• Title/Summary/Keyword: Enamel roughness

Search Result 39, Processing Time 0.029 seconds

SURFACE ROUGHNESS AND MICROLEAKAGE OF CLASS V COMPOSITE RESTORATIONS : EFFECT OF SURFACE SEALING (치경부 5급 와동 수복물의 표면 거칠기와 미세누출에 관한 연구 : 표면 전색의 효과)

  • Kim, Min-Jeong;Lee, Mi-Jeong;Yu, Mi-Kyung;Park, Soo-Joung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.22-30
    • /
    • 2005
  • The purpose of this study was to compare the effect of surface sealing materials on microleakage and surface roughness in Class V composite restorations. Twenty five standardized Class V cavity preparations were made on the facial surface of human premolars and were randomly assigned to 5 groups. The teeth were restored with Z-250 after applying Single Bond. Following 7 days storage in distilled water at $37^{\circ}C$, the restorations were sealed as following systems : No sealing ; Single Bond Adhesive ; Biscover ; Fortify ; Optiguard. Then, toothbrush abrasion test was conducted using a wear testing machine. Surface roughness was measured by means of profilometer before and after toothbrushing and the results were statistically analysed by using a paired t-test and ANOVA. The bonded interfaces and the changes of surface roughness were examined by SEM. For microleakage test, specimens were stained in a $2\%$ methylene blue solution, then longitudinally sectioned and analyzed for leakage at occlusal and cervical interfaces using stereomicroscope. The results were statistically analysed by using a Kruskal-Wallis and Mann-Whitney U test. Surface roughness was increasing in all groups after toothbrushing, but no statistically significant differences. In SEM observation, surface sealant was partially retained and partially detached in bonded interfaces. Especially, microgap was identified in cervical margins. In microleakage test, there was better seal in the enamel region and a significant difference between groups at occlusal margin. Control group and Single Bond group had significantly better marginal seal at enamel margin than cervical margin.

The Effect of Carbonated Water on Bovine Enamel Erosion and Plaque Adhesion (시판 탄산수에 의한 우치 법랑질 침식과 침착 효과)

  • Lim, Do-Seon;Ban, Yu-Hee;Min, Young-Eyn;Park, Jin-Joo;Yu, Ye-Jin;In, So-Ra;Ju, Hyun-Ji;Jung, Sun-Young;Hwang, Young Sun
    • Journal of dental hygiene science
    • /
    • v.15 no.4
    • /
    • pp.437-444
    • /
    • 2015
  • Due to the attractive benefits with regard to bone health, digestion, and hydration, carbonated water consumption have rapidly grown over the past few years. However, the acidic drink has latent potential for enamel erosion. The most experimental studies about the enamel erosion have focused on the carbonated beverages with sugar and artificial sweeteners. Here, we determined the enamel erosion potential by commercially available carbonated waters with bovine teeth. The erosion was verified by pH value, calcium concentration, and scanning electron microscope. Then plaque accumulation by bacterial adhesion was determined on the enamel erosion surface to measure roughness. In the present study, we observed that the increased calcium content after being immersed in carbonated waters result from the overall enamel erosion. There were no significant differences between general carbonated waters and mineral waters for erosive capacity. Therefore, commercially available carbonated waters are potentially erosive. In addition, oral bacteria strongly adhered to the erosive enamel surfaces thereby facilitating the development of dental plaque. Thus, it is urgently necessary to provide food safety information on the carbonated water as acidic drink to prevent the enamel erosion.

EFFECTS OF VARIOUS ETCHING TIMES ON DEPTH OF ETCH AND SHEAR BOND STRENGTH OF AN ORTHODONTIC RESIN TO BOVINE ENAMEL (부식시간이 소의 법랑질 부식깊이와 교정용 레진의 전단결합강도에 미치는 영향)

