• 제목/요약/키워드: Emergency Shelter

검색결과 39건 처리시간 0.135초

재난재해 시 응급대피공간으로서 학교시설의 디자인 고려요소 -대피거점기능과 교육활동유지기능을 중심으로- (The School Design Factors as Emergency Shelter after Disaster - Focus on the Function for Evacuation Center and Education Maintenance)

  • 김경숙;김민경
    • 교육시설 논문지
    • /
    • 제18권4호
    • /
    • pp.69-77
    • /
    • 2011
  • The purpose of this study is to provide the school planning factors as emergency shelter after disaster. The school functions as the evacuation space areas could be classified into the evacuation center, education maintenance, and dwelling. Among these functions, the scopes of our study are limited to the functions of evacuation center and education maintenance. To carry out this purpose, we were comparative analyzed the shelter space problems of Korea and Japan's survey in the existing literatures. In results of our study, the evacuation center's functions are difficult to depending on the disaster types, such as the earthquake, tornado, and hurricane. On the other hand, the education maintenance functions are difficult to deepening on the victims occupied times in the school as emergency shelters. Based on these findings, the Korea school planning as the emergency shelters are desired to reflect that the evacuation's functions based on the disaster type of the damage from storms, and the education maintenance's functions based on the victim's occupied times in school for their safety.

  • PDF

센서 네트워크를 이용한 대피경로 안내시스템 (The shelter course guidance system using a sensor network)

  • 권정일;노영섭
    • 한국컴퓨터정보학회논문지
    • /
    • 제13권5호
    • /
    • pp.237-246
    • /
    • 2008
  • 대규모 시설물이나 복잡한 시설물에 화재가 발생하였을 때 대피해야 할 사람들에게 화재의 발생 위치와 비상구의 위치에 따른 적절한 대피 안내가 이루어지지 못한다면 대규모의 인명피해를 입을 수 있다. 따라서 화재 방재시스템의 적용 및 인명 피해를 최소화 할 수 있도록 최적의 대피경로를 안내하여 줄 수 있는 대피경로 안내시스템이 필요하다. 본 논문에서는 화재 발생에 따른 인명피해를 줄이기 위한 방법으로 센서 네트워크와 결합한 최적의 대피 경로 안내시스템을 제안하였다. 본 연구의 실험 결과에 따르면 제안된 대피경로 안내시스템은 최적의 대피경로를 구조물 안의 대피인원들에게 화재 상황에 따라 적절하게 실시간으로 안내하여 줌으로써 대피에 소요되는 시간을 줄일 수 있음을 확인 할 수 있었다.

  • PDF

사용자의 거주성을 고려한 이재민 임시주거시설 현황 분석과 계획적 시사점 (Current Status and Implication for the Planning of Emergency Shelter Considering Users' Habitability)

  • 김미경;김은정
    • 한국실내디자인학회논문집
    • /
    • 제25권6호
    • /
    • pp.23-31
    • /
    • 2016
  • The study aims to identify the existing problems and suggests the implication for the planning of emergency shelter in terms of users' habitability. The results of the study show that the concept of shelters for disaster victims need to set up and be distinctively defined as emergency phase and temporary residency phase. In emergency phase, the various types of buildings and facilities should be considered as temporary shelters for disaster victims such as transitional shelters including the public facilities. Based on the results of the critical review, this research proposed an analytic framework emphasizing habitability for disaster victims including vulnerable people such as the disabled, the aged, women and children. The framework is composed of four dimensions: safety, health, convenience and comfortability. The manual guidelines for emergency shelters should reflect the barrier-free design or universal design for various types of disaster victims considering habitability to provide the positive opportunity and future hope for restoration after disaster. This research can be a basis for the planning and application of temporary shelters for disaster victims.

