• Title/Summary/Keyword: Ellipsoid modeling

Search Result 21, Processing Time 0.026 seconds

Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique

  • Hur, Beong Ik;Jin, Seong Jin;Kim, Gyeong Rip;Kwak, Jong Hyeok;Kim, Young Ha;Lee, Sang Weon;Sung, Soon Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.13-22
    • /
    • 2021
  • Objective : High precision and accuracy are expected in gamma knife radiosurgery treatment. Because of the requirement of clinically applying complex radiation and dose gradients together with a rapid radiation decline, a dedicated quality assurance program is required to maintain the radiation dosimetry and geometric accuracy and to reduce all associated risk factors. This study investigates the validity of Leksell Gamma plan (LGP)10.1.1 system of 5th generation Gamma Knife Perfexion as modified variable ellipsoid modeling technique (VEMT) method. Methods : To verify LGP10.1.1 system, we compare the treatment plan program system of the Gamma Knife Perfexion, that is, the LGP, with the calculated value of the proposed modified VEMT program. To verify a modified VEMT method, we compare the distributions of the dose of Gamma Knife Perfexion measured by Gafchromic EBT3 and EBT-XD films. For verification, the center of an 80 mm radius solid water phantom is placed in the center of all sectors positioned at 16 mm, 4 mm and 8 mm; that is, the dose distribution is similar to the method used in the x, y, and z directions by the VEMT. The dose distribution in the axial direction is compared and analyzed based on Full-Width-of-Half-Maximum (FWHM) evaluation. Results : The dose profile distribution was evaluated by FWHM, and it showed an average difference of 0.104 mm for the LGP value and 0.130 mm for the EBT-XD film. Conclusion : The modified VEMT yielded consistent results in the two processes. The use of the modified VEMT as a verification tool can enable the system to stably test and operate the Gamma Knife Perfexion treatment planning system.

Comparisons between the Two Dose Profiles Extracted from Leksell GammaPlan and Calculated by Variable Ellipsoid Modeling Technique (렉셀 감마플랜(LGP)에서 추출된 선량 분포와 가변 타원체 모형화기술(VEMT)에 의해 계산된 선량 분포 사이의 비교)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • A high degree of precision and accuracy in Gamma Knife Radiosurgery(GKRS) is a fundamental requirement for therapeutical success. Elaborate radiation delivery and dose gradients with the steep fall-off of radiation are clinically applied thus necessitating a dedicated Quality Assurance(QA) program in order to guarantee dosimetric and geometric accuracy and reduce all the risk factors that can occur in GKRS. In this study, as a part of QA we verified the accuracy of single-shot dose profiles used in the algorithm of Gamma Knife Perfexion(PFX) treatment planning system employing Variable Ellipsoid Modeling Technique(VEMT). We evaluated the dose distributions of single-shots in a spherical ABC phantom with diameter 160 mm on Gamma Knife PFX. The single-shots were directed to the center of ABC phantom. Collimating configurations of 4, 8, and 16 mm sizes along x, y, and z axes were studied. Gamma Knife PFX treatment planning system being used in GKRS is called Leksell GammaPlan(LGP) ver 10.1.1. From the verification like this, the accuracy of GKRS will be doubled. Then the clinical application must be finally performed based on precision and accuracy of GKRS. Specifically the width at the 50% isodose level, that is, Full-Width-of-Half-Maximum(FWHM) was verified under such conditions that a patient's head is simulated as a sphere with diameter 160mm. All the data about dose profiles along x, y, and z axes predicted through VEMT were excellently consistent with dose profiles from LGP within specifications(${\leq}1mm$ at 50% isodose level) except for a little difference of FWHM and PENUMBRA(isodose level: 20%~80%) along z axis for 4 mm and 8mm collimating configurations. The maximum discrepancy of FWHM was less than 2.3% at all collimating configurations. The maximum discrepancy of PENUMBRA was given for the 8 mm collimator along z axis. The difference of FWHM and PENUMBRA in the dose distributions obtained with VEMT and LGP is too small to give the clinical significance in GKRS. The results of this study are considered as a reference for medical physicists involved in GKRS in the whole world. Therefore we can work to confirm the validity of dose distributions for all collimating configurations determined through the regular preventative maintenance program using the independent verification method VEMT for the results of LGP and clinically assure the perfect treatment for patients of GKRS. Thus the use of VEMT is expected that it will be a part of QA that can verify and operate the system safely.

