• 제목/요약/키워드: End Mismatch

검색결과 49건 처리시간 0.019초

A 12b 100 MS/s Three-Step Hybrid Pipeline ADC Based on Time-Interleaved SAR ADCs

  • Park, Jun-Sang;An, Tai-Ji;Cho, Suk-Hee;Kim, Yong-Min;Ahn, Gil-Cho;Roh, Ji-Hyun;Lee, Mun-Kyo;Nah, Sun-Phil;Lee, Seung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권2호
    • /
    • pp.189-197
    • /
    • 2014
  • This work proposes a 12b 100 MS/s $0.11{\mu}m$ CMOS three-step hybrid pipeline ADC for high-speed communication and mobile display systems requiring high resolution, low power, and small size. The first stage based on time-interleaved dual-channel SAR ADCs properly handles the Nyquist-rate input without a dedicated SHA. An input sampling clock for each SAR ADC is synchronized to a reference clock to minimize a sampling-time mismatch between the channels. Only one residue amplifier is employed and shared in the proposed ADC for the first-stage SAR ADCs as well as the MDAC of back-end pipeline stages. The shared amplifier, in particular, reduces performance degradation caused by offset and gain mismatches between two channels of the SAR ADCs. Two separate reference voltages relieve a reference disturbance due to the different operating frequencies of the front-end SAR ADCs and the back-end pipeline stages. The prototype ADC in a $0.11{\mu}m$ CMOS shows the measured DNL and INL within 0.38 LSB and 1.21 LSB, respectively. The ADC occupies an active die area of $1.34mm^2$ and consumes 25.3 mW with a maximum SNDR and SFDR of 60.2 dB and 69.5 dB, respectively, at 1.1 V and 100 MS/s.

45${\circ}$ 문합각을 가진 동맥과 PTFE 단측 문합의 유한요소해석 (Finite Element Analysis of the Artery and PTFE End-To-Side Anastomosis with 45${\circ}$ Anastomotic angle)

  • 한근조;김형태;안성찬;신정욱;김영호
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권3호
    • /
    • pp.253-259
    • /
    • 1997
  • Von Mises stress and compliance distribution was evaluated using a finite element analysis on the anastomosis of an artery with length of 20mm(z direction, along the horizental artery), inner diameter of 4mm, thickness fo 0.5mm and a PTFE graft with length of 5.7mm, inner diameter of 2mm, thickness of 0.2mm when anastomotic angle was $45^{\circ}$ and inner pressure of 1330 dyne/mm2 was applied inside the 2 conduits. From the analysis results were obtained as follows. (1) Artery diameter increased in both horizontal x(along the length of artery) and vertical y(perpendicular to the length of artery)directions and the magnitude of that in x direction was bigger than that in y direction. (2) The compliance was maximum on the anastomosis, especially on that with acute angle. The reduction of compliance was observed from the anastomosis area to the either right or left end. (3) The equivalent stress was maximum on top in the y direction and minimum on the nodes apart $110^{\circ}$ in circumferential direction from the top. (4) The equivalent stress was maximum in t도 vicinity of anastomosis with acute angle along the longitudinal direction of the artery. This trend was also observed along the PTFE graft.

  • PDF

Front-End Module of 18-40 GHz Ultra-Wideband Receiver for Electronic Warfare System

  • Jeon, Yuseok;Bang, Sungil
    • Journal of electromagnetic engineering and science
    • /
    • 제18권3호
    • /
    • pp.188-198
    • /
    • 2018
  • In this study, we propose an approach for the design and satisfy the requirements of the fabrication of a small, lightweight, reliable, and stable ultra-wideband receiver for millimeter-wave bands and the contents of the approach. In this paper, we designed and fabricated a stable receiver with having low noise figure, flat gain characteristics, and low noise characteristics, suitable for millimeter-wave bands. The method uses the chip-and-wire process for the assembly and operation of a bare MMIC device. In order to compensate for the mismatch between the components used in the receiver, an amplifier, mixer, multiplier, and filter suitable for wideband frequency characteristics were designed and applied to the receiver. To improve the low frequency and narrow bandwidth of existing products, mathematical modeling of the wideband receiver was performed and based on this spurious signals generated from complex local oscillation signals were designed so as not to affect the RF path. In the ultra-wideband receiver, the gain was between 22.2 dB and 28.5 dB at Band A (input frequency, 18-26 GHz) with a flatness of approximately 6.3 dB, while the gain was between 21.9 dB and 26.0 dB at Band B (input frequency, 26-40 GHz) with a flatness of approximately 4.1 dB. The measured value of the noise figure at Band A was 7.92 dB and the maximum value of noise figure, measured at Band B was 8.58 dB. The leakage signal of the local oscillator (LO) was -97.3 dBm and -90 dBm at the 33 GHz and 44 GHz path, respectively. Measurement was made at the 15 GHz IF output of band A (LO, 33 GHz) and the suppression characteristic obtained through the measurement was approximately 30 dBc.

