• Title/Summary/Keyword: Emergency power

Search Result 751, Processing Time 0.031 seconds

Development of the Self-Build based Emergency Towers for Overhead Transmission Line (송전선로 비상복구용 자주조립식 철주 개발)

  • Byun Gang;Min Byeong Wook;Wi Hwa Bog;Park Jae Ung;Baek Soo Gon
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.494-496
    • /
    • 2004
  • Due to a typhoon named MAEMI on Sep12, 2004, 7 transmission towers collapsed and 3 were damaged in the Gyeongnam and Busan areas. These caused long-term black-outs in Goeje-do. When a transmission tower collapses or is damaged, Construction will take more than 2 months and this will be accompanied by long-term black-outs. Therefore a temporary iron pole is used in such emergencies. Current temporary rehabilitation angle steel iron Pole consistes of around 800 members, 2,800 bolts and it takes about 5 days to construct a temporary transmission line. Consiquently wide black-outs occur during the construction of the temporary transmission line. To reduce black-out time, the construction period must be reduced as much as possible. This paper presents new methods to reduce temporary transmission line construction time to within 48 hours by applying a self-reliance assembling method instead of the current man power assembling method and by modulizing each angle steel with duralumin.

  • PDF

RCD success criteria estimation based on allowable coping time

  • Ham, Jaehyun;Cho, Jaehyun;Kim, Jaewhan;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.402-409
    • /
    • 2019
  • When a loss of coolant accident (LOCA) occurs in a nuclear power plant, accident scenarios which can prevent core damage are defined based on break size. Current probabilistic safety assessment evaluates that core damage can be prevented under small-break LOCA (SBLOCA) and steam generator tube rupture (SGTR) with rapid cool down (RCD) strategy when all safety injection systems are unavailable. However, previous research has pointed out a limitation of RCD in terms of initiation time. Therefore, RCD success criteria estimation based on allowable coping time under a SBLOCA or SGTR when all safety injection systems are unavailable was performed based on time-line and thermal-hydraulic analyses. The time line analysis assumed a single emergency operating procedure flow, and the thermal hydraulic analysis utilized MARS-KS code with variables of break size, cooling rate, and operator allowable time. Results show while RCD is possible under SGTR, it is impossible under SBLOCA at the APR1400's current cooling rate limitation of 55 K/hr. A success criteria map for RCD under SBLOCA is suggested without cooling rate limitation.

Radiological Alert Network of Extremadura (RAREx) at 2021:30 years of development and current performance of real-time monitoring

  • Ontalba, Maria Angeles;Corbacho, Jose Angel;Baeza, Antonio;Vasco, Jose;Caballero, Jose Manuel;Valencia, David;Baeza, Juan Antonio
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.770-780
    • /
    • 2022
  • In 1993 the University of Extremadura initiated the design, construction and management of the Radiological Alert Network of Extremadura (RAREx). The goal was to acquire reliable near-real-time information on the environmental radiological status in the surroundings of the Almaraz Nuclear Power Plant by measuring, mainly, the ambient dose equivalent. However, the phased development of this network has been carried out from two points of view. Firstly, there has been an increase in the number of stations comprising the network. Secondly, there has been an increase in the number of monitored parameters. As a consequence of the growth of RAREx network, large data volumes are daily generated. To face this big data paradigm, software applications have been developed and implemented in order to maintain the indispensable real-time and efficient performance of the alert network. In this paper, the description of the current status of RAREx network after 30 years of design and performance is showed. Also, the performance of the graphing software for daily assessment of the registered parameters and the automatic on real time warning notification system, which aid with the decision making process and analysis of values of possible radiological and non-radiological alterations, is briefly described in this paper.

Optimization of an extra vessel electromagnetic pump for Lead-Bismuth eutectic coolant circulation in a non-refueling full-life small reactor

  • Kang, Tae Uk;Kwak, Jae Sik;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3919-3927
    • /
    • 2022
  • This study presents an optimal design of the coolant system of a non-refueling full-life small reactor by analyzing the space-integrated geometrical and electromagnetic variables of an extra vessel electromagnetic pump (EVEMP) for the circulation of a lead-bismuth eutectic (LBE) coolant. The EVEMP is an ideal alternative to the thermal-hydraulic system of non-refueling full-life micro reactors as it possesses no internal structures, such as impellors or sealing structures, for the transportation of LBE. Typically, the LBE passes through the annular flow channel of a reactor, is cooled by the heat exchanger, and then circulates back to the EVEMP flow channel. This thermal-hydraulic flow method is similar to natural circulation, which enhances thermal efficiency, while providing a golden time for cooling cores in the event of an emergency. When the forced circulation technology of the EVEMP was applied, the non-refueling full-life micro reactor achieve an output power of 60 MWt, which is higher than that achievable via the natural circulation method (30 MWt). Accordingly, an optimized EVEMP for Micro URANUS with a flow rate of 4196 kg/s and developed pressure of 73 kPa under a working temperature of 250 ℃ was designed.

