• Title/Summary/Keyword: Emergency Medical Technology

Search Result 790, Processing Time 0.024 seconds

Comparison of Educational Effectiveness Between Instructor-Centered Learning and Video Self-Instruction about Automatic External Defibrillator for High School Girls (여고생의 자동제세동기에 대한 강사중심학습과 영상자가학습과의 교육효과 비교)

  • Park, Sang-Sub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1732-1739
    • /
    • 2011
  • This study aims to make a comparison of educational effectiveness between instructor-centered learning and video self-instruction(VSI) about automatic external defibrillator(AED) for high school girls in order to help select an effective teaching method concerning AED. A total of 59 high school girls (29 for the experimental group, 30 for the control group) in J Province participated in this study from July 7 to 14, 2010. The analysis was carried out by using an SPSS WIN 12.0 Version program. After the AED instruction, the knowledge increased more in the experimental group (1.72) than that in the control group (1.60); self-confidence increased more in the experimental group (1.58) than that in the control group (1.46); and accuracy of technical performance increased more in the control group (5.46) than that in the experimental group (4.20). The experimental group (5.68) was more satisfied with AED instruction than the control group (4.95). Since video self-instruction proved to be more educationally effective than instructor-centered learning in most areas, it is necessary to apply video self-instruction to AED instruction in the future. However, further researches are necessary to see if video self-instruction is effective.

A Study on the Diagnosis of Urinary Stone Location by Abdominal Positioning Variations (요로결석 위치 진단에 대한 복부자세 변화에 따른 연구)

  • Kim, Dong-Jin;Chae, Jong-Sang;Yoo, Chae-Min;Lee, Bae-Won
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.7-12
    • /
    • 2018
  • Patients who visit the emergency room with urinary stones have difficulty lying down in a supine position due to severe pain when performing the KUB test. The purpose of this study was to find methods to reduce the patients' pain and image distortion, and obtain medical images with high diagnostic values. After checking the standard classification of disease and cause of death, the target group consisted of 121 patients who had clearly distinguished stones from computed tomography. Patients with stones in the ureteralvesical junction were excluded. Qualitative image evaluation was performed by confirming the location of the stone in the computed tomography images. and evaluated the rate of visual discrimination of stones possible through KUB and abdominal plain X-ray. Quantitative image evaluation was performed on the KUB, abdominal plain X-ray images. The transverse process of the first lumbar vertebrae served as the standard point, and the length from this point to the lower part of the stone was measured. Results from looking at the rate of visual discrimination of stones possible through KUB and abdominal plain X-ray showed: 94 patients (77.6%) for KUB images and 91 patients (75.2%) for computed tomography images. The standard deviation for KUB and abdominal X-ray was 3 (2.4%). Comparing and analyzing the location from KUB images and abdominal plain X-ray images, the stone position was 10.1 mm in the kidney, 10.5 mm in the ureteropelvic junction, and 9.7 mm in the ureters. It was shown that the stone moved 10 mm on average with significant statistical difference (P<0.05). In cases where the pain is so severe that it is impossible to perform the test in the supine position, an alternative may be to check the stone position by performing a modified KUB test by having the patient stand in a vertical position. In the future, this will provide convenience to both the examiner and the patient when performing the examination, and it will contribute with its reproducibility.

Bioavailability and Anti-inflammatory Effect of Fermented Red Ginseng in BALB/c Mouse (BALB/c 마우스에서 발효 홍삼 Ginsenoside의 생체이용율과 항염효과)

