• Title/Summary/Keyword: Emergency stop device

Search Result 17, Processing Time 0.025 seconds

Make-up of a Simulator having the Same Brake Characteristics as Actual Elevator Emergency Stop Device

  • Nakagawa, Toshiko;Suzuki, Kazuo;Haga, Akira;Hayakawa, Naoya
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.4
    • /
    • pp.454-459
    • /
    • 2013
  • The authors study a novel type of elevator emergency stop device which enables to soften impact force at an emergency halt. A new structure of emergency stop devices has been already proposed by our laboratory and also its characteristics has been already proposed by our laboratory and also its characteristics has been shown by digital simulations[1]. In order to confirm the actual effects of our proposed emergency stop device, we have made up a simulator having the same characteristics as the conventional emergency stop device to accomplish the experiments from now on. In this paper, this process is introduced.

A Development and Characteristics of Remote Emergency Stop Device for Conveyors (컨베이어용 리모트 비상정지장치 개발 및 특성)

  • Lee, Jun-Suk
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.14-19
    • /
    • 2011
  • Conveyors cause a high serious and fatal injuries in the industry. Every year people are hurt or killed as a result of accidents on conveyors. Most accidents occur during operation and maintenance when employees are working on moving, unguarded conveyors or when the conveyors starts unexpectedly. In 2008 there were 486 reported injures ranging from fatalities to injures. Of these 486 reported accidents, 8 were fatalities, 66.9%(325) of reported accidents occurred in manufacturing company and 43.8%(213) occurred at the belt conveyors. The objective of this study was to invent the remote emergency stop device because industrial accidents mainly occur at blind spots where usually do not have any safety guard or device rather than the normal working places. In principle, this new device will use with the existing safety system. Then, it will be powerful safety system for preventing injuries related with conveyors.

A Study on the Multi-Joint Rehabilitation System of an Industrial Robot

  • Lee, Yong-Seok;Jang, Jae-Ho;Sim, Hyung-Joon;Han, Chang-Soo;Han, Jung-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.92-95
    • /
    • 2004
  • This study proposes an industrial rehabilitation robot system which can exercise two joints in 3 dimensional spaces. The robot kinematics analysis and the results of studies on each joint for the rehabilitation robot could verify possibility of rehabilitation motion to exercise a joint. The force and torques sensor not only measures a rehabilitation performance of subjects between the abnormal limb and the manipulator, but also carries out an important function of safety device to prevent accidents. Also, limit sensors and emergency stop switch are used for high safety in this system. In this real test, the possibility of rehabilitation robot system is evaluated by C&R ARM I which is similar to upper-limb.

  • PDF

Reduction Plan for nip accidents by a Roller Machine (산업용 로울러기의 협착재해 감소방안)

  • 박재범;강동규;김두현
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2003
  • The roller machines installed in the industrial field are operated under hazardous conditions due to no safety devices available, human error during operation, defective safety devices, and inadequate regulation even in case that safety devices are provided. Up to now, most roller machines installed in domestic field are provides with band breaking system as a safety device. In this study, the emergency stop distance is measured within the limit of domestic regulation but violates a foreign regulation(EN1417). Consequently, it is concluded that the roller machines with a band breaking system have high possibility of death or serious injury of the operator and the system should be improved with the introduction of additional safety devices. This thesis suggests the safety measures suitable for the roller machines with different drive systems based on the experiment results. The use of the newly developed safety system has been tested on many cases.

Analysis of EMI Between Overlapped Railway Signalling Systems and Its Countermeasure (철도신호시스템 중첩운영으로 인한 전자파장해현상 분석 및 대책)

  • Kho, Young-Hwan;Yoon, Sun-Ho;Choi, Kyu-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1116-1122
    • /
    • 2009
  • ATS(Automatic Train Stop) system makes train stop when it runs over the speed limit and ensure the safe operation of train. Seoul Metro line 2 in Korea, which started its passenger service in 1982, has adopted ATS system for its signaling system. The ATS system has only a train stop function at the time of emergency, and Seoul Metro is planning to replaced them with ATC(Automatic Train Control)/ATO(Automatic Train Operation) system which can provide the dedicated speed control for headway reduction and automatic operation of train. Until all the ATS system is replaced with the new ATC system, both systems are to operate simultaneously at the same metro line. In this situation, ATS system sometimes reveals improper operation: train stops suddenly without any obstacles in front of it. These emergency stops cause interruption of passenger service, and abnormal abrasion of wheels and rail. This paper makes it clear that these interruptions are caused by EMI phenomena between ATS on-board device and ATC wayside device : Signal current flowing in AF track circuit of ATC is turn out to be a EMI source that prevent normal operation of the ATS on-board device. Although the two systems have different frequency-ranges (ATS system has frequency range between $78{\sim}130$[kHz] and ATC system has frequency range between $9.5{\sim}16.5$[kHz]), it turned out that EMI phenomena appears between the both systems. This is investigated by measuring the output signal from ATS on-board device passing over ATC wayside device. The FFT(Fast Fourier Transform) analysis of the signal reveals that AF track circuit signal is transmitted to the ATS on-board device and induce noise causing improper operation. The countermeasures to the EMI phenomena are examined in three ways; blocking EMI transmission, enforcement of EMS (Electromagnetic Susceptibility) of ATS on-board device, and blocking the EMI source. It is suggested that the practical solution be blocking EMI source temporarily, that is breaking AF track circuit signal when the trains with ATS on-board device pass over it. To this purpose, TODS(Train Occupation Detection System) is developed, and has made a success in preventing the EMI problem of Seoul Metro line 2.

