• Title/Summary/Keyword: Electrophysiology Study

Search Result 181, Processing Time 0.018 seconds

Evaluation of Patient Exposure Dose during Cardiac Electrophysiology Study under Various Conditions (심장 전기생리학 검사 시 조건 변화에 따른 환자 피폭 선량 평가)

  • Seong-Bhin Koh;Sung-Min Ahn
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.501-508
    • /
    • 2023
  • This study used a adult absorption dose phantom (CIRS model 701-G, USA) made of human equivalent material and the vascular imaging equipment Allura Xper FD 20 (Philips, Netherlands). Optically stimulated luminescent dosimeters (OSLD) were inserted into the anatomical positions corresponding to each organ, and the exposure dose was measured. Dose area product (DAP) and air kerma (AK) measured by the dose meter in the equipment were compared. Continuous imaging was performed at two angles for a total of 20 minutes, with a frame per seconds of 3.75 and 7.5 fps and an FOV of 42 cm, 37 cm, and 31 cm, respectively, under the conditions of fluoflavor I, II, and III, each selected for 5 repetitions. This study was found that selecting a lower fps was the most effective way to reduce patient exposure dose, and adjusting the fluoflavor was a good alternative method for reducing patient exposure dose at high fps. Therefore the method of condition change with the greatest dose reduction effect is to set the minimum FPS and can reduce patient exposure dose according to geometric conditions and fluoflavor characteristics.

Correlation of the 3D-Surface Topography and Cobb's Angle in Scoliotic Patient's (측만증 환자에서 3차원 체표면 영상분석과 Cobb 각의 상관관계)

  • Choi, Eun-Jung;Kim, Tae-Youl
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.3 no.1
    • /
    • pp.61-70
    • /
    • 2005
  • The purpose of study correlation between 3D-surface topography and Cobb angle in scoliotic patients. It would be recognizing possibility of clinical application with 3D-surface topography with scoliosis assessment and correlation analysis of obtained Cobb angle through measured results of surface topography and took X-ray of subjects with scoliosis, which used to 3D-surface topography of laser scan method. A scoliosis subjects 16(males 4, females 12) agreed for study's purport volunteer our study that diagnose the scoliosis through 3D-surface topography and X-ray. The results were as follow: It was shown that the relation of Cobb angle of scoliosis and itemized 3D-surface topography measurement in horizontal view(p<0.01). top difference of cervicothoracic and lumbar in anterior-posterior view(p<0.05), the top difference of thoracic, thoracolumbar(p<0.01). These results suggest that an itemized 3D-surface topography measurement was highly correlated with Cobb angle. It would be a useful diagnosis method and assessment of physical therapy plan.

  • PDF

Iontiophoretic Transdermal Delivery of Triamcinolone Acetonide on Delayed Onset Muscle Soreness (지연성 근육통에 대한 Triamcinolone Acetonide의 이온도입 경피투과)

  • Jung, Dae-In;Kim, Myong-Hoon;Hwang, Tae-Yeun;Yoon, Se-Won;Choi, Eun-Young
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.1 no.1
    • /
    • pp.45-56
    • /
    • 2003
  • This study investigated the effects of triamcinolone acetonide by iontophoretic transdermal drug delivery on anti-inflammatory action into the human which had excentric exercise-induced delayed onset muscle soreness in the non-dominant arm. The degree of anti-inflammation was evaluated creatine posphokinase(CPK) by serum enzyme activity and subjective pain threshold by soreness muscle scale in clinical study. The results Were as follows; 1. In a subjective pain scale, all groups showed non-significant difference but, showed a tendency to decrease numerical value in human. 2. In the serum CPK level, iontophoresis group showed more significant reduction than other groups at 24, 48 and 72 hours. From the results, the iontophoresis with triamcinolone acetonide is more effective than using each groups. The continuous study is needed for many interesting issues of iontophoretic transdermal drug delivery in new future.

