• 제목/요약/키워드: Emergency Power Generation

검색결과 80건 처리시간 0.026초

가정용 태양광/풍력 Hybrid 발전시스템의 모니터링에 관한 연구 (A Study on Monitoring for based-Photovoltaic/Wind power Hybrid Generation System)

  • 정병영;차인수;임중열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.365-368
    • /
    • 2006
  • The objective of this research is to investigate usage of 3KW photovoltaic-wind power hybrid generation system composed of 500W solar power generator and 400W wind power generator in a parallel circuit. In addition, solar radiation meter and wind monitor have been installed into each generation system to obtain the practical operating data that monitored in monthly, daily and hourly. These data that are independent to weather change and location would provide adequate generation output on average and cope with emergency situation in generation system In conclusion, based on this study, it could be considered for 3KW combined generation system to be gradually propagated to houses and small-size public facilities.

  • PDF

비상전원 기능을 갖는 하이브리드 ESS를 위한 PCS 제어전략 (A PCS Control Strategy for Hybrid ESS with Function of Emergency Power Supply)

  • 김상진;권민호;최세완;백석민;김미성
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.302-311
    • /
    • 2016
  • This paper proposes a hybrid ESS that integrates an energy storage system (ESS) with an uninterruptible power supply (UPS). The hybrid ESS has a demand management and emergency power supply function while increasing the battery utilization of the UPS, which has just been used in a power failure. In addition to the critical load, the proposed system augments the capacity of emergency generation using an additional load, which has voltage and frequency-dependent characteristics to the grid side. The control algorithm of the AC-DC converter and bidirectional DC-DC converter is proposed for demand management and emergency power supply. Furthermore, seamless and autonomous transfer methods to alleviate the transient during mode transfer are proposed. To validate the proposed control scheme, experimental results from a 5 kW prototype are provided.

비상전원 기능을 갖는 하이브리드 에너지저장시스템 표준화 기술 (Hybrid Energy Storage System with Emergency Power Function of Standardization Technology)

  • 홍경진
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.187-192
    • /
    • 2019
  • 수요관리와 정전에 대한 비상전원 기능을 갖춘 하이브리드 전력저장시스템으로 비상발전설비가 필요한 빌딩 및 공장건축 시에 투자비를 최소화하고, 상시 전력비를 절감함으로서 경제성을 확보할 수 있 기술을 개발함으로써 새로운 비즈니스 모델을 제시한다. 평상시에 STS(Static Transfer Switch)를 통해 부하에 계통 전력을 공급하고 PCS는 계통에 병렬로 연계되어 수요관리를 수행한다. EMS는 수요예측을 통한 전력의 효율적 운용을 위해 ESS에 충방전 지령을 PMS(Power Management System)로 하달하고 PMS는 다시 PCS 제어기로 지령을 전달하여 시스템을 운용한다. 정전시에는 STS가 계통으로부터 빠르게 이탈되면서 PCS는 독립 전원이 되어 부하 측에 정전압/정주파수의 전력을 공급할수 있는 구조이다. 따라서 하이브리드 ESS에 대한 실 계통 연계 및 독립 운전 성능 검증을 통한 신뢰성을 확보할수 있고, 저탄소 녹색성장 기술의 효율적 전력망과 연계 운영이 가능하게 함으로써 ESS 연계를 통한 신재생에너지 발전에 의한 불규칙한 전력 품질개선, 피크부하 기여도 제고가 가능하다. 또한 현재 석탄 화력이 담당하고 있는 주파수추종 예비력을 ESS로 대체함에 따라 연료비가 높은 LNG 발전기 가동비용을 절감할 수 있는 기대효과가 있다.

분산발전자원을 활용한 가상발전소 기반 기술의 전력시장 참여 방안에 대한 연구 (A Study on the Participation of Virtual Power Plant Based Technology Utilizing Distributed Generation Resources in Electricity Market)

  • 이윤환
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.94-100
    • /
    • 2016
  • A virtual power plant (VPP) technology is a cluster of distributed generation installations. VPP system is that integrates several types of distributed generation sources, so as to give a reliable overall power supply. Virtual power plant systems play a key role in the smart grids concept and the move towards alternative sources of energy. They ensure improved integration of the renewable energy generation into the grids and the electricity market. VPPs not only deal with the supply side, but also help manage demand and ensure reliability of grid functions through demand response (DR) and other load shifting approaches in real time. In this paper, utilizing a variety of distributed generation resources(such as emergency generator, commercial generator, energy storage device), activation scheme of the virtual power plant technology. In addition, through the analysis of the domestic electricity market, it describes a scheme that can be a virtual power plant to participate in electricity market. It attempts to derive the policy support recommendation in order to obtain the basics to the prepared in position of power generation companies for the commercialization of virtual power plant.

