• Title/Summary/Keyword: Emergency water

Search Result 442, Processing Time 0.027 seconds

A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography (C-arm CT의 필수 성능평가 기준 마련을 위한 연구)

  • Kim, Eun-Hye;Park, Hye-Min;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

A Review of Urban Flooding: Causes, Impacts, and Mitigation Strategies (도시 홍수: 원인, 영향 및 저감 전략 고찰)

  • Jin-Yong Lee
    • The Journal of Engineering Geology
    • /
    • v.33 no.3
    • /
    • pp.489-502
    • /
    • 2023
  • Urban floods pose significant challenges to cities worldwide, driven by the interplay between urbanization and climate change. This review examines recent studies of urban floods to understand their causes, impacts, and potential mitigation strategies. Urbanization, with its increase in impermeable surfaces and altered drainage patterns, disrupts natural water flow, exacerbating surface runoff during intense rainfall events. The impacts of urban floods are far-reaching, affecting lives, infrastructure, the economy, and the environment. Loss of life, property damage, disruptions to critical services, and environmental consequences underscore the urgency of effective urban flood management. To mitigate urban floods, integrated flood management strategies are crucial. Sustainable urban planning, green infrastructure, and improved drainage systems play pivotal roles in reducing flood vulnerabilities. Early warning systems, emergency response planning, and community engagement are essential components of flood preparedness and resilience. Looking to the future, climate change projections indicate increased flood risks, necessitating resilience and adaptation measures. Advances in research, data collection, and modeling techniques will enable more accurate flood predictions, thus guiding decision-making. In conclusion, urban flooding demands urgent attention and comprehensive strategies to protect lives, infrastructure, and the economy.

Application of a Synbio-Glucan Functional Spray for Canine Atopic Dermatitis

  • Yoon-Hwan Kim;Yunho Jeong;Ju-Hyun An;Jin-Ok Ahn;Jin-Young Chung
    • Journal of Veterinary Clinics
    • /
    • v.40 no.1
    • /
    • pp.8-15
    • /
    • 2023
  • Atopic dermatitis (AD) is a common skin disease in animals and several therapeutic trials with various drugs have been conducted for more effective management of AD. However, these trials have not been able to properly address all the aspects of AD management because of the lack of good efficacy or due to significant side effects of the drugs being tested. Synbio-glucan functional spray is a functional skin spray using Synbio-glucan composed of β-glucan and probiotics. We designed a functional spray composed of Synbio-glucan (patent application number:10-1805863), distilled water, glycerin, solubilizer, and 40% alcohol. We tested the efficacy and safety of the functional spray on six dogs with AD. The trial was conducted with the consent of the caregivers. The spray was applied to the skin lesions, including the trunk, axillae, inguinal region, or periocular areas, thrice a day for 30 days. To evaluate the efficacy of this functional spray, we assessed the pruritus visual analog scale (PVAS) and the canine atopic dermatitis extent and severity index (CADESI)-4. At the end of one month, the results clinical scores after functional spray treatment showed a significant decrease in the PVAS (p = 0.03) and CADESI-4 (p = 0.03) in all the subject dogs with AD. This study thus confirmed that the Synbio-glucan functional spray is efficacious and safe for the treatment of AD in dogs.

Analysis of Electrical Resistivity Change in Piping Simulation of a Fill Dam (필댐의 파이핑 재현시험시 전기비저항 변화 분석)

  • Ahn, Hee-Bok;Lim, Heui-Dae
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.4
    • /
    • pp.59-68
    • /
    • 2010
  • Piping, a common form of internal embankment erosion, is caused by progressive movement of soil particles through an embankment. The phenomenon commonly occurs with precursory signs of development of fractures in dam structures, but also occurs without any noticeable signs in dams that showed satisfactory dam performance for several years, due to dissolution of soluble material in an embankment. While piping accounts for nearly 50% of the causes for dam failure, few studies have been made for systematic evaluation of the phenomenon. In this study, we attempted to monitor the changes in electrical resistivities of fill-dam material while a saddle dam is dismantled for the construction of emergency spillways of Daechung dam. Two artificial subhorizontal boreholes were drilled into the embankment structure to simulate piping along the two artificial flow channels. Monitoring of changes in electrical resistivity showed an increase in resistivity values during piping. Thus, the investigation of resistivity over time could be an effective method for piping prediction.