Numerical modeling of heterogeneous material

  • Puatatsananon, W.;Saouma, V.;Slowik, V.
    • Computers and Concrete
    • /
    • v.5 no.3
    • /
    • pp.175-194
    • /
    • 2008
  • Increasingly numerical (finite element) modeling of concrete hinges on our ability to develop a representative volume element with all its heterogeneity properly discretized. Yet, despite all the sophistication of the ensuing numerical models, the initial discretization has been for the most part simplistic. Whenever the heterogeneity of the concrete is to be accounted for, a mesh is often manually crafted through the arbitrary inclusion of the particles (aggregates and/or voids) in an ad-hoc manner. This paper develops a mathematical strategy to precisely address this limitation. Algorithms for the random generation and placement of elliptical (2D) or ellipsoid (3D) inclusions, with possibly radiating cracks, in a virtual concrete model are presented. Collision detection algorithms are extensively used.

3-D Hand Motion Recognition Using Data Glove (데이터 글로브를 이용한 3차원 손동작 인식)

  • Kim, Ji-Hwan;Park, Jin-Woo;Thang, Nguyen Duc;Kim, Tae-Seong
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.324-329
    • /
    • 2009
  • Hand Motion Modeling and Recognition (HMR) are a fundamental technology in the field of proactive computing for designing a human computer interaction system. In this paper, we present a 3D HMR system including data glove based on 3-axis accelerometer sensor and 3D Hand Modeling. Data glove as a device is capable of transmitting the motion signal to PC through wireless communication. We have implemented a 3D hand model using kinematic chain theory. We finally utilized the rule based algorithm to recognize hand gestures namely, scissor, rock and papers using the 3-D hand model.

  • PDF

Modeling of External Impulse via the Concept of an Effective Mass in Sawing Task

  • Lee, Jae-Hoon;Park, Byung-Joon;Yi, Byung-Ju;Suh, Il-Hong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2713-2718
    • /
    • 2003
  • Some of manufacturing tasks such as sawing task often requires continuous impulsive motion. In case of sawing task, such impulsive motions can be observed between the teeth of the saw and the object. The amount of the external impulse exerted on the object has been treated as an important control parameter. The purpose of this work is to introduce a new concept of an effective mass in sawing task and to suggest an external impulse model in sawing task. A normalized impulse ellipsoid reflecting the velocity direction is employed to visualize the impact geometry. Experiments are performed for soft and hard workpieces to justify the external impulse model in the sawing task. It is demonstrated through simulation and experiment that the proposed external impulse model is effective to characterize the impact property.

  • PDF

Determination of the Deflection of Vertical Components via GPS and Leveling Measurement : A Case Study of Chunchoen, Gangwon-do (GPS/Leveling을 이용한 연직선 편차 성분 계산 : 강원도 춘천지역을 중심으로)

  • Shin, Moon-Seung;Lee, Dong-Ha;Yang, In-Tae
    • Journal of Industrial Technology
    • /
    • v.36
    • /
    • pp.65-69
    • /
    • 2016
  • Deflection of the vertical is used in geodetic surveying associated with geoid network construction for geoid modeling and ellipsoid decision and obtained by gravity survey, astronomic survey etc. Technique of astronomic survey and gravity survey is very complex and requires a significant amount of time until gathering data. So this study is to determined a various method which evaluates deflection of the vertical and components about deflection of the vertical using GPS results and orthometric height value decided by leveling. Results of components about deflection of the vertical using GPS/leveling is that ${\xi}$ conponent is distributed $-2.11^{{\prime}{\prime}}{\pm}0.62$, ${\eta}$ component is distributed $1.75^{{\prime}{\prime}}{\pm}0.71$. Decision of component about deflection of the vertical using GPS is less complex than existing astronomic survey. Decision of component about deflection of vertical line using GPS is not complicated than astronomic surveying and can determine in a very short time. So it will be important means to determine the exact orthometric height, topographic study and diastrophism if can periodically calculate.

  • PDF

Atmospheric Correction and Velocity Aberration for Physical Sensor Modeling of High-Resolution Satellite Images (고해상도 위성영상의 센서모델링을 위한 대기 및 속도 보정)

  • Oh, Jae-Hong;Lee, Chang-No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.5
    • /
    • pp.519-525
    • /
    • 2011
  • High-resolution earth-observing satellites acquire substantial amount of geospatial images. In addition to high image quality, high-resolution satellite images (HRSI) provide unprecedented direct georegistration accuracy, which have been enabled by accurate orbit determination technology. Direct georegistration is carried out by relating the determined position and attitude of camera to the ground target, i.e., projecting an image point to the earth ellipsoid using the collinearity equation. However, the apparent position of ground target is displaced due to the atmosphere and satellite velocity causing significant georegistration bias. In other words, optic ray from the earth surface to satellite cameras at 400~900km altitude refracts due to the thick atmosphere which is called atmospheric refraction. Velocity aberration is caused by high traveling speed of earth-observing satellites, approximately 7.7 km/s, relative to the earth surface. These effects should be compensated for accurate direct georegistration of HRSI. Therefore, this study presents the equation and the compensation procedure of atmospheric refraction and velocity aberration. Then, the effects are simulated at different image acquisition geometry to present how much bias is introduced. Finally, these effects are evaluated for Quickbird and WorldView-1 based on the physical sensor model.

