• Title/Summary/Keyword: Empirical correlation

Search Result 1,235, Processing Time 0.029 seconds

Modeling for Frost Growth on a Cold Plate (냉각 평판에서 서리 성장 모델링)

  • Yang, Dong-Keun;Lee, Kwan-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1546-1551
    • /
    • 2004
  • This paper presents a mathematical model to predict the frost properties and heal and mass transfer within the frost layer formed on a cold plate. The laminar flow equations for the air-side are analyzed. and the empirical correlations of local frost properties are employed in order to predict the frost layer growth. The correlations of local frost density and effective thermal conductivity of frost layer, obtained from various experimental conditions, are derived as functions of various frosting parameters (Reynolds number, frost surface temperature, absolute humidity and temperature of moist air, cooling plate temperature, and frost density). The numerical results are compared with experimental data and the results of various models to validate the present model, and agree well with experimental data within a maximum error of 10%. The heat and mass transfer coefficients obtained from the numerical analyses are presented, as the results, it is found that the model for frost growth using the correlation of heat transfer coefficient without solving air flow have a limitation in its application.

  • PDF

Correlation analysis between climate indices and Korean precipitation and temperature using empirical mode decomposition : II. Correlation analysis (경험적 모드분해법을 이용한 기상인자와 우리나라 강수 및 기온의 상관관계 분석 : II. 상관관계 분석)

  • Ahn, Si-Kweon;Choi, Wonyoung;Shin, Hongjoon;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.3
    • /
    • pp.207-215
    • /
    • 2016
  • In this study, it is analyzed how large scale climate variation has an effect on climate systems over Korea using correlation analysis between climate indices and Intrinsic Mode Functions (IMFs) of precipitation and temperature. For this purpose, the estimated IMFs of precipitation and temperature from the accompanying paper were used. Furthermore, cross correlation coefficients and lag time between climate indices and IMFs were calculated considering periodicities and tendencies. As results, more accurate correlation coefficients were obtained compared with those between climate indices and raw precipitation and temperature data. We found that the Korean climate is closely related with climate variations of $El-Ni{\tilde{n}}o$ in terms of periodicity and its tendency is followed with increasing sea surface temperature due to climate change.

An Empirical Study for University Educational Service Satisfaction Factors

  • Choi, Kyung-Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.2
    • /
    • pp.279-289
    • /
    • 2006
  • This paper concerns with the effects of the specialized projected for the local W university on education which was planned and conducted in October 2004. From the empirical study using the correlation analysis, regression analysis, and structured equation model, we found some results that educational service satisfaction was highly correlated with general instruction factor and hard ware factor less correlated. Also we investigated that university educational service satisfaction was deeply correlated with word of mouth.

  • PDF

Comparison of the Numerical, Theoretical, and Empirical Scattering Models for Randomly Rough Surfaces

  • Hong Jin-Young;Oh Yisok
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.725-728
    • /
    • 2005
  • The scattering problem of the randomly rough surface is examined by the method of moments(MoM), small perturbation method (SPM), integral equation method (IEM) and the semi-empirical polarimetic model. To apply the numerical technique of the MoM to microwave scattering from a rough surface, at first, many independent randomly rough surfaces with a rms height and a correlation length are generated with Gaussian random deviate. Then, an efficient Monte Carlo simulation technique is applied to estimate the scattering coefficients of the surfaces.

  • PDF

A Empirical Study on the Developments of Pay Satisfaction Measurements (임금만족 측정치 개발에 관한 실증적 연구)

  • 이광희
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.54
    • /
    • pp.119-128
    • /
    • 2000
  • This study develops the pay satisfaction questionnaire for Korean employees. Based upon the review of previous studies, 16 questionnaire items are developed. Exploratory factor analysis results in a modified measurement through item deletion, item-to-dimension reassignment, and dimension combination. The measurement model was good fit assessed by overall fit measures(GFI; goodness of fit index, AGFI; adjusted goodness of fit index, RMR; root mean square residual) criteria, lambda score, and squared multiple correlation with confirmatory factor analysis. Implication of this work for future theoretical and empirical development are suggested.

  • PDF

An Empirical Correlation for Subcooled Two-Phase Critical Flow Rates in Short Tubes, Nozzles, and Orifices

  • Park, Choon-Kyung;Seok Cho;Won, Soon-Yeun;Min, Kyung-Ho;Chung, Moon-Ki
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.273-278
    • /
    • 1997
  • Critical two-phase flow rates of subcooled water through very short tube (L=20 mm) with small diameters (D=1.0 mm) has been measured for wide ranges of subcooling(0~186$^{\circ}C$) and pressure (0.5~2.0 MPa). Experimental results show that subcooled critical two-phase flow rates can be expressed in terms of two scaling parameters for geometries and initial conditions. They are discharge coefficient of cold water, ( $C_{d}$ )$_{ref}$, and dimensionless subcooling, $\Delta$ $T^{*}$$_{sub}$, respectively. A new empirical correlation expressed in terms of ( $C_{d}$ )$_{ref}$ and $\Delta$ $T^{*}$$_{sub}$ is obtained for subcooled two-phase flow rates through very short length tube. Comparisons between the mass fluxes calculated by Present correlation and a number of experimental data show that the agreement is very good.ood.ood.ood.

