• Title/Summary/Keyword: Electronic safety

Search Result 1,519, Processing Time 0.035 seconds

Study on the Positioning Method using BLE for Location based AIoT Service (위치 기반 지능형 사물인터넷 서비스를 위한 BLE 측위 방법에 관한 연구)

  • Ho-Deok Jang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.1
    • /
    • pp.25-30
    • /
    • 2024
  • Smart City, a key application area of the AIoT (Artificial Intelligence of Things), provides various services in safety, security, and healthcare sectors through location tracking and location-based services. an IPS (Indoor Positioning System) is required to implement location-based services, and wireless communication technologies such as WiFi, UWB (Ultra-wideband), and BLE (Bluetooth Low Energy) are being applied. BLE, which enables data transmission and reception with low power consumption, can be applied to various IoT devices such as sensors and beacons at a low cost, making it one of the most suitable wireless communication technologies for indoor positioning. BLE utilizes the RSSI (Received Signal Strength Indicator) to estimate the distance, but due to the influence of multipath fading, which causes variations in signal strength, it results in an error of several meters. In this paper, we conducted research on a path loss model that can be applied to BLE IPS for proximity services, and confirmed that optimizing the free space propagation loss coefficient can reduce the distance error between the Tx and Rx devices.

A Study on the Diffusion Factor of e-finance (e-Finance의 확산요인에 관한 연구)

  • Kim, Min-Ho;Song, Chae-Hun;Song, Sun-Yok;Cha, Sun-Kwon
    • International Commerce and Information Review
    • /
    • v.4 no.2
    • /
    • pp.253-277
    • /
    • 2002
  • Nowaday, the advanced technology in information and communication has been leading the dramatic change of transaction paradigm expansion from physical basis to electronic one. As we know, financial services support most of financial exchange between two business parties. So the expansion of electronic transaction paradigm affects to every financial institutions which provide financial services. Thus, financial institutions have accepted e-Finance systems and providing internet financial services to live in the competition. The purpose of this study is to contribute the qualitative enhancement of its customer service, rapid diffusion and accurate strategy establishment for e-Finance industry in the user side. Through the literature review and factor and reliability analysis, this study selects six diffusion factors such as efficiency of perceived e-Finance, reliability and safety of e-Finance in perceived e-Finance itself's characteristic; confidence, technical factors and the customer service quality of e-Finance system in perception on e-Finance System; inclination to innovation in the personal characteristic. According to result of hypothesis verification by using logistics regression analysis, technical factors and the customer service quality of e-Finance system in perception on e-Finance System and inclination to innovation in the personal characteristic gave statistically positive effect to the diffusion decision at the significant level 0.05 and 0.01. However efficiency of perceived e-Finance, reliability and safety of e-Finance in perceived e-Finance itself's characteristic didn't affect to diffusion decision and confidence of e-Finance system in perception on e-Finance System didn't have any statistical significancy. This study can be used as a basic material for the forward empirical study of diffusion factors in the user side and be able to apply to company and government policy making or embodiment, determination for customer service quality degree of financial institutions. But this study has some limitations like didn't touch satisfaction factors and its effect, only deal domestic customers and didn't use multi-regression analysis.

  • PDF

A study on the developmental plan of Alarm Monitoring Service (기계경비의 발전적 대응방안에 관한 연구)

  • Chung, Tae-Hwang;So, Seung-Young
    • Korean Security Journal
    • /
    • no.22
    • /
    • pp.145-168
    • /
    • 2010
  • Since Alarm Monitoring Service was introduced in Korea in 1981, the market has been increasing and is expected to increase continually. Some factors such as the increase of social security need and the change of safety consciousness, increase of persons who live alone could be affected positively on Alarm Monitoring Service industry. As Alarm Monitoring Service come into wide use, the understanding of electronic security service is spread and consumer's demand is difficult, so consideration about new developmental plan is need to respond to the change actively. Electronic security system is consist of various kinds of element, so every element could do their role equally. Alarm Monitoring Service should satisfy consumer's various needs because it is not necessary commodity, also electronic security device could be easily operated and it's appearance has to have a good design. To solve the false alarm problem, detection sensor's improvement should be considered preferentially and development of new type of sensor that operate dissimilarly to replace former sensor is needed. On the other hand, to settle the matter that occurred by response time, security company could explain the limit on Alarm Monitoring System to consumer honestly and ask for an understanding. If consumer could be joined into security activity by security agent's explanation, better security service would be provided with mutual confidence. To save response time the consideration on the introduction of GIS(Global Information System) is needed rather than GPS(Global Positioning System). Although training program for security agents is important, several benefits for security agents should be considered together. The development of new business model is required for preparation against market stagnation and the development of new commodity to secure consumer for housing service rather than commercial facility service. for the purpose of those, new commodity related to home-network system and video surveillance system could be considered, also new added service with network between security company and consumer for a basis is to be considered.