  • Lee, Eun Kyu;Bae, Chu Hyun;Kim, Yu Jin;Park, Soo-Dong;Shim, Jae-Jung;Yu, Youngbob;Lee, Jung-Lyoul
    • Korean Journal of Plant Resources
    • /
    • v.34 no.5
    • /
    • pp.433-442
    • /
    • 2021
  • The fermented red ginseng by microorganism is known to increase pharmacological activity in vivo. To evaluate the bioavailablity of red ginseng fermented by probiotics, we conducted the pharmacokinetic study of ginsenoside Rb1, Rd and total ginsenosides (TG, ginsenosides Rb1 + Rd + Rg1 + F2 + Rg3 + compound K) in BALB/C mice. The AUC value of ginsenoside Rb1 in mice serum administered with 600mg/kg drugs showed 21.93 ± 14.68 ng·h/mL (RGw, water extract), 275.211 ± 110.04 ng·h/mL (RGe, 50% ethanol extract) and 404.91 ± 162.57 ng·h/mL (fRGe, fermented red ginseng extract). Analysis of ginsenoside Rd also showed a higher ACU value in fRGe than in RGw or RGe. And the AUC value of total ginsenosides in mice serum treated with 600 mg/kg were observed 42.12 ± 23.44 ng·h/mL (RGw), 321.44 ± 133.5 ng·h/mL (RGe) and 537.33 ± 229.01 ng·h/mL (fRGe), respectively. Cmax value of ginsenoside Rb1 in mice administered with 600mg/kg were observed 3.67 ± 3.34 ng/mL (RGw), 23.27 ± 8.81 ng/mL (RGe) and 25.52 ± 7.29 ng/mL (fRGe). These results can be considered that the fermented red ginseng has more bioavailability than that of unfermented red ginseng. In quantitative analysis of the inflammation-related cytokines IL-1β and TNF, no significant difference was found between the fermented red ginseng (fRGe) and the red ginseng (RGe).

Development of an Equine Antitoxin by Immunizing the Halla Horse with the Receptor-Binding Domain of Botulinum Neurotoxin Type A1

  • Kim, Na Young;Park, Kyung-eui;Lee, Yong Jin;Kim, Yeong Mun;Hong, Sung Hyun;Son, Won Rak;Hong, Sungyoul;Lee, Saehyung;Ahn, Hye Bin;Yang, Jaehyuk;Seo, Jong-pil;Lim, Yoon-Kyu;Yu, Chi Ho;Hur, Gyeung Haeng;Jeong, Seong Tae;Lee, Hun Seok;Song, Kyoung;Kang, Tae Jin;Shin, Young Kee;Choi, Joon-Seok;Choi, Jun Young
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.7
    • /
    • pp.1165-1176
    • /
    • 2019
  • Botulinum neurotoxins (BoNTs), produced by Clostridium botulinum, are the most toxic substances known. However, the number of currently approved medical countermeasures for these toxins is very limited. Therefore, studies on therapeutic antitoxins are essential to prepare for toxin-related emergencies. Currently, more than 10,000 Halla horses, a crossbreed between the native Jeju and Thoroughbred horses, are being raised in Jeju Island of Korea. They can be used for equine antitoxin experiments and production of hyperimmune serum against BoNT/A1. Instead of the inactivated BoNT/A1 toxoid, Halla horse was immunized with the receptor-binding domain present in the C-terminus of heavy chain of BoNT/A1 (BoNT/A1-HCR) expressed in Escherichia coli. The anti-BoNT/A1-HCR antibody titer increased rapidly by week 4, and this level was maintained for several weeks after boosting immunization. Notably, $20{\mu}l$ of the week-24 BoNT/A1-HCR(-immunized) equine serum showed an in vitro neutralizing activity of over 8 international units (IU) of a reference equine antitoxin. Furthermore, $20{\mu}l$ of equine serum and $100{\mu}g$ of purified equine $F(ab^{\prime})_2$ showed 100% neutralization of 10,000 $LD_{50}$ in vivo. The results of this study shall contribute towards optimizing antitoxin production for BoNT/A1, which is essential for emergency preparedness and response.

A Study on the Usefulness of Copper Filters Made with 3D Printers in Longbone Examination Using Long Length Detector (장골 검출기를 이용한 장골 검사에서 3D 프린터로 제작한 구리 필터의 유용성 연구)