유량 파형이 데이퍼형 인조혈관 유동에 미치는 영향 (The Effects of Flow Wave form on the Flow Characteristics in Tapered Vascular Grafts)

  • 이현철;석광원;전철완;이진;이영석;김성환
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권3호
    • /
    • pp.337-346
    • /
    • 1996
  • The patency of small size vascular grafts is poor, and the blood flow characteristics in the artery graft anastomosis are suspected as one of the important factors influencing intimal hyperplasia. Disturbed flow patterns caused by sixte and compliance mismatch generate unfavorable flow environment which promotes intimal thickening. Tapered vascular yuts are suggested in order to reduce sudden expansion near the anastomosis. The photochromic flow visualization method is used to measure the flout fields in the end-to-end anastomosis model under the carotid and femoral artery flow wave form. The results show that flow disturbance near the anastomosis is diminished in the tapered grafts comparing to the tubular graft. As the divergent ang1e decreases, we can reduce the low and oscillatory wall shear stress zone which is prone to intimal hyperplasia. The flow wave form effects the wall shear rate dis- tribution significantly. The steep deceleration and back flow in the femoral flow wAve form cause low mean wall shear rate and high oscillatory shear index.

  • PDF

자동차 엔진룸용 전장품 유무연 솔더 접합부의 열화특성 (Degradation Characteristics of Eutectic and Pb-free Solder Joint of Electronics mounted for Automotive Engine)

  • 김아영;홍원식
    • Journal of Welding and Joining
    • /
    • 제32권3호
    • /
    • pp.74-80
    • /
    • 2014
  • Due to environmental regulations (RoHS, WEEE and ELV) of the European Union, electronics and automotive electronics have to eliminate toxic substance from their devices and system. Especially, reliability issue of lead-free solder joint is increasing in car electronics due to ELV (End-of-Life Vehicle) banning from 2016. We have prepared engine control unit (ECU) modules soldered with Sn-40Pb and Sn-3.0Ag-0.5Cu (SAC305) solders, respectively. Degradation characteristics of solder joint strength were compared with various conditions of automobile environment such as cabin and engine room. Thermal cycle test (TC, $-40^{\circ}C$ ~ ($85^{\circ}C$ and $125^{\circ}C$), 1500 cycles) were conducted with automotive company standard. To compare shear strength degradation rate with eutectic and Pb-free solder alloy, we measured shear strength of chip components and its size from cabin and engine ECU modules. Based on the TC test results, finally, we have known the difference of degradation level with solder alloys and use environmental conditions. Solder joints degradation rate of engine room ECU is superior to cabin ECU due to large CTE (coefficient of thermal expansion) mismatch in field condition. Degradation rate of engine room ECU is 50~60% larger than cabin room electronics.

PZT 세라믹 레조네이터 무연솔더 접합부의 열-기계적 피로 가속수명 (Accelerated Thermo-Mechanical Fatigue Life of Pb-Free Solder Joints for PZT Ceramic Resonator)

  • 홍원식;박노창;오철민
    • 한국재료학회지
    • /
    • 제19권6호
    • /
    • pp.337-343
    • /
    • 2009
  • In this study, we optimized Pb-free Sn/Ni plating thickness and conditions were optimized to counteract the environmental regulations, such as RoHS and ELV(End-of Life Vehicles). The $B_{10}$ life verification method was also suggested to have been successful when used with the accelerated life test(ALT) for assessing Pb-free solder joint life of piezoelectric (PZT) ceramic resonator. In order to evaluate the solder joint life, a modified Norris-Landzberg equation and a Coffin-Manson equation were utilized. Test vehicles that were composed of 2520 PZT ceramic resonator on FR-4 PCB with Sn-3.0Ag-0.5Cu for ALT were manufactured as well. Thermal shock test was conducted with 1,500 cycles from $(-40{\pm}2)^{\circ}C$ to $(120{\pm}2)^{\circ}C$, and 30 minutes dwell time at each temperature, respectively. It was discovered that the thermal shock test is a very useful method in introducing the CTE mismatch caused by thermo-mechanical stress at the solder joints. The resonance frequency of test components was measured and observed the microsection views were also observed to confirm the crack generation of the solder joints.

4차 산업혁명시대 무역인력양성 방향과 전략에 관한 연구 (The Direction & Strategy of Human Resources Development in Global Business Practise in the 4th Industrial Revolution)

  • 조원길
    • 무역학회지
    • /
    • 제44권4호
    • /
    • pp.67-85
    • /
    • 2019
  • This study analyzes the trade issues and curriculum issues of universities in the 4th Industrial Revolution era with the aim of finding strategies to improve the curriculum of international commerce and to cultivate trade manpower by matching them with the trade job competencies required by trade enterprises. To this end, trade college students, GTEP partners, industry-academia partners, and expert groups of N university were asked to provide information on trade curriculum for the current curriculum. The resulting data were analyzed by questionnaire frequency analysis and FGI method to reveal that both students and graduates are interested in improving the trade curriculum of the university, and that companies are also demanding talents who are responsible for the comprehensive process of trade practice and can perform sincerely and comprehensively. Therefore, we have established a new curriculum that is suitable for the 4th industrial age, opened a certificate acquisition course suitable for the needs of the company, and developed the commercial practice, trade simulation, capstone design, and PBL teaching method. Ways are suggesting to reduce mismatch between universities and companies.

