• Title/Summary/Keyword: Electronic devices

Search Result 4,580, Processing Time 0.038 seconds

A Study on Heat Dissipation Characteristics of PMMA Composite Films with Phase Change Material (상변화물질을 이용한 PMMA 복합필름의 방열 성능 향상에 관한 연구)

  • Kwon, Junhyuk;Yoon, Bumyong;Cho, Seung-hyun;Lee, Stephanie K.;Kim, Hyung-ick;Kim, Donghyun;Park, Kyungui;Suhr, Jonghwan
    • Composites Research
    • /
    • v.30 no.5
    • /
    • pp.288-296
    • /
    • 2017
  • The focus of this study is to experimentally investigate the heat dissipation characteristics of poly (methyl methacrylate) (PMMA) composite films with phase change materials (PCM) to resolve heat build-up problems encountered in various electronic devices. In this study, two different types of phase change materials were used to fabricate the composite films by compression molding method and PCM paste sealing method then compared. It was observed in this study that the heat dissipation capability of PCM/PMMA composite films was remarkably enhanced by applying graphite sheet or graphene film into the composite due to their high thermal conductivity. These PCM/ PMMA composite films were attached on the hot spot inside smart phone and tested its surface temperature change according to time. The heat dissipation capability of PCM/PMMA composite film incorporated smart phone was increased 154% and hybrid PCM/PMMA composite film incorporated smart phone was increased 286% over the reference, respectively.

New techniques for wound management: A systematic review of their role in the management of chronic wounds

  • Bekara, Farid;Vitse, Julian;Fluieraru, Sergiu;Masson, Raphael;De Runz, Antoine;Georgescu, Vera;Bressy, Guillaume;Labbe, Jean Louis;Chaput, Benoit;Herlin, Christian
    • Archives of Plastic Surgery
    • /
    • v.45 no.2
    • /
    • pp.102-110
    • /
    • 2018
  • Debridement is a crucial component of wound management. Recent technologies such as hydrosurgery (Versajet), ultrasound therapy (the MIST therapy device), or plasma-mediated bipolar radio-frequency ablation therapy (Coblation) seem to represent interesting alternatives for wound debridement. The purpose of this systematic review was to describe, evaluate, and compare these three recently developed methods for the management of chronic wounds. In January 2016, an electronic database search was conducted of MEDLINE, PubMed Central, and Embase for articles concerning these three innovative methods for the management of chronic wounds. A total of 389 references were identified by our search strategy, and 15 articles were included. We extracted data regarding the number and age of patients, indications, operating time, number of procedures, costs, wound healing time, decrease in exudation, perioperative blood loss, bacterial load, and the occurrence of complications. The 15 articles included studies that involved 563 patients who underwent hydrosurgery (7 studies), ultrasound therapy (6 studies), or Coblation (2 studies). Six randomized controlled trials were included that compared the use of a scalpel or curette to hydrosurgery (2 studies) or ultrasound therapy (6 studies). Hydrosurgery, in addition to being a very precise and selective tool, allows significantly faster debridement. Ultrasound therapy provides a significant reduction of exudation, and improves the wound healing time. No comparative study dedicated to Coblation was identified. Despite the obvious clinical interest of the topic, our review of the current literature revealed a lack of prospective randomized studies comparing these devices with each other or with standard techniques, particularly for Coblation and hydrosurgery.

Design and Analysis of a 12 V PWM Boost DC-DC Converter for Smart Device Applications (스마트기기를 위한 12 V 승압형 PWM DC-DC 변환기 설계 및 특성해석)

  • Na, Jae-Hun;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.239-245
    • /
    • 2016
  • In this study, a 12 V PWM boost converter was designed with the optimal values of the external components of the power stage was well as the compensation stage for smart electronic applications powered by a battery device. The 12 V boost PWM converter consisted of several passive elements, such as a resistor, inductor and capacitor with a diode, power MOS switch and control IC chip for the control PWM signal. The devices of the power stage and compensation stage were designed to maintain stable operation under a range of load conditions as well as achieving the highest power efficiency. The results of this study were first verified by a simulation in SPICE from calculations of the values of major external elements comprising the converter. The design was also implemented on the prototype PCBboard using commercial IC LM3481 from Texas Instruments, which has a nominal output voltage of 12 V. The output voltage, ripple voltage, and load regulation with the line regulation were measured using a digital oscilloscope, DMM tester, and DC power supply. By configuring the converter under the same conditions as in the circuit simulation, the experimental results matched the simulation results.