  • Kim, Woo-Young;Seo, Hyun-Soo;Han, Bong-Ju;Yoon, Myeong-Seong;Lee, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.607-613
    • /
    • 2021
  • Long-bone examination is mainly used for inspection of the lower extremities. Recently, a long length detector (FXRD-1751S, VIEWORKS, Korea) with three digital detectors attached has been developed. High energy X-rays are used because pelvic areas require high image quality. In this case, X-rays are transmitted a lot in thin areas such as an ankle, and it is not suitable for diagnosing an image. Therefore, this study use copper filters made with 3D printers to increase image quality in the Long-bone inspection. A copper filter was manufactured in consideration of the overall thickness of the lower part. The experiment was conducted in anterior-posterior (AP) and lateral (LAT) positions, depending on the presence or absence of the filter. 5x5 pixels of region of interest (ROI) were selected from the pelvis, knee, and ankle areas. X-rays were irradiated under the conditions of 70 kVp and 40 mAs for AP, 80 kVp, and 63 mAs for lat when without filters, 90 kVp and 80 mAs for AP, 90 kVp and 100 mAs for lat when with filters. signal to noise ratio(SNR) ratio and contrast to noise (CNR) values were measured 1106.38, 14.34 before applying the filter and 1189.32, 70.43 after the filter. For the knee area, 650.44, 97.61 before applying the filter, and 1013.17, 444.24 after applying the filter. For the ankle area, 206.65, 23.68 before applying the filter and 993.50, 136.11 after applying the filter. In the Long-bone examination, SNR and CNR were greatly measured when the filter was applied, confirmed the availability of using the copper additional filter.

Evaluation on the Accuracy of Vaccination Card for National Immunization Program in a 2005 Population-Based Survey in Nonsan, Korea (일개 도농복합시 영유아 예방접종 수첩의 정확도 평가)

  • Lee, Moo-Sik;Kim, Jee-Hee;Kim, Kwang-Hwan;Hong, Jee-Young;Lee, Jin-Yong;Kim, Keon-Yeop
    • Journal of agricultural medicine and community health
    • /
    • v.36 no.2
    • /
    • pp.113-119
    • /
    • 2011
  • The aims of this study were to survey, evaluate the accuracy of personal immunization record of vaccination card, and to establish the applicability of personal immunization record for presuming population based immunization rate and evaluation method. In 2005, a population-based survey of 12-35 months old children was carried out in Nonsan, Korea. We conducted household survey and provider check using questionnaire and checklist to obtain data on immunization status for children. Total 11 vaccinations were checked in vaccination card such as BCG, hepatitis b, polio, chickenpox vaccine. For estimating accuracy of immunization status and dates of immunization, we estimated correspondence rate between data from personal vaccination card and data from medical records and immunization registry data. Accuracy of the child's vaccination card by type of National Immunization Program vaccine in whole medical institutions were from 41.8% to 83.2%. Accuracy for the date of vaccination of vaccination card in National Immunization Programme vaccine were from 55.3% to 89.7%. In spite of this study limitations, this study verified the validity of vaccination record of vaccination card substantially, but suggests more efforts to reassure the validity of vaccination card.

MR T2 Map Technique: How to Assess Changes in Cartilage of Patients with Osteoarthritis of the Knee (MR T2 Map 기법을 이용한 슬관절염 환자의 연골 변화 평가)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.298-307
    • /
    • 2009
  • By using the MR T2 map technique, this study intends, first, to measure the change of T2 values of cartilage between healthy people and patients with osteoarthritis and, second, to assess the form and the damage of cartilage in the knee-joint, through which this study would consider the utility of the T2 map technique. Thirty healthy people were selected based on their clinical history and current status and another thirty patients with osteoarthritis of the knee who were screened by simple X-ray from November 2007 to December 2008 were selected. Their T2 Spin Echo (SE hereafter) images for the cartilage of the knee joint were collected by using the T2 SE sequence, one of the multi-echo methods (TR: 1,000 ms; TE values: 6.5, 13, 19.5, 26, 32.5. 40, 45.5, 52). Based on these images, the changes in the signal intensity (SI hereafter) for each section of the cartilage of the knee joint were measured, which yielded average values of T2 through the Origin 7.0 Professional (Northampton, MA 01060 USA). With these T2s, the independent samples T-test was performed by SPSS Window version 12.0 to run the quantitative analysis and to test the statistical significance between the healthy group and the patient group. Closely looking at T2 values for each anterior and lateral articular cartilage of the sagittal plane and the coronal plane, in the sagittal plane, the average T2 of the femoral cartilage in the patient group with arthritis of the knee ($42.22{\pm}2.91$) was higher than the average T2 of the healthy group ($36.26{\pm}5.01$). Also, the average T2 of the tibial cartilage in the patient group ($43.83{\pm}1.43$) was higher than the average T2 in the healthy group ($36.45{\pm}3.15$). In the case of the coronal plane, the average T2 of the medial femoral cartilage in the patient group ($45.65{\pm}7.10$) was higher than the healthy group ($36.49{\pm}8.41$) and so did the average T2 of the anterior tibial cartilage (i.e., $44.46{\pm}3.44$ for the patient group vs. $37.61{\pm}1.97$ for the healthy group). As for the lateral femoral cartilage in the coronal plane, the patient group displayed the higher T2 ($43.41{\pm}4.99$) than the healthy group did ($37.64{\pm}4.02$) and this tendency was similar in the lateral tibial cartilage (i.e., $43.78{\pm}8.08$ for the patient group vs. $36.62{\pm}7.81$ for the healthy group). Along with the morphological MR imaging technique previously used, the T2 map technique seems to help patients with cartilage problems, in particular, those with the arthritis of the knee for early diagnosis by quantitatively analyzing the structural and functional changes of the cartilage.

