• Title/Summary/Keyword: Emergency water

Search Result 442, Processing Time 0.026 seconds

Abnormal Changes in Groundwater Monitoring Data Due to Small-Magnitude Earthquakes (지하수 모니터링 이상변동 자료를 이용한 소규모 지진 영향 유추)

  • Woo, Nam C.;Piao, Jize;Lee, Jae-Min;Lee, Chan-Jin;Kang, In-Oak;Choi, Doo-Houng
    • The Journal of Engineering Geology
    • /
    • v.25 no.1
    • /
    • pp.21-33
    • /
    • 2015
  • This study tests the potential of detecting small-magnitude earthquakes (~M3.0) and their precursors using a long-term groundwater-monitoring database. In groundwater records from April to June 2012, abnormal changes in water level, temperature, and electrical conductivity were identified in the bedrock monitoring wells of the Gimcheon-Jijwa, Gangjin-Seongjeon, and Gongju-Jeongan stations. These anomalies could be attributed to the M3.1 earthquake that occurred in the Youngdeok area on May 30th, although no linear relationship was found between the scale of changes and the distance between each monitoring station and the epicenter, which is attributed in part to the wide screen design of the monitoring wells. Groundwater monitoring networks designed specifically for monitoring earthquake impacts could provide better information on the safety of underground space and on the security of emergency water-resources in earthquake disaster areas.

Development of Water Hammer Simulation Model for Safety Assessment of Hydroelectric Power Plant (수력발전설비의 안전도 평가를 위한 수충격 해석 모형 개발)

  • Nam, Myeong Jun;Lee, Jae-Young;Jung, Woo-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.760-767
    • /
    • 2020
  • Sustainable growth of hydroelectric power plants is expected in consideration of climate change and energy security. However, hydroelectric power plants always have a risk of water hammer damage, and safety assurance is very important. The water hammer phenomenon commonly occurs during operations such as rapid opening and closing of the valves and pump/turbine shutdown in pipe systems, which is more common in cases of emergency shutdown. In this study, a computational numerical model was developed using the MOC-FDM scheme to reflect the mechanism of water hammer occurrence. The proposed model was implemented in boundary conditions such as reservoir, pipeline, valve, and pump/turbine conditions and then applied to simulate hypothetical case studies. The analysis results of the model were verified using the analysis results at the main points of the pipe systems. The model produced reasonably good performance and was validated by comparison with the results of the SIMSEN package model. The model could be used as an efficient tool for the safety assessment of hydroelectric power plants based on accurate prediction of transient behavior in the operation of hydropower facilities.

Corrosion Stability of Iron Artifacts after Treating with Water Treatment (수처리제를 사용한 철제유물의 부식 안정성 연구)

  • Jeong, Ji Hae
    • Journal of Conservation Science
    • /
    • v.33 no.5
    • /
    • pp.381-390
    • /
    • 2017
  • Desalination is the main focus of the stabilization of iron artifacts. However, drawbacks such as re-corrosion are noted due to the uncertainty in the elimination of the corrosive factors and artifacts. Several studies have been carried out on the effects of corrosion inhibitors to overcome these shortcomings. In this study, the effects of type 3 water treatment on corrosion inhibitors were investigated. Surfaces of samples that contained film corrosion inhibitors on their surfaces were analyzed. The results revealed that the surface rust was removed from the sample of type 1 No. 2 that was mainly composed of phosphate. The average weight reduction rates of re-corrosion samples were 0.58, 0.03, and 0.07% for type 1 No. 2, type 2 No. 2, and type 3 No. 2 respectively. The changes in the $Cl^-$ ion, a corrosive agent were found to be 28.60, -4.08, and -1.94 ppm for type 1 No. 2, type 2 No. 2, and type 3 No. 2 respectively. The water-treated films were analyzed by X-ray photoelectron spectroscopy (XPS). It was found that type 2 No. 2 had less Fe the basis metal, than that in type 3 No. 2 indicating much better film. Moreover, Si content was higher in type 2 No. 2, based on the silicate content, than in type 3 No. 2. They are speculated to be the reason or the formation of a better film. Type 1 No. 2, which is mainly composed of phosphate, would be inappropriate as a metal artifact conservation treatment. It was determined that type 2 No. 2 and type 3 No. 2 water treatments, which are mainly composed of silicate, provided excellent corrosion inhibiting effects. Corrosion inhibitors could be used as emergency treatment agents during the excavation of iron artifacts.

