• 제목/요약/키워드: Elevator Design

검색결과 197건 처리시간 0.09초

Elevator Pressurization in Tall Buildings

  • Klote, John H.
    • International Journal of High-Rise Buildings
    • /
    • 제2권4호
    • /
    • pp.341-344
    • /
    • 2013
  • During a building fire, smoke can flow through elevator shafts threatening life on floors remote from the fire. Many buildings have pressurized elevators intended to prevent such smoke flow. The computer program, CONTAM, can be used to analyze the performance of pressurization smoke control systems. The design of pressurized elevators can be challenging for the following reasons: (1) often the building envelope is not capable of effectively handling the large airflow resulting from elevator pressurization, (2) open elevator doors on the ground floor tend to increase the flow from the elevator shaft at the ground floor, and (3) open exterior doors on the ground floor can cause excessive pressure differences across the elevator shaft at the ground floor. To meet these challenges, the following systems have been developed: (1) exterior vent (EV) system, (2) floor exhaust (FE) system, and ground floor lobby (GFL) system.

Use of elevator instruments when luxating and extracting teeth in dentistry: clinical techniques

  • Mamoun, John
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권3호
    • /
    • pp.204-211
    • /
    • 2017
  • In dentistry, elevator instruments are used to luxate teeth, and this technique imparts forces to tooth particles that sever the periodontal ligament around tooth roots inside the socket and expand alveolar bone around tooth particles. These effects can result in extraction of the tooth particles or facilitate systematic forceps extraction of the tooth particles. This article presents basic oral surgery techniques for applying elevators to luxate teeth. Determination of the optimal luxation technique requires understanding of the functions of the straight elevator and the Cryer elevator, the concept of purchase points, how the design elements of elevator working ends and tips influence the functionality of an elevator, application of forces to tooth particles, sectioning teeth at furcations, and bone removal to facilitate luxation. The effectiveness of tooth particle luxation is influenced by elevator tip shape and size, the magnitude and the vectors of forces applied to the tooth particle by the tip, and sectioning and bone removal within the operating field. Controlled extraction procedures are facilitated by a dental operating microscope or the magnification of binocular surgical loupes telescopes, combined with co-axial illumination.

Design and Manufacture of Rope Brake for Elevator (엘리베이터용 로프 브레이크의 설계 및 제작)

  • 이종선;김정훈
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제5권2호
    • /
    • pp.93-97
    • /
    • 2004
  • This paper is purpose to the design and manufacture of rope brake for elevator. In generally, rope brake systems are second safety device for elevator. Therefore rope brake systems are very important device and very difficult device of design and manufacture. Also, this paper is object to reduced process order and process error.

  • PDF

A Study on the Elevator Spar Improvement for the Operating Aircraft (장기 운영항공기 승강타 날개보 구조개선 연구)

  • Shim, Daisung;Kim, Mantae;Yeom, Hyowon;Im, Dongmin;Kim, Youngjin;Uhm, Wonseop
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • 제19권6호
    • /
    • pp.675-680
    • /
    • 2016
  • This is a study for the improvement of the defected elevator spar in operating aircraft. The elevator spar web holes were analyzed to find out the cause of the cracks. The fatigue striations were observed and the cracks occurred by the repetitive stresses during the elevator works. Also the outboard connection structure of the elevator and horizontal stabilizer was more weak shape than the inboard. The design changes were recommended and the analyses were performed to verify the improvement of the changed shapes.

Safety Management Improvement Plan for Elevator Worker Safety Accident Prevention (승강기작업자 안전사고예방을 위한 안전관리 개선 방안)

  • Kim, Beom-Sang;Park, Poem
    • Journal of the Korea Safety Management & Science
    • /
    • 제22권2호
    • /
    • pp.23-29
    • /
    • 2020
  • Korea's elevator industry is one of the world's eighth-largest industrial sectors and the third largest in the world by new installations. This year, the number of elevators has exceeded 700,000, and the number of new installations is 30,000-40,000 every year. However, the news of elevator-related accidents is reported continuously through the media and the accident rate is not decreasing. In particular, among the recent accidents related to elevators, accidents related to elevator workers are increasing, causing social problems. This year, the National Assembly's Environmental Labor Relations Commission's National Auditors lost five lives a year and 12 elevator workers were killed in fall and stenosis accidents during the installation, maintenance and replacement of the elevators for about two years since 2018. It took place to adopt the representatives of four domestic elevator companies as witnesses. An elevator worker is a collective term for workers involved in the design, manufacturing, installation, replacement, maintenance, inspection, management, and supervision related to the elevator industry, and the related accidents are called elevator worker accidents. Analysis of elevator-related accidents in the past has shown that the fault of the user accounted for 70% of the total, and the fault of the worker accounted for about 2.5%, and the accident occurred to the user or the user due to carelessness of the worker during the lift-related work. Currently, elevator-related accidents are reported by the Korea Elevator Safety Agency under Article 48 of the Elevator Safety Management Act under the Ministry of Interior and Safety. If deemed necessary for the prevention and prevention of recurrence of an elevator accident, the cause and condition of the elevator accident may be investigated. However, the current draft law is limited only to elevators after installation inspection, and is separated from the Ministry of Employment and Labor's data on accidents occurring in the manufacturing and installation stages related to the elevator industry. This study analyzes the recent safety accidents of elevator workers and prepares safety measures to prevent them through the risk analysis, and also draws out the problems and improvements of the current elevator worker accident investigation to find the elevator worker accident rate that is on the increase trend.

