• Title/Summary/Keyword: Empty can test

Search Result 41, Processing Time 0.02 seconds

Empty Can Test for Diagnosis of Supraspinatus Tear - Compare with Arthroscopic Finding - (극상근 파열에 대한 Empty Can Test의 진단적 가치 - 관절경 소견과 비교 -)

  • Moon Young Lae;You Jea Won;Kim Dong Hui
    • Clinics in Shoulder and Elbow
    • /
    • v.4 no.1
    • /
    • pp.13-16
    • /
    • 2001
  • Object: To determine the sensitivity, specificity, and positive and negative predictive values of an empty can test for diagnosing supraspinatus tendon tear. Methods: We reviewed 146 patients who have shoulder pain with limited active range of motion. We evaluated patients according to empty can test. Sensitivity, specificity, and positive and negative predictive values for supraspinatus test was estimated using arthroscopic evaluation. Results: A hundred and twenty-four of 127 cases with positive empty can test had supraspinatus tendon tear. Of 19 samples with negative empty can test, 15 had no supraspinatus tear. Sensitivity, specificity, and positive and negative predictive values for the empty can test were 97.6%, 83.3%, 97.6%, and 78.9%, respectively. Conclusions: Empty can test was found to have a high sensitivity and good positive predictive value in identifying the tear of rotator cuff tendon. We concluded that empty can test of the shoulder is a reliable diagnostic method which could be used for the diagnosis of rotator cuff tear.

  • PDF

What are Valuable Positive Signs of Supraspinatus Test for Diagnosis of Torn Rotator Cuff? - Comparison of Pain and Weakness in "Empty Can Test" and "Full Can Test" - (회전근 개 파열의 진단을 위한 극상근 검사에서 유용한 양성 징후는 무엇인가? - "Empty can test"와 full can test"에서 통증과 근력 약화의 비교 -)

  • Shin, Hun-Kyu;Kim, Eu-Gene;Jeong, Hwa-Jae;Kim, Jong-Min;Choi, Jae-Yol;Lee, Yong-Taek
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.27-32
    • /
    • 2007
  • Purpose: To investigate the validity of positive signs of supraspinatus test. Materials and Methods: The empty can test and full can test were performed on 200 shoulders which were diagnosed with magnetic resonance imaging or surgical findings as full thickness tear, partial thickness tear and no tear. Presence of pain, weakness, pain or weakness, and both pain and weakness were recorded as positive signs separately. The two tests with positive signs were compared and analyzed. Results: Pain and weakness were severity-dependent, and the empty-can test had a higher incidence of pain. The sensitivities of the two supraspinatus tests in all positive signs were higher when including partial-thickness tears in the tear group; however, their specificities were higher when excluding partial-thickness tears. The sensitivities of an empty-can test in 'pain', 'pain or weakness', 'both pain and weakness' were higher than those of the full-can test, otherwise, the specificity of the full-can test for 'pain' and 'pain or weakness' were higher. Concordance rate between 'pain or weakness' and 'pain' was the highest in all categorization. Conclusion: Both empty can and full can test were valuable for detecting torn rotator cuff.

Analysis of Ultrasonic Resonance Signal for Detecting the Defect of Adhesive Interface in Exit Cone (확대부 내열재의 접착계면 결함 검출을 위한 초음파 공진 신호 분석)

  • Kim, Dong-Ryun;Kim, Jae-Hoon;Lim, Soo-Yong;Park, Sung-Han;Yeh, Byung-Hahn
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.230-237
    • /
    • 2012
  • The ultrasonic resonance method was applied to detect the disbond interface and empty layer between steel and FRP of the exit cone. The ultrasonic resonance method can easily detect the disbond interface and empty layer by amplifying the ultrasonic signal, but pulse echo method is difficult to distinguish adhesive interface from disbond interface or empty layer. The resonance frequency was predicted using the pressure reflection coefficient of 3-layered medium, and measured from ultrasonic signal of the test block using Fast Fourier Transform. The ultrasonic resonance proved that the predicted resonance frequency was in good agreement with the measured resonance frequency.

  • PDF

The Evaluation for Running Safety of Incheon International Airport Railway EMU (인천국제공항철도 전동차의 주행안전성 평가)

  • Hong, Yong-Ki;You, Won-Hee;Lee, Hi-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.619-625
    • /
    • 2007
  • The dynamic characteristic test result of electric rail car which is operated in Incheon International Airport Railroad is described in this paper. Express train in Incheon International Airport Railroad drives at 120km/h first in the country and derailment coefficient was measured for empty car and full-loaded car respectively. The measurement result of derailment coefficient, a key safety indicator about derailment, of empty car was higher than full-loaded car and both were lower than 0.8. The railway state wasn't good in operated section where is serviced about 80eh and derailment coefficient also increased. Horizontal pressure was below 2.1 ton at empty car and below 2.4 ton at full-loaded car. The electric rail car in Incheon International Airport Railroad has been confirmed it's running safety at 120km/h by the measurement of derailment coefficient. But the way of assessing applied in this paper has demerits such as complication of test method, difficulty for measurement device installation and high cost. Therefore the method which is simple to measure and can certify vehicle's safety even when service driving has to be researched.

