• Title/Summary/Keyword: Embedded control unit

Search Result 140, Processing Time 0.024 seconds

Fault Localization Method by Utilizing Memory Update Information and Memory Partitioning based on Memory Map (메모리 맵 기반 메모리 영역 분할과 메모리 갱신 정보를 활용한 결함 후보 축소 기법)

  • Kim, Kwanhyo;Choi, Ki-Yong;Lee, Jung-Won
    • Journal of KIISE
    • /
    • v.43 no.9
    • /
    • pp.998-1007
    • /
    • 2016
  • In recent years, the cost of automotive ECU (Electronic Control Unit) has accounted for more than 30% of total car production cost. However, the complexity of testing and debugging an automotive ECU is increasing because automobile manufacturers outsource automotive ECU production. Therefore, a large amount of cost and time are spent to localize faults during testing an automotive ECU. In order to solve these problems, we propose a fault localization method in memory for developers who run the integration testing of automotive ECU. In this method, memory is partitioned by utilizing memory map, and fault-suspiciousness for each partition is calculated by utilizing memory update information. Then, the fault-suspicious region for partitions is decided based on calculated fault-suspiciousness. The preliminary result indicated that the proposed method reduced the fault-suspicious region to 15.01(%) of memory size.

Implementation of a BLU system for advertisements using a LED and Acryl (LED와 아크릴을 이용한 광고용 BLU 시스템 구현)

  • Kim, Han-Na;Lee, Hyuek-Jae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.4
    • /
    • pp.326-331
    • /
    • 2010
  • This paper has proposed and experimentally demonstrated a new BLU using an LED and an acryl, which is specially focused on the implementation about the guiding effect of an acryl luminous by the LED. While the conventional BLU using a fluorescent lamp is generally and widely used, it shows big power consumption with a short life even more too thick to hold on the wall. To solve such demerits, we propose a new method for a BLU using an LED and an acryl in this paper. This BLU system has various scratches on the surface of acryl to get diffusion effect of light, and has been included an embedded board that can dynamically control the colors and the intensity of the BLU through the Internet. We have conducted computer simulations to find out the optimal scratch pattern on the surface of the acryl for the backlight system. Based on the resulted out simulation. The the optimal scratch pattern signs has been developed. The simulation result shows 2,673Lux an average for a luminous intensity test, and the other hand, experiential result shows 2,554Lux. From the experiments, it is possible for the proposed BLU system to be used for real advertisements.

Design and Implementation of $\pi/4$ QPSK Satellite IP Modem Part ($\pi/4$ QPSK 위성 IP 모뎀부 설계 및 구현)

  • Kang, Jung-Mo;Jung, Jae-Wook;Kim, Myung-Sik;Oh, Woo-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1858-1865
    • /
    • 2007
  • In this paper, we introduce the design and implementation of satellite IP modem. The designed satellite IP modem shows the performance of 0.2% overhead, BER=10-5 when Eb/No=6dB, frequency offset of 8KHz, data rate up to 1536Kbps, $F_{if}=140MHz$. The designed system is verified through software simulation and then implemented with MPC86x communication processor, TMS320C6416 DSP, and Altera FPGA. Since each hardware unit is implemented in daughter board for modularity, we can reduce the development time and easily improve the performance with using better processor. Linux is used for embedded OS because it shows better performance in IP manipulation multitask processing, and hardware control through device driver. The implemented system is tested and verified with channel simulator. Since the proposed IP modem shows small size and light weight, that can be used anywhere with easy if you need IP environment.

The Developement of Small 360° Oral Scanner Lens Module (소형 360° 구강 스캐너 렌즈 모듈 개발)