  • PDF

The Development of On-Line Statistics Program for Radiation Oncology (방사선종양학과 On-line 통계처리프로그램의 개발)

  • Kim Yoon-Jong;Lee Dong-Hoon;Ji Young-Hoon;Lee Dong-Han;Jo Chul-Ku;Kim Mi-Sook;Ru Sung-Rul;Hong Seung-Hong
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.369-380
    • /
    • 2001
  • Purpose : By developing on-line statistics program to record the information of radiation oncology to share the information with internet. It is possible to supply basic reference data for administrative plans to improve radiation oncology. Materials and methods : The information of radiation oncology statistics had been collected by paper forms about 52 hospitals in the past. Now, we can input the data by internet web browsers. The statistics program used windows NT 4.0 operation system, Internal Information Server 4.0 (IIS4.0) as a web server and the Microsoft Access MDB. We used Structured Query Language (SQL), Visual Basic, VBScript and JAVAScript to display the statistics according to years and hospitals. Results : This program shows present conditions about man power, research, therapy machines, technics, brachytherapy, clinic statistics, radiation safety management, institution, quality assurance and radioisotopes in radiation oncology department. The database consists of 38 inputs and 6 outputs windows. Statistical output windows can be increased continuously according to user's need. Conclusion : We have developed statistics program to process all of the data in department of radiation oncology for reference information. Users easily could input the data by internet web browsers and share the information.

  • PDF

Analysis of the Inter- and Intra-treatment Isocenter Deviations in Pelvic Radiotherapy With Small Bowel Displacement System (Small Bowel Displacement System을 이용한 골반부 방사선조사에서 치료간 및 치료중 중심점 위치변동에 관한 분석)

  • Kim Moon Kyung;Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Lim Do Hun;Shin Kyung Hwan;Lee Kyu Chan
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.114-119
    • /
    • 2000
  • Purpose : To evaluate the e지ent and frequency of the inter- and intra-treatment isocenter deviations of the whole pelvis radiation field in using small bowel displacement system (SBDS). Methods and Materials : Using electronic portal imaging device (EPID), 302 postero-anterior 232 lateral portal images were prospectively collected from 11 patients who received pelvic radiation therapy (7 with cervix cancer and 4 with rectal cancer). All patients were treated in prone position with SBDS under the lower abdomen. Five metallic fiducial markers were placed on the image detection unit for the recognition of the isocenter and magnification. After aligning the bony landmarks of the EPID images on those of the reference image, the deviations of the isocenter were measured in right-left (RL), cranio-caudal (CC), and PA directions. Results : The mean inter-treatment deviation of the isocenter in each RL, CC, and PA direction was 1.2 mm ($\pm$ 1.6 mm), 1.0 mm ($\pm$3.0 mm), and 0.9 mm ($\pm$4.4 mm), respectively. Inter-treatment isocenter deviations over 5 mm and 10 mm in RL, CC, and PA direction were 2, 12, 24$\%$, and 0, 0, 5$\%$, respectively. Maximal deviation was detected in PA direction, and was 11.5 mm. The mean intratreatment deviation of the isocenter in RL, CC, and PA direction was 0 mm ($\pm$0.9 mm), 0.1 mm ($\pm$ 1.9mm), and 0 mm ($\pm$1.6 mm), respectively. All intra-treatment isocenter deviations over 5 mm in each direction were 0, 1, 1$\pm$, respectively. Conclusions : As the greatest and the most frequent inter-treatment deviation of the isocenter was along the PA direction, it is recommended to put more generous safety margin toward the PA direction on the lateral fields if clinically acceptable in pelvic radiotherapy with SBDD.

