• Title/Summary/Keyword: Electrostatic removal

Search Result 134, Processing Time 0.024 seconds

Numerical and Experimental Study on the Increase of Removal Efficiency of SO2 in a Laboratory Scale Electrostatic Spray Drying Absorber (실험실 규모 정전기 분무형 반건식 세정기의 SO2 제거효율 향상에 대한 계산 및 실험적 연구)

  • Byun, Young-Cheol;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.8
    • /
    • pp.1111-1120
    • /
    • 1998
  • Spray Drying Absorber(SDA) system, where the combustion product gas is mixed with atomized limestone-slurry droplets and then the chemical reaction of $SO_2$ with alkaline components of the liquid droplets forms sulfates, has been widely used to eliminate $SO_2$ gas from coal fired power plants and waste incinerators. Liquid atomization is necessary because it can maximize the reaction efficiency by increasing the total surface area and dispersion angle of the alkaline components. First, numerical calculations using FLUENT are carried out to investigate $SO_2$ concentration distribution and thus to calculate $SO_2$ removal efficiency. So to attain the optimized spray conditions, then an electrostatic spraying system is set up and spray visualization is performed to show the effect of an electric field on overall droplet size. Next, the effect of an electric field on the concentrations of $SO_2$ is experimentally examined. Field strength is varied from -10 kV to 10 kV and configurations of conduction charging and induction charging are utilized. Consequently, the electrostatic removal efficiency of 501 increases about 30% with the applied voltage of ${\pm}10kV$ but is independent of polarity of the applied voltage. It Is also found that the conduction charging configuration results in higher efficiency of $SO_2$ removal that the induction charging configuration. Finally, the effect of slurry temperature on $SO_2$ removal is studied. The temperature influences on the electrostatic removal efficiency of $SO_2$.

Particle removal characteristics of high-velocity electrostatic mist eliminator (정전 고속 미스트 엘리미네이터의 포집 효율 특성)

  • Kim, Jin-seon;Kim, Hak-Joon;Han, Bangwoo;Woo, Chang Gyu;Kim, Yong-Jin;Lee, Sangrin;Moon, Sangchul
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.121-133
    • /
    • 2018
  • In this study, we developed a flat-plate type wet electrostatic precipitator that generates stable corona discharge compared to wire type discharge electrode. In order to compare the particle removal efficiency according to the shape of the discharge electrode such as the variation of the horizontal and vertical distance between spiked edges, and the variation of the height of discharge pin support were tested. As a result, when the horizontal distance between spiked edges was increased up to 36 mm, the vertical distance between spiked edges was increased up to 54 mm, and the height of the discharge pin support was increased up to 76 mm, the removal efficiency of PM10 was maintained at approximate 60.0%. Furthermore, the removal efficiency of particles over $5{\mu}m$ was about 80% or more. When the flow rate was 4 m/s, the gap between collection plates was 60 mm, and -14 kV was applied to the discharge electrode. The particle removal efficiency of the flat-plate type electrostatic precipitator was maintained when the horizontal and vertical distance between spiked edges, and the height of the discharge pin support was below a certain level. Those variables may be the important design factors for the shape of the discharge electrode. Therefore, when designing the electrostatic precipitator with multiple channels, the horizontal and vertical distance between spiked edges, and the height of discharge pin support must be selected in consideration of the weight of the discharge electrode and the processing cost.

An Experiment on Particle Collection and Gas Removal in a 2-Stage Electrostatic Wet Scrubber (2단 정전식 세정집진기의 집진 및 가스제거 특성)

  • Yeo, Kuk-Hyun;Yoo, Kyung-Hoon;Son, Seung-Woo;Kim, Yoon-Shin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.745-752
    • /
    • 2006
  • DOS and NaCl aerosol particles were used to determine collection efficiencies of a 2-stage electrostatic wet scrubber with respect to particle size. The DOS and NaCl aerosols have geometric mean diameters of 0.1-3.0 urn, geometric standard deviations of $1.1{\sim}1.8$ and total number concentrations of $450{\sim}2,400\;particles/cm^3$. The tested operating variables for the electrostatic wet scrubber included air velocity and water injection rate. It was shown from the experimental results that particle collection efficiencies increased in the submicron particle size range when different polarities were applied on the water nozzle and corona wire, respectively. This increase in the collection efficiency is attributed to strong electrostatic attraction between the negative water droplets and positive submicron particles. The collection efficiencies also increased when water injection rate was increased or air velocity was decreased. Meanwhile, the pressure drop across the wet scrubber decreased by 90% compared with the existing mechanical wet scrubber. Finally, ammonia gas was used to determine gas removal efficiencies. It was observed that the gas removal efficiencies increased when the air velocity was decreased or the water injection rate was increased.

