• Title/Summary/Keyword: Emergency Bed

Search Result 61, Processing Time 0.022 seconds

Development of the Upper Wear Fixation Device for Chest AP X-ray Imaging on the Emergency Stretcher Bed (응급실 침대 위 흉부전후방향 엑스선 검사를 위한 상의고정장치 개발)

  • Lim, Woo-Taek;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.205-211
    • /
    • 2022
  • This study aimed to provide basic data for 3D printing in the medical health field by developing upper wear fixation device (UWFD), an auxiliary device for shortening chest AP examination time on emergency room beds and non-contact with patients. The standard of hooks was modeled according to the bed frame using the Autodesk Fusion 360. It was printed with Form2 (Formlabs, Somerville, MA, USA), as SLA (stereo lithography apparatus) method, and was washed and hardened using Form Wash and Form Cure. The completed UWFD conducted an online survey on 4 items of stability, convenience, availability, preference and general characteristics. The total stability average was 3.93±0.80, the total convenience average was 3.93±0.68, the total availability average was 4.01±0.89, and the total preference average was 3.80±1.08. This study was significant in suggesting improvements in the general X-ray examination process in the emergency room by designing and making aids to easily fixing the patient's top to the frame of the emergency bed while meeting promptness and non-contact with the patient.

The Impact on the accuracy of the basic CPR according to position and foot-board height of the basic CPR provider (심폐소생술 제공자의 발판 높이와 자세가 기본심폐소생술의 정확도에 미치는 영향)

  • Choi, Eun-Sook;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.3
    • /
    • pp.27-41
    • /
    • 2008
  • Purpose : The purpose of this study was to supply basic data for the impact on the accuracy of basic CPR according to position and foot-board height of basic CPR provider. Methods : Study design was within - group design. Subjects were 25 EMT-P Students in K city. Interventions was basic CPR performed on a resuscitation manikin placed on a hospital bed, kneeling on the bed adjacent to the manikin. Data was analyzed using descriptive statistics and Friedman test. Results : In case of the basic CPR performed on a resuscitation manikin placed on a hospital bed, ventilation accuracy was the highest in less than 160 cm height, foot-board height : $34.2{\pm}1.48cm$, 91.4% and in 161-165 cm height, foot-board height : $26.0{\pm}2.14cm$, 88.4% and in 171-175 cm height, foot-board height : $23.0{\pm}1.41cm$, 91.3% and in the above 176 cm, kneeling on the bed, 95%. Chest compression accuracy was the highest in less than 160 cm height, foot-board height : $30.2{\pm}1.48cm$, 95.6% and in 161-165 cm height, kneeling on the bed, 97.6% and in 171-175 cm height, kneeling on the bed, 98.5% and in the above 176 cm, kneeling on the bed, 98.7% and foot-board height : $20.5{\pm}1.91cm$, 98.7%. Chest compression error was due to too weak : 2.0-35.4 times. There were ststistically significant differences in 191-195 cm group according to chest compression mean depths($x^2=10.824$, p = .013) and chest compression error (p = .040). Conclusion : In contrast to current guidelines, the position and foot-board height of basic CPR provider are very important to the accuracy of the basic CPR. Furthermore, we recommend that a using real time audiovisual feedaback system significantly improve the quality of chest compression and ventilation during resuscitation.

  • PDF

A Study on the Seismic Isolated Bed System Considering the Seismic Stability of an Emergency Diesel Generator (내진안정성을 고려한 비상디젤발전기의 방진베드시스템에 관한 연구)

  • Ha, Neung-Gyo;Kim, Chae-Sil
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_3
    • /
    • pp.1155-1163
    • /
    • 2022
  • This study proposes a technology to ensure the seismic stability of a 1,000 kW diesel engine-type emergency generator by applying a seismic isolated bed system. The technology allows the static analysis by making the first natural frequency of the installed entire emergency generator larger than the earthquake cutoff frequency of 33 Hz. First a three dimensional model for the generator was made with simplification for mode analysis. A new bed system with springs, shock absorbers, stoppers was then devised. Next, The mode analysis for the finite element model equipped by the bed system was performed. the 1st natural frequency above 33 Hz, the seismic safety cutoff frequency, was calculated to be 152.92 Hz. Finally, based on the seismic stability theory, the von-Mises equivalent stresses derived by structural analysis under the Upset and Faulted conditions were 0.01603 Mpa, and 32.06 Mpa, respectively. so seismic stability was confirmed.