Effect of Nursing Organizational Culture, Stress Coping, and Bullying on Clinical Nurses' Turnover Intention (임상간호사의 간호조직문화, 스트레스 대처, 직장 내 괴롭힘이 이직의도에 미치는 영향)

  • Song, Hyo-Suk;Lim, So-Hee
    • Korean Journal of Occupational Health Nursing
    • /
    • v.32 no.1
    • /
    • pp.9-19
    • /
    • 2023
  • Purpose: This study aimed to the investigate the relationship between nursing organizational culture, stress coping, bullying, and turnover intention among Korean hospital nurses; and to identify factors influencing turnover intention. Methods: The participants were 264 nurses working at three general hospitals in a metropolitan area in; South Korea. Data were collected using structured questionnaires from March 20 to June 21, 2021; and analyzed using the SPSS/WIN program. Results: Nurses' turnover intention was positively correlated with hierarchical -oriention (r=.28, p<.001), work -oriention (r=.14, p=.012), and bullying (r=.48, p<.001), whereas turnover intention was negatively correlated with relationship -oriention (r=-.41, p<.001), innovation -oriention (r=-.39, p<.001), and stress coping (r=-.09, p=.009). The factors influencing turnover intention were nursing organizational culture, bullying, age, position, and total working period; these had 44.0% explanatory power for turnover intention (F=14.00, p<.001). Conclusion: According to this study, addressing bullying and strengthening nursing organizational culture is essential to lower turnover intention among clinical nurses.

Implementation of the Living Alone Elderly People Protection System using Ubiquitous Sensor Networks (유비쿼터스 센서 네트워크를 이용한 독거노인 지킴이 시스템 구현)

  • Park, Hong-Jin
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.2
    • /
    • pp.41-48
    • /
    • 2010
  • Numerous researches are being made on applications based on ubiquitous sensor networks and super light, low power sensors. With the development of society, the aged population is expanding and living alone elders are one of important social issues in today's society. This paper implements the living alone elderly people protection system using ubiquitous sensor networks. By collecting and monitoring information on living alone elders using sensor nodes and sink nodes in web environment, we can perform more integrated management. The implemented living alone elderly people protection system can monitor living alone elders' situation and take actions promptly in emergency.

Impedance investigation of the surface film formed on aluminum alloy exposed to nuclear reactor emergency core coolant

  • Junlin Huang;Derek Lister;Xiaoliang Zhu;Shunsuke Uchida;Qinglan Xu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1518-1527
    • /
    • 2023
  • A method was proposed for in-situ evaluating the thickness and resistivity of the oxide/hydroxide film formed on the surface of aluminum alloy exposed to sump water formed in the containment after a loss-of-coolant accident. The evaluation entailed fitting a model for the film impedance, which has film thickness and other variables describing the resistivity profile of the film along its thickness direction as fitting parameters, to the practically measured electrochemical impedance data. The obtained resistivity profiles implied that the films formed at pHs25℃ 7, 8, 9, 10, and 11 all had a duplex structure; compared to the outer layer in contact with the solution, the inner layer of the film had a much higher resistivity and was inferred to be denser and provide most of the protectiveness of the film. Both the thickness and the total resistance of the film decreased with the increasing solution pH25℃, suggesting that the films formed in more alkaline solutions had less protectiveness against corrosion, consistent with the increasing aluminum alloy corrosion rates previously identified.