Gas and particle removal characteristics of a novel electrostatic precipitation type air cleaner using an activated carbon filter as an electrode (활성탄 섬유 필터를 전극으로 활용한 정전 방식의 공기정화장치의 가스 및 입자 제거 특성 분석)

  • Lim, Gi-Taek;Kim, Yong-Jin;Han, Bangwoo;Woo, Chang Gyu;Shin, Weon Gyu;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.14 no.1
    • /
    • pp.9-16
    • /
    • 2018
  • We have developed an electrostatic precipitation (ESP) type air cleaner for indoor air quality and investigated its performances regarding CADR (Clean air delivery rate), single-pass efficiency and gas removal efficiency. The ESP air cleaner used an ACF (Activated carbon fiber) filter for gas removal and the ACF as a high voltage electrode for particle removal. The ESP air cleaner was tested in a chamber with the volume of $1m^3$ regarding CADR and gas removal efficiency. The applied CADR area of the ESP was $1.8m^2$. Gas removal efficiency was tested with 3 gases (Acetaldehyde, Acetic acid, Ammonia). As the results of the gas removal efficiency, the ESP air cleaner shows the removal efficiencies of 90, 98 and 85% for acetaldehyde, acetic acid and ammonia, respectively.

Generation Characteristics of Ozone and NOx and Particle Removal in the Electrostatic Precipitators (코로나 방전 방식에 따른 전기집진기의 오존, NOx 발생 및 입자제거 특성)

  • Noh, Kwang-Chul;Lee, Young-Ho;Oh, Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1442-1449
    • /
    • 2003
  • We investigated the amount of the toxic gases emitted from the Electrostatic Precipitators(ESPs), which are currently used as the indoor air cleaners. The existing wire-to-plate(WTP) and neddle-to-plate(NTP) types of ESP designs are considered as the experimental corona dischargers. Using the voltage, the polarity of wire, the number of needles of NTP as the input variables, we studied the generation characteristics of ozone and $NO_{x}$ and the particle removal efficiency in the ESPs. As the results, we found out that the concentration of ozone, $NO_{2}$ and $NO_{x}$ is increased with increasing the voltage and the number of needles, but the amount of NO is decreased. And we observed that the generation rates of ozone and $NO_{x}$ are mainly related with the corona region through the photographs. Finally the experimental results showed that the particle removal efficiency of ESP with WTP type charger is more superior to that with NTP type chargers at the same voltage.

Study on Effect of KCl Concentration on Removal Rate in Chemical Mechanical Polishing of Sapphire (염화칼륨 농도에 따른 사파이어 기판 CMP에 관한 연구)

  • Park, Chuljin;Kim, Hyoungjae;Jeong, Haedo
    • Tribology and Lubricants
    • /
    • v.33 no.5
    • /
    • pp.228-233
    • /
    • 2017
  • Chemical Mechanical Polishing of chemically stable sapphire substrates is dominantly affected by the mechanical processing of abrasives, in terms of the material removal rate. In this study, we investigated the effect of electrostatic force between the abrasives and substrate, on the polishing. If potassium chloride (KCl) is added to slurry, water molecules are decomposed into $H^+$ and $OH^-$ ions, and the amount of ions in the slurry changes. The zeta potential of the abrasives decreases with an increase in the amount of $H^+$ ions in the stern layer; consequently, the electrostatic force between the abrasives and substrate decreases. The change in zeta potential of abrasives in the slurry is affected by the slurry pH. In acidic zones, the amount of ions bound to the abrasives increases if the amount of $H^+$ ions is increased by adding KCl. However, in basic zones, there is no change in the corresponding amount. In acidic zones, zeta potential decreases as molar concentration of potassium increases; however, it does not change significantly in basic zones. The removal rate tends to decrease with increase in molar amount of potassium in acidic zones, where zeta potential changes significantly. However, in basic zones, the removal rate does not change with zeta potential. The tendencies of zeta potential and that of the frictional force generated during polishing show strong correlation. Through experiments, it is confirmed that the contact probability of abrasives changes according to the electrostatic force generated between the abrasives and substrate, and variation in removal rate.

Selective removal of cationic dye pollutants using coal ash-derived zeolite/zinc adsorbents

  • Chatchai Rodwihok;Mayulee Suwannakaew;Sang Woo Han;Siyu Chen;Duangmanee Wongratanaphisan;Han S. Kim
    • Membrane and Water Treatment
    • /
    • v.14 no.3
    • /
    • pp.121-128
    • /
    • 2023
  • This study introduces a NaOH/Zn-assisted hydrothermal method for the synthesis of zeolites derived from coal ash (CA). A zeolite/Zn adsorbent is successfully prepared by the activation of CA with NaOH and Zn; it is characterized by a high surface area and a negative surface charge.Methylene blue (MB) and methyl orange (MO) are selected as dye pollutants, and their adsorption onto the zeolite/Zn adsorbent is investigated. Results show the high adsorption capacities of MB and MO and that the negative surface charge facilitates electrostatic interactions between the adsorbates and adsorbents. The zeolite/Zn adsorbents shows the selective adsorption of positively charged dye MB via electrostatic interactions between the =NH+ group (positive dipole) and the oxygen functional group of the adsorbents (negative dipole). The selectivity for the positively charged dye is sufficiently high, with the removal efficiency reaching 99.41% within 10 min. By contrast, the negatively charged dye MO exhibits negligible absorption. These findings confirm the role of electrostatic interactions in the adsorption of MB, in addition to the effect of a large surface area. The results of this study are expected to facilitate the development of simple, eco-friendly, and cost-effective zeolite-based adsorptive composites from CA residuals for the selective removal of dye pollutants from CA waste.

