• Title/Summary/Keyword: Emergency Operation Mode

Search Result 28, Processing Time 0.029 seconds

무인수상정에서의 원격운용통제 및 자율수준을 고려한 비상모드 알고리즘 (Emergency Mode Algorithm Considering Remote Operation/Control and Autonomous Level of Unmanned Surface Vehicle)

  • 윤종택;김용이;백재웅;임재현;유찬우;김정훈
    • 대한임베디드공학회논문지
    • /
    • 제12권5호
    • /
    • pp.319-330
    • /
    • 2017
  • In remote USV (Unmanned Surface Vehicle) maritime operation, the remote operation and control technic and autonomous control technic is required and the emergency mode algorithm is needed certainly for sailing and accomplishing various surveillance, reconnaissance, and underwater search missions of USV. In this paper, we review the countermeasures in emergency situation of the existing USV system (Barracuda) and propose the emergency mode algorithm considering the operation and control, and autonomous control level for the stable USV operation in case of emergency. We analyzed the autonomous control level in view of the mission complexity and environmental difficulty, and human interface, and verified the performance of the autonomous control level when we apply four emergency mode algorithms. It is expected that more stable and reliable operation and cotrol are possible if the proposed algorithm is applied to the environments requiring the various multi-mission USV sailing and mission achievement.

HILS를 이용한 신재생 에너지원이 포함된 에너지 저장시스템의 운영 시나리오 개발 (Development of Operation Scenarios by HILS for the Energy Storage System Operated with Renewable Energy Source)

  • 신동철;전지환;박성진;이동명
    • 전기학회논문지
    • /
    • 제67권2호
    • /
    • pp.224-232
    • /
    • 2018
  • According to government policy, renewable energy facility such as solar power generation is being implemented for newly constructed buildings. In recent years, the introduction of Energy Storage System (ESS) served as an emergency power for replacing an existing diesel generator has been increasing. Furthermore, in order to expand the efficacy of the ESS operation, operation in combination with renewable energy sources such as solar and wind power generation is increasing. Hence, development of the ESS operation algorithms for emergency mode as well as the peak power cut mode, which is the essential feature of ESS, are necessary. The operational scenarios of ESS need to consider load power requirement and the amount of the power generation by renewable energy sources. For the verification of the developed scenarios, tests under the actual situation are demanded, but there is a difficulty in simulating the emergency operation situation such as system failure in the actual site. Therefore, this paper proposes simulation models for the HILS(Hardware In the Loop Simulation) and operation modes developed through HILS for the ESS operated with renewable energy source under peak power reduction and emergency modes. The paper shows that the ESS operation scenarios developed through HILS work properly at the actual site, and it verifies the effectiveness of the control logic developed by the HILS.

연속적인 운전모드의 전환을 위한 계통연계형 인버터의 간접 전류 제어기법 (Indirect Current Control of Utility Interactive Inverter for Seamless Transfer)

  • 유태식;배영상;김효성;최세완
    • 전력전자학회논문지
    • /
    • 제11권1호
    • /
    • pp.72-78
    • /
    • 2006
  • 분산발전시스템에 비상부하 등의 전용부하가 접속되어 있는 경우, 주전원에 고장이 발생하러라도 비상전용부하에는 지속적인 전력을 공급하기 위하여 의도적인 단독운전을 하게 된다. 기존의 계통연계형 인버터는 주전원에 전력을 주입하기 위하여 평소에 전류제어모드로 운전을 하기 때문에, 의도적인 단독운전 상황이 발생하는 경우 비상부하에 안정된 전압을 공급해 주기 위하여 전압제어모드로 운전을 전환하여야한다. 이러한 운전모드의 전환시 인버터의 출력단 전압에 심각한 과도문제가 발생된다. 본 논문에서는 의도적인 단독운전 발생시 인버터 운전모드 전환에 따른 출력전압의 과도현상을 최소화하기 위한 인버터 토폴로지와 제어알고리즘을 제안한다. 제안된 간접전류제어 알고리즘에 적합한 LCL필터 설계방법과 설계데이터를 제시한다.