GIS를 활용한 천안지역 대피시설의 현황 및 수용능력 분석 -구도심지역의 2등급 대피시설을 중심으로 (GIS Based Analysis for the Capacity of Emergency Evacuation Shelters in Cheonan - Focused on Class-2 Shelters in Old Downtown)

  • 이희원;성민호
    • 한국산학기술학회논문지
    • /
    • 제14권9호
    • /
    • pp.4572-4579
    • /
    • 2013
  • 최근 북한의 각종 도발로 인하여 유사시 긴급대피시설에 대한 관심이 고조되고 있다. 그러나 북의 도발대비 접경지역의 경우 인구에 비해 278곳의 대피시설이 부족하고, 장기체류가 가능한 2등급 대피시설의 부족은 더욱 심각한 상태이다. 이에 본 연구에서는 우선 천안시 동지역의 모든 대피시설현황을 파악하여 그 수용범위를 가시화하고, 수용가능인원을 분석하였으며, 구도심(성정동, 중앙동, 문성동)지역의 2등급 대피시설에 대하여는 GIS의 버퍼분석을 통한 대피가능범위와 실제 수용가능인원을 산출하여 추가로 필요한 2등급 대피시설의 면적을 도출하였다. 연구결과 구도심지역의 2등급 대피소는 해당지역 인구의 약 56%(30,657명)의 인구를 수용할 수 있는 $25,546m^2$의 대피소 면적이 추가로 필요함을 알 수 있었다.

Evaluation of shelter performance following the 2013 Moore tornado

  • Scott, Pataya L.;Liang, Daan
    • Wind and Structures
    • /
    • 제21권4호
    • /
    • pp.369-381
    • /
    • 2015
  • Moore, Oklahoma was hit by an EF5 tornado on May 20, 2013. The tornado track slightly overlapped with two previous tornadoes that occurred on May 3, 1999 and May 8, 2003 respectively. A research team from Texas Tech University was deployed to investigate the performance of shelters based on observation of their post-storm conditions. Sixty-one shelter units were further documented by size, manufacturer, and date of installation if available. Then they were crossed referenced with the external databases to determine their compliance with design and construction standards by the International Code Council/National Storm Shelter Association and/or criteria from the Federal Emergency Management Agency publications. Wind intensity was estimated for each shelter location using the EF scale. Results showed a marked increase in the number of exterior underground shelters as well as the popularity of a new in-garage floor underground shelter design. All of the units provided protection for their occupants with no loss of life reported. However, one older shelter had a door failure due to neglect of maintenance. Recommendations were made to improve future performance of shelters.

거주성 관점의 미국 이재민 임시대피시설 공간계획 관련 지침분석 (Analysis of the Space Planning Guidance about the Temporary Shelter Emphasizing Habitability for Disaster Victims in U.S.)

  • 김미경;최선미;최유라
    • 한국실내디자인학회논문집
    • /
    • 제26권5호
    • /
    • pp.42-51
    • /
    • 2017
  • The purpose of this study was to analyze the information about the disaster temporary shelter space planning guidance described in the U.S. shelter guidelines in terms of the habitability for disaster victims and to address the implications and potential impacts of its findings for the improvement of the shelter design standards and guidelines in Korea. The researchers reviewed four federal and non-governmental organization shelter field and design guidelines and attributes regarding the shelter space planning were classified in accordance with four habitability categories: Safety, Health, Convenience, and Comfort. Three major findings emerged from this study: 1)A total of 72 items about the shelter space planning were extracted from guidelines, and the majority of items are concerned with dormitory areas and sanitary spaces. Other items were about accessibility, children respite care area, signage, health service areas, food preparation and serving areas, parking and drop-off areas, registration and waiting areas, shelter manager and staff areas, lounge and storage areas, and household pets area. 2)Most of these items are strongly related to the convenience category(66.7%), followed by comfort(40.3%), safety(30.6%), and health(25.0%). 3)The habitability of the disaster temporary shelter can be established with considerations on the needs of disaster victims and vulnerable people, minimum occupancy space per person, separate sanitary spaces for the privacy, safe and convenient access routes to the shelter, and the provision of children areas for safety and comfort. The study findings will contribute to the development of the disaster shelter guidelines in Korea by suggesting shelter space planning indicators related to the habitability for the governmental and non-governmental organizations' immediate and systematic responses to the disaster.