Removal characteristics of submicron particles with electrostatic precipitator under $CO_2$ rich condition ($CO_2$ 농후 조건에서 전기집진장치의 Submicron 입자 제거 특성)

  • Kim, Hak-Joon;Han, Bang-Woo;Song, Dong-Keun;Jeong, Sang-Hyun;Won, Jong-Oung;Kim, Yong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2116-2121
    • /
    • 2008
  • Removal of particles at rich $CO_2$ condition has been important in the gas cleaning for $CO_2$ capture in Oxy-fuel combustion. Electrostatic precipitators (ESPs) have been widely used to remove particles in exhaust gases from present air combustion. However, few studies on characteristics of ESPs under a $CO_2$ rich gas condition have been conducted. In this study, we investigated integration of electrostatic precipitators (ESP) for removing submicron particles along with corona discharge characteristics and collection efficiency of submicron particles at $CO_2$ rich condition. The overall performance of ESP is represented by collection efficiency as function of energy consumption. The experiment results showed that higher the concentration of $CO_2$ gas, the corona discharge currents were lower at the same applied voltages and the spark over occurred at lower voltages, and the collection efficiency of submicron particles under 50, 80% $CO_2$ conditions was much lower than that under 100% Air.

  • PDF

An Electrostatic Diesel Particulate Filtration System for Removal of Fine Particulate Matters from Marine Diesel Engines (선박 디젤엔진 배출 미세먼지 저감을 위한 정전 여과 매연 집진기 개발에 관한 연구)

  • Younghun Kim;Gunhee Lee;Kee-Jung Hong;Yong-Jin Kim;Hak-Jun Kim;Inyong Park;Bangwoo Han
    • Particle and aerosol research
    • /
    • v.19 no.4
    • /
    • pp.101-110
    • /
    • 2023
  • In order to reduce particulate matters (PM) from marine diesel engines, we developed novel electrostatic diesel particulate matter filtration system. Electrostatic diesel particulate filtration (DPF) system consists of electrostatic charger and filtration part. The electrostatic charger and filtration part are composed of a metal discharge electrode and a metal fiber filter (porosity: 68.1-86.1%), respectively. In the electrostatic charger part, diesel soot particles are reduced by electrostatic force. The filtration part after electrostatic charger part reduces diesel soot particles through inertial and diffusion forces. The filtration efficiency of electrostatic DPF system was examined through the experiments using engine dynamometer system (300 kW) and ship (200 kW). The PM reduction efficiencies due to inertial and electrostatic forces showed about 70-75% and 80-90%, respectively, according to the RPM of the engine. The differential pressure of the electrostatic DPF system applied to the ship was about 1-9 mbar, which was less than the allowable differential pressure for ship engines in South Korea (100 mbar). The results show that the electrostatic DPF system is suitable for application to the PM reduction emitted from ships.

Electrostatic Characteristics of the Washer-dryer Combination under Various Drying Conditions (건조 일체형 드럼세탁기의 건조 조건에 따른 정전기 특성)

  • Chung Seung-Eun;Park Chung-Hee;Yun Chang-Sang
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.5 s.153
    • /
    • pp.753-761
    • /
    • 2006
  • This paper suggests the optimal conditions for the laundry to prevent from the electrostatic charge by the evaluation of the electrostatic characteristics in the full process of washing and drying. Cotton, nylon, and polyester fabrics were used as test washing specimens. Detergent and softener were used under the standard washing cycle, and then the electrostatic characteristics of laundry were measured. The results showed that the moisture regain decreased and the electrostatic charge increased with the drying time. It was observed that the specimen fabrics were already dried up before the standard drying cycle was finished. Consequently, the excessive drying caused a generation of electrostatic charge due to the removal of the trace of moisture remaining and the excessive friction. Especially, the softener played an important role to prevent from a generation of electrostatic charge, whose insertion was more effective in the drying than in the rinsing process. It was also shown that the electrostatic charge could be decreased by drying the fabrics of one kind. On the other hand, for drying the mixed kinds of fabrics, the electrostatic charge increased remarkably. Therefore we suggest that the laundry be classified according to the kinds of fiber, and then be washed and dried before excessive drying to reduce electrostatic charge And further, a proper use of softener is effective to reduce electrostatic charge.