  • PDF

Standardization of Identification-number for Processed Food in Food-traceability-system (가공식품에 대한 이력추적관리번호 부여체계의 표준화 방안)

  • Choi, Joon-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.2
    • /
    • pp.194-201
    • /
    • 2012
  • Facing a number of global food-related accidents, the concept and system for food traceability have been designed and introduced in many countries to manage the food-safety risks. To connect and harmonize the various food traceability-information in food traceability system according to the food supply chain, the coding system of identification-number for food-traceability has to be standardized. The GTIN (Global Trade Item Number) barcode system which has been globally standardized and implemented, is reviewed with the mandatory food-labeling regulation in expiration date of processed foods. The integration of GTIN-13 bar-code system for food-traceability is a crucial factor to expand its function in the food-related industrial areas. In this literature, the standard coding system of identification-number for food-traceability is proposed with 20 digit coding number which is combined with GTIN-13 bar-code (13 digit), expiration date (6 digit), and additional classification code (1 digit). This proposed standard coding system for identification-number has a several advantages in application for prohibiting the sale of hazard goods, food-recall, and inquiring food traceability-information. And also, this proposed coding system could enhance the food traceability system by communicating and harmonizing the information with the national network such as UNI-PASS and electronic Tax-invoice system. For the global application, the identification-number for food-traceability needs to be cooperated with the upcoming global standards such as GTIN-128 bar-code and GS1 DataBar.

Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle (마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발)

  • Kim, Jun-tae;Joo, Kyu-tai;Cha, Eun Jong;Kim, Myung-mi;Jeong, Jin-hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.394-402
    • /
    • 2021
  • The entry of an aging society and the extension of human life expectancy, the increasing interest in women's social advancement and men's appearance, and the natural interest in K-culture through media media, while receiving worldwide attention, Focus on K-Bueaty. Recently, looking at the occupation of the medical tourism field, in the case of aesthetic medicine tourism such as molding and dermatology, it has gained popularity not only in Asia such as China and Japan, but also in North America and Europe. The first external confirmation of human aging is the wrinkles on the skin of the face. Clean, wrinkle-free, elastic and healthy skin is a desire of most people. Skin condition and condition such as focused ultrasonic stimulation (HIFU: High Intensity Focused Utrasound) and low frequency, high frequency (RF: Radio Frequency), galvanic therapy using microcurrent, cryotherapy using rapid cooling, etc. Depending on the method of management, the effect of the treatment differs depending on the output and the stimulation site, etc., even in the treatment of medical equipment and beauty equipment using the same mechanism. In this research, in order to develop invasive high-frequency dermatological devices using a large number of beauty medical devices and microneedles of beauty devices, the international standards IEC 60601-2 (standards for individual medical devices) and MFDS (Ministry of) We designed and developed a high-frequency output device in compliance with the high-frequency stimulation standard announced in the Food and Drug Safety (Ministry of Food and Drug Safety). The circuit design consists of an amplifier (AMP: Amplifier) using Class-A Topology and a power supply device using Half-Bridge Topology. As a result of measuring the developed high-frequency output device, an average efficiency of 63.86% was obtained, and the maximum output was measured at 116.7W and 50.67dBm.

Study of Examples for Air Bag Non-deployment Including Rear Collision and Failure Phenomenon by Damage of Control Parts in Vehicle Air Bag (자동차 에어백의 제어부품 불량에 의한 고장현상 및 후방 추돌에 관련된 에어백 미전개에 대한 사례 연구)