  • PDF

The Effects of Swiss Ball Lumbar Stabilization Exercise on the Strength and Flexibility, Balance (스위스 볼을 이용한 요부안정화 운동이 근력과 유연성 및 균형에 미치는 영향)

  • Lee, Dong-Geol;Ahn, Sang-Hyun;Oh, Jin-Kyu;Cho, Nam-Jung
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.7 no.1
    • /
    • pp.35-42
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate the effects of Swiss ball lumbar stabilization exercise on the strength and flexibility, balance for the subjects. 30 university students who aged an average $23.21{\pm}4.41$ years. Methods : The exercise program lasted for 4 weeks with a frequency of 3 times per week within 12 to RPE. The result was analyzed by case study were measured by sit-up for strength, and back muscle strength, and trunk flexion test and trunk extension lifting for flexibility, and also measured by balance test before and during, and after the Swiss ball exercise program. Statistical analysis was performed using SPSS/Win(15.0) version and t-test. Results : By the result of this study, we found that the number of performing sit-up strength was increased, and back muscle strength was increase, and trunk flexion test and trunk extension lifting was increased after the 4 weeks Swiss ball exercise program. Conclusion : These finding indicate that Swiss ball lumbar stabilization exercise using Swiss ball could be beneficial to the subjects. The effect of increasing strength and flexibility, balance was flexibility.

Effect of Exercises on the Cerebral Blood Flow (운동이 뇌 혈류 변화에 미치는 영향)

  • Song, Myung-Soo;Choi, Su-Hee
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.1 no.2
    • /
    • pp.1-9
    • /
    • 2003
  • The purpose of this study was to analyze the effect given to the variable details which disturb the flow of blood in brain artery disease through Aerobic exercises. It chose the subjects of study : 5 persons in an exercise group and 5 persons in a non-exercise group. Peak brain blood velocity, mean velocity, and resistance & artery stricture ratio were measured with TCD, measure machine for brain artery blood flow. The conclusion of the study was as follows: 1. At pre-test of an exercises group and a non-exercise group, PBV, MBV, BRI, ASI of a non-exercise group were showed much lower in the variation of left common carotid artery(LCCA). 2. At post-test of an aerobic exercises group and a non-exercise group, PBV, MBV, BRI, ASI of a non-exercise group were showed just a little decrease ratio but were not significant different in the variation of left common carotid artery(LCCA). Viewing on the base of these result, continuing exercises promote the functional improvement of the heart blood system and were showed the positive variation of artery stricture ratio according to brain blood flow velocity, the pulse and resistance or blood velocity. Therefore programs for prescriptions through aerobic exercises must be developed in many ways.

  • PDF

Effect of Electrical Stimulation Level on Quantitative Sensory Test Induced Erythema by UV Radiation (전기자극수준이 자외선에 의한 홍반의 정량적 감각검사에 미치는 효과)

  • Kim, Su-Hyon;Kim, Hyun-Jin
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.2
    • /
    • pp.1-6
    • /
    • 2012
  • Purpose : This study is to investigate the modulatory effects to the ultraviolet induced erythema of pain processing system. Methods : Thirty six healthy volunteers were divided into none treatment group (n=6), indomethacine group (n=6), subsensory level electrical stimulation group (n=6), sensory level electrical stimulation group (n=6), motor level electrical stimulation group (n=6), noxious level electrical stimulation group (n=6). Subjects were induced erythema for three times minimal erythema dose (MED) at upper arm of dermatome C6 level. Each experimental group had mechanical pain threshold (MPT), electrical pain threshold (EPT), thermal pain threshold (TPT). Results : This study revealed that we observed that pain thresholds were significantly correlated with each other in pain processing system. The effect of electrical stimulation levels evaluates were shown to be significant differences pain control effect in electrical stimulation group (sensory, motor level electrical stimulation groups) more than indomethacine group, subsensory level and control group. Conclusion : In this study, it was found that the effect of ultraviolet induced erythema of pain control by modulatory electrical stimulation.

The Effect of Therapeutic Intervention by Aquatic Physical Therapy on Stroke Patient (수중물리치료를 통한 뇌졸중환자의 치료적 중재효과)

  • Lee, Tae-Han;Kim, Soon-Young;Kim, Jong-Pil;Kang, Eun-Cheol;Lee, Sang-Pyung
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.2
    • /
    • pp.15-21
    • /
    • 2012
  • Purpose : The purpose of this study is to compare the rehabilitation effects of hydrotherapy and Bobath therapy. Methods : The study was performed with patients of hemiparesis caused by cerebral stroke. The participants were divided into two groups based on random sampling method. One group received hydrotherapy while the other received Bobath therapy. Each rehabilitation program lasted 40 minutes a day, 5 days a week, for 6 weeks. Pertinent indicators-Berg's balance scale (BBS), gait parameter, and static balance analysis-were recorded before andafter the programs, as well as every 2 weeks during the rehabilitation programs Results : There was showed a significantly increase of BBS score. Static open and close showed statistically significant in interaction by time and groups. There was significant differences of gait velocity. Conclusion : These findings in this study that the hydrotherapy was effective therapy in improving balance and gait velocity.

