• Title/Summary/Keyword: Emergency evacuation

Search Result 301, Processing Time 0.023 seconds

A Study on Minimum Cabin Crew Requirements for Korean Low Cost Air Carriers

  • Yoo, Kyung-In;Kim, Mun-Kyung
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.33 no.2
    • /
    • pp.291-314
    • /
    • 2018
  • In recent 3 years, Korea's low-cost airlines have expanded their areas of passenger transportation not only to domestic market but also to Japan, China, Southeast Asia and US territory as a total of 6 companies (8 airlines including small air operation business carriers). Currently, three more airlines have filed for air transportation business certification as future low-cost carriers, and this expansion is expected to continue. To cope with the aggressive airline operations of domestic and foreign low-cost carriers and to enhance their competitiveness, each low-cost airline is taking a number of strategies for promoting cabin service. Therefore, the workload of the cabin crew is increased in proportion to the expansion, and the fatigue directly connected with the safety task performance is increased. It is stipulated in the Enforcement Regulations of the Korea Aviation Safety Act that at minimum, one cabin crew is required per 50 passenger seating capacity, and all low cost carriers are boarding only the minimum cabin crew. Sometimes it is impossible for them to sit in a floor level emergency exit for evacuation, which is the main task of the cabin crew, and this can cause confusion among evacuating passengers in the event of an emergency. In addition, if one of the minimum cabin crew becomes incapacitated due to an injury or the like, it will become a serious impediment in performing emergency evacuation duties. Even in the normal situation, since it will be violating the Act prescription on the minimum cabin crew complement, passengers will have to move to another available airline flights, encountering extreme inconvenience. Annex 6 to the Convention on International Civil Aviation specifies international standards for the determination of the minimum number of cabin crew shall be based only on the number of passenger seats or passengers on board for safe and expeditious emergency evacuation. Thereby in order to enhance the safety of the passengers and the crew on board, it is necessary to consider the cabin crew's fatigue that may occur in the various job characteristics (service, safety, security, first aid)and floor level emergency exit seating in calculating the minimum number of cabin crew. And it is also deemed necessary for the government's regulatory body to enhance the cabin safety for passengers and crew when determining the number of minimum cabin crew by reflecting the cabin crew's workload leading to their fatigue and unavailability to be seated in a floor level emergency exit on low cost carriers.

A Study on Emergency Evacuation Route Planning and USN-Based Induction Activities of Correctional Facilities (교정시설의 비상시 피난경로계획 및 USN기반 대피유도활동에 관한 연구)

  • Park, Joo-Hyung;Park, Jong-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.39-46
    • /
    • 2011
  • In correctional facilities with majority of occupants in custody, the safe evacuation guide without getaway accidents should be very important due to complexity in escape paths. Fire causes are various in correctional facilities, for example, arson fire is a major cause in mental treatment facilities, however, old facilities or carelessness of flammable materials consist of fire causes in jail facilities. Both types of correctional facilities are the same in terms of many casualties from the fire cases. The thesis focus on escape paths and evacuation guide plans on the basis of analysis on fire cases and structural vulnerability, and then an electronic unlocking system is concededly installed for safe evacuation of occupants in custody without getaway accidents. Especially, the effect of the electronic unlocking system is going to be analyzed on the basis of RSET (required safe egress time) in order to realize for the occupants to evacuate safely to the front yard in case of emergency. In conclusion, if electronic security allowed system with USN (Ubiquitous Sensor Networks) technology should be installed in multi-storey correctional buildings, it is proposed that the occupants in custody might be a guided safely without getaway trials.

Study on the Horizontally Installed Emergency Exit in Apartment Houses (아파트 하향식 피난구에 대한 고찰)

  • Yeo, In-Hwan;Min, Byung-Yeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05b
    • /
    • pp.91-93
    • /
    • 2010
  • Recently, the regulation about HEE(horizontally installed emergency exit) established at upper 4story in apartment houses was introduced by revising enforcement degree of Building Act. HEE is a facility for egress to lower story through floor breach and ladder system so that it gives a useful evaquation way directly to an individual household in apartment when they failed to evacuate through the entrance door. HEE may offer an opportunity to optain two way egress path ways instead of evacuation space at balcony and through path way to adjacent household in building and that might be an big strengh. but it needs to guarantee for against the crime, getting detailed reviews for being security and supplementation of fire test methods.