지진대피공간으로써의 공원녹지 적절성 평가지표 연구 (A Study on the Suitability Impact Factors of a Comprehensive Park as an Emergency Shelter for Earthquakes)

  • 차오린썬;강태호
    • 한국조경학회지
    • /
    • 제45권4호
    • /
    • pp.62-70
    • /
    • 2017
  • 2016년 9월 12일 경상북도 경주시역에서 발생한 규모 5.8의 지진은 한국이 더 이상 지진으로부터 안전한 지역이 아님을 전 국민에게 확실하게 인지하게 하였다. 도시 녹지는 특성상 양호한 지진 대피 기능을 지니고 있는 도시 내 중요한 지진 대피 장소이다. 그러나 공원녹지는 지진 대피 적절성에 대한 연구의 부족으로 지진 발생 후 피난 장소로 활용되지 못하고 있는 경우가 많다. 본 연구는 도시 공원이 지진 대피 장소로써의 적절성을 평가하기 위한 지표를 개발하기 위해 델파이 기법을 활용하여 3차에 걸쳐 조사를 실시하였다. 조사 결과에 대한 평균(M), 표준편차(SD), 합의도, 수렴도, 내용타당도 지수(CVR) 등을 분석하여 총 37개 지표 중 10개의 지표들을 기준에 부합하지 않기 때문에 제거하였고, 최종 27개의 지표가 선정되었다. 최종 연구 결과, 공원녹지의 지진 대피 적절성 평가에 대한 안전성과 접근성, 서비스 효과성은 각각 8개, 6개, 13개의 평가지표가 선정되었다.

유동인구를 활용한 대피소 수용 능력 분석 (A Spatial Analysis of Shelter Capacity Using Floating Population)

  • 김미경;강신혜;김상필;손홍규
    • 한국측량학회지
    • /
    • 제34권1호
    • /
    • pp.1-10
    • /
    • 2016
  • 서울은 많은 인구 및 도시 기능이 집중된 거대 도시로, 재난 및 위급상황이 발생하였을 때 긴급하게 대피할 수 있는 장소는 필수적이다. 현재 서울시 대피소의 숫자는 수용능력 면에서 보면 서울시 인구의 두 배 이상을 상회하고 있다. 하지만 서울의 경우, 거주지의 인구분포와 유동인구를 포함한 낮 시간대의 인구분포는 상이하다. 따라서 대피소의 실질적인 수용성을 분석하기 위해서는 수도권 인구 분포의 유동적인 특성을 고려할 필요가 있다. 이에 본 연구에서는 수도권의 유동인구자료를 활용하여 서울시 대피소의 실질적인 접근성 및 수용능력을 분석하고자 하였다. 이를 위해 보행자 도로망을 이용한 네트워크 분석을 통해 대피소의 접근성을 파악하고 거주인구 및 유동인구에 따른 지역적 수용능력의 차이를 분석하였으며, 연구지역 내 대피소의 분포에 따라 취약한 지역과 현재의 대피소 위치 선정에 대한 문제점을 도출할 수 있었다.

원전 사고지역에서 실내대피를 위한 임시대피시설의 거주성 확보방안 (Measures to Secure the Habitability of Temporary Shelter for Shelter in Place in Nuclear Power Plant Accidents)

  • 김정동;은종화
    • 한국재난정보학회 논문집
    • /
    • 제19권3호
    • /
    • pp.582-596
    • /
    • 2023
  • 연구목적: 본 연구는 원전사고 발생 시 임시 대피시설의 안전성을 강화할 수 있는 방안을 연구하였다. 연구방법: 본 연구에서는 과거의 체르노빌, 후쿠시마, 쓰리마일섬(TMI) 원전사고에 대한 사례연구를 활용하였다. 연구결과: 현재의 방사선 비상 대응 계획은 소개에 중점을 두고 있으며, 실내대피 개념은 단순히 주민 대피를 지원하는 수단으로 활용되고 있다. 그러나 사례연구를 통해 INES-5 이상의 사고의 경우, 소개보다 실내대피를 장려하는 것이 사상자 최소화에 효과적임을 확인하였다. 더 나은 실내대피를 보장하기 위해 아파트를 임시 대피소로 활용할 것을 권장하며, 아파트가 방사선 방호 기술을 갖추도록 개선사항을 제안한다. 결론: 더 나은 실내대피를 보장하기 위해 아파트를 임시 대피소로 활용할 것을 권장하며, 차폐, 양압, 밀폐기술을 이용해서 아파트의 성능을 보완하고자 한다.