  • Kim, Jeong-Hoon;Lee, Ki-Soo;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.23 no.1 s.40
    • /
    • pp.75-88
    • /
    • 1993
  • Recent reports indicate that shorter etching times than 60 seconds can be adopted without affecting the bond strength and clinical disadvantages. The purpose of this in vitro study was to compare the shear bone strength and to measure depth of etch at different etching time length. One hundred and eight extracted bovine lower central incisors were embedded each in a tooth cup with cold-cure acrylic resin. The facial surfaces of the teeth were ground wet with 600-, 800-, 1000-, and 1200-grit Sic papers, and finally polished with a water slurry of extrafine silicon carbide powder, washed with tap water, and dried with hot air. Nine groups of nine prepared teeth were etched with a commercial($38\%$ phosphoric acid solution) for 0, 5, 10, 15, 20, 30, 60, 90, and 120 seconds, respectively, rinsed with tap water, and dried with hot air. One conditioned teeth from every group was selected randomly for the scanning electron microscopic examination, and the remaining eight teeth of the groups were used for measuring the push shear bond strength after bonding brackets and immensing them in the $36.5^{\circ}C$ water for 24 hours. Another nine groups of three teeth were used for measuring the depth of etch and surface roughness with a surface profilometer. after pieces of adhesive tape of 3mm inner diameter positioned on the ground enamel surfaces, and etched with the above mentioned. The data obtained form the above expeiments were analysed statistically with one way ANOVA and Dunkan's multiple range test with the $95\%$ confidence level. The results and conclusion of the study were as follows; 1. The results of shear bond strength for the given experimental etching times were not statistically different, but showed the tendency of decreasing shear bone strength after over 60 seconds etching times. 2. On the scanning election microscopic examination, it was observed that the morphological patterns of etched enamel surface for 5 to 20 seconds were similar and consitent, and those for 30 to 120 seconds showed increasing over-etched patterns depending on the length of etching times. 3. The depth of etch was increased almost proportionally by the length of etching times, but it was not associated with the shear bond strength. 4. The surface roughness increased depending on the length of etching times, but it was not associated with the shear bond strength. 5. This experiment indicated that proper etching time with $38\%$ phosphoric acid solution is in the range of 5 to 30 seconds.

  • PDF

Characteristics of the molar surface after removal of cervical enamel projections: comparison of three different rotating instruments

  • Ko, Min-Jeong;Cho, Chan-Myung;Jeong, Seong-Nyum
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.2
    • /
    • pp.107-115
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate and compare tooth surface characteristics in extracted human molars after cervical enamel projections (CEPs) were removed with the use of three rotating instruments. Methods: We classified 60 extracted molars due to periodontal lesion with CEPs into grade I, II, or III, according to the Masters and Hoskins' criteria. Each group contained 20 specimens. Three rotating instruments were used to remove the CEPs: a piezoelectric ultrasonic scaler, a periodontal bur, and a diamond bur. Tooth surface characteristics before and after removal of the projections were then evaluated with scanning electron microscopy (SEM). We analyzed the characteristics of the tooth surfaces with respect to roughness and whether the enamel projections had been completely removed. Results: In SEM images, surfaces treated with the diamond bur were smoothest, but this instrument caused considerable harm to tooth structures near the CEPs. The piezoelectric ultrasonic scaler group produced the roughest surface but caused less harm to the tooth structure near the furcation. In general, the surfaces treated with the periodontal bur were smoother than those treated with the ultrasonic scaler, and the periodontal bur did not invade adjacent tooth structures. Conclusions: For removal of grade II CEPs, the most effective instrument was the diamond bur. However, in removing grade III projections, the diamond bur can destroy both adjacent tooth structures and the periodontal apparatus. In such cases, careful use of the periodontal bur may be an appropriate substitute.

COMPARISON OF THE ABRASIVENESS OF CEROMERS ON ENAMEL AND GOLD ALLOY (Ceromer의 법랑질 및 금합금에 대한 마모도 비교)