  • PDF

Route Optimization for Emergency Evacuation and Response in Disaster Area (재난지역에서의 대피·대응 동시수행을 위한 다중목적 긴급대피경로 최적화)

  • Kang, Changmo;Lee, Jongdal;Song, Jaejin;Jung, Kwangsu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.617-626
    • /
    • 2014
  • Lately, losses and damage from natural disasters have been increasing. Researchers across various fields in Korea are trying to come up with a response plan, but research for evacuation plans is still far from satisfactory. Hence this paper proposes a model that could find an optimized evacuation route for when disasters occur over wide areas. Development of the model used methods including the Dijkstra shortest path algorithm, feasible path method, genetic algorithm, and pareto efficiency. Computations used parallel computing (SPMD) for high performance. In addition, the developed model is applied to a virtual network to check the validity. Finally the adaptability of the model is verified on a real network by computating for Gumi 1stNational Industrial Complex. Computation results proved that this model is valid and applicable by comparison of the fitness values for before optimization and after optimization. This research can contribute to routing for responder vehicles as well as planning for evacuation by objective when disasters occur.

An Indoor Pedestrian Simulation Model Incorporating the Visibility (가시성을 고려한 3차원 실내 보행자 시뮬레이션 모델)

  • Kwak, Su-Yeong;Nam, Hyun-Woo;Jun, Chul-Min
    • Spatial Information Research
    • /
    • v.18 no.5
    • /
    • pp.133-142
    • /
    • 2010
  • Many pedestrian or fire evacuation models have been studied last decades for modeling evacuation behaviors or analysing building structures under emergency situations. However, currently developed models do not consider the differences of visibility of pedestrians by obstacles such as furniture, wall, etc. The visibility of pedestrians is considered one of the important factors that affect the evacuation behavior, leading to making simulation results more realistic. In order to incorporate pedestrian's visibility into evacuation simulation, we should be able to give different walking speeds according to differences of visibility. We improved the existing floor field model based on cellular automata in order to implement the visibility. Using the space syntax theory, we showed how we split the indoor spaces depending on the different visibilities created by different levels of structural depths. Then, we improved the algorithm such that pedestrians have different speeds instead of simultaneous movement to other cells. Also, in order for developing a real time simulation system integrated w ith indoor sensors later, we present a process to build a 3D simulator using a spatial DBMS. The proposed algorithm is tested using a campus building.

Fire Evacuation Simulation Using FFM and FDS (FFM과 FDS를 이용한 화재 대피 시뮬레이션)

  • LEE, Jae-Young;LEE, Min-Hyuck;JUN, Chul-Min
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.2
    • /
    • pp.56-67
    • /
    • 2018
  • In general, fire and evacuation simulators are used independently to diagnose the safety of building. Because this method does not reflect the movement of pedestrians considering fire spread, it is difficult to expect diagnosis of safety with high accuracy. In this study, we propose the simulation method that can describe the movement of pedestrians in the fire emergency. Our method reflects the FDS fire spread data into FFM and explains the situation in which a pedestrian recognize a fire and escapes to a safe route. This study consists of data linkage between FDS and FFM and development of improved FFM. Experiment of the proposed method is progressed using the EgresSIM. Simulation result shows that the number of evacuees on each exit is affected by the presence or absence of fire and it was confirmed that the evacuation time increase and the bottleneck phenomenon deepened by exit.

Study Improvement of the Evacuation Performance in a Double-Skin Structure (이중외피 구조 건축물의 피난성능 개선에 관한 연구)

  • Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.98-107
    • /
    • 2017
  • This study examined an effective way of measuring the evacuation performance in buildings, which are applied to a double skin facade through an evaluation of the escape safety. Buildings with a double skin facade appeared to have a faster combustion expansion speed for the upper floor if a fire occurs. Moreover, a double skin facade is more difficult to escape safely than a general building construction because of the limited design standards. Accordingly, this study suggested virtual modeling including single emergency stairs and alarm systems considering the risk in each structure of buildings. These results showed that box-type double skin, corridor access type, shaft-box type, and multistory facade systems showed a 26.4%, 29.1%, 23.4%, and 26.3% increase in evacuation performance, respectively, as well as securing the safety of occupants.

