• Title/Summary/Keyword: Emergency Monitoring

Search Result 469, Processing Time 0.021 seconds

A Study on Design and Operation Performance of Automatic Fire Detection Equipment (P-type One-class Receiver) by Bidirectional Communication (양방향 통신이 가능한 자동화재탐지설비(P형 1급 수신기)의 설계 및 동작특성에 관한 연구)

  • Lee, Bong-Seob;Kwak, Dong-Kurl;Jung, Do-Young;Cheon, Dong-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.347-353
    • /
    • 2012
  • In this paper, authors will develop the quick and precise remote controller of automatic fire detection equipment (P-type one-class receiver) based on information communication technology (IT). The remote controller detects the fire and disaster in the building automatically and quickly and then activates the facilities to extinguish the fire and disaster, monitoring such situation in a real time through wire-wireless communication network. The proposed remote controller is applied a programmable logic device (PLD) micom. of one-chip type which is small size and lightweight and also has highly sensitive-precise reliabilities. The one-chip type PLD micom. analyzes digital signals from sensors, then activates fire extinguishing facilities for alarm and rapid suppression in a case of fire and disaster. The detected data is also transferred to a remote situation room through wire-wireless network of RS232c and bluetooth communication, and then the situation room sends an emergency alarm signal. The automatic fire detection equipment (AFDE) based on IT will minimize the life and wealth loss while prevents fire and disaster.

Measurement of Arterial Pulse Wave at the Temple Using PZT Piezo Sensor

  • Kil Se Kee;Han Young Hwan;Lee Eung Hyuk;Park Young Bae;Cho Heung Ho;Min Hong Ki;Hong Seung Hong
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.772-775
    • /
    • 2004
  • Generally, arterial pulse waves are measured at the radial arterial of wrist or carotid arterial of neck using a sensor such as pressure sensor, piezoelectric sensor or optic sensor. But in this paper, arterial pulse wave is measured at the temple using PZT piezo sensor which is attached on the temple in form of a hair-band. Arterial Pulse waves are generally measured when a reagent is in a static state. But in this paper, we implemented the arterial pulse wave measurement system, as a previous stage of the arterial pulse wave measurement system for running at outdoors or on a running machine, that measures arterial pulse waves at the temple, which is the least moving part when running. Thorough the continuous study, if the motion artifact when running is possible to be removed, the system will be able to perform monitoring of running men's states and especially emergency signals such as serious pulse waves of an/old and feeble persons and handicapped persons.

  • PDF

Abnormality diagnosis model for nuclear power plants using two-stage gated recurrent units

  • Kim, Jae Min;Lee, Gyumin;Lee, Changyong;Lee, Seung Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.2009-2016
    • /
    • 2020
  • A nuclear power plant is a large complex system with tens of thousands of components. To ensure plant safety, the early and accurate diagnosis of abnormal situations is an important factor. To prevent misdiagnosis, operating procedures provide the anticipated symptoms of abnormal situations. While the more severe emergency situations total less than ten cases and can be diagnosed by dozens of key plant parameters, abnormal situations on the other hand include hundreds of cases and a multitude of parameters that should be considered for diagnosis. The tasks required of operators to select the appropriate operating procedure by monitoring large amounts of information within a limited amount of time can burden operators. This paper aims to develop a system that can, in a short time and with high accuracy, select the appropriate operating procedure and sub-procedure in an abnormal situation. Correspondingly, the proposed model has two levels of prediction to determine the procedure level and the detailed cause of an event. Simulations were conducted to evaluate the developed model, with results demonstrating high levels of performance. The model is expected to reduce the workload of operators in abnormal situations by providing the appropriate procedure to ultimately improve plant safety.

Acute Coronary Syndrome In Acute Carbamate Ingestion (급성 카바메이트 중독후 발생한 급성 관상동맥증후군)

  • Choi, Dai-Hai
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.5 no.1
    • /
    • pp.74-78
    • /
    • 2007
  • The carbamates are a group of insecticides derived from carbamic acid, with a broad spectrum of uses as agricultural and household garden insecticides. Carbamate insecticides are reversible cholinesterase inhibitors. Their inhibitory action is mediated by reversible carbamylation of acetylcholine, as with the organophosphate insecticides. Carbamates are absorbed by the body through multiple routes, including inhalation, ingestion, and dermal absorption. Although poisoning can result from occupational exposure or accidental ingestion, in most cases there is suicidal intent. This is particularly true in developing countries, where the highest incidence of morbidity and mortality from this cause occurs. Cardiac complications often accompany poisoning by carbamate compounds, which may be serious and often fatal. The extent, frequency, and pathogenesis of cardiac toxicity from carbamate compounds has not been clearly defined. Possible mechanismsinclude sympathetic and parasymphatetic overactivity, hypoxemia, acidosis, electrolyte derangements, and a direct toxic effect of the compounds on the myocardium. Patients with carbamate poisoning should immediately be transferred to an intensive or coronary care unit where appropriate monitoring and resuscitative facilities are available. We here report a case of acute coronary syndrome resulting from acute carbamate ingestionthat resulted in a healthy discharge.

  • PDF

Drone Based Sensor Network Scenario for the Efficient Pedestrian's EEG Signal Transmission (효율적인 보행자의 EEG 신호 전송을 위한 드론기반 센서네트워크 시나리오)

  • Jo, Jun-Mo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.9
    • /
    • pp.923-928
    • /
    • 2016
  • The various technologies related to the monitoring human health in real-time for the emergency situations are developing these days. Mostly the human pulse is used for measuring as the vital signs so far, but the EEG became a major research trend now. However, there are some problems measuring and sending EEG signals of all the people walking down the street to the dedicated server. Especially, there are some restrictions for collecting and sending EEG signals in 2-dimensional space in real-time. Therefore, I suggests an efficient network model using 3-dimensional space of drones to avoid the restrictions. The models are designed, simulated, and evaluated with the Opnet simulator.