Prediction and Verification of the Twist Deformation of Automotive Structure Parts after Hybrid Welding Using CAE (CAE 를 통한 하이브리드 용접 후 차체부품 변형예측 및 검증)

  • Lee, Dug-Young;Choi, Bo-Sung;Choi, Won-Ho;Ahn, Jang-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.1
    • /
    • pp.87-95
    • /
    • 2012
  • In recent years, laser-arc hybrid welding has begun to be adopted for assembly welding of automotive bodies and parts, because the hybrid welding process can weld lapped steel sheets having a larger gap than is possible with laser welding. In this paper, to predict the twist deformation by the hybrid welding when brackets are welded in B pillar of a passenger car, the residual stress using CAE is analyzed and the deformation result of CAE is compared with the measured deformation. First of all, after modeling heat source as intended to be expressed with laser-arc hybrid welding method, heat source fitting is done with welding conditions and a section of welding part obtained through specimen test. In case of heat source functions, laser used conical source and arc used double ellipsoid source. Through the local model analysis, elements which are located in the center of the model are selected. The elements are called WME(Welding Macro Element). This WME is extruded in the welding lines and welding phenomenon of complex parts is accomplished. The deformation amount after hybrid welding is got through a simulation, the validity of simulation is verified by measuring the panel and comparing with the simulation result.

Analyses of the indispensible Indices in Evaluating Gamma Knife Radiosurgery Treatment Plans (감마나이프 방사선수술 치료계획의 평가에 필수불가결한 지표들의 분석)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.303-312
    • /
    • 2017
  • The central goal of Gamma Knife radiosurgery(GKRS) is to maximize the conformity of the prescription isodose surface, and to minimize the radiation effect of the normal tissue surrounding the target volume. There are the various kinds of indices related with the quality of treatment plans such as conformity index, coverage, selectivity, beam-on time, gradient index(GI), and conformity/gradient index(CGI). As the best treatment plan evaluation tool, we must check by all means conformity index, GI, and CGI among them. Specially, GI and CGI related with complication of healthy normal tissue is more indispensible than conformity index. Then author calculated and statistically analysed CGI, the newly defined conformity/gradient index as well as GI being applied widely using the treatment planning system Leksell GammaPlan(LGP) and the verification method Variable Ellipsoid Modeling Technique(VEMT). In the study 10 patients with intracranial lesion treated by GKRS were included. Author computed the indices from LGP and VEMT requiring only four parameters: the prescribed isodose volume, the volume with dose > 30%, the target volume, and the volume of half the prescription isodose. All data were analyzed by paired t-test, which is statistical method used to compare two different measurement techniques. No statistical significance in GI at 10 cases was observed between LGP and VEMT. Differences in GI ranged from -0.14 to 0.01. The newly defined gradient index calculated by two methods LGP and VEMT was not statistically significant either. Author did not find out the statistical difference for the prescribed isodose volume between LGP and VEMT. CGI as the evaluation index for determining the best treatment plan is not significant statistically also. Differences in CGI ranged from -4 to 3. Similarly newly defined Conformity/Gradient index for GKRS was also estimated as the metric for the evaluation of the treatment plans through statistical analysis. Statistical analyses demonstrated that VEMT was in excellent agreement with LGP when considering GI, new gradient index, CGI, and new CGI for evaluating the best plans of GKRS. Due to the application of the fast and easy evaluation tool through LGP and VEMT author hopes CGI and newly defined CGI as well as gradient indices will be widely used.

Developing a Cellular Automata-based Pedestrian Model Incorporating Physical Characteristics of Pedestrians (보행자의 물리적 특성을 반영한 CA기반 보행모델)

  • Nam, Hyunwoo;Kwak, Suyeong;Jun, Chulmin
    • Spatial Information Research
    • /
    • v.22 no.2
    • /
    • pp.53-62
    • /
    • 2014
  • The floor field model is the micro pedestrian model based on a cellular automata for modeling pedestrian movement in the interior space using the static and dynamic floor field. It regards a form of pedestrian as square but the actual pedestrian's shape and size are similar to ellipsoid or rectangle. Because of this, we are difficult to give a rotation effect to pedestrians and there is a limit to reflect an impact of clogging and jamming. Also, this model is not able to reflect an impact of a posture and visibility effectively in the pedestrian movement. In this study, we suggest the improved pedestrian model incorporating the actual shape and size of pedestrian. The pedestrian's shape is defined not square but rectangle which is close to the actual body size of Korean. Also, we define the model which is able to represent the impact of clogging and jamming between pedestrians by adding the pedestrian's posture. We develop the simulator for testing the suggested model and study the difference between two models by comparing a number of effects. As a result, we could confirm solving the problem with dynamic value in the existed model and reflecting the panic effect in evacuation situation.