A Study on Introduction of Levee Accreditation Program (제방 인증제 도입에 관한 연구)

  • Lee, Sang-Ho;Kang, Tae-Uk;Yu, Kwon-Kyu;Lee, Nam-Joo;Lee, Jae-Hyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1739-1743
    • /
    • 2009
  • 현재 국내에는 하천시설물의 인증과 관련한 제도와 법령이 마련되어 있지 않다. 하천시설물과 관련된 인증 제도는 효율적인 하천시설물의 유지관리를 가능하게 하고, 치수 안전성 증대에 기여할 수 있다. 본 연구는 미국의 제방 인증(levee accreditation) 제도를 분석하여 국내에 적용하는 방안에 관한 것이다. 미국의 연방 재난 관리국(Federal Emergency Management Agency; FEMA)은 국가 홍수 보험 프로그램(National Flood Insurance Program; NFIP)을 관리하고 있는데, 그의 일환으로 제방 인증 제도를 시행하고 있다. 제방의 인증은 제내지를 보호하는 제방 시스템이 100년 빈도의 홍수에 대한 방어 능력이 있는지를 기술적으로 검토하는 것이다. 여기서 제방 시스템이란, 제방, 홍수벽, 수문 장치, 펌프시설, 암거, 내수 배제 시설 등 홍수로부터 제내지를 보호하기 위한 모든 시설을 포함한다. 미국은 제방 인증을 위한 제도로서 연방 규정 조례(code of federal regulation; CFR)를 두어 제방 시스템의 설계, 운영, 유지관리의 기준을 마련하였다. 제방 인증을 신청하는 기관은 연방 규정 조례에서 정의된 제방 시스템의 운영 및 유지관리에 관한 문서를 갖추어야하고, 공학적인 설계 기준에 대하여 면밀히 검토되어야 한다. 운영 및 유지관리에 관한 사항은 수문과 내수배제 시스템을 포함한 제방 시스템의 홍수 시 운영 지침과 운영실적, 유지보수 지침과 점검 보고서 등이다. 공학적인 설계 기준에 대한 검토사항은 제방의 여유고, 수문, 호안, 제방과 기초의 안정성, 침하, 내수배제에 관한 분석 결과이다. 이러한 제방의 인증에 필요한 기술적인 검토 자료와 관련 문서는 등록된 전문 기술자나 제방의 설계와 시공능력을 갖춘 연방 기관을 통해 보증(certification) 되어야 한다. 현재, 미국에서 제방의 보증을 결정하는 대표적인 기관은 미 공병단(U.S. Army Corps of Engineers; USACE)이다. 제방 보증의 유효기간은 최대 10년이지만 검사와 평가가 지속되고, 유효 기간 만료 전이라도 언제든지 재검토될 수도 있다. 또한, 제방 시스템 전체에 대하여 보증 여부를 결정하고, 개별 시설에 대한 보증이나 조건부 보증은 수행하지 않는다. 국내에 제방 인증 제도를 도입하기 위해서는 제방 인증에 관한 절차, 수행 기관, 수행 방법 등에 대한 규정과 제도가 마련되어야 하고, 현재 국내에서 수행되고 있는 하천시설물의 안전도 검사 방법을 포함한 평가 지표와 평가 기술에 대한 인증 표준화가 요구된다.

