ESD Protection Circuits with Low-Voltage Triggered SCR for RF Applications

  • 김산홍;박재영;김택수
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.24-25
    • /
    • 2008
  • An Electrostatic discharge (ESD) protection has been a very important reliability issue in microelectronics, especially for RF (Radio Frequency) integrated circuits (ICs). This paper reviews design and analysis of on-chip ESD (electrostatic discharge) protection circuits for RF applications. Key issues in RF ESD protection, design methods, and RF ESD protection solutions are discussed.

  • PDF

정전기 방전에 의한 전자계 복사의 특성 해석 (Property analysis of electromagnetic fields radiated by electrostatic discharge)

  • 강인호
    • 전자공학회논문지D
    • /
    • 제34D권12호
    • /
    • pp.1-7
    • /
    • 1997
  • Serious troubles may occur in electromagnetic equipments due to electrostatic discharge (ESD). The number of the damaging incidents are significantly increasing with the increased use of integrated semiconductor elements with loer operation pwoer. In order to examine the phenomena theoretically, this paper anlyzes properties of the transient electromagnetic fields rdiated by ESD. A new model is presented using the Rompe-weizel formula for the spark resistance. The numerical results of ESD fields are compared with the experimental data that were given by wilson-Ma.

  • PDF

분진운의 최소점화에너지에 대한 정전기 방전회로의 매개변수 영향 (Influence of Electrostatic Discharge Circuit Parameters on the Minimum Ignition Energy of Suspended Dust Clouds)

  • 문균태;정재희;미주키 야마구마;최광석
    • 한국안전학회지
    • /
    • 제25권5호
    • /
    • pp.22-26
    • /
    • 2010
  • The ignitability(minimum ignition energy, MIE) of a suspended dust clouds is very important aspect of technical safety indices. This paper reported the experimental results dealing with the influence of discharge circuit on the MIE of a suspended dust clouds. The movement of a suspended dust clouds was also observed with the high speed camera. The Hartmann vertical-tube apparatus(MIKE-3) described in the international standard of IEC and Polypropylene (PP, 50% volume-average, D50: $761{\mu}m$) resin powders were used in this experiment. The following results were obtained: (1) the MIE of a suspended PP powder depended markedly on the discharge circuit; in other words, when a resistor was connected in series with the discharge sparking circuit(RC), the lowest value(31mJ) of MIE was obtained for a suspended PP powder comparison with the other circuits(C circuit; 370mJ or LC circuit; 71mJ). (2) the discharge duration time is more important than other factors with regard to MIE of a suspended PP powder.

광폭 전기집진기의 집전특성에 관한 연구 - I. 집진판 간격과 방전극의 영향 -

  • 김용진;하병길;정상현;홍원석;여석준;유주식
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.939-946
    • /
    • 2001
  • This study investigates the electrical and collection characteristics of a wide plate spacing electrostatic precipitator (ESP), using a pilot-scale one. Electrical operating characteristics and collection efficiency were measured for various shapes of discharge electrodes. The collection plate spacing ranged from 300 to 550 mm. Results of electrical characteristic and collection efficiency tests as a function of collection plate spacing, discharge electrode type, applied voltage, and particle diameter were obtained. Increasing the collection plate pitch and altering the corona electrode geometry was found to increase the collection efficiencies without increasing input power requirement. The best efficiency is achieved for the discharge electrode of twisted pin type.

  • PDF

나선 스파이크 전기집진기 내 유동 및 집진 현상에 대한 전기수력학 수치해석 연구 (A NUMERICAL ANALYSIS ON ELECTROHYDRODYNAMICS (EHD) OF THE FLOW AND THE COLLECTION MECHANISMS INSIDE AN ELECTROSTATIC PRECIPITATOR WITH A SPIRAL SPIKE ELECTRODE)

  • 이상혁;허남건
    • 한국전산유체공학회지
    • /
    • 제13권4호
    • /
    • pp.58-65
    • /
    • 2008
  • In the present study, a numerical analysis on electrohydrodynamics (EHD) of the flow and the collection mechanisms inside a electrostatic precipitator with a spiral spike electrode were investigated. The phenomena of the electrostatic precipitator include complex interactions between the electric field, the fluid flow and the particle motion. To validate the numerical method, the numerical computation for the electric field of a simple wire-pipe type electrostatic system having an analytic solution were performed. Using this numerical method, the electric field of the spiked electrostatic precipitator was simulated. And the fluid flow and the particle motion inside the spiked electrostatic precipitator were numerically analyzed.