A Study on the Design and Control Method for Unmanned Ground Vehicle System (무인 자율 주행 차량 시스템 설계 및 제어에 관한 연구)

  • Moon, Hee-Chang;Park, Myung-Wook;Kim, Jung-Ha
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.5
    • /
    • pp.446-455
    • /
    • 2010
  • The research presented covers the design and control method of unmanned ground vehicle (UGV). An electric vehicle is used and is driven by DC motor. The power system on the UGV has been adjusted and actuators have been installed for steering and brake automation. A toggle switch is implemented to easily switch between manual and autonomous states. The UGV state is monitored by a velocity sensor, as well as steering and brake position sensors. An emergency stop device was designed and installed to quickly and safely stop the UGV. Different control methods, including the PID controller, were studied for improved steering responsiveness, and results were confirmed through experimentation. Satisfactory performance was achieved and several possible areas of future research have arisen.

Multi-modal Wearable Device for Cardiac Arrest Detection (심정지 감지를 위한 다생체 신호 측정 웨어러블 디바이스 개발)

  • Ahn, Hyun Jun;You, Sung Min;Cho, Kyeongwon;Park, Hoon Ki;Kim, In Young
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.330-335
    • /
    • 2017
  • Cardiac arrest is owing to the failure of the heart that makes the blood circulation stop. Arrested blood circulation prevents the supply of the oxygen and the glucose and it results the loss of consciousness and, finally, brain death. Many public institution installed the AED for emergency treatment, but, it is not efficient when the patient is alone. In this paper, we made multiplexed wearable device for cardiac arrest detection. With this device, we measure the individual's electrocardiography, heart sound and motion. If the cardiac arrest is detected, the device make a warning horn and transmit the signal for defibrillation. We obtain 98.33% of ECG data, 94.5% of PCG data and 98.38% of IMU data accuracy for each evaluation and 93.33% accuracy for integrated evaluation.

Development of Onshore Offshore Tower Elevator with load distribution endless winder and integrated control panel (하중 분산형 엔드리스 와인더와 통합형 제어반을 적용한 육상 해상 풍력타워 승강기 개발)

  • Lee, Sang-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.711-719
    • /
    • 2019
  • At present, wind power is the fastest growing technology in the world. The domestic market depends heavily on imports for wind tower lift. so it manage through the overseas maker. The lift manufacture, establishment and maintenance utility is increasing, localization development of one wind tower lift is necessary with domestic fundamental base technique. In this paper, we will study the components necessary for the development of onshore offshore wind tower elevators, which are currently dependent on total imports, in line with the high growth of the wind market and the enlargement of the wind power generators. First of all, endless winders and cabins, which are the core components of the offshore wind tower lift, were examined for the components that affect the structural safety. Structural analysis was performed on Sheave, which is responsible for most of the lift lifting loads, and Block Stop, a safety device that prevents the cabin from falling in an emergency. The structural suitability was evaluated by comparing with the safety factor. In addition, the on-board control panel combines the control panel of the elevator and the drive motor driving the endless winder for efficient control of the offshore wind tower lift. The addition of features improves ride comfort at departure.

The current status and legal review of advanced airway management implemented by 119 EMTs (소방 119구급대원에 의해 시행된 전문기도관리 현황 및 법적 고찰)

  • Park, Si-Eun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.2
    • /
    • pp.169-186
    • /
    • 2021
  • Purpose: This study aimed to analyze the data from public information disclosure about pre-hospital advanced airway management and identify the problem by considering domestic laws and guidelines. Methods: Data were collected between 2017 and 2018 and analyzed using SPSS 25.0. Then, the problems of the analysis results based on the relevant laws and practical guidelines were reviewed. Results: The review of domestic laws and practice guidelines revealed that ambulance nurses can implement supraglottic airway device only under the following three conditions: ① smart advanced life support pilot project area, ② trained to insert I-Gel, and ③ member of a special ambulance. In total, 21,574 cases of advanced airway management (endotracheal intubation: 2,428, I-Gel: 18,502, LMA : 499, KING AIRWAY: 144) were reported. In many cases, advanced airway management was performed by ambulance nurses who did not meet the above conditions, which was in violation of laws and guidelines. In addition, the prognosis of intubated patients was not followed up. Conclusion: The Korea National Fire Agency must stop all unlicensed medical practice by untrained, uneducated, and uncertified nurses and demand quality control programs for intubated patients.

A Safety Plan for the Pumping Station by Hydraulic Transient Analysis and Demonstration (과도수리현상 해석과 실증을 통한 펌프장 안정성 확보방안)

  • Ra, Beyong-pil;Kim, Jin-min;Lee, Dong-keun;Park, Jong-ho;Kim, Kyung-yup
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.5 s.32
    • /
    • pp.22-28
    • /
    • 2005
  • As the water supply facilities are recently getting larger, the domestic waterworks become multi-regional water supply system. Large water supply facilities generally consist of the intake pumping station, water treatment plant and water supply/distribution facilities. Although the pumping stations and the pipeline systems are used to pump up water, it often happens pipeline damage and flooding accident by the water hammer. In this paper, the intake pumping station is guaranteed by both the computer simulation and the field test analysis. This study is contributed to the safe operation program for the pumping station in which results of the adjustment on the safety plan of the pumping station, the air valve and the valve closing time.