LED터널등 모듈의 폐열활용을 위한 열전소자의 발전 성능 분석 (Analysis of the Thermoelectric Devices' Power Generation Performance for Utilizing the Waste Heat of LED Tunnel Lighting Module)

  • 정지영;허인성;이세일;김명호;유영문
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.1-6
    • /
    • 2015
  • In this paper, we propose the LED(Light-Emitting-Diode) emergency lighting in a tunnel by using the thermoelectric devices. To achieve high generated power, thermoelectric device should be have high Seebeck coefficient and small contact area. Also, we reveal that a moderate heatsink required for high generated power. From the waste heat of LED tunnel lighting module (25W), the generated power was 0.062W by thermoelectric device, and it could illuminate for 1hour after charge the battery of emergency lighting during about 101hours.

광역고장을 고려한 정전 복구 알고리즘 연구 (A Study on the Restoration Algorithm For Multi-Outage Areas in distribution system)

  • 정진수;문현경;임성일;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.381-383
    • /
    • 2004
  • This paper presents for service restoration Abstract -in electric power distribution systems. The aim of the service restoration is an emergency control in distribution system to restore out-of service areas as soon as possible when a fault occurs in distribution system. For this reason, this paper presents a new service restoration strategy for multi-outage areas. Proposed algorithm consists of two methods. One is individual restoration scheme, the other one is integrated restoration scheme. The former determines restoration order of outage areas based on restoration index. If the former method can not generate a feasible restoration plan, the latter would try to find new configuration without overloaded section through tie exchange method.

  • PDF

TSAT을 이용한 우리나라 계통의 저주파수 부하차단 방식 검토 (A Study on Under-Frequency Load Shedding Scheme of Korea Electric Power System using TSAT)

  • 이강완;배주천;조범섭;오화진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.34-37
    • /
    • 2003
  • The frequency of power system will change when the load-generation equilibrium is disturbed. Insufficiency of generation from the imbalance between load and generation decreases the power system frequency. In case of the severe emergency, the under frequency load shedding scheme is applied for the power system defense plan. In this paper, we analyzed the dynamic characteristics of under frequency load shedding using new Transient Security Assessment Tool ; TSAT. We applied the actual UFLS scheme to these studies and considered the possible contingency.

  • PDF

소방 방재설비용 연료전지 발전시스템의 비절연형 고효율 전력변환기 설계 (High Efficiency Power Conversion System of Non Isolated Type Applied in Fuel Cell Generator Used to Fire Prevention Installation)

  • 곽동걸
    • 마이크로전자및패키징학회지
    • /
    • 제13권3호
    • /
    • pp.19-26
    • /
    • 2006
  • 본 논문은 예비 전력공급설비의 일환으로 비상시 소방 방재설비에 적용되는 연료전지 발전시스템에 대해 연구된다. 제안된 시스템은 비상시 상용 전력공급의 차단에 대비하여 소방 방재설비들의 전력공급원으로 이용된다. 연료전지 발전시스템에서 가장 손실이 큰 부분은 전력변환부이다. 또한 전력변환부의 손실은 전력변환을 위해 사용된 전력용 반도체 스위치의 스위칭 손실로 주어진다. 본 논문에서는 이러한 연료전지 발전시스템의 출력을 최대한 활용하기 위하여 부분공진의 기법이 적용된 고효율의 전력변환기가 제안된다. 또한 연료전지 발전시스템에 적용된 고효율 전력변환기는 비절연형으로 설계되고 사용된 제어스위치들은 새로운 소프트 스위칭 회로토폴로지에 의해 무손실로 동작되어 시스템의 효율을 증대시킨다. 다양한 컴퓨터 시뮬레이션과 특성실험을 통해 이론적 해석의 타당성이 입증된다.

  • PDF

비상 발전기를 이용한 유도전동기의 소프트 기동 시스템 (Soft Start System of Induction Motor using Emergency Generator)

  • 황보찬;고재하;이정환;박성미;박성준
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.433-441
    • /
    • 2022
  • In general, in an emergency generator system for an electric facility including an induction motor load, an emergency power generation facility larger than the facility load capacity is built due to the initial starting current of the induction motor. In order to reduce this economic burden, various methods to reduce the inrush current of induction motors are applied to suppress the additional expansion of generators due to the reduction of power generation facilities and the increase in electrical facilities. Among these methods, when a system with a built-in soft start function of an induction motor using an inverter is built, it is the best way to reduce the inrush current of the induction motor to less than the rated current. However, in this case, the installation cost of the inverter to drive the induction motor increases. This paper proposes a soft start method of an induction motor by expanding the frequency and voltage control operation area of an emergency generator. In addition, proposed a speed calculation method based on power factor information, which is essential information for stable soft start of an induction motor, and a method for generating a speed command value of the governor for starting with maximum torque.

비상발전기 보호용 원판형 지락과전류계전기의 고조파영향에 관한 연구 (A Study on the Harmonics Effect of Disc-Type Over Current Ground Relay for Emergency Generator Protection)

  • 김경철;고훈
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.58-62
    • /
    • 2015
  • When an emergency generator is running, it supplies the power for critical loads. Generator protection requires the consideration of many abnormal conditions that may occur with generators include overvoltages and ground faults. Modern day power systems create harmonics within the electrical network that can have an impact upon the associated protective system. This paper focuses on the analysing of the cause and development of a solution for the malfunction of induction disc type overcurrent ground relay by generation of harmonics during emergency generator operation.