• Title/Summary/Keyword: Emission Path

Search Result 107, Processing Time 0.026 seconds

Comparison of CH4 Emission by Open-path and Closed Chamber Methods in the Paddy Rice Fields (벼논에서 open-path와 closed chamber 방법 간 메탄 배출량 비교)

  • Jeong, Hyun-cheol;Choi, Eun-jung;Kim, Gun-yeob;Lee, Sun-il;Lee, Jong-sik
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.4
    • /
    • pp.507-516
    • /
    • 2018
  • The closed chamber method, which is one of the most commonly used method for measuring greenhouse gases produced in rice paddy fields, has limitations in measuring dynamic $CH_4$ flux with spatio-temporal constrains. In order to deal with the limitation of the closed chamber method, some studies based on open-path of eddy covariance method have been actively conducted recently. The aim of this study was to compare the $CH_4$ fluxes measured by open-path and closed chamber method in the paddy rice fields. The open-path, one of the gas ($CO_2$, $CH_4$ etc.) analysis methods, is technology where a laser beam is emitted from the source passes through the open cell, reflecting multiple times from the two mirrors, and then detecting. The $CH_4$ emission patterns by these two methods during rice cultivation season were similar, but the total $CH_4$ emission measured by open-path method were 31% less than of the amount measured by closed chamber. The reason for the difference in $CH_4$ emission was due to overestimation by closed chamber and underestimation by open-path. The closed chamber method can overestimate $CH_4$ emissions due to environmental changes caused by high temperature and light interruption by acrylic partition in chamber. On the other hand, the open-path method for eddy covariance can underestimate its emission because it assumes density fluctuations and horizontal homogeneous terrain negligible However, comparing $CH_4$ fluxes at the same sampling time (AM 10:30-11:00, 30-min fluxes) showed good agreements ($r^2=0.9064$). The open-path measurement technique is expected to be a good way to compensate for the disadvantage of the closed chamber method because it can monitor dynamic $CH_4$ fluctuation even if data loss is taken into account.

Analysis of Emission Characteristics of DC/DC Converter with different Parts Layout (부품배치가 다르게 제작된 DC/DC컨버터의 Emission 특성분석)

  • Park, Jin-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.179-183
    • /
    • 2019
  • The system stability must be ensured from the switching noise due to the power conversion efficiency and power conversion system miniaturization. Therefore, countermeasures to reduce switching noise during power conversion are essential. Thus, in the previous paper, we constructed the DC / DC Buck Converter circuit using MPQ4432 driver of MPS, and simulated the switching noise characteristics which occurs when the components are arranged differently in the 4 - layer PCB circuit structure with reference plane. In this paper, two different simulated circuits are fabricated and the characteristics of the conducted emission and the radiated emission are analyzed in the same way as the simulation. As a result, it was confirmed that the Conducted Emission characteristic was reduced by 2 ~ 9dB in the low frequency band and 6 ~ 7dB in the high frequency band depending on the configuration of the current return path. And the radiated emission characteristic is reduced by 9 dB. Conducted emission simulation results show that 6 ~ 7dB in the low frequency range and 2 ~ 9dB in the measurement result are somewhat different. In the high frequency band, it is confirmed that the experimental and simulation results are about 7dB. And Radiated Emission confirmed 12dB decrease in simulation, but confirmed decrease of 9dB in measurement result. It is confirmed that there is a slight difference in the amount of reduction, but the design of the power conversion circuit improves the noise characteristics according to the configuration of the current return path.

Unambiguous Identification of Fugitive Pollutants and Determination of Annual Emission Flux as Diurnal Monitoring Mode

  • Chang, Shih-Yi;Tso, Tai-Ly;Lo, Jiunn-Gung;Huang, Jer-Luen;Lin, Cheng Ming
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.731-738
    • /
    • 1995
  • Toxic air pollutants are investigated in a petrochemical industrial park in Taiwan by using a movable open path FTIR. The results show the qualitative and quantitative analysis of emission gases from plants, and also provide the emission rate of different compounds. More than twenty compounds under usual operation are found from this industrial park. The concentration variation with time can be correlated exactly with wind direction. It means that by changing the measuring points, the source of emission can be unambiguously identified. An EPA proved PAL model is applied to estimate the emission rate of either a point or an area source. Local atmospheric stability is determined by releasing the $SF_6$ tracer. The origins of errors come mainly from the uncertainty of source's configuration and the variation of meteorological condition. Through the continuous measurement (half an hour base in this study) of OP-FTIR sensor, the maximum value of emission rate and the annual amount of emission can be derived. The emission rate of the measured toxic gases are derived by the model technique and the results show that the emission amount are in the order of ten to hundred tons per year.