  • PDF

SNR and ADC Changes at Increasing b Values among Patients with Lumbar Vertebral Compression Fracture on 1.5T MR Diffusion Weighted Images (1.5T MR 기기를 이용한 확산강조영상에서 b Value의 증가에 따른 요추압박골절 환자의 신호대 잡음비와 현성 확산 계수의 변화)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.52-59
    • /
    • 2010
  • To examine among patients with vertebral compression fracture the extent to which signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values at the lumbar vertebral compression fracture site vary on diffusion-weighted MR images according to varying b values on the 1.5T MR device. Diffusion-weighted MR images of 30 patients with compression fracture due to chronic osteoporosis who underwent vertebral MRI from Jan. 2008 to Nov. 2009 were respectively obtained using a 1.5-T MR scanner with the b values increased from 400, 600, 800, 1,000 to $1,200\;s/mm^2$. For diffusion-weighted MR images with different b values, the signal-to-noise ratio (SNR) was assessed at three sites: the site of compression fracture of the lumbar vertebral body at L1 to L5, and both the upper and lower discs of the said fracture site, while for ADC map images with different b values, the SNR and ADC were respectively assessed at those three sites. As a quantitative analysis, diffusion-weighted MR images and ADC map images with b value of $400\;s/mm^2$ (the base b values) were respectively compared with the corresponding images with each different b value. As far as qualitative analysis is concerned, for both diffusion-weighted MR and ADC map images with b value of $400\;s/mm^2$, the extent to which signal intensity values obtained at the site of compression fracture of the lumbar vertebral body at L1 to L5 vary according to the increasing b values were examined. The quantitative analysis found that for both diffusion-weighted MR and ADC map images, as the b values increased, the SNR were relatively lowered at all the three sites, compared to the base b value. Also, it was found that as the b values increased, ADC valueswere relatively lowered at all the three sites on ADC map images. On the other hand, the qualitative analysis found that as the b values increased to more than $400\;s/mm^2$, the signal intensity gradually decreased at all the sites, while at the levels of more than $1,000\;s/mm^2$, severe image noises appeared at all of the three sites. In addition, higher signal intensity was found at the site of compression fracture of the lumbar vertebral body than at the discs. Findings showed that with the b value being increased, both the signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values gradually decreased at all the sites of the lumbar vertebral compression fracture and both the upper and lower discs of the fracture site, suggesting that there is a possibility of a wider range of applications to assessment of various vertebral pathologies by utilizing multi b values in the diffusion-weighted MRI examination.

Aspect of the chief of state guard EMP (Electro Magnetic Pulse) protection system for the consideration (국가원수 경호적 측면에서의 EMP(Electro Magnetic Pulse) 방호 시스템에 대한 고찰)