A Study on Acceleration Performances of EMUs According to Wheel Diameter Changes (전동차 차륜직경변화가 가속성능에 미치는 영향 연구)

  • Min, Seung Kon;Ko, Jeong Seo
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.92-99
    • /
    • 2015
  • The diameter of a new wheel in EMUs is 860mm and it can be used up to 773mm. To obtain an predefined acceleration despite wheel diameter changes, the tractive efforts of the vehicles must be properly controlled. In the commencement of this study, acceleration tests were performed for empty EMUs when the wheel diameter was changed to 860mm, 820mm and 780mm, respectively. In order to deal with more complicated running conditions, we developed dynamic simulation models of the EMUs using VI-Rail, and simulated the models in empty and full passenger loads, respectively. Using the simulation results, we analyzed the gradient of time-velocity graphs by considering the changes of the total weight vehicles and moment of inertia of the wheelsets as well as tractive effort according to the wheel diameter changes. As the results, it was found that there are significant differences in acceleration performances according to the wheel diameters and the payloads of EMUs. In case of 860mm which is the maximum wheel diameter, the test & simulation results show that the vehicle couldn't reach the predefined acceleration, 3.0km/h/s, due to lack of tractive effort.

Investigation of water length effects on the modal behavior of a prototype arch dam using operational and analytical modal analyses

  • Sevim, Baris;Bayraktar, Alemdar;Altunisik, Ahmet Can
    • Structural Engineering and Mechanics
    • /
    • v.37 no.6
    • /
    • pp.593-615
    • /
    • 2011
  • This study determines the water length effects on the modal behavior of a prototype arch dam using Operational and Analytical Modal Analyses. Achievement of this purpose involves construction of a prototype arch dam-reservoir-foundation model under laboratory conditions. In the model, reservoir length was taken to be as much as three times the dam height. To determine the experimental dynamic characteristics of the arch dam using Operational Modal Analysis, ambient vibration tests were implemented for empty reservoir and three different reservoir water lengths. In the ambient vibration tests, the dam was vibrated by natural excitations provided from small impact effects and the response signals were measured using sensitive accelerometers. Operational Modal Analysis software process signals collected from the ambient vibration tests, and Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification techniques estimated modal parameters of the dams. To validate the experimental results, 3D finite element model of the prototype arch dam was modeled by ANSYS software for empty reservoir and three different reservoir water lengths, and dynamic characteristics of each model were determined analytically. At the end of the study, experimentally and analytically identified dynamic characteristics compared to each other. Also, changes on the natural frequencies along to water length are plotted as graphs. Results suggest that reservoir water complicates the modal behavior of the arch dam significantly.

Experimental evaluation of crack effects on the dynamic characteristics of a prototype arch dam using ambient vibration tests

  • Sevim, Baris;Altunisik, Ahmet Can;Bayraktar, Alemdar
    • Computers and Concrete
    • /
    • v.10 no.3
    • /
    • pp.277-294
    • /
    • 2012
  • The aim of the study is to determine the modal parameters of a prototype damaged arch dam by operational modal analysis (OMA) method for some damage scenarios. For this purpose, a prototype arch dam-reservoir-foundation model is constructed under laboratory conditions. Ambient vibration tests on the arch dam model are performed to identify the modal parameters such as natural frequency, mode shape and damping ratio. The tests are conducted for four test-case scenarios: an undamaged dam with empty reservoir, two different damaged dams with empty reservoirs, and a damaged dam with full reservoir. Loading simulating random impact effects is applied on the dam to crack. Cracks and fractures occurred at the middle of the upper part of the dams and distributed through the abutments. Sensitivity accelerometers are placed on the dams' crests to collect signals for measurements. Operational modal analysis software processes the signals collected from the ambient vibration tests, and enhanced frequency domain decomposition and stochastic subspace identification techniques are used to estimate modal parameters of the dams. The modal parameters are obtained to establish a basis for comparison of the results of two techniques for each damage case. Results show that approximately 35-40% difference exists between the natural frequencies obtained from Case 1 and Case 4. The natural frequencies of the dam considerably decrease with increasing cracks. However, observation shows that the filled reservoir slightly affected modal parameters of the dam after severe cracking. The mode shapes obtained are symmetrical and anti-symmetrical. Apparently, mode shapes in Case 1 represent the probable responses of arch dams more accurately. Also, damping ratio show an increase when cracking increases.

The research of application plan for the twist absorption structure type brake holder hanger (비틀림 흡수구조형 제륜자 홀더행거의 적용방안에 관한 연구)

  • Hong Jai-Sung;Ham Young-Sam;Paik Young-Nam
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.903-908
    • /
    • 2004
  • Among welded structure bogies in use for high speed freight car, a part of bogies manufactured in 1999 and 2000 have found problems that crack occurs in its end beam. In case of a freight car the difference of weight between empty and loading conditions are worse than in case of a passenger car. Moreover its brake system is tread brake without second suspension system. Cracks of end beam is supposed to be due to loading by brake system rather than vertical loading by freight. These cracks can make brake system useless and may be a cause of derailment in the worst case. In this study, we have proposed a simple torsion-free brake shoe holder hanger to remove torsion of hanger bracket which was supposed to be one of causes of cracks and performed finite element analyses. Also static load test was applied in torsion free brake shoe holder.

  • PDF

An efficient method of spatial cues and compensation method of spectrums on multichannel spatial audio coding (멀티채널 Spatial Audio Coding에서의 효율적인 Spatial Cues 사용과 그에 따른 Spectrum 보상방법)

  • Lee, Byong-Hwa;Beack, Seung-Kwon;Seo, Jeong-Gil;Han, Min-Soo
    • MALSORI
    • /
    • no.53
    • /
    • pp.157-169
    • /
    • 2005
  • This paper proposes an efficiently representing method of spatial cues on multichannel spatial audio coding. The Binaural Cue Coding (BCC) method introduced recently represents multichannel audio signals by means of Inter Channel Level Difference (ICLD) or Source Index (SI). We tried to express more efficiently ICLD and SI information based on Inter Channel Correlation in this paper. We adopt different spatial cues according to ICC and propose a compensation method of empty spectrums created by using SI. We performed a MOS test and measuring spectral distortion. The results show that the proposed method can reduce the bitrate of side information without large degradation of the audio quality.

  • PDF