리스크정보를 활용한 비상디젤발전기 허용정지시간 연장시 안전성평가 (Safety Assessment for Emergency Diesel Generator(EDG) Allowed Outage Time(AOT) Extension using Risk-informed)

  • 임혁순;김두현
    • 한국안전학회지
    • /
    • 제25권3호
    • /
    • pp.118-122
    • /
    • 2010
  • 원자력발전소의 운전 유연성 증대, 안전성 및 경제성 향상, 정비 부담을 완화하기 위해 비상디젤발전기의 허용정지시간 연장이 요구된다. 확률론적안전성평가(probabilistic safety assessment) 기법으로 현재의 비상디젤발전기의 허용정지 시간을 3일에서 7일, 10일, 14일로 연장시 안전성 영향을 평가하였다. 종합적으로 평가결과, 비상디젤발전기의 허용정지시간 연장시 EDG 점검 또는 정비기간 중 인적실수으로 인한 발전소 불시정지 예방 및 안전성을 향상 시키는 것으로 분석되었다.

무인항공기 체계의 통합검증을 위한 무인항공기 체계통합실험실(UAV SIL) 개발 (Development of Unmanned Aerial Vehicle System Integration Laboratory(UAV SIL) for the Integrated Verification)

  • 심재익;우희채;김상진;정상준
    • 한국군사과학기술학회지
    • /
    • 제27권1호
    • /
    • pp.70-79
    • /
    • 2024
  • This paper describes the results of the development of the the unmanned aerial vehicle system integration laboratory(UAV SIL) for the integrated verification. This UAV SIL is designed to test the robustness of the UAV system including the operational logics and the flight control system behaviors under many abnormal and emergency conditions such as data-link losses, airborne subsystem failures, engine shut down conditions, and ground control station faults. This paper presents how to build the UAV SIL and how to verify the in-development UAV system through the UAV SIL.

Unstable Operation of Francis Pump-Turbine at Runaway: Rigid and Elastic Water Column Oscillation Modes

  • Nicolet, Christophe;Alligne, Sebastien;Kawkabani, Basile;Simond, Jean-Jacques;Avellan, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.324-333
    • /
    • 2009
  • This paper presents a numerical simulation study of the transient behavior of a $2{\times}340MW$ pump-turbine power plant, where the results show an unstable behavior at runaway. First, the modeling of hydraulic components based on equivalent schemes is presented. Then, the 2 pump-turbine test case is presented. The transient behavior of the power plant is simulated for a case of emergency shutdown with servomotor failure on Unit 1. Unstable operation at runaway with a period of 15 seconds is properly simulated using a 1-dimensional approach. The simulation results points out a switch after 200 seconds of the unstable behavior between a period of oscillations initially of 15 seconds to a period of oscillation of 2.16 seconds corresponding to the hydraulic circuit first natural period. The pressure fluctuations related to both the rigid and elastic water column mode are presented for oscillation mode characterization. This phenomenon is described as a switch between a rigid and an elastic water column oscillation mode. The influence of the rotating inertia on the switch phenomenon is investigated through a parametric study.

Research on Line Overload Emergency Control Strategy Based on the Source-Load Synergy Coefficient

  • Ma, Jing;Kang, Wenbo;Thorp, James S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1079-1088
    • /
    • 2018
  • A line overload emergency control strategy based on the source-load synergy coefficient is proposed in this paper. First, the definition of the source-load synergy coefficient is introduced. When line overload is detected, the source-load branch synergy coefficient and source-load distribution synergy coefficient are calculated according to the real-time operation mode of the system. Second, the generator tripping and load shedding control node set is determined according to the source-load branch synergy coefficient. And then, according to the line overload condition, the control quantity of each control node is determined using the Double Fitness Particle Swarm Optimization (DFPSO), with minimum system economic loss as the objective function. Thus load shedding for the overloaded line could be realized. On this basis, in order to guarantee continuous and reliable power supply, on the condition that no new line overload is caused, some of the untripped generators are selected according to the source-load distribution synergy coefficient to increase power output. Thus power supply could be restored to some of the shedded loads, and the economic loss caused by emergency control could be minimized. Simulation tests on the IEEE 10-machine 39-bus system verify the effectiveness and feasibility of the proposed strategy.

