• 제목/요약/키워드: Empirical Correlation

검색결과 1,227건 처리시간 0.031초

냉각 평판에서 서리 성장 모델링 (Modeling for Frost Growth on a Cold Plate)

  • 양동근;이관수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1546-1551
    • /
    • 2004
  • This paper presents a mathematical model to predict the frost properties and heal and mass transfer within the frost layer formed on a cold plate. The laminar flow equations for the air-side are analyzed. and the empirical correlations of local frost properties are employed in order to predict the frost layer growth. The correlations of local frost density and effective thermal conductivity of frost layer, obtained from various experimental conditions, are derived as functions of various frosting parameters (Reynolds number, frost surface temperature, absolute humidity and temperature of moist air, cooling plate temperature, and frost density). The numerical results are compared with experimental data and the results of various models to validate the present model, and agree well with experimental data within a maximum error of 10%. The heat and mass transfer coefficients obtained from the numerical analyses are presented, as the results, it is found that the model for frost growth using the correlation of heat transfer coefficient without solving air flow have a limitation in its application.

  • PDF

경험적 모드분해법을 이용한 기상인자와 우리나라 강수 및 기온의 상관관계 분석 : II. 상관관계 분석 (Correlation analysis between climate indices and Korean precipitation and temperature using empirical mode decomposition : II. Correlation analysis)

  • 안시권;최원영;신홍준;허준행
    • 한국수자원학회논문집
    • /
    • 제49권3호
    • /
    • pp.207-215
    • /
    • 2016
  • 본 연구에서는 우리나라 강수 및 기온과 다양한 기상인자와의 교차상관관계 분석을 통해 대규모 기후변동이 우리나라에 어떠한 영향을 주는지를 분석하였다. 강수 및 기온자료의 경우 앞선 연구인 "경험적 모드분해법을 이용한 기상인자와 우리나라 강수 및 기온의 상관관계 분석 : I. 자료의 분해 및 특성분석"의 연구결과를 통해 주기성, 경향성에 따라 분해한 강수 및 기온자료의 내재모드함수를 사용하여, 자료의 변동이 심하고 잡음이 포함된 원 자료를 통한 상관관계 분석보다 좀 더 명확한 상관계수를 계산하였다. 이렇게 분해된 기상자료와 기상인자간의 교차상관관계 분석을 통해 그 시간차와 상관계수를 계산하여, 주기성과 경향성 측면에서 어떠한 상관관계가 있는지를 분석하였다. 그 결과 주기성 측면에서 엘니뇨현상에 의한 기후변동이 우리나라 기상현상과 밀접한 관련이 있으며, 경향성 측면에서 기후변화로 인한 해수면 온도 증가추세가 우리나라 기상현상과 밀접한 연관이 있음을 알 수 있었다.

An Empirical Study for University Educational Service Satisfaction Factors

  • Choi, Kyung-Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • 제17권2호
    • /
    • pp.279-289
    • /
    • 2006
  • This paper concerns with the effects of the specialized projected for the local W university on education which was planned and conducted in October 2004. From the empirical study using the correlation analysis, regression analysis, and structured equation model, we found some results that educational service satisfaction was highly correlated with general instruction factor and hard ware factor less correlated. Also we investigated that university educational service satisfaction was deeply correlated with word of mouth.

  • PDF

Comparison of the Numerical, Theoretical, and Empirical Scattering Models for Randomly Rough Surfaces

  • Hong Jin-Young;Oh Yisok
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.725-728
    • /
    • 2005
  • The scattering problem of the randomly rough surface is examined by the method of moments(MoM), small perturbation method (SPM), integral equation method (IEM) and the semi-empirical polarimetic model. To apply the numerical technique of the MoM to microwave scattering from a rough surface, at first, many independent randomly rough surfaces with a rms height and a correlation length are generated with Gaussian random deviate. Then, an efficient Monte Carlo simulation technique is applied to estimate the scattering coefficients of the surfaces.

  • PDF

임금만족 측정치 개발에 관한 실증적 연구 (A Empirical Study on the Developments of Pay Satisfaction Measurements)

  • 이광희
    • 산업경영시스템학회지
    • /
    • 제23권54호
    • /
    • pp.119-128
    • /
    • 2000
  • This study develops the pay satisfaction questionnaire for Korean employees. Based upon the review of previous studies, 16 questionnaire items are developed. Exploratory factor analysis results in a modified measurement through item deletion, item-to-dimension reassignment, and dimension combination. The measurement model was good fit assessed by overall fit measures(GFI; goodness of fit index, AGFI; adjusted goodness of fit index, RMR; root mean square residual) criteria, lambda score, and squared multiple correlation with confirmatory factor analysis. Implication of this work for future theoretical and empirical development are suggested.

  • PDF

An Empirical Correlation for Subcooled Two-Phase Critical Flow Rates in Short Tubes, Nozzles, and Orifices

  • Park, Choon-Kyung;Seok Cho;Won, Soon-Yeun;Min, Kyung-Ho;Chung, Moon-Ki
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.273-278
    • /
    • 1997
  • Critical two-phase flow rates of subcooled water through very short tube (L=20 mm) with small diameters (D=1.0 mm) has been measured for wide ranges of subcooling(0~186$^{\circ}C$) and pressure (0.5~2.0 MPa). Experimental results show that subcooled critical two-phase flow rates can be expressed in terms of two scaling parameters for geometries and initial conditions. They are discharge coefficient of cold water, ( $C_{d}$ )$_{ref}$, and dimensionless subcooling, $\Delta$ $T^{*}$$_{sub}$, respectively. A new empirical correlation expressed in terms of ( $C_{d}$ )$_{ref}$ and $\Delta$ $T^{*}$$_{sub}$ is obtained for subcooled two-phase flow rates through very short length tube. Comparisons between the mass fluxes calculated by Present correlation and a number of experimental data show that the agreement is very good.ood.ood.ood.