The Influence Factor Analysis of Spinal Cord Independence Measure(SCIM) on Walking in Spinal Cord Injury (척수손상환자의 보행에 영향을 주는 SCIM 요인 분석)

  • Jung, Dae-In
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.1
    • /
    • pp.83-92
    • /
    • 2004
  • This study aims to the influenced factor analysis of spinal cord independence measure(SCIM), on walking velocity, walking endurance, time up & go(TUG), and subject characteristics. The subject of this study were 12 persons with incomplete spinal cord injury(ASIA C, D). All subject ambulatory with or without an assistive device. All participants were assessed on SCIM(score), walking velocity(m/s), walking endurance(m) and TUG(s). The data were analyzed using independent t-test and stepwise multiple regression. The results revealed that no statistical difference was noted in subject characteristics among SCIM, walking velocity, walking endurance, TUG(p>0.5). The independence score, breathing-sphincter control and ambulation were important factors in TUG(31.4%). The results suggest that SCIM may be an inappropriate assessment tool to predict gait ability of patient with incomplete spinal cord injury. Further study about gait speed, gait endurance and TUG by change of SCIM is needed using to patient of incomplete spinal cord injury.

  • PDF

The Study of a Newly Designed Sling(MTBSDS) for Hemiplegic Shoulder Subluxation (새로운 팔걸이(MTBSDS)가 편마비환자의 견관절 아탈구에 미치는 효과)

  • Lim, Ho-Yong;Song, Tae-Ho;Yang, Dae-Jung;Park, Seung-Kyu
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.1
    • /
    • pp.71-82
    • /
    • 2004
  • To compare the effectiveness of the hemisling, bobath sling, extension-type sling, and the newly designed Modified Triangular Bobath Sling with Distal Support on a hemiplegic shoulder subluxation. Fourteen hemiplegic patients with shoulder subluxation were evaluated by a simple X-ray with and without the slings and the vertical and horizontal distances on the plain AP views were measurement. The newly designed arm sling was compared in terms of the effects of correction with distal support attached with shoulder saddle sling. The arm sling designed for this study was developed for the purpose of maintaining patients hands in a functional position and performing ROM exercise of the shoulder easily, and prevention or correction to shoulder subluxation. The mean values of the vertical and horizontal distance were compared to determine if there was significant difference of function between the new sling and the conventional slings. The new sling provided the patients with good vertical correction of the subluxation(p<0.05) but did not increase the horizontal distance significantly. These results support the effectiveness of a new sling to decrease subluxation in hemiplegia. Further study on the long term effects or complication of the new sling is recommended.

  • PDF

The Effects of Stabilization Exercise on Muscle Performance according to Bearing Surface (지지면에 따른 안정화 운동이 근수행력에 미치는 영향)

  • Park, Jae-Cheol;Han, Jong-Man;Kim, Yong-Seong;Kim, Yong-Nam
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.1
    • /
    • pp.39-44
    • /
    • 2012
  • Purpose : This study purposed to analyze how dynamic stabilization exercise on an unstable surface, and static stabilization exercise on muscle strength and endurance. Methods : For this study we sampled 9 people for the unstable surface dynamic stabilization exercise group, 9 for the stable surface static stabilization exercise group, and 9 for the control group. In order to examine muscle strength and endurance, we measured changes in the maximal voluntary isometric contraction (MVIC) using a dynamometer before, 3 weeks after, and 6 weeks after the experiment. Results : First, with regard to change in muscle strength, flexion strength showed a significant change in interaction by time (p<0.05). Extension strength showed a significant change in interaction by time (p<0.05). Second, with regard to change in endurance, flexion endurance showed a significant change in interaction by time (p<0.05). Extension endurance showed a significant change in interaction by time (p<0.05). Conclusion : In conclusion, this study confirmed significant changes in interaction between the groups and by time with regard to changes in muscle strength and endurance. These results suggest the potential of surface dynamic stabilization exercise as a clinical intervention.