Comparative analysis of cardiopulmonary resuscitation accuracy and fatigue by posture in hospitals (병원 내 심폐소생술의 자세별 피로도와 가슴압박 정확도 비교 분석)

  • Cho, Ki-Hwa;Yun, Jong-Geun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.179-188
    • /
    • 2021
  • Purpose: This study aimed to identify effective cardiopulmonary resuscitation methods by comparing the fatigue of rescuers according to various positions in cardiopulmonary resuscitation situations conducted on beds in hospitals. Methods: An experimental study of students in the department of emergency medical service in H University, G Metropolitan City was conducted in four positions for applying chest pressure on mannequins on beds. Results: As a result of measuring the muscle fatigue of four muscle attachments according to the four positions conducted on the bed, the average was 3.4%, the P was significant at 0.001, and the fatigue difference was confirmed to occur depending on the attachment. An analysis of pressure depth by pose revealed that P1, P2, P3, and P4 have a depth of 58.3, 55.1, 56.4, and 56.3 mm, respectively, with P4 having the deepest depth. Conclusion: Among the various postures of the rescuer during cardiopulmonary resuscitation performed on the bed in the hospital, P1 is thought to be the most tiring, although its associated CPR quality is good.

A Study on the Area and Clearances around Patient Bed Space in Intensive Care Unit (중환자실 병상주변공간의 면적과 간격에 관한 연구)

  • Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.47-55
    • /
    • 2019
  • Purpose: This study tries to propose the dimensions and area related to patient bed and surroundings in ICU considering nurses' observation and medical care. Methods: Literature survey, 11 Case studies, some Interviews with nurses and measuring of medical equipments' dimension in ICU have been mobilized in order to deepen the ICU bed area standards. Results: 0.3m clearance between head wall and patient bed is necessary for emergency cases. The minimum distance at the foot of the bed should not be less than 0.9m for EMR cart and medical tray. The clear floor area of one bed and surroundings in open ward is $10.2m^2(3m{\times}3.4m)$. In a single-bed patient room, the minimum clear floor area is $16.0m^2(4m{\times}4m)$. Considering the control of cross infection in ICU, Single bed patient room is recommended. Implications: The result of this study can be applied to the design of ICU and legislation of ICU standard.

The evaluation of admission-discharge module system by OCS (입.퇴원 module 시스템의 효과 분석 -ocs 입원 관리 시스템 효과 분석-)

  • Song, Jung Hup
    • Quality Improvement in Health Care
    • /
    • v.12 no.1
    • /
    • pp.62-76
    • /
    • 2006
  • Background : There were so many patients who are waiting for admission in Emergency room in spite of more than one hundred empty beds everyday. This study was conducted to evaluate admission-discharge module system by OCS which reduce empty beds. Methods : The data of bed utilization in general beds from 2004 were reviewed. For evaluation of performance at admission-discharge module system by OCS, the change of Occupancy of bed were calculated. Results : The percentage of Average Bed Emptiness was changed from 13.8% to 9.2%. The residents in surgery(100%) and in internal medicine(75.5%) approved this system. Conclusion : The personnel in hospital recognized that it was very important to manage bed. The management of beds by OCS was helpful to reduce empty beds and was important.

  • PDF

A Survey on Prehospital Emergency Medical Service for the Improvement of Acute Coronary Syndrome Assessments - Focus on the Jecheon.Danyans Area - (급성관상동맥증후군 환자의 병원 전 119구급의료서비스 실태 및 개선방안 -충북 제천.단양을 중심으로-)

  • Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.293-299
    • /
    • 2008
  • From January, 2004 to July, 2007, 97 patients were diagnosed with Acute coronary syndrome(ACS) in Emergency Medical Center in Jecheon City in Korea. Among 97 patients, the prehospital assessment rates were as follows ; blood pressure check(27.80%, pulse rate check(33.0%), respiration check(23.7%). In hospital emergency care, oxygen supply was 52.6%, absolute bed rest was 12.4%, electrocardiogram(EKG) check was 4.1%, and nitroglycerin and intravenous fluid therapy was 0%. Therefore, ACS patients have not received sufficient prehospital cares till now. In order to improve the proficiency of the first aid emergency medical technicians(EMTs), it is necessary to provide the continuing On-the-job training(OJT) programs for prehospital emergency care.