A study on the performance analysis for the elevator system of the high-rise buildings (초대형 고층 빌딩의 엘리베이터 시스템 성능 평가에 관한 연구)

  • Kim, Hyo-Sup;Lim, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.558-560
    • /
    • 1999
  • For the high-rise buildings, the effective use of the buildings heavily depends on the transportation system inside the buildings. For a long period of time, elevators have been the most effective means for moving people residing in the buildings. As the number of elevators in the building grows, it is very complicated to control and manage the elevator system effectively. Since it is almost impossible to find the accurate mathematical model for the elevator systems, the conventional analysis method using the approximated equations is prone to error. In this work, the elevator simulator for the high-rise buildings is developed to assess the accurate behavior of the elevator systems. This simulator can be used to analyze the performance of the given system, or to facilitate the design of the effective elevator systems for new buildings. In this paper, the structure of the simulator has been explained and the simulation results are presented.

  • PDF

A Study on escape using elevators in fire emergency (화재 시 승강기를 이용한 피난에 관한 연구)

  • Chung, Eui-Soo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 대한안전경영과학회 2007년도 추계학술대회
    • /
    • pp.55-68
    • /
    • 2007
  • Because of not accepted on escape using elevators in fire emergency has some background. In the background elevator hoistway has turn into smoke spread route in fire. The escape that used an elevator was not able to make ends meet; of the big confusion is expected that cannot control the escape adequately, and do that elevator facilities breakdown possibility by the fire water, the escaper shut in car. Therefore ban on elevator service in fire time as a general rule. Recently, a few company promote super high-rise architecture in the country, a fire disaster prevention and human life safety measures preparation for PBD(A Performance Based Fire Protection Design) are studied concretely. And there is the escape example in fire time that used an elevator in the foreign country. You must promote it so that the escape measures that used enclosed stairway and an elevator in charge of a function of the mutual supplement. The result of this research can be used for establishing the standard and regulation for using elevators in fire emergency.

  • PDF

Design and Implementation of an Elevator Vibration Measuring System using 3-Axis Acceleration Sensor (3축 가속도 센서를 이용한 엘리베이터 진동측정시스템 설계 및 구현)

  • Choi, Sung-Hyun;Kim, Jong-Soo;Kim, Tai-Suk;Yu, Yun-Sik
    • Journal of Korea Multimedia Society
    • /
    • 제16권2호
    • /
    • pp.226-233
    • /
    • 2013
  • Self-diagnosis, regular examination, completion examination and precise safety examination on an elevator offer primary sources for evaluating performance and stability of the elevator. as critical examination for operating the elevator. The items on vibration of an elevator in the self-diagnosis and safety examination are not especially specified but vibration itself is considered as essential element to provide diverse analysis data. There is the equipment "EVA-625" for measuring vibration of an elevator. It is operated by reading data via computer and analyzing data by skilled engineer. This study aims to design and realize software to analyze data collected through the LabVIEW, a graphic program language and hardware for receiving data measuring vibration of an elevator by using 3-Axis acceleration sensor.

Design and Implementation of Elevator Control and Information System based on Media Streaming Service (미디어 스트리밍 서비스 기반 엘리베이터 제어 및 정보 시스템 설계 및 구현)

  • Kim, Woon-Yong;Park, Seok-Gyu
    • Journal of Advanced Navigation Technology
    • /
    • 제14권3호
    • /
    • pp.409-414
    • /
    • 2010
  • Recently, It has enlarged various service requirements for the market of elevator with the environment of IT convergency. In this paper, we propose the information and control system of elevator based on media streaming service that is extended from the existing control system of an elevator. There is the service environments based on Internet for architecture of information communication in the framework of the suggested streaming service. We use this framework to operate and integrate the various services of elevator system. And also, we so apply to the user requirements easily that we can construct the smart elevator environment by convergence home network and various electronic devices based on IT.

A Study on the Speed Control of PMSM for Elevator Drive (엘리베이터구동용 영구자석형 동기전동기의 속도제어에 관한 연구)

  • Yu J.S.;Kim L.H.;Choi G.J.;Yoon K.C.;Jung M.T.;Kim Y.C.;Lee S.S.;Won C.Y.
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.461-466
    • /
    • 2003
  • This paper presents the speed control of the surface-mounted permanent-magnet synchronous motors (SMPMSM) for the elevator drive. The elevator motor needs to be a compact and slim type. Essentially, the proposed scheme uses a vector control algorithm for a speed and torque control. This system is implemented using a high speed 32-bit DSP (TMS320C31-50), a high-integrated logic device FPGA (EPF10K10-Tl144-3) to design compactly and Inexpensively The proposed scheme is verified through digital simulation and experiments for a three-phase 13.3kW SMPMSM as a MRL(MachineRoomless) elevator motor ill the laboratory. Finally, experiment of the test tower was performed with a 48kW PWM converter-inverter system for a high- speed elevator .

  • PDF