  • PDF

Air-Water Countercurrent Flow Limitation in a Horizontal Pipe Connected to an Inclined Riser

  • Kang, Seong-Kwon;Chu, In-Cheol;No, Hee-Cheon;Chun, Moon-Hyun;Sung, Chang-Kyung
    • Nuclear Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.548-560
    • /
    • 1999
  • An experimental investigation has been peformed to examine the effects of various geometrical parameters and an initial operating condition on the air-water countercurrent How limitation (CCFL) in a simulated PWR hot leg. A total of 118 experimental data for the onset of CCFL and zero liquid penetration were obtained for various combinations of test parameters. It was observe that the CCFL can be classified into three different categories: (the onset of CCFL, (the partial liquid delivery, and (r) the zero liquid penetration. The observed mechanisms of the onset of CCFL were different depending on the inlet water flow rate. The parametric effects of pipe diameter, horizontal pipe length, horizontal pipe length-to-diameter (L/D) ratio, and initial water level in the horizontal pipe of the test section on the onset of air-water CCFL were also examined. An empirical correlation for the onset of CCFL in a horizontal pipe connected to an inclined riser was developed in terms of Wallis flooding parameters for the low inlet water flow rate region. Comparisons of the present empirical correlation with the air-water CCFL data of large pipe diameters show that the present correlation agrees more closely with the experimental data than the existing CCFL correlations.

  • PDF

히트펌프 조건의 원형관에서의 착상에 관한 연구 (Frost Formation on a Cylinder under Heat Pump Condition)

  • 윤신혁;조금남;하야세가쿠
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.804-809
    • /
    • 2009
  • The present study measured frost pattern on a cylinder to propose empirical correlation equations for the local and average frost thickness, frost density and frost mass. The key parameters were diameter of the cylinders (7mm, 20mm), cooling surface temperature of the circular tube, absolute humidity of air, air temperature and air velocity. A 50% ethylene glycol aqueous solution was applied as a coolant. The frost thicknesses at both front and rear were larger than those at the other parts, while they were increased as diameter of the cylinder was increased. The local frost thicknesses at high air velocity were more uniform than those at low air velocity. The values predicted by Kim et al. under the freezer condition showed larger by the maximum of $30{\sim}50%$ than the measured data under heat pump condition. The empirical correlations for the local and average frost thickness and frost mass were proposed. The correlation equations for the frost thickness and frost mass under the heat pump condition in the present study might predict more accurate than the other correlation equations. The proposed correlations might be applied for the freezer condition within the maximum 15% deviation from the previous correlations under freezer condition.

  • PDF

Unrelated Question Model in Sensitive Multi-Character Surveys

  • Sidhu, Sukhjinder Singh;Bansal, Mohan Lal;Kim, Jong-Min;Singh, Sarjinder
    • Communications for Statistical Applications and Methods
    • /
    • 제16권1호
    • /
    • pp.169-183
    • /
    • 2009
  • The simplicity and wide application of Greenberg et al. (1971) prompts to propose a set of alternative estimators of population total for multi-character surveys that elicit simultaneous information on many. sensitive study variables. The proposed estimators take into account the already known rough value of the correlation coefficient between Y(the characteristic under study) and p(the measure of size). These estimators are biased, but it is expected that the extent of bias will be smaller, since the proposed estimators are suitable for situations in between those optimum for the usual estimators and the estimators based on multi-characters for no correlation. The relative efficiency of the proposed estimators has been studied under a super population model through empirical study. It has been found through simulation study that a choice of an unrelated variable in the Greenberg et al. (1971) model could be made based on its correlation with the auxiliary variable used at estimation stage in multi-character surveys.

An Empirical Correlation for Critical Flow Rates of Subcooled Water Through Short Pipes with Small Diameters

  • Park, Choon-Kyung;Park, Jee-Won;Chung, Moon-Ki;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.35-44
    • /
    • 1997
  • Critical too-Phase flow rates of subcooled water through Short Pipes (L 140039n) with small diameters (D$\leq$7.15 min) have been experimentally investigated for wide ranges of subcooling (0~199$^{\circ}C$) and pressure (0.5~2.0 MPa). To examine the effects of various parameters (i.e., the location of flashing inception, the degree of subcooling, the stagnation temperature and pressure, and the pipe size) on the critical two-phase flow rates of subcooled water through short pipes with small diameters, a total of 135 runs were made for various combinations of test parameters using four different L/D test sections. Experimental results that show effect of various parameters on subcooled critical two phase flow rates are presented in the form of graphs such as the dimensionless mass flux ( $G^{*}$) versus the dimensionless subcooling ( $T_{sub}$$^{*}$) curve. An empirical correlation expressed in terms of a dimensionless subcooling is also obtained for subcooled two-phase flow rates through present test sections. Comparisons between the mass fluxes calculated by present correlation and a total of 755 selected experimental data points of 9 different investigators show that the agreement is fairly good except for very low subcooling data obtained from small L/D (less than 10) orifices.s.s.s.

  • PDF