김(Pyropia spp.) 가공식품에 포함된 녹조 파래류(Ulva spp.) 동정을 위한 분자마커 개발 및 적용 (Development and Application of Molecular Markers for Identifying Ulva species in Commercial Pyropia Seafoods)

  • 하동수;황미숙;김승오;이지은;이상래
    • 한국수산과학회지
    • /
    • 제47권5호
    • /
    • pp.522-526
    • /
    • 2014
  • Pyropia, economic red algae species, have been cultivated in Korea (referred to as 'gim'), Japan ('nori'), and China ('zicai') for over 300 years. Vegetable seaweed Pyropia species are sold in the public markets in various forms as commercial seafoods. In Korea, two kinds of Pyropia seafood made with species of Pyropia and Ulva (sea lettuce, referred to as 'parae') are also sold. These are referred to as 'parae-gim' (with Pyropia spp. and U. linza) and 'gamtaegim' (with Pyropia spp. and U. prolifera). There is currently no method for identifying the seaweed species that comprise Pyropia seafood products. Therefore, we developed novel molecular markers to identify Ulva species in commercial Pyropia seafoods. Based on rbcL molecular markers, we identified informative characteristics to discriminate U. linza and U. prolifera as seafood ingredients. Moreover, PCR with 3'-end mismatch primers successfully isolated the specific rbcL sequences of U. linza and U. prolifera from Pyropia seafoods. Therefore, our novel molecular markers will be useful for identifying the ingredient species of commercial seafoods.

Molecular discrimination of Panax ginseng cultivar K-1 using pathogenesis-related protein 5 gene

  • Wang, Hongtao;Xu, Fengjiao;Wang, Xinqi;Kwon, Woo-Saeng;Yang, Deok-Chun
    • Journal of Ginseng Research
    • /
    • 제43권3호
    • /
    • pp.482-487
    • /
    • 2019
  • Background: The mixed-cultivation of different Panax ginseng cultivars can cause adverse effects on stability of yield and quality. K-1 is a superior cultivar with good root shape and stronger disease resistance. DNA markers mined from functional genes are clearly desirable for K-1, as they may associate with major traits and can be used for marker-assisted selection to maintain the high quality of Korean ginseng. Methods: Five genes encoding pathogenesis-related (PR) proteins of P. ginseng were amplified and compared for polymorphism mining. Primary, secondary, and tertiary structures of PR5 protein were analyzed by ExPASy-ProtParam, PSSpred, and I-TASSER methods, respectively. A coding single nucleotide polymorphism (SNP)-based specific primer was designed for K-1 by introducing a destabilizing mismatch within the 3' end. Allele-specific polymerase chain reaction (PCR) and real-time allele-specific PCR assays were conducted for molecular discrimination of K-1 from other cultivars and landraces. Results: A coding SNP leading to the modification of amino acid residue from aspartic acid to asparagine was exploited in PR5 gene of K-1 cultivar. Bioinformatics analysis showed that the modification of amino acid residue changed the secondary and tertiary structures of the PR5 protein. Primer KSR was designed for specific discrimination of K-1 from other ginseng cultivars and landraces. The developed real-time allele-specific PCR assay enabled easier automation and accurate genotyping of K-1 from a large number of ginseng samples. Conclusion: The SNP marker and the developed real-time allele-specific PCR assay will be useful not only for marker-assisted selection of K-1 cultivar but also for quality control in breeding and seed programs of P. ginseng.

2008-2017 패널분석 결과에 나타난 개인-직무 적합성과 직무만족 간의 관계 (A Study on the Relationship between Person-Job Fit and Job Satisfaction shown in the Panel Data for 2008-2017)

  • 취칭칭;이정현
    • 아태비즈니스연구
    • /
    • 제10권4호
    • /
    • pp.87-118
    • /
    • 2019
  • The purpose of this study is to examine the effects of person-job fit, which consists of educational fit and skill fit, on employees' intrinsic job satisfaction. To the end, the 10-year balanced panel data of the Korean Labor and Income Panel Study(KLIPS) by the Korea Labor Institute (KLI) for 2008-2017 are utilized. This study analyzes 12,730 observations by 1,273 employees by using fixed effect model, random effect model, and pooled OLS estimation method. The empirical results are as follows: First, it is founded that educational fit and skill fit seem affect job satisfaction positively. Second, the negative effects of over-education are clear and the negative effects of under-education are unclear, while the effects of over-skilled and under-skilled are insignificant statistically. Third, the results imply that the size of effect of over-education on intrinsic job satisfaction is larger than that of the effect of over-skilled. Forth, it is shown that the use of fixed effect model is more effective and trustworthy than that of random effect model and pooled OLS estimation method, implying that the effect size of coefficients which are estimated by pooled OLS method and random effect model are likely over-estimated. The empirical results above imply that firms and employees should focus on solving over-education issue before all in order to enhance employees' job satisfaction and it is needed to monitor regularly whether systemic job assignment process is done based on the employees' educational attainment and skill level and to provide more chances for job re-allocation and job rotation.