  • Jung Hee-Kyung;Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.96-104
    • /
    • 2001
  • This study was performed to compare the abrasiveness and wear resistance of several restorative materials occluding enamel and gold alloy. Intact labial surface of bovine incisor and the plain portion of type III gold alloy were used as plate specimens, and pin specimens were fabricated using $Artglass^{(R)},\;Targis^{(R)},\;Sculpture^{(R)}$. After two-body wear test using pin and plate model, amount of vertical height loss of plate and pin specimens were measured and statically analyzed. The amount of vertical height loss of plate specimens against pin specimens were measured by a roughness measurement instrument. The amount of vertical height loss of pin specimens against plate specimens were measured by an image analyzing program after taking scanning electron micrographs of pin specimens. The results were as following. 1. As fir the amount of enamel wear. gold group showed least amount of wear. There was no significant difference among Sculpture, Targis and Artglass groups(p<0.05). 2. As for the amount of gold wear Sculpture group standed first and Targis and Artglass group followed respectively, and there was significant difference between Sculpture and Artglass groups(p<0.05). 3. As for the amount of restorative materials against enamel, Artglass group showed greatest, and there was no significant difference among gold. Sculpture, Targis groups(p<0.05). 4. As for the amount of restorative materials against gold, Artglass group standed first and Targis and Sculpture group followed respectively, and there was significant difference among each groups(p<0.05).

  • PDF

Erosive Effect and Color of Mouthrinsing Solutions on Enamel Surface (시판중인 구강양치용액의 법랑질 표면의 착색과 침식에 미치는 영향)

  • Jeong, Kyung-Yi;Lee, Hye-Jin;Park, Young-Nam
    • Journal of dental hygiene science
    • /
    • v.11 no.5
    • /
    • pp.397-404
    • /
    • 2011
  • The aims of this study were to evaluate the effect of native acidity upon dental hard tissues by measuring pH in mouth-rinse, which is on the market, and to evaluate even influence of dental stain caused by mouse-rinse given using for a long time. The experimental group was used Garglin, Nextcare, Listerine, and Hexamedin. The control group was used sterile distilled water. As a result, pH was indicated to be low in Nextcare(4.70) and Listerine(4.16). In a change of color tone, $b^*$ value of indicating Yellow-blue showed the lower value than the early color tone in all groups. There was statistical significance in Nextcare and Listerine. ${\Delta}L^*$ value of indicating light -dark gets darker after using Nextcare, Listerine and Hexamedine. A change(VHN) in surface hardness of enamel showed reduction in surface hardness after 14 days in Nexcare and Listerine. As a result of confirming a change in enamel surface by using Scanning Electron Microscopy, the erosion aspect on the enamel surface could be confirmed in groups of Nexcare and Listerine. Ra value in surface roughness of enamel could be observed the enamel surface, which got rougher compared to other experimental groups.

Effect of Silver Diamine Fluoride and Sodium Fluoride Varnish on Remineralization in Artificially Induced Enamel Caries: An in vitro Study (Silver diamine fluoride와 sodium fluoride (NaF) 바니쉬의 법랑질 인공우식병소 재광화 효과)

  • Kim, Soyoung;Lee, Sangho;Lee, Nanyoung;Jih, Myeongkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.3
    • /
    • pp.266-276
    • /
    • 2020
  • The purpose of this study was to compare the remineralization effect of 38% silver diamine fluoride (SDF) and 5% sodium fluoride (NaF) varnish on artificially induced enamel caries. The present study standardized the physiochemical characteristics of the tooth structure using bovine teeth, realized the wash-off action of agents using a saliva, reproduced an environment similar to mouth through pH-cycling, and comparatively assessed the remineralization effect of 38% SDF and 5% NaF varnish in a non-destructive method using micro-CT. And the remineralized enamel surface structure was analyzed by scanning electron microscopy (SEM) and energy dispersive X-Ray spectroscopy (EDS). In both SDF and NaF varnish, mineral density (△Hounsfield unit value) and the volume of enamel restored to normal mineral density through remineralization gradually increased with time. And the SDF showed a much higher level of increase in mineral density at all depths and remineralized volume than NaF varnish. According to SEM analysis, the surface roughness decreased in the order of artificial saliva, NaF varnish and SDF. In addition, EDS analysis showed that silver ion was precipitated on the enamel surface in SDF group. In conclusion, SDF had a greater remineralization effect than NaF varnish on demineralized enamel.