  • Kwak, Dong-Hoon;Lee, Sun-Gu;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.858-861
    • /
    • 2018
  • In this paper, we propose the development of a small $360^{\circ}$ oral scanner lens module. The proposed small $360^{\circ}$ oral scanner lens module consists of a small $360^{\circ}$ high resolution(4MegaPixel) lens optical system, a 15mm image sensor unit, and a small $360^{\circ}$ mouth scanner lens external shape. A small $360^{\circ}$ high resolution lens optical system produces a total of nine lenses, the outer diameter of the lens not less than 15mm for use by children through the ages of adulthood. Light drawn by a small $360^{\circ}$ high resolution lens optical system is $90^{\circ}$ flexion so that image images are delivered to image sensors. The 15mm image sensor unit sends the converted value to the ISP(Image Signal Processor) of the embedded board after an image array through the column and the row address of the image sensor. The small $360^{\circ}$ mouth scanner lens outer shape was designed to fix the race to the developed lens. Results from authorized testing agencies to assess the performance of proposed small $360^{\circ}$ oral scanner lens modules, The optical resolving power of $360^{\circ}$ lens was more than 30% at 150 cycles/mm, $360^{\circ}$ lens angle was $360^{\circ}$ in vertical direction, $42^{\circ}{\sim}85^{\circ}$ in vertical direction, and lens distortion rate was 5% or less. It produced the same result as the world's highest level.

Semiconductor wafer exhaust moisture displacement unit (반도체 웨이퍼 공정 배기가스 수분제어장치)

  • Chan, Danny;Kim, Jonghae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5541-5549
    • /
    • 2015
  • This paper introduces a safer and more power efficient heater by using induction heating, to apply to the semiconductor wafer fabrication exhaust gas cleaning system. The exhaust gas cleaning system is currently made with filament heater that generates an endothermic reaction of N2 gas for the removal of moisture. Induction theory, through the bases of theoretical optimization and electronic implementation, is applied in the design of the induction heater specifically for the semiconductor wafer exhaust system. The new induction heating design provides a solution to the issues with the current energy inefficient, unreliable, and unsafe design. A robust and calibrated design of the induction heater is used to optimize the energy consumption. Optimization is based on the calibrated ZVS induction circuit design specified by the resonant frequency of the exhaust pipe. The fail-safe energy limiter embedded in the system uses a voltage regulator through the feedback of the MOSFET control, which allows the system performance to operate within the specification of the N2 Heater unit. A specification and performance comparison from current conventional filament heater is made with the calibrated induction heater design for numerical analysis and the proof of a better design.

THE EFFECTS OF IRRADIATION ON THE MANDIBULAR BONE OF RATS ON THE LOW CALCIUM DIET (방사선조사가 저칼슘식이 백서의 하악골에 미치는 영향에 관한 실험적 연구)

  • Hwang Eui-Hwan;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.241-252
    • /
    • 1992
  • The purpose of this study was to investigate the changes of morphology and structure of bone tissue in the irradiated mandibular bone in rats which were fed a low calcium diet. In order to carry out this experimant, 64 seven-week old Sprague-Dawley strain rats weighing about 150gms were selected and equally divided into one experimental group of 32 rats and one control group with the remainder. The experimental group and the control group were then subdivided into two groups when the rats reached ten-week old, 16 were assigned rats for each subdivided group, exposed to irradiation. The two irradiation groups received a single dose of 20 Gy in the jaws area only and irradiated with a cobalt-60 teletherapy unit. The rats in the control and experimental groups were serially terminated by fours on the 3rd, the 7th, the 14th, and the 21st day after irradiation. Following termination, both sides of the dead rats mandibular bodies were removed and fixed with 10% neutral formalin. One side of the mandibular body was radiographed with a soft X-ray apparatus. Thereafter, the obtained microradiographs were observed by a light microscope. The remaining side of the mandibular bone was further decalcified and embedded in paraffin as using the general method. The specimen sectioned and stained with hematoxylin and eosin, and Rabit Anti-Human Tumor Necrosis Factor-a, observed by a light microscope. The obtained results were as follows: 1. Microradiogram revealed that thinning of the cortex and a decrease in the trabecula of the interradicular bone and mandibular body were observed and noted from the start to finish throughout the experiment in the non-irradiated rats on the low calcium diet rather than in the non-irradiated rats on the normal diet. In microscopic observations, there were marked osteolytic changes in the center of the bone marrow. 2. Microradiogram revealed that thinning of the cortex and a decrease in the trabecula of interradicular bone and mandibular body were more marked after 7 days in the irradiated rats on the low calcium diet rather than in the non-irradiated rats on the low clacium diet. In microscopic observations, osteoblasts were decreased markedly after 7 days, and a few osteoclasts were observed. 3. Microradiogram revealed that thinning of the cortex and a decrease in trabecula of interradicular bone and the mandibular body were more marked from the strart to finish troughout the experiment in the irradiated rats on the low calcium diet rather than in the irradiated rats on the normal diet. In microscopic observations, there were no osteolytic changes noted in the irradiated rats on the normal diet. 4. In immunocytochemical findings, a few bone marrow cells including Tumor Necrosis Factor were observed in the irradiated rats on the normal diet, but was not observed in the rats on the low calcium diet.