  • PDF

Analysis of Emission Characteristics of DC/DC Converter by Component Placement (부품배치에 따른 DC/DC 컨버터의 Emission 특성분석)

  • Park, Jin-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.639-643
    • /
    • 2018
  • As electronic systems become smaller and more portable, the need for power conversion continues to increase. In addition, system stability must be ensured from switching noise due to power conversion efficiency and power conversion system miniaturization. Therefore, countermeasures to reduce switching noise during power conversion are essential. In this paper, a DC/DC buck converter circuit is constructed, and the characteristics of switching noise generated when changing the parts layout in a four-layer printed circuit board (PCB) structure with a reference plane are compared and analyzed. In addition, switching noise characteristics were compared and analyzed through simulations when the parts layout was different in a two-layer PCB structure from which the reference planes were removed. As a result, it was confirmed that the radiated emissions characteristic is reduced by 12dB and the conducted emissions characteristic decreased by 7dB to 8dB, according to the current return path in the four-layer PCB structure. Thus, it was confirmed that the noise characteristics can be improved according to the configuration of the current return path when the power conversion circuit is designed.

Analysis of surface emission and oxidation rate of landfill gas by major discharge path of landfill (매립장 주요 배출경로별 매립가스 표면발산량 및 산화율 분석)

  • Seung-Kyu Chun;Jong-Keun Park;Myoung-Gwan Kim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.3
    • /
    • pp.425-434
    • /
    • 2023
  • An analysis was conducted on landfill gas generation and surface emission by major routes for three landfill sites of S Landfill in the metropolitan area. LS1, which had a total landfill gas generation ratio of 10.9%, accounted for 49.4% of the total surface emissions. The total surface emission of methane alone was 13.6 Nm3/min in the three landfill sites. Among them, the surface emission of methane at LS1, LS2, and LS3 was 8.4(61.7%), 4.0(29.4%), and 1.2 Nm3/min(8.9%), respectively. By emission path in the upper, slope, and dike, it was 7.3(53.2%), 6.4(46.7%), and 0.02 Nm3/min(0.1%). The dike section of the major surface emission areas showed the largest oxidation rate at 87.5%, followed by the upper at 72.3%, and the slope at 71.8%. Based on methane generation, LS1 had the largest surface emission contribution rate, with 61.7% of the total by S Landfill. By major emission path, the slope section of LS1 accounted for 41.7% of the total, the upper section of LS2 24.4%, and the upper section of LS1 20.0%, which accounted for 86.1% of the total methane surface emission of S Landfill. Therefore, it is concluded that intensive management will be necessary.

Microcavity Effect of Top-emission Organic Light-emitting Diodes Using Aluminum Cathode and Anode

  • Lee, Chang-Jun;Park, Young-Il;Kwon, Jang-Hyuk;Park, Jong-Wook
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.9
    • /
    • pp.1344-1346
    • /
    • 2005
  • We report microcavity effect of top emission organic light-emitting diodes (OLEDs) by using Al cathode and anode, which are feasible for not only top emission EL and angle dependant effects but facile evaporation process without ion sputtering. The device in case of $Alq_3$ green emission showed largely shifted EL maximum wavelength as 650 nm maximum emission. It was also observed that detection angle causes different EL maximum wavelength and different CIE values in R, G, B color emission. As a result, the green device using $Alq_3$ emission showed 650 nm emission ($0^{\circ}$) to 576 nm emission ($90^{\circ}$) as detection angle changed. We believe that these phenomena can be also explained with microcavity effect which depends on the different length of light path caused by detection angle.