A Survey of Medical Environments in Regional Public Hospitals Respond to Disasters (지역거점공공병원의 재난 대비 안전한 의료환경 실태조사 연구)

  • Lee, Hyunjin;Song, Sanghoon;Kim, Taeyun;Kim, Youngaee
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.2
    • /
    • pp.35-46
    • /
    • 2024
  • Purpose: It is the responsibility of public healthcare to respond quickly to infectious disease outbreaks and disasters such as MERS, COVID-19, the Syrian earthquake, and the Miryang Sejong Hospital fire accident. It is very important to secure safe medical facilities and protect lives through emergency medical support and disaster response systems. The purpose of this study is to investigate the safety status of regional medical facilities that play a central role in the event of a disaster. Methods: The target was 41 local public hospitals, including 35 regional medical centers and 6 Red Cross hospitals nationwide. We delivered a questionnaire to 41 medical facilities and collected data from 32 regional public hospitals that received responses. Results: In order to respond to safety accidents, a survey was conducted on infections, falls, patient identification, and incorrect connections for medical accidents, and for in-hospital accidents, a survey was conducted on entrapment, collision, water leaks, falling objects, and crime prevention. For natural disasters, we investigated the response environment for typhoons, floods, and snow damage, and for social disasters, we investigated the response environment for fire, power outages, and radiation damage. Implications: We hope that it will be used as basic data for developing standards and creating hospital facilities and environments that are safe for everyone to respond to various disasters and prevent patient safety accidents in the future.

Overview of separate effect and integral system tests on the passive containment cooling system of SMART100

  • Jin-Hwa Yang;Tae-Hwan Ahn;Hong Hyun Son;Jin Su Kwon;Hwang Bae;Hyun-Sik Park;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.1066-1080
    • /
    • 2024
  • SMART100 has a containment pressure and radioactivity suppression system (CPRSS) for passive containment cooling system (PCCS). This prevents overheating and over-pressurization of a containment through direct contact condensation in an in-containment refueling water storage tank (IRWST) and wall condensation in a CPRSS heat exchanger (CHX) in an emergency cool-down tank (ECT). The Korea Atomic Energy Research Institute (KAERI) constructed scaled-down test facilities, SISTA1 and SISTA2, for the thermal-hydraulic validation of the SMART100 CPRSS. Three separate effect tests were performed using SISTA1 to confirm the heat removal characteristics of SMART100 CPRSS. When the low mass flux steam with or without non-condensable gas is released into an IRWST, the conditions for mitigation of the chugging phenomenon were identified, and the physical variables were quantified by the 3D reconstruction method. The local behavior of the non-condensable gas was measured after condensation inside heat exchanger using a traverse system. Stratification of non-condensable gas occurred in large tank of the natural circulation loop. SISTA2 was used to simulate a small break loss-of-coolant accident (SBLCOA) transient. Since the test apparatus was a metal tank, compensations of initial heat transfer to the material and effect of heat loss during long-term operation were important for simulating cooling performance of SMART100 CPRSS. The pressure of SMART100 CPRSS was maintained below the design limit for 3 days even under sufficiently conservative conditions of an SBLOCA transient.