In vitro Measurement of the Mechanical Properties of Resin Infiltrant: Viscosity, Penetration Pattern, Surface Roughness, Microhardness (초기 법랑질 우식 병소에 대한 Resin infiltrant의 점도, 침투 양상, 표면 조도 및 미세경도)

  • Hong, Seung-Hyun;Kim, Min-Jeong;Cho, Hye-Jin;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.81-90
    • /
    • 2011
  • In this study, we observed the penetration of the resin infiltrant into natural initial caries by SEM and CLSM, evaluated the pH and viscosity of resin infiltrant and several adhesives(All-bond 2, Scotchbond Multi-purpose, Clearfil SE bond), and measured the surface roughness and the microhardness on permanent teeth before and after applied resin infiltrant into initial enamel caries. The viscosity(Pa.s) was observed for resin infiltrant($0.173{\pm}0.012$), All-bond 2($0.754{\pm}0.030$), Scotchbond Multi-purpose($1.46{\pm}0.137$), and Clearfil SE bond($1.28{\pm}0.125$). The pH was measured for resin infiltrant (4.7), All-bond 2(7.5), Scotchbond Multi-purpose(8.2), and Clearfil SE bond(4.67). An application procedure of resin infiltrant increased the surface roughness and the microhardness insignificantly(p>0.05), when compared to non-applied specimens.

A Comparison of the Amount of Fluoride Ion Released and Remineralization Effect on the Initial Caries Lesion of the Various Fluoride Varnishes (시판중인 불소 바니쉬의 불소이온 유리량 및 초기우식병소의 재광화 효과 비교)

  • Lee, Kayoung;Lee, Sangho;Lee, Nanyoung;Jih, Myeongkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.443-451
    • /
    • 2016
  • Subjects of this study were : $FluoroDose^{(R)}$ (FD, Centrix Inc., USA), $Enamelast^{TM}$ (EL, Ultradent Product Inc., USA), $Clinpro^{TM}$ white varnish (CW, 3M ESPE, USA), $CavityShield^{TM}$ (CS, 3M ESPE, USA), V $varnish^{TM}$ (VV, Vericom, Korea), MI $varnish^{TM}$ (MI, GC, Japan). The amount of fluoride ion release was measured eight times during 168 hours to see change in accumulation with the course of time using a measuring instrument. And the remineralization rate was measured with Quantitative Light-induced Fluorescence (QLF). V $varnish^{TM}$ group and MI $varnish^{TM}$ group showed high remineralization rates with statistically significance while $CavityShield^{TM}$ group was the lowest rate of remineralization (p < 0.05). After that, several chosen samples were scanned through electron microscope (SEM). Demineralized enamel was observed as the number of enamel crystal was very small; enamel rods and crystals were highly protruding. Remineralized groups with fluoride varnishes show the decreasing tendency of the surface roughness compared to the demineralized enamel.

An in-vitro wear study of human enamel opposing heat-pressed ceramics (2종의 열가압 도재와 법랑질 간의 마모에 관한 연구)

  • Park, Chan-Yong;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.21-28
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the wear characteristics of human enamel opposing 2 heat-pressed ceramics (e.max Press and Empress Esthetic), conventional feldspathic porcelain (Ceramco 3) and type III gold alloy. Material and methods: Intact cusps of extracted premolars were used for enamel specimens. Five disk samples were made for each of two heat-pressed ceramics groups, conventional feldspathic porcelain group and type III gold alloy group. Wear tests were conducted in distilled water using a pin-on-disk tribometer. The amount of enamel wear was determined by weighing the enamel specimens before and after wear tests, and the weight was converted to volumes by average density. The wear tracks were analyzed by scanning electron microscopy and surface profilometer to elucidate the wear characteristics. Results: 1. Ceramco 3 led to the greatest amount of enamel wear followed by Empress Esthetic, e.max Press and type III gold alloy. However, there was no significant difference between Ceramco 3 and Empress Esthetic (P>.05), and there were also no significant differences among Empress Esthetic, e.max Press and type III gold alloy (P>.05). 2. The average surface roughness of e.max Press after wear test was smallest followed by Empress Esthetic and Ceramco 3, but there was no significant difference between Empress Esthetic and Ceramco 3 (P>.05). 3. There were no significant differences among the depth of wear tracks of all the groups (P>.05). The group that showed the largest width of wear track was Ceramco 3 followed by Empress Esthetic, e.max Press and type III gold alloy. However, there was no significant difference between e.max Press and Empress Esthetic (P>.05), and there was also no significant difference between Empress Esthetic and Ceramco 3 (P>.05). Conclusion: Within the limits of this study, heat-pressed ceramics were not more abrasive than conventional feldspathic porcelain.