  • Jung, Joo-Sub
    • Korean Security Journal
    • /
    • no.41
    • /
    • pp.37-66
    • /
    • 2014
  • In recent years, with the development of computers and electronics, electronics and communication technology in a growing and each part is dependent on the cross-referencing makes all electronic equipment is obsolete due to direct or indirect damage EMP. Korea and the impending standoff North Korea has a considerable level of technologies related to the EMP, EMP weapons you already have or in a few years, the development of EMP weapons will complete. North Korea launched a long-range missile and conducted a nuclear test on several occasions immediately after, when I saw the high-altitude nuclear blackmail has been strengthening the outright offensive nuclear EMP attacks at any time and practical significance for the EMP will need offensive skills would improve. At this point you can predict the damage situation of Korea's security reality that satisfy the need, more than anything else to build a protective system of the EMP. The scale of the damage that unforeseen but significant military damage and socio-economic damage and fatalities when I looked into the situation which started out as a satellite communications systems and equipment to attack military and security systems and transportation, finance, national emergency system, such as the damage elsewhere. In General, there is no direct casualties reported, but EMP medical devices that rely on lethal damage to people who can show up. In addition, the State power system failure due to a power supply interruption would not have thought the damage would bring State highly dependent on domestic power generation of nuclear plants is a serious nuclear power plant accident in the event of a blackout phenomenon can lead to the plant's internal problems should see a forecast. First of all, a special expert Committee of the EMP, the demand for protective facilities and equipment and conduct an investigation, he takes fits into your budget is under strict criteria by configuring the contractors should be sifting through. He then created the Agency for verification of performance EMP protection after you have verified the performance of maintenance, maintenance, safety and security management, design and construction company organized and systematic process Guard facilities or secret communications equipment and perfect for the EMP, such as protective equipment maneuver system should take.

  • PDF

Elementary School Children′s Lifestyle (학령기 아동의 생활양식)

  • Kim Shin-Jeong;Lee Jeong-Eun;Ahn Hye-Young;Baek Sung-Sook;Yun Hyo-Young;Jeong Sun-Young;Harm Young-Og
    • Child Health Nursing Research
    • /
    • v.8 no.1
    • /
    • pp.32-43
    • /
    • 2002
  • The purpose of this study was to provide basic data on elementary school children's lifestyle and to contribute to developing on the health education program in elementary schools. The subjects were 1,412 children in 4 elementary schools in Gangwon-Do and Chonrabuk-Do area. Data collection was done from September to November 2001 by questionnaire and school health documents. The questionnaire corrected for the purpose of this study which had been developed by Bronson School of Nursing(1991), 'Lifestyle Questionnaire for School-age Children'. The questionnaire consists of 3 categories; 'Activities that promote health', 'Injury prevention', 'Feeling'. Cronbach coefficient alpha for the 29 items was .68. The data analyzed to obtain frequency, mean, percentage, t-test, ANOVA and Pearson correlation coefficient by SPSS Win program. The results of this study were as follows. 1. Females(50.2%) of gender, 6th grade(24.2%) of grade, nuclear family(82.0%) of family type, beyond college graduate(54.5%) of father's school career, under high school graduate(58.1%) of mother's school career, first of birth order(47.1%) were majority. Mean of father's age was 41.2 and mother's age was 38.1. 2. The mean of lifestyle was 66.4, feeling was 73.3, activities that promote health was 60.3 and injury prevention was 64.0. The highest degree of activities that promote health was 「I eat fruits」and injury prevention was 「I look both ways when crossing streets」and feeling was 「I enjoy my family」. The lowest degree of activities that promote health was 「I visit the dentist every tear」 and injury prevention was 「I wear a helmet when I go on bike trips」 and feeling was 「I think it is okay to cry」. 3. There were significant differences in lifestyle of gender(t=4.309, p=.000), grade(F=6.299, p=.000), father's age(t=2.534, p=.011), father's education(t=-4.933, p=.000), mother's education(t=-3.360, p=.001), birth order (t=5.363, p=.000). There were significant differences in activities that promote health of gender(t=-2.462, P=.014), grade(F=4.893, p=.000), father's education(t=-4.480, p=.000), birth order(t=4.343, p=.000), in injury prevention of gender(t=-4.452, p=.000), grade(F=8.636, p=.000), father's age(t=3.386, p=.001), mother's age(t=2.059, p=.040), father's education(t=-6.051, p=.000), mother's education(t=-5.173, p=.000), birth order(t=4.417, p=.000) and in feeling of gender (t=-3.285, p=.001), grade(F=7.526, p=.000), mother's age(t=-3.268, p=.001). 4. Activities that promote health was positively correlated with injury prevention(r=.432, p=.000), feeling(r=.210, p=.000), lifestyle (r=.785, p=.000). Injury prevention was positively correlated with feeling(r=.256, p=.000), lifestyle(r=.854, p=.000) also feeling was positively correlated with lifestyle(r=.504, p=.000). These findings suggest the need to develop nursing strategy to promote elementary school children's health. Because helmet use score in injury prevention marked the lowest score, it is necessary to encourage helmet use when planning injury prevention and health promotion.

  • PDF