Microwave Dielectric Properties of La2O3-B2O3-TiO2 Glass-Ceramic and BaNd2Ti5O14Ceramic System for LTCC Application (저온동시소성(LTCC)을 위한 결정화 유리(La2O3-B2O3-TiO2계)와 BaNd2Ti5O14 세라믹을 이용한 마이크로파 유전체 특성)

  • 황성진;김유진;김형순
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.8
    • /
    • pp.599-604
    • /
    • 2004
  • The LTCCs (Low-Temperature Co-fired Ceramics) are very important for electronic industry to build smaller RF modules and to fulfill the necessity for miniaturization of devices in wireless communication industry. The dielectric materials with sintering temperature $T_{sint}$<90$0^{\circ}C$ are required. In this study, BaO-N $d_2$ $O_3$-Ti $O_2$ (BNT : 20∼40 wt%) for ceramic materials and L $a_2$ $O_3$- $B_2$ $O_3$-Ti $O_2$ (LBT : 80∼60 wt%) for crystallizable glasses were used. The glass/ceramic composites were investigated for sintering behavior, phase evaluation, densities, interface reaction and microwave dielectric properties. It was found that the addition LBT glass frist significantly lowered the sintering temperature to below 90$0^{\circ}C$ and the densification with increasing addition LBT glass frist developed rapidly which was meant to be namely 90% of relative density. The sintered bodies ekhibited applicable dielectric properties, namely 15 for $\varepsilon$$_{r}$,, 10000 GHz for Q* $f_{0}$. The results suggest that the composites have good potential as a new candidate for LTCC materials.

A Study on Manufacturing Method of High Performance Smart EMW Absorber with Heat Radiating Function and Its Prospects (방열 기능형 고성능 스마트 전파흡수체 제조 방법 개발 및 전망)

  • Kim, Dong Il;Jeon, Yong Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.10
    • /
    • pp.841-850
    • /
    • 2015
  • With the rapid progress of electronics and radio communication technology, human enjoys greater freedom in information communication. However, EMW(Electro-Magnetic Wave) environments have become more complicate and difficult to control. Thus, international organizations, such as the American National Standard Institution(ANSI), Federal Communications Commission(FCC), the Comite Internationale Special des Perturbations Radio Electrique(CISPR), etc, have provided standard for controlling the EM wave environments and for the countermeasure of the electromagnetic compatibility(EMC). In this paper, fabrication of the smart EMW absorber which has heat radiating function and high performance absorption abilities were suggested. Furthermore, we prospected future smart EMW absorbers. The designed smart EMW absorber is fabricated following process. Firstly, we applied high temperature heat treated to a mixture of Iron-oxide($Fe_2O_3$) and ceramics. Secondly, we applied low temperature heat treated to the mixture of heat treated material and a carbon material. Lastly, we made apertures on the absorber. The designed smart EM wave absorber has the absorption ability of more than 20 dB from 2 GHz to 2.45 GHz band, respectively. Thus, it is respected that these results can be applied as various EMC devices in electronic, communication, and controlling systems.

A Study on the Electromigration Characteristics in Ag, Cu, Au, Al Thin Films (Ag, Cu, Au, Al 박막에서 엘렉트로마이그레이션 특성에 관한 연구)