  • PDF

Study on Improving Reliability of Biomonitor by Using CCD Camera (CCD카메라를 이용한 생물감시장치의 독성자료 신뢰성 향상에 관한 연구)

  • Kim, Hyun-Chang;Kim, Young-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1351-1357
    • /
    • 2010
  • Water monitoring equipments using daphnia can be used to monitor the pollution levels of a country's main rivers. Such equipments should be capable of providing a prompt warning about increase in the contamination levels, which is evaluated on the basis of impulse number or toxicity index. As unmanned remote control equipments, they must provide reliable pollution monitoring results for each season and for the annual physical changes in each river. Two different equipments based on the impulse number and toxicity index showed different results for the operating rates and for the number of emergency checks required even though both were operated at the same conditions. The results are affected by many parameters such as the presence of any air bubbles and the microscopic pressure. The purpose of this study is to develop a method that can reduce the effect of bubbles or microscopic pressure on the monitoring data. We expect to achieve reliable monitoring data for water pollutants irrespective of the location of the equipment setup.

Detailed Design for 25bar-class Biogas Compression Supplying System (25BAR급 바이오가스 고압 압축공급시스템 상세설계)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Yun, Eun-Young;Lee, Jung-Bin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.173.1-173.1
    • /
    • 2011
  • The high fuel flexibility of gas turbine power system has boosted their use in a wide variety of applications. Recently, the demand for biogas generated from the digestion of organic wastes and sewage waste water as a fuel for gas turbines has increased. We investigated the performance of high pressure biogas compression system and operating conditions for supplying biogas. The total flow per minute of biogas from food waste water digestion tank is $54Nm^3$. The main type of biogas compression system is the reciprocating system and screw type system. The target of biogas mechanical data is the as belows; inlet pressure 0.045bar, supplying biogas temperature is $30{\sim}60^{\circ}C$, and final pressure is above the 25 bar. Also, inlet conditions of biogas consist of CH4 48.5%~83%, $H_2S$ Max. 500ppm, $NH_3$ Max. 1,500ppm and Siloxane 2.7~4.6ppm. The boosting Blower system raises a pressure from 0.045bar to 1bar before main compressor. The main system lay out of reciprocating consisits of compressor driver, filter, cooling system, blowdown vessel, control system and ESD(Emergency Shut Down) system. And an enclosure package needs to be installed for reducing noise up to 75dB. The system driver is the electronic motor of explosion proof type. Forthe compressor system reliable operation, the cleaning system something like particulate filter needs to be set up in the inlet of compressor and Coalescing Filter in the outlet of compressor. Particulate Filter has to be removed above $10{\mu}m$ size of the particles in biogas. The coalescing filter(Micofine Borosilicate Glass Fibers Filter treated phenol acid) also removes moisture and oil of above $0.3{\mu}m$ to be involved in high pressure biogas up to 90%~98%.

  • PDF

Loss of Aquaporin-3 in Placenta and Fetal Membranes Induces Growth Restriction in Mice

  • Seo, Min Joon;Lim, Ju Hyun;Kim, Dong-Hwan;Bae, Hae-Rahn
    • Development and Reproduction
    • /
    • v.22 no.3
    • /
    • pp.263-273
    • /
    • 2018
  • Aquaporin (AQP) 3, a facilitated transporter of water and glycerol, expresses in placenta and fetal membranes, but the detailed localization and function of AQP3 in placenta remain unclear. To elucidate a role of AQP3 in placenta, we defined the expression and cellular localization of AQP3 in placenta and fetal membranes, and investigated the structural and functional differences between wild-type and AQP3 null mice. Gestational sacs were removed during mid-gestational period and amniotic fluid was aspirated for measurements of volume and composition. Fetuses with attached placenta and fetal membranes were weighed and processed for histological assessment. AQP3 strongly expressed in basolateral membrane of visceral yolk sac cells of fetal membrane, the syncytiotrophoblasts of the labyrinthine placenta and fetal nucleated red blood cell membrane. Mice lacking AQP3 did not exhibit a significant defect in differentiation of trophoblast stem cells and normal placentation. However, AQP3 null fetuses were smaller than their control litter mates in spite of a decrease in litter size. The total amniotic fluid volume per gestational sac was reduced, but the amniotic fluid-to-fetal weight ratio was increased in AQP3 null mice compared with wild-type mice. Glycerol, free fatty acid and triglyceride levels in amniotic fluid of AQP3 null mice were significantly reduced, whereas lactate level increased when compared to those of wild-type mice. These results suggest a role for AQP3 in supplying nutrients from yolk sac and maternal blood to developing fetus by facilitating transport of glycerol in addition to water, and its implication for the fetal growth in utero.