전기집진기 내 유동 및 집진 현상에 대한 전기수력학 수치해석 연구 (A NUMERICAL ANALYSIS ON ELECTROHYDRODYNAMICS (EHD) OF THE FLOW AND THE COLLECTION MECHANISMS INSIDE A ELECTROSTATIC PRECIPITATOR)

  • 이상혁;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.276-282
    • /
    • 2008
  • In the present study, a numerical analysis on electrohydrodynamics (EHD) of the flow and the collection mechanism inside a electrostatic precipitator were investigated. The phenomena of the electrostatic precipitator include complex interactions between the electric field, the fluid flow and the particle motion. To validate the numerical method, the numerical computation for the electric field of a simple wire-pipe type electrostatic system having an analytic solution were performed. Using this numerical method, the electric field of the spiked electrostatic precipitator was simulated. And the fluid flow and the particle motion inside the spiked electrostatic precipitator were numerically analyzed.

  • PDF

전기집진기 내 유동 및 집진 현상에 대한 전기수력학 수치해석 연구 (A NUMERICAL ANALYSIS ON ELECTROHYDRODYNAMICS (EHD) OF THE FLOW AND THE COLLECTION MECHANISMS INSIDE A ELECTROSTATIC PRECIPITATOR)

  • 이상혁;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년 추계학술대회논문집
    • /
    • pp.276-282
    • /
    • 2008
  • In the present study, a numerical analysis on electrohydrodynamics (EHD) of the flow and the collection mechanism inside a electrostatic precipitator were investigated. The phenomena of the electrostatic precipitator include complex interactions between the electric field, the fluid flow and the particle motion. To validate the numerical method, the numerical computation for the electric field of a simple wire-pipe type electrostatic system having an analytic solution were performed. Using this numerical method, the electric field of the spiked electrostatic precipitator was simulated. And the fluid flow and the particle motion inside the spiked electrostatic precipitator were numerically analyzed.

  • PDF

가스충전소에서 작업복의 정전기 안전관리에 관한 연구 (A Study on the Safety Management of the Electrostatic in Working Clothes at the Gas Station)

  • 이금환;정재희
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.39-44
    • /
    • 2009
  • In order to prevent fire and explosion due to the electrostatic discharge at the Gas Station etc. This result will be applied to standard in the future. Wearing the non-electrostatic removing wear, Charged voltage of human body is 3,980V(MIE is approximately 0.79mJ). There is a possibility of fire explosion because the MIE of LP gas is 0.25mJ. In accordance with using period(whasing times), Charged voltage is shown that propensity is increased. Electrostatic charge amount is upper standard($0.6{\mu}$C) of the hazard of electrostatic removing wear. There is a possibility of fire and explosion. Therefore, countermeasure and management are needed about gas station worker.

대전방지용 Al2O3-SiC 복합세라믹 소결체의 제조 및 특성 (Fabrication and Characterisitics of Al2O3-SiC Ceramic Composites for Electrostatic Discharge Safe Components)

  • 김하늘;오현명;박영조;고재웅;이현권
    • 한국분말재료학회지
    • /
    • 제25권2호
    • /
    • pp.144-150
    • /
    • 2018
  • $Al_2O_3-SiC$ ceramic composites are produced using pressureless sintering, and their plasma resistance, electrical resistance, and mechanical properties are evaluated to confirm their applicability as electrostatic-discharge-safe components for semiconductor devices. Through the addition of Mg and Y nitrate sintering aids, it is confirmed that even if SiC content exceeded 10%, complete densification is possible by pressureless sintering. By the uniform distribution of SiC, the total grain growth is suppressed to about $1{\mu}m$; thus an $Al_2O_3-SiC$ sintered body with a high strength over 600 MPa is obtained. The optimum amount of SiC to satisfy all the desired properties of electrostatic-discharge-safe ceramic components is obtained by finding the correlation between the plasma resistance and the electrical resistivity as a function of SiC amount.

주유소에서 사용하는 휘발유의 정전기 방전으로 인한 점화위험성에 관한 연구 (A Study on Ignition Hazard Caused by Electrostatic Discharge of Gasoline Used in the Gas Station)

  • 문균태;정재희;미주키 야마구마;최광석
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.13-18
    • /
    • 2010
  • To investigate electrostatic ignition hazards of commercial gasoline used in the gas station, experiments were conducted dealing with the minimum ignition energy(MIE) of several kinds of gasoline under the various temperature. The conductivity of gasoline that was required for an accurate risk assessment as well as the MIE were also examined. The solvent ignitability apparatus which can heat up the inside of the vessels up to $210^{\circ}C$ was used in this study. Four kinds of premium gasoline and four kinds of regular gasoline, differing with respect to the companies, were used as test specimens. The following results were obtained: (1) all gasoline specimens were so sensitive that even an electrostatic discharge with a very low energy, such as about 0.5mJ, could ignite them. The ignitability of premium gasoline was constant irrespective of the companies. On the other hand, the ignitability of regular gasoline was variable depending on the company. (2) The MIE of all specimens depended markedly on the temperature; in other words, an increase in temperature decreases the ignition energy value. (3) The conductivity values of all specimens were low. Those must be taken into consideration in electrostatic risk assessment.