A case of syncope in a villager with hypertrophic cardiomyopathy after hydrogen sulfide exposure by an unauthorized discharge of wastewater

  • Hyeonjun Kim;Seunghyeon Cho;Inho Jung;Sunjin Jung;Won-Ju Park
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.34.1-34.8
    • /
    • 2023
  • Background: Hydrogen sulfide is a toxic substance that humans can be exposed to occupationally, and cases of hydrogen sulfide poisoning of workers in industrial sites are commonly reported. However, there have been no cases of poisoning of the public due to an unauthorized discharge of wastewater, so it is important to describe this incident. Case presentation: In a small village in Jeollanam-do, Republic of Korea, accounts of a terrible stench had been reported. A 26-year-old man who lived and worked in a foul-smelling area was taken to the emergency room with a headache, dizziness, nausea, and repeated syncope. A subsequent police and Ministry of Environment investigation determined that the cause of the stench was the unauthorized discharge of 9 tons of wastewater containing hydrogen sulfide through a stormwater pipe while the villagers were sleeping. The patient had no previous medical history or experience of symptoms. Leukocytes and cardiac markers were elevated, an electrocardiogram indicated biatrial enlargement, left ventricular hypertrophy, and corrected QT interval prolongation. Myocardial hypertrophy was detected on a chest computed tomography scan, and hypertrophic cardiomyopathy was confirmed on echocardiography. After hospitalization, cardiac marker concentrations declined, symptoms improved, and the patient was discharged after 7 days of hospitalization. There was no recurrence of symptoms after discharge. Conclusions: We suspect that previously unrecognized heart disease manifested or was aggravated in this patient due to exposure to hydrogen sulfide. Attention should be paid to the possibility of unauthorized discharge of hydrogen sulfide, etc., in occasional local incidents and damage to public health. In the event of such an accident, it is necessary to have government guidelines in place to investigate health impact and follow-up clinical management of exposed residents.

A Study for Implementation of Autonomous Maritime Radio Devices using LMX2571 (LMX2571을 활용한 자율해상무선기기 기술 구현에 관한 연구)

  • Chong-Lyong, Pag
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.2
    • /
    • pp.217-225
    • /
    • 2024
  • Even after the introduction of Global Maritime Distress and Safety System (GMDSS), many maritime accidents occur. A method of transmitting a rescue signal when a person falls into the water from a ship is currently being researched and developed in various ways, but no products have been developed that use frequencies allocated for maritime mobile service. Accordingly, in this study, we designed and produced a man-over-board (MOB) device by applying Group B AMRD technologies, which were adopted through the latest revision of the International Telecommunication Union (ITU). In addition, a receiver and user interface were built to verify the performance of the transmitter, and we confirmed that it can be used in conjunction with existing electronic charts. This MOB device satisfies the general and technical requirements of Group B AMRD using AIS technology and uses integrated components for miniaturization for easy portability in a maritime environment. We expect that it will achieve excellent AIS communication and be essential in rapid response and safety in emergency scenarios.

Design of Underwater Cables Applicable to Submarine(KSS-III Batch-II) Navigation Radar (잠수함 항해레이더 적용 가능한 수중케이블 설계)

  • Kihong Lee;Woojin Song;Myeonghoon Jo;Hyebin Kim;Jaenam Yim;Insung Park
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.596-610
    • /
    • 2024
  • Since the creation of the first submarine telegraph cable connecting England and France in 1850, today, due to the rapid development of the Internet and Communications fields, the demand for submarine communication cables has increased and continues to develop. Submarine cables are designed and manufactured to be suitable for the maritime environment, and many parts are imported from overseas, and several domestic cable manufacturers are producing them for commercial purposes. Field-proven and reliable commercial submarine communication cable technology is also being applied to the military field, and is especially actively utilized in naval surface ships and submarines. This paper is about the design of an underwater cable applicable to submarine(KSS-III Bach-II) navigation radar and also is to secure the performance of an underwater cable with bending durability in extreme marine environments, emergency diving, and repeated mast raising and lowering. Finally, we hop that the domestic development of underwater cables will help improve the performance of navigation radars for submarines.

