• Title/Summary/Keyword: Emergency generator

Search Result 200, Processing Time 0.032 seconds

Mechanical Characteristic Analysis of Coil Spring & Viscous Damper (Coil Spring & Viscous Damper System의 동특성분석)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.19-26
    • /
    • 2007
  • This paper presents the results of experimental studies of the mechanical characteristics of the Coil Spring and Viscous Damper system. The Coil Spring and Viscous Damper systems were selected for the isolation of Emergency Diesel Generator (EDG) which is located in Nuclear Power Plant (NPP). The Coil Spring and Viscous Damper systems were developed for the operating vibration isolation and seismic isolation for scaled Model EDG System. The damping properties of the viscous damper changes as the variation of velocity. Through this research nonlinear damping characteristics and the effective stiffness of coil spring and viscous damper system were evaluated.

Development of the Monitoring and Diagnosis Technique on Emergency Diesel Generator System (비상디젤발전기계통 상태감시 및 고장진단기술 개발)

  • Cho, Kwon-Hae;Rhyu, Keel-Soo;So, Myung-Ok;Park, Jong-Il;Son, Min-Su;Ahn, Jong-Kap;Lee, Yun-Hyung;Jang, Tae-Lin
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.777-782
    • /
    • 2005
  • The importance of emergency diesel generator(EDG) has confirmed in the safety evaluation of PSA and the study on aging of EDG has been progressed actively as a part of the project of nuclear plant aging research in the U.S.A. As the result, the concept of performance evaluation is being transferred from statistical analysis of test results to performance monitoring and trending analysis for monitoring of aging and reliability. Recently, the study related aging characteristic and reliability for EDGS has begun in Korea. Consequently, the efficient performance monitoring based systematic and integrated monitoring and failure diagnostic technology is necessary. In the research, the knowledge basis of monitoring parameters for EDGS is constructed, and the prototype monitoring and diagnosis system applicable to Pielstick EDG is developed.

  • PDF

Operational Availability Improvement through Online Monitoring and Advice For Emergency Diesel Generator

  • Lee, Jong-Beom;Kim, han-Gon;Kim, Byong-Sub;M. Golay;C.W. Kang;Y. Sui
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.264-270
    • /
    • 1998
  • This research broadens the prime concern of nuclear power plant operations from safe performance to both economic and safe performance. First emergency diesel generator is identified as one of main contributors for the lost plant availability through the review of plants forced outage records. The framework of an integrated architecture for performing modern on-line condition for operational availability improvement is configured in this work. For the development of the comprehensive sensor networks for complex target systems, an integrated methodology incorporating a structural hierarchy, a functional hierarchy, and a fault-system matrix is formulated. The second part of our research is development of intelligent diagnosis and maintenance advisory system, which employs Bayesian Belief networks (BBNs) as a high level reasoning tool incorporating inherent uncertainty use in probabilistic inference. Our prototype diagnosis algorithms are represented explicitly through topological symbols and links between them in a causal direction. As new evidence from sensor network development is entered into the model especially, our advisory of system provides operational advice concerning both availability and safety, so that the operator is able to determine the likely modes, diagnose the system state, locate root causes, and take the most advantageous action. Thereby, this advice improves operational availability

  • PDF

Variability of plant risk due to variable operator allowable time for aggressive cooldown initiation

  • Kim, Man Cheol;Han, Sang Hoon
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1307-1313
    • /
    • 2019
  • Recent analysis results with realistic assumptions provide the variability of operator allowable time for the initiation of aggressive cooldown under small break loss of coolant accident or steam generator tube rupture with total failure of high pressure safety injection. We investigated how plant risk may vary depending on the variability of operators' failure probability of timely initiation of aggressive cooldown. Using a probabilistic safety assessment model of a nuclear power plant, we showed that plant risks had a linear relation with the failure probability of aggressive cooldown and could be reduced by up to 10% as aggressive cooldown is more reliably performed. For individual accident management, we found that core damage potential could be gradually reduced by up to 40.49% and 63.84% after a small break loss of coolant accident or a steam generator tube rupture, respectively. Based on the importance of timely initiation of aggressive cooldown by main control room operators within the success criteria, implications for improvement of emergency operating procedures are discussed. We recommend conducting further detailed analyses of aggressive cooldown, commensurate with its importance in reducing risks in nuclear power plants.

A Study of Analytical Integrity Estimations for the Structure and Rotor System of an Emergency Diesel Generator (비상디젤발전기의 회전체 및 구조물 해석적 건전성 평가에 관한 연구)

  • Kim, Chae-Sil;Choi, Heon-Oh;Jung, Hoon-Hyung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.2
    • /
    • pp.79-86
    • /
    • 2014
  • This paper describes an integrity evaluation method for emergency diesel generator(EDG) and rotor part of EDG. EDG is a very important equipment in the nuclear power plant(NPP). EDG supplies electricity to the safety-related equipments for the safety shut down of NPP in an emergency situation of earthquake. The safety of the rotor part of EDG is also important during seismic impact from earthquake. The finite element modelling of the EDG including rotor part was constructed. The modal analysis of EDG was firstly performed. The first natural frequency was calculated and revealed higher than the cutoff frequency of seismic spectrum. Then the stress analysis was done to compare with the allowable stress. The safety of the rotor part was investigated by the finite element analysis of the rotor and journal bearing interaction to find film thickness and critical speed. The seismic load was applied to rotor part in a manner that the load was a weighted static load. Analysis results showed that the maximum stress was within the range of allowable stress and the film thickness is larger than the permissible minimum thickness, and the critical speed was out of the operating speed. Hence, the structural and dynamic integrity of EDG could be confirmed by the numerical analysis method used in this paper. However, dynamic analysis of a rotating rotor and supporting bearing with the seismic impact needs to be investigated in a more rigorous method since the seismic load to the rotating part complicates the behavior of rotating system.