  • Kim, Jin-Young
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.89-96
    • /
    • 2006
  • Recent ULSI and multilevel structure trends in microelectronic devices minimize the line width down to less than $0.25{\mu}m$, which results in high current densities in thin film interconnections. Under high current densities, an EM(electromigration) induced failure becomes one of the critical problems in a microelectronic device. This study is to improve thin film interconnection materials by investigating the EM characteristics in Ag, Cu, Au, and Al thin films, etc. EM resistance characteristics of Ag, Cu, Au, and Al thin films with high electrical conductivities were investigated by measuring the activation energies from the TTF (Time-to-Failure) analysis. Optical microscope and XPS (X-ray photoelectron spectroscopy) analysis were used for the failure analysis in thin films. Cu thin films showed relatively high activation energy for the electromigration. Thus Cu thin films may be potentially good candidate for the next choice of advanced thin film interconnection materials where high current density and good EM resitance are required. Passivated Al thin films showed the increased MTF(Mean-time-to-Failure) values, that is, the increased EM resistance characteristics due to the dielectric passivation effects at the interface between the dielectric overlayer and the thin film interconnection materials.

Clinical Experience of Continuous Epidural Analgesia Using Baxter $Infusor^{(R)}$ (Baxter $Infusor^{(R)}$를 이용한 경막외 진통제 지속 주입)

  • Bae, Sang-Chull;Lee, Jang-Won;Kim, Ill-Ho;Song, Hoo-Bin;Park, Wook;Kim, Sung-Yell
    • The Korean Journal of Pain
    • /
    • v.4 no.2
    • /
    • pp.127-132
    • /
    • 1991
  • Recently a non-electronic, disposable and portable infusor(Baxter infusor with patient control module, Baxter health care Co., Deerfield IL 60015 USA: BI $\bar{c}$ PCM) has been developed that will deliver both a continuous drug infusion as well as allow the patient to deliver extra doses of medication on a demand basis under predetermined limitation of analgesics. Patients may also not require as high analgesic dose rate to control pain when the acceptable and tolerable level of pain relief can be maintained by this device. From April l99l, we have used a total l93 units of BI $\bar{c}$ PCM. These units consisting of two components which one made by a balloon reservoir(capacity 65 ml, flow rate 0.5 ml/hr) to store medication and to regulate the pump power(490 torr), and another two PCMs to regulate additional analgesic administration by patients demand at intervals of 1S minutes and 60 minutes. The dose administered to the patient can be varied by changing the concentration of the infusate within the balloon reservoir. These devices were utilized for the pain control of 44 patients. These patients were divided into two groups. Twenty seven cases had cancer pain and 17 cases had non-cancer pain. The Touhy needle(No. l8 G.) tip was inserted into the epidural space and was used to guide the catheter to the spinal nerve level corresponding to the most painful area. The device was connected to the opposite site of the catheter tip and was filled with 60 ml of mixture solution such as 0.5% bupivacaine 15 ml, morphine HCl 10 mg, trazodone 10 ml, Tridol 3 ml and normal saline 31 ml were administed as the initial dose. When the initial dose was less effective, the next dose could be varied by increasing the concentration of bupivacaine, by adding more morphine (5~10 mg), and by reducing the volume of normal saline. Using these modules of drug self administration, we experienced the following: 1) Improvement of patient's self titration of analgesic requirement was provided. 2) The patients anxiety with pain recurrence resulting from delays in administering pain control medication was decreased significantly. 3) The working load accompanying with the single bolus injection as the usual method was reduced remarkably. 4) There was urinary retention in 5 cases and pruritus in 4 eases which developed as side effects but respiratory depression and vomiting was not encountered in a single case.

  • PDF

Tunability of Ba(Ti0.92Zr0.08)O3 Polycrystal Grown on Ceramic Seed by Floating Bone Technique (세라믹스 종결정 위에 Floating Zone Technique 법으로 성장한 Ba(Ti0.92Zr0.08)O3 다결정의 Tunability)