Flood Hazard Map and EAP Establishment Against Dam/Levee Failure (댐.제방 붕괴에 대비한 홍수위험지도 및 EAP 작성)

  • Han, Kun-Yeun;Kim, Keuk-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.291-295
    • /
    • 2006
  • 비상대처계획(EAP, Emergency Action Plan) 수립 및 홍수위험지도 작성의 목적은 댐.제방 붕괴 등 비상상황이 발생하였을 때 하류부의 생명과 재산 손실을 최소화하기 위한 것으로서 댐 운영 및 관리책임자가 극한홍수 및 지진발생 조건하에서 댐의 물리적, 지형적, 구조적 특성에 따른 발생 가능한 비상상황을 예상하고 이에 효율적으로 대처하기 위한 가능한 최선의 사전계획을 수립하는 것이다. 또한, 댐의 비상상황에 대처하기 위한 비상대처계획 수립 의무화 및 이에 대한 실제적인 모의훈련 등에 필요한 기초자료를 체계적으로 제공하고자 함에 있다. 국내에서 EAP를 수립하여야 할 대상 댐 저수지는 한국수자원공사에서 관리하는 다목적댐, 생공용수댐과 한국농촌공사에서 관리하는 농업용저수지, 한국수력원자력주식회사에서 관리하는 수력발전댐 및 지방자치단체에서 관리하는 댐 등이 해당된다. 제방의 경우 인구가 밀집되어 있는 전 지역이 그 대상이 될 수 있다. EAP의 주요 내용에는 만약에 발생할 수 있는 붕괴 사고시 인명의 손실이나 재산상의 피해를 발생시킬 수 있는 댐 저수지들에 대해서는 EAP를 수립하거나 갱신하기 위한 지침들이 포함되어 있어야 한다. 댐으로부터의 하류 연안지역의 개발이나 소유권은 다양하며, 이로 인해 댐의 운영이나 붕괴로 인한 잠재적 인명손실 또한 다양할 수 있다. 따라서 모든 EAP는 댐, 저수지 하류부 현장 조건에 맞도록 구성되어야 한다. EAP 수립의 주체는 댐 및 저수지 관리자이며 EAP에는 비상상황 확인, 평가, 등급분류, 비상연락체계 및 경보전달체계 수립, 비상시 응급행동요령, 홍수범람예측지도 작성, 비상주민대피계획 및 훈련방안, 부록, 주기적 또는 필요시마다 보완 계획 등이 포함되어야 하며, EAP의 주요 구성요소인 홍수위험지도에는 홍수위험정보 및 대피정보를 제시함으로써 실제 주민 대피계획시 실제적이고 효율적인 대피계획 수립에 활용될 수 있다. 있는 기술가치평가 모형의 구축이 요구된다. 이에 본 연구에서는 효율적인 R&D 투자 정책 수립과 정부정책수립에 기여하고자 AHP(Analytic Hierarchy Process, 계층 분석 과정)기법을 이용, 수자원의 지속적 확보기술의 특성에 따른 4개의 평가기준과 26개의 평가속성으로 이루어진 2단계 기술가치평가 모형을 구축하였으며 2개의 개별기술에 대한 시범적용을 실행하였다.하는 것으로 추정되었다.면으로의 월류량을 산정하고 유입된 지표유량에 대해서 배수시스템에서의 흐름해석을 수행하였다. 그리고, 침수해석을 위해서는 2차원 침수해석을 위한 DEM기반 침수해석모형을 개발하였고, 건물의 영향을 고려할 수 있도록 구성하였다. 본 연구결과 지표류 유출 해석의 물리적 특성을 잘 반영하며, 도시지역의 복잡한 배수시스템 해석모형과 지표범람 모형을 통합한 모형 개발로 인해 더욱 정교한 도시지역에서의 홍수 범람 해석을 실시할 수 있을 것으로 판단된다. 본 모형의 개발로 침수상황의 시간별 진행과정을 분석함으로써 도시홍수에 대한 침수위험 지점 파악 및 주민대피지도 구축 등에 활용될 수 있을 것으로 판단된다. 있을 것으로 판단되었다.4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에 있어서 시장수익률을 평균적으로 초과할 수 있는 거래전략은 존재하므로 이러한 전략을 개발 및 활용할 수 있으며, 특히, 한국주식시장에 적합한 거래전략은 반전거래전략이고, 이 전략의 유용성은 투자자가 설정한 투자기간보다 더욱 긴 분석기간의 주

  • PDF