  • PDF

THE EFFECTS OF THE LOW CALCIUM DIET AND IRRADIATION ON THE MANDIBULAR CONDYLE OF RATS (저칼슘식이와 방사선조사가 백서하악과두에 미치는 영향에 관한 실험적 연구)

  • Ahn Hee-Mun;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.1
    • /
    • pp.27-44
    • /
    • 1993
  • This study was performed to investigate the changes of mandibular condyle by low calcium diet and the effects of irradiation on the bone in osteoporotic state. In order to carry out this experiment, 80 seven-week old Sprague-Dawley strain rats weighing about 150 gm were selected and equally divided into one experimental group of 40 rats and one control group with the remainder. The experimental group and the control group were then subdivided into two group and exposed to irradiation. The two irradiation groups received a single dose of 20 Gy on the jaw area only and irradiated with a cobalt-60 teletherapy unit. The rats in the control and experimental groups were serially terminated by fours on the 3rd, the 7th, the 14th, and the 21st day after irradiation. After termination, both sides of the dead rats mandibular condyle were removed and fixed with 10% neutral formalin. The bone mineral density of mandibular condyle was measured by use of dual energy X-ray bone densitometer(model DDX-alpha, Lunn Corp., U. S. A.). The mandibular condyle was radiographed with Hitex HA-80(Hitex Co., Japan). Thereafter, the obtained radiographs were observed, and the mandibular condyle was further decalcified and embedded in paraffin as the general method. The specimen sectioned and stained with hematoxylin-eosin, PAS and Rabbit Anti-Human Tumor Necrosis Factor-a observed by a light microscope. The obtained results were as follows: 1. In the non-irradiated group with the low calcium diet, the bone mineral density of the condyle was markedly decreased after 14 days, and decrease the number of trabeculae of the condyle and resorption of the calcified cartilaginous zone were observed after 3 days. On microscopic observations, the number nd size of trabeculae were decreased after 7 days of experiment. 2. In the irradiated group with the low calcium diet, the bone mineral density of the condyle was markedly decreased after 14 days and resorption of the calcified cartilaginous zone and decrease the number and coarse of the trabeculae of the condyle were observed. These findings were extended rather than in non-irradiated group with low calcium diet. On microscopic observations, many osteoclasts were detected and the number and size of trabeculae were somewhat decreased after 7 days. Also there was degenerative changes of tissues of bone marrow on the 14th day but that condition was restored on the 21st day of experiment. 3. In the irradiated group with normal diet, the bone mineral density of the condyle was somewhat decreased with times and degree of decrease of the number of trabeculae was somewhat larger than in the non-irradiated group with normal diet. On microscopic observations, the tissues of bone marrow were atrophic and degenerative changes but that condition was restored on the 21st day of experiment. 4. In immunocytochemical findings, in the irradiated and non-irradiated groups with low calcium diet, negative or partial positive response to TNF was observed, but positive response in the normal diet groups.