The Design of a I/O Interface Circuits for the Signal Driver of the Engine Control Relays and the Output Signal Monitoring of Diesel Generator (디젤 발전기 출력 신호의 모니터링 및 엔진제어 릴레이 구동을 위한 입출력 인터페이스 회로 설계)

  • Joo, Jae-hun;Kim, Jin-ae;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.547-550
    • /
    • 2009
  • This paper presents a digital based input/output interface circuit for controlling and monitoring the Diesel Engine Generator for Emergency. In order to monitor and control of the Emergency Diesel Engine Generator, controlling and monitoring circuits need 5 analog input channels, 2 pick-up coil measuring circuits, 10 digital input channels containing Broken Wire Detect function, and 7 relay control signal output channels. This system performs signal processing of input signal taking advantage of simple filter circuit, photo-coupler and comparator circuit at analog input parts, and output signals for main relay is designed acting by double control, so it prevents malfunction completely. And it improves accuracy of speed input signal by applying digital circuit that processes pick-up coil signal.

  • PDF

Mobile Receiver Model for T-DMB Location Automatic Emergency Alert Service (T-DMB 국지적 자동재난경보방송 서비스를 위한 모바일 수신 모델)

  • Kwon, Seong-Geun;Jeon, Hee-Young;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10A
    • /
    • pp.796-806
    • /
    • 2009
  • This paper presents the method of emergency warning system operation based on T-DMB and the design of T-DMB AEAS receiver model. The proposed receiver model compares the geographical location of emergency with the location of DMB transmitting station from T-DMB broadcasting signal and classifies the receiver location into alert region, neighboring region and non-alert region and transmits the emergency alert message according to each region. The geographical location of emergency can be obtained from FIG 5/2 EWS data field for AEAS message and the location of DMB transmitting station can be estimated from either the latitude and the longitude in main identifier and sub identifier in FIG 0/22 data filed for TII(Transmitter Identification Information) or TII distribution database. In our experiment, we implemented the proposed receiver model with display section, storage section, DMB module for receiving broadcasting signal and control section and performed test emergency alert broadcasting using T-DMB signal generator.

T-DMB Automatic Emergency Alerting Service by Estimating the Location of Receiver (단말기 위치 자동 인식을 이용한 T-DMB 자동재난경보서비스)

  • Kwon, Seong-Geun;Lee, Suk-Hwan;Kim, Kang-Wook;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.5
    • /
    • pp.615-623
    • /
    • 2012
  • This paper presents T-DMB AEAS (automatic emergency alerting service) receiver model considering emergency region. The proposed receiver model determines the geographical location of the terminal by analysing the received T-DMB signal and displays the AEAS messages only if the location of terminal is similar to the emergency site. First, to determine the geographical location of the terminal, we extract the TII value from the null symbol of the SC and, based on it, calculate the location of transmitter by analysing FIG 0/22 delivering the TII-related data. The proposed algorithm sets the location of transmitter as that of receiver and displays the emergency message only in the case of the similar region. The experiment was conducted in the test environment of low power T-DMB generator based on the T-DMB AEAS messages.

Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield (일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가)

  • Kim, Seung-Uk;Han, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.895-908
    • /
    • 2018
  • As modern science is developed and advanced, examination and number of times using radiation are increasing daily. General diagnostic X-ray generator is installed on stationary form, But X-ray generator was developed because patient who is in the intensive care unit, operation room, emergency room can not move to general x-ray room. What we examine patient by x-ray generator is certainly necessary, So patient exposure is inevitable. but reducing radiation exposure is highly important matter about radiation technology, guardian, patient in the same hospital room, nurse etc. For this reason, rule regarding safety control of diagnostic x-ray generator revised for radiation worker, patient and protector proclaim that mobile diagnostic x-ray shield must placed in case of examine different location excluding operation room, emergency room, intensive care unit. But, radiogical technologist is having a lot of difficulties to examine with mobile x-ray generator, diagnostic x-ray shield partition, image plate and lead apron. So, when we use x-ray generator, we manufacture shield tools can be attached to the mobile x-ray generator On behalf of x-ray shield partition and conduct analysis and in comparison to part of body and distribution of dose rate and find way to reduce radiation exposure through distribution of dose rate of patient within the radiogical technologist, medical team. Mobile x-ray generator aimed at SHIMADZU inc. R-20, We manufactured equipment for shielding x-ray scattered x-ray by installing shielding wall from side to side based on support beam on the mobile x-ray generator. Shielding wall when moving can be folded and designed to expand when examine. Experiment measured five times in each by an angle for dose rate of eyes, thyroid, breast, abdomen and gonad on exposure condition of upper and lower extremity, chest, abdomen which is examined many times by mobile x-ray generator. We used dosimeter RSM-100 made by IJRAD and measured a horizontal dose rate by body part. The result of an experiment, shielding decreasing rate of the front and the rear showed 77 ~ 98.7%. Therefore using self-production shielding wall reduce scattered x-ray occurrence rate and confirm can decrease exposure dose consequently. Therefore, through this study, reduction result which is used shielding wall of self-production will be a role of shielding optimization and it could be answer about reduction of medical exposure recommended by ICRP 103.