Improvement of National Risk Alarm 4-Stage Criteria for Flood Disaster (홍수재난 대응을 위한 국가위기경보 4단계 설정기준 개선)

  • Lee, Sookyong;Park, Jae-Woo;Oh, Eun-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.3
    • /
    • pp.369-377
    • /
    • 2018
  • EAP, which is operated on the frame of Risk Alarm 4-stage of National Risk Management Guideline, is a critical method in order to promptly respond to disasters. Korea Flood Control Office issues major and moderate flood alarm at each river station by respectively 50% and 70% of design flood discharge in terms of watermark or sea level, however, the criteria deciding major and moderate floods are vague for field managers to control the disaster situations. On the other hand, Japan and USA use river water level as a main criterion in order to classify the stage of flood disaster, which is higher design flood level than Korea. Thus, the authors analyzed domestic and oversea EAP guidelines and suggested improved criteria showing easy display method and raising the criteria of flood level for reflecting more effective action plans through testing a simulation training on the test-bed.

Evaluation on the leakage of ground-water through fractured rock under a spillway (여수로 구조물 하부 암반 내 발달한 절리들을 통한 지하수 누수량 분석)

  • Kim, Hyoung-Soo;Lee, Ju-Hyun;Jeong, Ui-Jin;Lee, Joong-Woo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.69-74
    • /
    • 2006
  • Recently, spillways are need to control stable water level for supporting main dams because of floods by unusual change of weather such as Typhoon Rusa. This study has been focused on the amount of leakage through the rock mass distributed fractures and joints under the opened emergency spillway. It is very important to evaluate the amount of leakage as these affect stability of spillway by interaction between effective stress and pore pressure. The commercial program MAFIC has been used for analyzing groundwater flow in fractured rock mass. The results showed that the values of range, average and deviation of leakage were $2.85\sim\;3.79\times10^{-1}$, $3.32\times10^{-1}$ and $1.70\times10^{-2}\;m^3/day/m^2$ respectively. Secondary, we have estimated the effect of grouting after the transmissivity$(T_f)$ of joint 1 as main pathway of leakage known from above results was changed from $1.78\times10^{-7}$ to $1.59\times10^{-9}\;m^2/s$. The results showed that the values of range, average and deviation of leakage were $7.80\times10^{-4}\sim1.53\times10^{-3}$, $1.18\times10^{-3}$ and $1.32\times10^{-4}\;m^3/day/m^2$ respectively. As the result, the amount of leakage after grouting has been decreased by a ratio of 1 to 277.

  • PDF

A Study on Estimation of Target Precipitation in Seoul using AWS minutely Rainfall Data (AWS 분(分) 단위 강우자료를 이용한 서울지역 특성에 따른 행정자치 구(區)별 목표강우량 산정에 관한 연구)

  • Kim, Min-seoka;Son, Hong-mina;Moon, Young-il
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.1
    • /
    • pp.11-18
    • /
    • 2016
  • It is very important to decide probability precipitation that is used as hydraulic structure design and target rainfall for urban disaster prevention. Especially, National Emergency Management Agency (NAMA) announced target rainfall from probability precipitation in korea on city and district level. It make use to performance evaluation of disaster prevention and planning of development for disasters prevention capacity target. In this study was calculated target rainfall that is duration 1~3 hour based unit of gu (borough) by point and regional frequency analysis using rainfall data of Surface Synoptic Stations (SSS) and Automatic Weather Stations (AWS). The result of this study can utilized as a reference to related business such as disaster capability assessment and achievement of prevention capacity target against disasters. And it also will be contribute to establishment of prevention capacity target against disasters.