  • Lee, Il Kwon;Kim, Young Gyu;Moon, Hak Hook
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.102-106
    • /
    • 2012
  • The purpose of this paper is to study the failure cases in relation to system of Air Bag in vehicle happened in the field. In the first example, it was separated the soldering parts connected the wire pin between air bag module and clock spring of air bag. Whenever the pin shake by the car's vibration, the driver verified the malfunction phenomenon appeared air bag warning lamp on instrument panel in front of driver's seat. in car inside room. The second example, it verified the warning lamp lighting phenomenon of air bag by produced the circuit plate non-contacting of single an element in air bag electronic control unit. The third example, it verified the light of air bag warning indicator lamp by separated with soldering parts connecting inner pin and resistance terminal of seat belt pretensioner using passenger seat. The fourth example, when the passenger car crash a back of truck, the former bumper get jammed under the latter as the roof height of car low less than that. Therefore, the impact of Car's collision verified that don't transfer with body frame of vehicle because of no attachment impact sensor in it.

Systemic review: Herbal Medicines in the Treatment of Osteoarthritis in Pubmed and Chinese Medical Journals (퇴행성관절염(退行性關節炎) 한방치료(韓方治療)에 대(對)한 최근(最新) 연구(硏究) 동향(動向) - 임상연구(臨床硏究) 방법론(方法論)을 중심(中心)으로 -)

  • Seo, Byung-kwan;Ryu, Seong-ryong;Lee, Song-shil;Huh, Jeong-eun;Baek, Yong-hyeon;Lee, Jae-dong;Choi, Do-young;Cho, Yoon-je;Kim, Nam-jae;Park, Dong-suk
    • Journal of Acupuncture Research
    • /
    • v.21 no.3
    • /
    • pp.265-282
    • /
    • 2004
  • Objective : The aim of this study was to review systemically clinical trials on the effectiveness and safety of herbal medicines in the treatment of osteoarthritis. Methods : Computerized literature searches were carried out on seven electronic databases, and hand-searching on some chinese medical journals in library of Kyung Hee Medical Center. Trial data were extracted in a standardized, predefined manner and assessed independently. Results : 1. Thirty reports of clinical trials and two reports of meta-analyses concerning herbal medicine were collected and reviewed. Among these reports three medical herbs were applied as topical medicine and others as internal medicine. 2. The western studies established NSAIDs or placebo as their control group. Five chinese reports established formulated herb pill(Ruanshnagshenjin pill) as their control group and Six did not establish a control group at all. 3. ACR was the most highly used diagnostic criteria in the western studies while the Chinese used their official criteria established by their government or the criteria of their text books. 4. 20 reports chose the Lequesne functional index, SHAQ, WOMAC OA index, AIMS, and their own unique scoring system as the criteria of analysing the effect. Others chose clinical symptoms, articular functions, and lab finding as their criteria. 5. 7 single herbs and 19 formulated herbs were studied. Among the formulated herbs, Achyranthes japonica was studied in 10 of the studies and Angelica gigantis Radix in 8, making them the most often studied herbs among the studies.

  • PDF

Developing the Test Module of LSAM for $Hipass^{PLUS}$ Card System (하이패스플러스카드 시스템을 위한 LSAM시험 및 모듈 개발)

  • Lee Ki-Han;Yoon Hyun-Tak;Kim Jae-Uoong;Lee Seung-Hwan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.3 no.1 s.4
    • /
    • pp.1-12
    • /
    • 2004
  • Recently, the Korea Highway Company is replacing their prepaid plastic cards with a smart card, called $Hipass^{PLUS}$ Card. In order to use $Hipass^{PLUS}$Card in the prepaid payment system, LSAM, which is to store the value into $Hipass^{PLUS}$ Card is needed. LSAM is also responsible to store or retrieve the value from PPSAM. For the safety of Korea Highway electronic payment system, the functionality and security of LSAM should be faultless. This paper developed a test module including the test method, the test checklist, and the test procedure. The test module examines the functionality and security of loading the value from PPSAM to LSAM, retrieving the value from LSAM to PPSAM, and loading the value from LSAM to $Hipass^{PLUS}$ Card. The test module contains the method and the procedure to test the standard items by the test checklists. The test items and test checklists of LSAM was selected under the provision of the specification of Korea Highway Company and ISO standard. The test module evaluates the functionality, the security and the compatibility of LSAM. After the evaluation test of LSAM using the test module, LSAM satisfied the characteristics of the functionality, security, and compatibility.

  • PDF