Thickness and Angle Dependent Microcavity Properties in Top-Emission Organic Light-Emitting Diodes (상부 발광 유기 발광 소자에서 두께와 시야각에 따른 마이크로 캐비티 특성)

  • Lee, Won-Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.32-35
    • /
    • 2011
  • Top-emission device has a merit of high aperture ratio and narrow emission spectrum compared to that of bottom-emission one. Emission spectra of top-emission organic light-emitting diodes depending on a layer thickness and view angle were analyzed using a theory of microcavity. Device structure was manufactured to be Al (100 nm)/TPD/$Alq_3$/LiF (0.5 nm)/Al (2 nm)/Ag (30 nm). N,N'-diphenyl-N,N'- di (m-tolyl)-benzidine (TPD) and tris (8-hydroxyquinoline) aluminium (Alq3) were used as a hole-transport layer and emission layer, respectively. And a thickness of TPD and Alq3 layer was varied in a range of 40 nm~70 nm and 60 nm~110 nm, respectively. Angle-dependent emission spectrum out of the device was measured with a device fixed on a rotating plate. Since the top-emission device has a property of microcavity, it was observed that the emission spectrum shift to a longer wavelength region as the organic layer thickness increases, and to a shorter wavelength region as the view angle increases. Layer thickness and view-angle dependent emission spectra of the device were analyzed in terms of microcavity theory. A reflectivity of semitransparent cathode and optical path length were deduced.

Soot Temperature and Concentration Measurement Using Emission/Transmission Tomography in Laminar Diffusion Flame (방사와 투과를 이용한 층류확산화염내 매연입자의 온도 및 농도 측정)

  • 송상종;박성호;김상수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.10
    • /
    • pp.2563-2573
    • /
    • 1993
  • The measurements of monochromatic line-of-sight flame emission and light transmission in the same path having small spatial resolution were performed in an axisymmetric laminar propane $C_{3}H_{8}$ diffusion flame. The light wavelengthes of 632 nm, 800nm, 900nm were used. From these measurements, local point soot radiances (by Kirchhoff's law) and absorption coefficients were reconstructed by tomography. Thus local point soot temperatures and concentrations were obtained. The reconstructed soot temperatures and concentrations of local points have no differences between the case of visible range (632 nm) and the case of infrared range (800 nm and 900 nm). In these ranges, the scattering coefficient is much lower than the absorption coefficient. Soot mean temperature over the path also matches well with local soot temperature in outer region of the flame. Temperature measurement by thermocouple with different bead diameters $(222{\mu}m and 308{\mu}m)$ was carried in the same flame. Rapid insertion technique was used and radiation effect was considered. Radiation correction in the sooting region was carried out and the corrected result was in good agreement with the local soot temperature.

On-Line Monitoring of Microscopic Fracture Behavior of Concrete Using Acoustic Emission (음향방출을 이용한 콘크리트 부재의 미시적 파괴특성의 On-Line Monitoring)

  • 이준현;이진경;장일영;윤동진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.677-682
    • /
    • 1998
  • Concrete is an inhomogeneous material consisting of larger aggregates and sand embedded in a cement paste matrix. In this study, an acoustic emission technique has been used to clarify the microscope failure mechanisms of concrete under three point bending test. AE source location has also been done to monitor the activities of internal damage and the progress of microscopic failure path during the loading. The relationship between AE characteristic and microscopic and microscopic failure mechanism is discussed.

  • PDF

Non-destructive Leakage Location Analysis Method in Substrate Behavior Response Testing of Waterproofing Membrane Systems using Thermal Emission Camera

  • Oh, Kyu-Hwan;Jiang, Bo;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.47-48
    • /
    • 2017
  • The substrate behavior response testing outlined in KS F 2622 evaluates the leakage cause of waterproofing membrane systems when subjected to the concrete joint load behaviors by removing the waterproofing layer after testing, relying mostly on visual observation and subjective analysis. A non-destructive leakage cause and failure type analysis method is proposed currently in this study by the means of detecting leakage paths using thermal emission imaging systems. Test specimens are placed in varying temperature conditions after the concrete joint movement testing and are scanned using the thermal emission camera to determine the location and dimension of the adhesion failure/leakage path beneath the waterproofing membranes.

  • PDF