The Fatal Paraquat Poisoning Through Skin Abrasion -Case Report- (피부 찰과상을 통한 파라쿼트 중독에 의한 사망 1례)

  • Kim, Sung-Eun;Cho, Jun-Hwi;Cheon, Seung-Whan;Lee, Seung-Young;Choi, Ki-Hoon;Bae, Ji-Hoon;Seo, Jeong-Yeul;Ahn, Hee-Cheol;Ahn, Moo-Eob;Ok, Taek-Gun;Park, Chan-Woo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.3 no.2
    • /
    • pp.122-125
    • /
    • 2005
  • Paraquat, is a widely used for its great effect as a herbicide. But the mortality rate by paraquat intoxication is known to be very high. It is thought to act by changing form to superoxide and peroxide free radical. Almost paraquat intoxication is through ingestion. A few intoxication of paraquat is through skin absorption. But there was no known death case through skin absorption. We experienced a case of a expired patient by paraquat intoxication through skin abrasion and scratching wound. A 75-year-old man was visited emergency room after motorcycle accident during transporting paraquat. He has multiple abrasion and scratching wound on extremities, and pelvic bone fracture. There was no evidence of ingestion of paraquat. But serum/urine gramoxone level was all positive. In spite of wound irrigation and hemoperfusion, his condition was been gone form bed to worse. 2 days after, multiple organ failure and the respiratory arrest were developed and he was expired. Paraquat intoxication through skin wound is extremely dangerous and death by that could possibly happen

  • PDF

A study on standardization & completion of transfer consultation record for patients transferred to emergency medical center (응급의료센터로 전원된 환자의 진료의뢰서 표준화 및 충실도에 관한 연구)

  • Yoou, Soonkyu;Kim, Kwang Hwan;Cho, Hae Kyung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.5 no.1
    • /
    • pp.177-198
    • /
    • 2001
  • The purpose of this research which was conducted by surveying the transfer consultation records from 360 medical institutions such as general hospitals, hospitals, clinics to the Emergency Medical Center at E University Hospital for six months(Jan. 1, 2000 - Jun. 30, 2000) are to standardize & complete transfer consultation record of hospitals at the 1st & 2nd referral level and to give patients transferred emergency medical center medical information services on a better quality. The conclusions and suggestions from this study were summarized as follows; (1) Examing the distribution of the referral medical consultation(transfer) sheet type, surgery part local clinic sheet types were 34.4%, medical part local clinic sheet types were 26.7%, undifferentiated local clinic sheet types were 23.9% and hospital level sheet types were 15.0%. (2) The items of the transfer consultation records had been standardized more than 75% in the order of patient's name, date, doctor's name, diagnosis, patient's status, impressions. (3) That the degree of recording completion on these items is in the order of patient's name, date, diagnosis, impressions was revealed. (4) Because the standardization and the degree of recording completion are very low in the patient's gender, age, address, electronic recording system was needed for more perfect input of initial patient informations. (5) This standardizing & complete recording on examination and medication will prevent re-examination and abuse of medication for patients transferred emergency medical center. (6) EMT Transfer System should be fixed in all medical institute for the standardizing & complete recording on care period and departure time will give many emergency patients the proper treatments at the proper time. (7) It was revealed that developing new standardized transfer consultation record & using electronic recording system are needed. (8) The complete recording & Fast Track System were needed for higher rate of bed operation at emergency medical center and more hospital profit.

  • PDF

The Effect of Music Therapy on Anxiety of Patients in Emergency Room (음악요법이 응급실 환자의 불안에 미치는 영향)

  • Lee, Pyung-Hwa;Suh, In-Sun;Chung, Seung-Hee
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.3
    • /
    • pp.500-511
    • /
    • 2008
  • Purpose: The purpose of this study was to examine the effects of music therapy on anxiety of patients in emergency room. Methods: The study was designed using a noneqivalent control group nonsynchronized design. For 20 minutes, the experimental group(22 patients) had listened to music and the control group(23 patients) had bed rest. A six-item state anxiety scale developed by Marteau and Bekker, which was based on Spielberger's State-Trait Anxiety Inventory, blood pressure and pulse rate were measured to all study participants before and after the intervention. The data was analyzed by the SPSS 12.0 program. Results: 1) The experimental group's state anxiety level were significantly lower than the control group's(t=2.220, p=.032). 2) There were no significant differences in both group's diastolic(t=-.495, p=.623) and systolic blood pressure(t=831, p=.411). 3) The experimental group's pulse rate was significantly lower than the control group's(t=2.363, p=.023). Conclusion: Music therapy may be applied as a nursing intervention to decrease anxiety in emergency room.

  • PDF