Study on Trend Analysis of Indoor Evacuation Path Guidance System for Disaster Situation (재난 상황을 고려한 실내 대피경로 안내기술에 대한 동향 분석 및 비교연구)

  • Yun, Younguk;Kim, Nammoon;Choi, Jae-hyuk;Park, Ji-hye;An, Deock-hyeon;Kim, Youngok
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.2
    • /
    • pp.130-135
    • /
    • 2016
  • In this paper, the trend of evacuation path providing or guidance systems for safety on disaster situation is analyzed. For trend analysis, 31 papers of domestic and international, 29 patents of domestic, and the finished 9 national funded projects, which have been performed for recent 15 years are analysed. As the results of analysis, the previous researches were performed in the view of the guidance systems, but there is no study that can be used for peoples in dangerous situation until now. Also it has technical limitations in using indoor positioning technology for peoples. In this paper, therefore, we propose to use the indoor positioning technology for developing a novel evacuation guidance system for peoples in dangerous situation. It can be utilized to develop a novel evacuation guidance system which is considered indoor disaster situations.

A Study on the Development of Fire Alarm System with Evacuation Lighting and Voice Alarm Functions (피난조명 및 음성경보 기능을 내장한 화재경보시스템 개발에 관한 연구)

  • Lee, Gun-Ho;Choi, Su-Gil;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.25-34
    • /
    • 2018
  • This study investigated the development of a fire alarm system with evacuation lighting and voice alarm functions. The performance of a fire detector and system with independently built-in evacuation lighting and voice alarm functions was confirmed for early recognition of fire and to allow visibility of the evacuation route in the event of fire. This new system satisfied model recognition and product testing technological standards with 1.62 lx average illumination, 89.7 dB average sound and 86.1 dB average voice. From additionally testing the evacuation performance of this new system, it was confirmed that the evacuation time decreased by 63.08% to 67.82% under the experimental conditions compared to conventional systems. The new system can minimize fire damage by setting off voice alarms to prevent failure of fire recognition and by flashing emergency lighting to secure the minimum required visibility range for evacuation. Therefore, it is considered that it will be utilized as a fire alarm system with appropriateness and usefulness by considering people with hearing or visual impairment.

A Study on the Optimized Announcement Based Evacuation Guidance Using Haas Effect (선행음 효과를 이용한 최적의 음성피난유도음에 관한 연구)

  • Baek, Eun-Sun;Kim, Sun-Woo;Baek, Geon-Jong;Shin, Hoon;Song, Min-Jeong;Kook, Chan
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.101-106
    • /
    • 2011
  • In case of an emergency such as a fire on a building and there is a need to evacuate the occupant in that building, it is important to have the guidance information effectively delivered to the evacuating occupants to guide them toward a safe direction using audio sensual media. And, it is also very important to prevent the evacuating occupants getting lost or falling astray, away from the direction toward safety. The purpose of this study, in this respect, is to examine the possible application of the precedent sound effect, with which the evacuating occupants may get a sense of the direction where the announcement comes from. With such an effect, an experiment was conducted to measure the extent to which people can hear the preceding and the following sound in terms of the acoustic pressure level changes and delay time changes, with a view to make the optimal evacuation-guidance announcement or sound. The optimal evacuation guidance sound (announcement) per each of the experimental indoors environments were as follows; 1) Regarding the optimal condition for the evacuation guidance announcement sound in the space of a lecture room, the direction of the advanced sound is positively recognized when the follow-up sound has the delaying time of 10 ms~50 ms in comparison with the advanced sound or when there is no difference between the acoustic pressures of the advanced and follow-up sounds or the acoustic pressure of the advanced sound is higher than that of the follow-up sound. 2) Regarding the optimal evacuation guidance announcement sound in the space of a hall, the advanced sound is positively recognized when the follow-up sound has the delaying time of 20 ms~60 ms in comparison with the advanced sound. 3) Regarding the optimal evacuation guidance announcement sound in the space of a gymnasium, the advanced sound is positively recognized when the follow-up sound has the delaying time of 10 ms~40 ms in comparison with the advanced sound or when the sound pressure of the advanced sound has a higher level than or the same level as that of the follow-up sound.