  • PDF

Multiple SL-AVS(Small size & Low power Around View System) Synchronization Maintenance Method (다중 SL-AVS 동기화 유지기법)

  • Park, Hyun-Moon;Park, Soo-Huyn;Seo, Hae-Moon;Park, Woo-Chool
    • Journal of the Korea Society for Simulation
    • /
    • v.18 no.3
    • /
    • pp.73-82
    • /
    • 2009
  • Due to the many advantages including low price, low power consumption, and miniaturization, the CMOS camera has been utilized in many applications, including mobile phones, the automotive industry, medical sciences and sensoring, robotic controls, and research in the security field. In particular, the 360 degree omni-directional camera when utilized in multi-camera applications has displayed issues of software nature, interface communication management, delays, and a complicated image display control. Other issues include energy management problems, and miniaturization of a multi-camera in the hardware field. Traditional CMOS camera systems are comprised of an embedded system that consists of a high-performance MCU enabling a camera to send and receive images and a multi-layer system similar to an individual control system that consists of the camera's high performance Micro Controller Unit. We proposed the SL-AVS (Small Size/Low power Around-View System) to be able to control a camera while collecting image data using a high speed synchronization technique on the foundation of a single layer low performance MCU. It is an initial model of the omni-directional camera that takes images from a 360 view drawing from several CMOS camera utilizing a 110 degree view. We then connected a single MCU with four low-power CMOS cameras and implemented controls that include synchronization, controlling, and transmit/receive functions of individual camera compared with the traditional system. The synchronization of the respective cameras were controlled and then memorized by handling each interrupt through the MCU. We were able to improve the efficiency of data transmission that minimizes re-synchronization amongst a target, the CMOS camera, and the MCU. Further, depending on the choice of users, respective or groups of images divided into 4 domains were then provided with a target. We finally analyzed and compared the performance of the developed camera system including the synchronization and time of data transfer and image data loss, etc.

Development of T-commerce Processing Payment Module Using IC Credit Card(EMV) (IC신용카드(EMV)를 이용한 T-커머스 결제처리 모듈 개발)

  • Choi, Byoung-Kyu;Lee, Dong-Bok;Kim, Byung-Kon;Heu, Shin
    • The KIPS Transactions:PartA
    • /
    • v.19A no.1
    • /
    • pp.51-60
    • /
    • 2012
  • IC(Integrated circuits)card, generally be named smard card, embedded MPU(Micro Processor Unit) of small-size, memory, EEPROM, Card Operating System(COS) and security algorithm. The IC card is used in almost all industry such as a finance(credit, bank, stock etc.), a traffic, a communication, a medical, a electronic passport, a membership management and etc. Recently, a application field of IC card is on the increase by method for payments of T-commerce, as T-commerce is becoming a new growth engine of the broadcating industry by trend of broadcasting and telecommunication convergence, smart mechanization of TV. For example, we can pay in IC credit card(or IC cash card) on T-Commerce. or we can be provided TV banking service in IC cash card such as ATM. However, so far, T-commerce payment services have weakness in security such as storage and disclosure of card information as well as dropping sharply about custom ease because of taking advantage of card information input method using remote control. To solve this problem, This paper developed processing payment module for implementing TV electronic payment system using IC credit card payment standard, EMV.

Comparison of Bonding Strength by Cleaning Method of Pediatric Zirconia Crown Contaminated with Saliva or Blood (타액 및 혈액오염 시 유치 지르코니아 기성관 내면의 세척 방법에 따른 결합강도의 비교)

  • Kim, Jaeyong;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.2
    • /
    • pp.185-194
    • /
    • 2018
  • The objective of this study was to compare the shear bonding strength of zirconia after cleaning the crown contaminated by saliva or blood and determine the effect of thermocycling. 180 specimens were embedded in acrylic resin. 20 Specimens in the positive control group were bonded with resin cement without contamination. 20 Specimens in the negative control group were washed with water for 20 seconds and then dried for 10 seconds. 120 Specimens contaminated by saliva or blood were cleaned by using three cleaning methods: 37% phosphoric acid gel, commercial cleanse, and 2.5% NaOCl. All samples were bonded with resin cement and divided into two subgroups: One was not aged, and the other was tested with 30,000 thermocycling. In both groups contamination by saliva and blood, no statistically significant difference was not found in control, groups cleansed by commercial cleanser and 2.5% NaOCl. When the groups cleansed with water and 37% phosphate gel were compared with the control, significantly low shear bond strength was shown. Thermocycling group showed statistically significantly low shear bond stress compared to the groups without thermocycling. When zirconia was contaminated by saliva or blood, its original shear bond strength could be obtained if it was cleaned with commercial cleanser or 2.5% NaOCl.