서울메트로 PSD 통합관제시스템 구축방안에 대한 연구 (Study on Implementation Scheme for Integrated PSD Control System of Seoul Metro)

  • 김용협;현용섭;류호중;김진수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1551-1559
    • /
    • 2007
  • Seoul Metro has been constructing the screen doors on the platforms to provide safe and comfort environments. The screen doors of each station are configured so that they can be operated in automatic mode in connection with ATC/ATO through the integrated control panel in the station control room and in manual mode through the control panel of the station control room and crew control panel. These systems have been implemented with different data communication protocols between systems, HMI configuration, and so on due to ordering processes, implementation time and diverse suppliers, and manufactured to be operated within single station. Seoul Metro has been planning to implement the integrated control system to secure seamless train operation and safety and to have a fast response system against emergency situations such as PSD failure and fire, by implementing the system that is able to collectively manage, monitor and control the operation status and equipment conditions of PSD on to the integrated control center. This paper has studied a scheme to reduce the budget for the future facility constructions by standardizing the data format for data communication with the integrated station control panel and using the open standard protocols, in order to secure consistency of operation, system expansion and maintenance with unified and standardized control items.

  • PDF

초소형 SAR 위성 S-STEP의 임무 시나리오에 따른 자세 제어 성능 예비 분석 (Preliminary Analysis on Characteristics of Attitude Control based on Operation Scenario of Small SAR Satellite Mission, S-STEP)

  • 이은지;박진한;송성찬;오현웅
    • 항공우주시스템공학회지
    • /
    • 제16권5호
    • /
    • pp.49-56
    • /
    • 2022
  • S-STEP 은 관심 지역의 시한성 긴급 표적 및 군사적 이상 징후를 감시하기 위한 초소형 SAR 위성 임무로, 고도 510 km의 저궤도에 32 대의 위성군을 배치하여 관심 지역에 대해 평균 재방문 주기를 30 분 이하로 달성한다. S-STEP의 임무 운용 모드는 표준 모드, 관측 모드, 통신 모드, 궤도유지 모드 등으로 구분되며, 이에 따라 자세 기동 모드 역시 초기 각속도 안정화, 태양 지향, 목표지점 및 지상국 지향, 추력 방향 유지 등으로 세분화된다. 이 연구에서는 S-STEP 임무 운용 시나리오의 예비 설계 결과와 위성체의 특성을 바탕으로 초기 각속도 안정화 및 태양 지향 모드와 관측 궤도 운용 모드에서의 자세 성능을 분석하였다. 분석 결과, 할당된 시간 이내에 필요한 자세 제어를 완료하여 각 모드에서 요구되는 자세 제어 정확도를 달성함을 확인하였다.

볼밸브를 사용한 송수펌프장에서의 수격현상 (Waterhammer in Transmission Pumping Station with Ball Valve)

  • 김경엽;김점배
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1697-1702
    • /
    • 2004
  • The waterhammer has recently become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. When the pumps are started or stopped for the operation or tripped due to the power failure. the hydraulic transients occur as a result of the sudden change in velocity. In this paper, the field tests on the waterhammer by the startup, stoppage, and power failure of a centrifugal pump were carried out for Yongma transmission pumping station in Seoul. The experimental results were compared with that of the numerical calculations. in which results the procedure of controlled pump normal shut-down and the two-step closing mode of controlling the ball valve for pump emergency stop are proposed to reduce the pressure surge.

  • PDF