  • PDF

Air-Water Countercurrent Flow Limitation in a Horizontal Pipe Connected to an Inclined Riser

  • Kang, Seong-Kwon;Chu, In-Cheol;No, Hee-Cheon;Chun, Moon-Hyun;Sung, Chang-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.548-560
    • /
    • 1999
  • An experimental investigation has been peformed to examine the effects of various geometrical parameters and an initial operating condition on the air-water countercurrent How limitation (CCFL) in a simulated PWR hot leg. A total of 118 experimental data for the onset of CCFL and zero liquid penetration were obtained for various combinations of test parameters. It was observe that the CCFL can be classified into three different categories: (the onset of CCFL, (the partial liquid delivery, and (r) the zero liquid penetration. The observed mechanisms of the onset of CCFL were different depending on the inlet water flow rate. The parametric effects of pipe diameter, horizontal pipe length, horizontal pipe length-to-diameter (L/D) ratio, and initial water level in the horizontal pipe of the test section on the onset of air-water CCFL were also examined. An empirical correlation for the onset of CCFL in a horizontal pipe connected to an inclined riser was developed in terms of Wallis flooding parameters for the low inlet water flow rate region. Comparisons of the present empirical correlation with the air-water CCFL data of large pipe diameters show that the present correlation agrees more closely with the experimental data than the existing CCFL correlations.

  • PDF

Frost Formation on a Cylinder under Heat Pump Condition (히트펌프 조건의 원형관에서의 착상에 관한 연구)

  • Yoon, Shin-Hyuk;Cho, Keum-Nam;Hayase, Gaku
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.804-809
    • /
    • 2009
  • The present study measured frost pattern on a cylinder to propose empirical correlation equations for the local and average frost thickness, frost density and frost mass. The key parameters were diameter of the cylinders (7mm, 20mm), cooling surface temperature of the circular tube, absolute humidity of air, air temperature and air velocity. A 50% ethylene glycol aqueous solution was applied as a coolant. The frost thicknesses at both front and rear were larger than those at the other parts, while they were increased as diameter of the cylinder was increased. The local frost thicknesses at high air velocity were more uniform than those at low air velocity. The values predicted by Kim et al. under the freezer condition showed larger by the maximum of $30{\sim}50%$ than the measured data under heat pump condition. The empirical correlations for the local and average frost thickness and frost mass were proposed. The correlation equations for the frost thickness and frost mass under the heat pump condition in the present study might predict more accurate than the other correlation equations. The proposed correlations might be applied for the freezer condition within the maximum 15% deviation from the previous correlations under freezer condition.

  • PDF

Unrelated Question Model in Sensitive Multi-Character Surveys

  • Sidhu, Sukhjinder Singh;Bansal, Mohan Lal;Kim, Jong-Min;Singh, Sarjinder
    • Communications for Statistical Applications and Methods
    • /
    • v.16 no.1
    • /
    • pp.169-183
    • /
    • 2009
  • The simplicity and wide application of Greenberg et al. (1971) prompts to propose a set of alternative estimators of population total for multi-character surveys that elicit simultaneous information on many. sensitive study variables. The proposed estimators take into account the already known rough value of the correlation coefficient between Y(the characteristic under study) and p(the measure of size). These estimators are biased, but it is expected that the extent of bias will be smaller, since the proposed estimators are suitable for situations in between those optimum for the usual estimators and the estimators based on multi-characters for no correlation. The relative efficiency of the proposed estimators has been studied under a super population model through empirical study. It has been found through simulation study that a choice of an unrelated variable in the Greenberg et al. (1971) model could be made based on its correlation with the auxiliary variable used at estimation stage in multi-character surveys.

An Empirical Correlation for Critical Flow Rates of Subcooled Water Through Short Pipes with Small Diameters

  • Park, Choon-Kyung;Park, Jee-Won;Chung, Moon-Ki;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.35-44
    • /
    • 1997
  • Critical too-Phase flow rates of subcooled water through Short Pipes (L 140039n) with small diameters (D$\leq$7.15 min) have been experimentally investigated for wide ranges of subcooling (0~199$^{\circ}C$) and pressure (0.5~2.0 MPa). To examine the effects of various parameters (i.e., the location of flashing inception, the degree of subcooling, the stagnation temperature and pressure, and the pipe size) on the critical two-phase flow rates of subcooled water through short pipes with small diameters, a total of 135 runs were made for various combinations of test parameters using four different L/D test sections. Experimental results that show effect of various parameters on subcooled critical two phase flow rates are presented in the form of graphs such as the dimensionless mass flux ( $G^{*}$) versus the dimensionless subcooling ( $T_{sub}$$^{*}$) curve. An empirical correlation expressed in terms of a dimensionless subcooling is also obtained for subcooled two-phase flow rates through present test sections. Comparisons between the mass fluxes calculated by present correlation and a total of 755 selected experimental data points of 9 different investigators show that the agreement is fairly good except for very low subcooling data obtained from small L/D (less than 10) orifices.s.s.s.

  • PDF