Optimized Boreoung Dam Emergency Diversion Tunnel Operation Rule Study, considering Water Quantity-BOD-Electric Power in Boreong Dam Water Supply Network (보령댐계통 물 공급망 운영에 있어서의 수량-수질(BOD)-전력을 고려한 보령댐 비상도수로 최적운영 Rule 연구)

  • Lim, Gun Muk;Kim, Sung Hoon;Ryoo, Kyung Sik;Jeong, Kwan Su
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.42-42
    • /
    • 2020
  • 충남서부권은 기상이변으로 강수량이 적고 가뭄이 심화되고 있는 반면, 신규수원 개발 적지 부족 등 용수공급에 어려움을 겪고 있다. 2015년부터 2016년까지 가뭄시 비상용수공급을 위해 비상도수로를 건설하였다. 이 비상도수로는 보령댐의 가뭄단계 상황기준으로 운영중에 있다. 가뭄단계 상황이 경계단계에 진입하면 도수로를 가동시작하여 관심단계 회복시에 중단하게 된다. 동 연구는 현재 운영중인 보령댐도수로의 가동Rule을 수량(이수안전도), 수질(BOD), 전력비용을 고려하여 시나리오별로(상시도수, 총 도수량대비 25%, 50%, 75%, 100%) 도수할 때 어느 도수 Rule이 수량-수질-에너지 넥서스 측면에서 가장 유리한지를 밝혀 내고자 하였다. 연구에 사용된 기초자료는 보령댐도수로 준공이후 2016년~2019년 도수실적 자료를 이용하였다. 수량(이수안전도) 검토는 MODSIM을 활용하였고, 수질개선효과는 실측 BOD를 기준으로 도수조건별로 오염부하량으로 검토하였다. 전력비용은 금강원수 도수년도별로 산정하여 분석하였다. 추가 연구결과를 통해 가뭄단계 상황기준, 월별 물관리 여건을 고려하여 기준향후 비상도수로 운영에 있어서 수량절량, 수질개선, 전력비용 절감을 기대할 수 있을 것이다.

  • PDF

Exploring the Relationship between the Kinetic Energy and Intensity of Rainfall in Sangju, Korea

  • Van, Linh Nguyen;Le, Xuan-Hien;Yeon, Minho;Thi, Tuyet-May Do;Lee, Giha
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.151-151
    • /
    • 2022
  • The impact of raindrops on the soil surface causes soil detachment, which may be estimated by measuring the kinetic energy (KE) of the raindrops. Since direct measurements of rainfall force on ground surfaces are not generally available, empirical equations are an alternative option to estimate KE from rainfall intensity (I), which has the greatest influence over soil erosion and is easily accessible. Establishing the optimal formulation for the relationship between kinetic energy and rainfall intensity has proven to be difficult. Thus, this research considered thirty-seven rainfall events observed from June 2020 to December 2021 using a laster optical disdrometer erected in Kyungpook National University to examine the characteristics of KE-I relationships. We concentrated our discussion on the formation of two different expressions of the KE, including KE expenditure (KEexp) and KE content (KEcon). The following conclusions were drawn: (1) We employed statistical analysis to demonstrate that the KEexp is more suitable expression for establishing an empirical rule between KE and I than the KEcon. (2) A power-law model was used to find the best correlation between KEexp-I relationship, whereas the best match between KEcon and I were found using an exponential equation.

  • PDF

A Mobile Application for Navigating the Optimal Escape Route in Accidents and Emergency Situations (모바일 어플리케이션을 이용한 재난상황 발생 시 최적 대피경로 설정)

  • Cho, Sung Hyun;Joo, Ki Don;Kang, Hoon;Park, Kyo Shik;Shin, Dong Il
    • Korean Journal of Hazardous Materials
    • /
    • v.3 no.1
    • /
    • pp.28-36
    • /
    • 2015
  • In early 2011, the Fukushima nuclear power plant had greater damage due to earthquake in Japan, and the awareness of safety has increased. In particular, special response systems should be required to handle disaster situations in plant sites which are likely to occur for large disasters. In this study, a program is designed to set up optimum escape routes, by a smart phone application, when a disaster situation occurs. This program could get information of the cumulative damage from sensors and display the escape route of the smallest damage in real-time on the screen. Utilizing our application in real-time evacuation has advantage in reducing cumulative damage. The optimal evacuation route, focusing on horizontal path, is calculated based on getting the data of fire, detected radioactivity and hazardous gas. Thus, using our application provides information of optimal evacuation to people who even can not hear sensor alarms or do not know geography, without requiring additional costs except fixed sensors or server network deployment cost. As a result, being informed of real-time escape route, the user could behave rapidly with suitable response to individual situation resulting in improved evacuation than simply reacting to existing warning alarms.