  • Hwang, Ho-Byong
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.10 s.269
    • /
    • pp.771-776
    • /
    • 2004
  • [ $Ba(Zr_{0.08}Ti_{0.92})O_3$ ] polycrystal was grown by floating zone technique with two ellipsoidal mirrors using the $8\%$of Zr-modified BZT ceramics as both a feed rod and a seed crystal. In order to study the annealing effect, a part of the grown crystal was sliced and annealed in the oxygen atmosphere at $1,200^{\circ}C$ for 10 h. The dielectric constant and loss at 10 kHz, 100 kHz, and 1 MHz were measured in the temperature range between $-100^{\circ}C$ and $150^{\circ}C$ to investigate the dielectric properties of the grown polycrystal. The electric-field dependence of the dielectric constant at 10 kHz and 100 kHz was studied by measuring the dielectric constants as a function of the biased-electric fields which ran from -15 kV/cm to 15 kV/cm. Due to the effect of annealing in the oxygen atmosphere, the electric-field tunability of dielectric constants increased from $47.5\%$ to 5 to and the figure of merit for this material from 39.6 to 46.4. Since the figure of merit can be increased to more than 46.4 by increasing the maximum value of the biased-electric fields to more than 15 V/cm, this material nay have a possibility for applications in microwave tuning devices at room temperature.

Chimie Douce Reaction to Layered High-$T_c$ Superconducting / Super-ionic Conducting Heterostructures

  • Kim, Young-Il;Hwang, Seong-Ju;Yoo, Han-Ill;Choy, Jin-Ho
    • The Korean Journal of Ceramics
    • /
    • v.4 no.2
    • /
    • pp.95-98
    • /
    • 1998
  • We have developed new type of superconducting-superionic conducting nanohybrids, $Ag_xI_wBi_2Sr_2Ca_{n-1}Cu_nO_y$ (n=1 and 2) by applying the chimie douce reaction to the superconducting Bi-based cuprates. These nanohybrids can be achieved by the stepwise intercalation whereby the $Ag^+$ ion is thermally diffused into the pre-intercalated iodine sublattice of $IBi_2Sr_2Ca_{n-1}Cu_nO_y$. According to the X-ray diffraction analysis, the Ag-I intercalates are found to have an unique heterostructure in which the superionic conducting Ag-I layer and the superconducting $IBi_2Sr_2Ca_{n-1}Cu_nO_y$ layer are regularly interstratified with a remarkable basal increment of ~7.3$\AA$. The systematic XAS studies demonstrate that the intercalation of Ag-I accompanies the charge transfer between host and guest, giving rise to a change in hole concentration of $CuO_2$ layer and to a slight $T_c$ change. The Ag K-edge EXAFS result reveals that the intercalated Ag-I has a $\beta$-AgI-like local structure with distorted tetrahedral symmetry, suggesting a mobile environment for the intercalated $Ag^+$ ion. In fact, from ac impedance analyses, we have found that the Ag-I intercalates possess a fast ionic conductivity ($\sigma_i=10^{-1.4}\sim 10^{-2.6}\Omega^{-1}\textrm{cm}^{-1}\;at\;270^{\circ}C$ with an uniform activation energy ($\DeltaE_a=0.22\pm 0.02$ eV). More interesting finding is that these intercalates exhibit high electronic conducting as well as ionic ones ($t_i$=0.02~0.60) due to their interstratified structure consisting of superionic conducting and superconducting layers. In this respect, these new intercalates are expected to be useful as an electrode material in various electrochemical devices.

  • PDF

Development of Wearable Physical Activity Monitoring System (웨어러블 신체 생체 활동 모니터링 시스템 개발)

  • Park, Eun-Ju;Park, Do-Young
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.1
    • /
    • pp.34-39
    • /
    • 2018
  • Along with the development of ICT technology, wearable devices of various sizes and shapes have been developed. In addition, performance and specifications are rebuilt with IOT fusion products so that they can connect with the current smartphone. This is one of the general-purpose technologies of the 4th industrial revolution, which is spot-lighted with technology that changes the quality and environment of our lives. Along with this, as new technology products combining health care technology increases, various functions are provided to users who need it. Wearable technology is ongoing trend of technology development. It also sells products developed as products in the form of smart watches. At present, various related products are made in various ways, and it is recommended to use the Arduino processor in accordance with the application. In this study, we developed wearable physical activity monitoring system using open source hardware based TinyDuino. TinyDuino is an ultra-compact Arduino compatible board made on the basis of Atmega process Board, and it can be programmed in open source integrated development environment(named Sketch). The physical activity monitoring system of the welfare body can be said to be a great advantage, as a smart u-Healthcare system that can perform daily health management.