files by using computed tomography. J Endod 2010;36:904-907. https://doi.org/10.1016/j.joen.2009.12.038
  19. Berutti E, Cantatore G, Castellucci A, Chiandussi G, Pera F, Migliaretti G, Pasqualini D. Use of nickel-titanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals. J Endod 2009;35:408-412. https://doi.org/10.1016/j.joen.2008.11.021
  20. Michelotto AL, Moura-Netto C, Araki AT, Akisue E, Moura AA, Sydney GB. In vitro analysis of thermocompaction time and gutta-percha type on quality of main canal and lateral canals filling. Braz Oral Res 2010;24:290-295. https://doi.org/10.1590/S1806-83242010000300006

Cited by

  1. Surface Characteristics of Reciprocating Instruments Before and After Use - A SEM Analysis vol.26, pp.2, 2015, https://doi.org/10.1590/0103-6440201300208