Comprehensive Crisis Management System of Operational Continuity Management (운영연속성관리(OCM)관점에서 위기관리통합시스템 구축)

  • Kang, Heau-Jo
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.1
    • /
    • pp.127-133
    • /
    • 2010
  • The process for establishment of Operational Continuity Management Plan is organized repeatedly of Business Risk Assessment, Crisis Analysis, Business Impact Analysis, Establishing Business Recovery Strategies, Detailed Planning, Plan Execution, Test and Maintenance(Including Monitoring). Therefore, in this paper in response to global environmental change and the construction and operation of social security systems to maximize operational continuity management, crisis management and crisis management systems, building integrated systems for building technology in general and operational continuity management within an organization to understand developed to provide a framework for implementing operational continuity management in terms of crisis management has proposed to build an integrated system.

Realtime Digital Monitoring and Controller Development for Power Systems (전력시스템의 실시간 디지털 중앙감시 및 제어장치 개발)

  • Jong-Dug Cho;Sun-Hag Hong
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.12
    • /
    • pp.1517-1522
    • /
    • 2001
  • In this paper, We propose digital protective relay which monitors the status of distribution line and controls power apparatus with real time operation. Digital protective relay improves the performance of basic functions which are measurement, display and communication. The Int one we consider is that the protective device has the standard method for protecting the distribution systems which are circuit brakers, switch and emergency generators. These are Protected by analog type Protective relay and devices. The security requirements should be activated within a few seconds, and with real time operation. The second one is an efficient method for adapting the one chip micro-processor(PIC16F84) which is enable to digital control system. The proposed methods are implemented with experimental results and have an high fidelity characteristics in local experiment tests.

  • PDF

Web based anticancer drug management system using ubiquitous sensor network and RFID (USN과 RFID를 이용한 웹 기반 항암제 관리 시스템)

  • Yoo, Sun-K.;Kim, Soo-Jung;Park, Jung-Jin;Kim, Dong-Keun;Bae, Ha-Su;Chang, Byung-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.229-235
    • /
    • 2008
  • In order to monitor the anticancer drug in stable conditions, the Web based anticancer drug management system and alarm services were constructed and assessed in this study. Anticancer drug should be exact to the correct patient in the right environment. To overcome the restriction of existing equipment that only monitors fragmentarily, temperature and humidity were continuously monitored to maintain stable environments using sensor networks and RFID for the monitoring and management of anticancer drug. Construction drug identification and the effect of normal air outside the anticancer dispensary with obstacles were evaluated in working hour. Pre-installed control system in the dispensary could be alternated with auto sensing and alarming. We expected that the efficiency of anticancer drug management and the reliability of drug medication by handwork would be increase accordingly.

Estimation of Chest Compression Depth using two Accelerometers during CPR (심폐소생술에서 두 개의 가속도 센서를 활용한 흉부 압박 깊이 추정)

  • Song, Yeong-Tak;Oh, Jae-Hoon;Suh, Young-Soo;Chee, Young-Joon
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.407-411
    • /
    • 2010
  • During the cardiopulmonary resuscitation (CPR), the correct chest compression depth and period are very important to increase the resuscitation possibility. For the feedback of chest compression depth, the depth monitoring device based on the accelerometer is developed and widely used. But this method tends to overestimate the compression depth on the bed. To overcome this limitation, the chest compression depth estimation method using two accelerometers is suggested With the additional accelerometer between the patient and mattress on the bed, the compression of the mattress is also measured and it is used to compensate the overestimation error. The experimental results show that the single accelerometer estimates as 61.4mm for the actual compression depth of 43.6mm on the mattress. The depth estimation with the dual accelerometer was 44.6mm which is close to the actual depth. With the automatic zeroing in every single compression, the integration error for the depth can be reduced. The dual accelerometer method is effective to increase the accuracy of the chest compression depth estimation.

Accidental Vertebral Artery Cannulation as a Complication of the Central Venous Catherization (우발적인 척추동맥으로의 중심정맥 카테터의 삽관)

  • Jeong, Ju Ho
    • Journal of Trauma and Injury
    • /
    • v.27 no.2
    • /
    • pp.33-37
    • /
    • 2014
  • Central venous catheterization through a subclavian approach is indicated for some special purposes but it may cause many complications such as infection, bleeding, pneumothorax, thrombosis, air embolization, arrhythmia, myocardial perforation, and nerve injury. A case involving a mistaken central venous catheterization into the right vertebral artery through the subclavian artery is presented. A 33-year-old man who had deteriorated mentality after head injury underwent an emergency craniotomy for acute epidural hematomas on the right frontal and temporal convexities. His mentality improved rapidly, but he complained of continuous severe pain in the right posterior neck even though he had no previous symptom or past medical history of such pain. Three-dimensional cervical spine computed tomography (3D-CT) was performed first to rule out unconfirmed cervical injuries and it revealed a linear radiopaque material intrathoracically from the level of the 1st rib up to the level of C6 in the right vertebral foramen. An additional neck CT was performed, and the subclavian catheter was indwelling in the right vertebral artery through right subclavian artery. For the purpose of proper fluid infusion and central venous pressure monitoring, the subclavian vein catheterization had been performed in the operation room after general anesthesia induction before the craniotomy. Sufficient anatomical consideration and prudence is essential because inadvertent arterial cannulation at a non-compressible site is a highly risky iatrogenic complication of central venous line placement.