• 제목/요약/키워드: Electronic circuit

검색결과 3,005건 처리시간 0.031초

공압구동장치를 위한 PWM 제어기 설계 (Development of a PWM controller for the pneumatic actuation system)

  • 이동우;안병홍;문의준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.7-12
    • /
    • 1989
  • This paper describes the design and development of a PWM electronic controller for a high performance Pneumatic Actuation System. The task includes the design of a closed center valve circuit for minimum gas consumption, the selection of optimum values for key parameters in the PWM circuit, and the design of lag-lead compensation circuit. These were carried out through specific experiments using a prototype pneumatic actuation system. The final performance obtained with the actuation system confirmed the successful design of the developed PWM electronic controller.

  • PDF

중성자 검출을 위한 회로설계 (The Circuit design for Neutron Detection)

  • 김상진;성낙진;김기준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.42-46
    • /
    • 2003
  • In this study, to measure the moisture of compaction, it is designed to use the 2neutron detectors. To perform the optimal design of their circuit, it is planned high voltage generator and voltage stable circuit and they are very suitable for detection demand. Also, it can be count to data calibration excluded count of ripple.

  • PDF

집중 등가회로를 사용한 압전 변압기의 승합비 및 효율 해석 (Voltage Gain and Efficiency Analysis of Piezoelectric Transformer using Lumped constant Equivalent Circuit)

  • 류주현;이용우;윤광희;정희승;정영호;박창엽
    • 한국전기전자재료학회논문지
    • /
    • 제11권10호
    • /
    • pp.849-854
    • /
    • 1998
  • The load characteristics on the voltage gain and efficiency were analyzed using a lumped constant equivalent circuit of the piezoelectric transformer. These analytical results were confirmed by experiments. Theoretical values of voltage gain were nearly constant with experimental ones. However, It was shown that theoretical values of efficiency is higher than experimental ones.

  • PDF

Rosen형 압전 트랜스포머의 집중등가회로를 사용한 승압비 및 효율 해석 (Voltage Gain and Efficiency Ana1ysis of Piezoelectric Transformer using Lumped Constant Equivalent Circuit)

  • 김만성;류주현;정회승;박창엽;정영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.183-189
    • /
    • 1998
  • In this paper, The load characteristics on the voltage gain and efficiency were analyzed sing an lumped constant equivalent circuit of the piezoelectric transformer. These analytical results are confirmed by experiments. Theoretical values of voltage gain were nearly constant with experimental ones. However, It was shown that theoretical values of efficiency had higher values than experimental ones.

  • PDF

Signal Integrity Issues for Reliable Electronic System Designs

  • Eo, Yung-Seon
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2004년도 정기학술대회
    • /
    • pp.37-72
    • /
    • 2004
  • Future Circuit Design means "Unimaginable Intricate Engineering Problems" Thus, Future Circuit Designers may be "Victims" of "Inexorably Complicated Signal Integrity Problems".(omitted)grity Problems".(omitted)tted)

  • PDF

LCD/PDP TV 전원장치용 고전압 구동 IC (High Voltage Driver IC for LCD/PDP TV Power Supply)

  • 송기남;이용안;김형우;김기현;서길수;한석붕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.11-12
    • /
    • 2009
  • In this paper, we propose a high voltage driver IC(HVIC) for LCD and PDP TV power supply. The proposed circuit is included novel a shoot-through protection and a pulse generation circuit for the high voltage driver IC. The proposed circuit has lower variation of dead time and pulse-width about a variation of a process and a supply voltage than a conventional circuit. Especially, the proposed circuit has more excellent pulse-width matching of set and reset signals than the conventional circuit. Also the proposed pulse generation circuit prevent from fault operations using a logic gate. Dead time and pulse-width of the proposed circuit are typical 250 ns, and its variation is maximum 170 ns(68 %) about a variation of a process and a supply voltage. The proposed circuit is designed using $1\;{\mu}m$ 650 V BCD process parameter, and a simulation is carried out using Spectre.

  • PDF

Fault Location for Incomplete-Journey Double-Circuit Transmission Lines on Same Tower Based on Identification of Fault Branch

  • Wang, Shoupeng;Zhao, Dongmei;Shang, Liqun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1754-1763
    • /
    • 2017
  • This paper analyses the characteristics of incomplete-journey double-circuit transmission lines on the same tower formed by single-circuit lines and double-circuit lines, and then presents a fault location algorithm based on identification of fault branch. With the relationship between the three-phase system and the double-circuit line system, a phase-mode transformation matrix for double-circuit lines can be derived. Based on the derived matrix, the double-circuit lines with faults can be decoupled, and then the fault location for an incomplete-journey double-circuit line is achieved by using modal components in the mode domain. The algorithm is divided into two steps. Firstly, the fault branch is identified by comparing the relationships of voltage amplitudes at the bonding point. Then the fault location, on the basis of the identification result, is calculated by using a two-terminal method, and only the fault distance of the actual fault branch can be obtained. There is no limit on synchronization of each terminal sampling data. The results of ATP-EMTP simulation show that the proposed algorithm can be applied within the entire line and can accurately locate faults in different fault types, fault resistances, and fault distances.

개선된 자기소호회로와 아크전압 억제회로를 사용한 유도성 부하의 직류차단 특성 실험 (Experiment on DC Circuit Breaker for Inductive Load by Improved Magnetic Arc-extinguisher and Arc-Attenuation Circuit)

  • 이성민;김효성
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.495-499
    • /
    • 2012
  • Recently, DC distribution systems become hot issues since DC type loads increase rapidly according to the expansion of IT equipment such as computers, servers, and digital devices; DC type loads will cover 50% for all electricity loads in 2020 which was mere 10% in 2000. DC distribution systems are also accelerated by the expansion of renewable power systems since they are easy to be interfaced with DC grids rather than AC grids. However, removing the fault current in DC grids is comparably difficult since the current in DC grids has non zero-crossing point like in AC grids. Thus, developing dedicated DC circuit breakers for DC grids is necessary to get safety for human and electrical facilities. Magnet arc extinguishing method is proper to small size DC circuit breakers. However, simple Magnet arc extinguishing method is not enough to break inductive fault currents. This paper proposed a novel DC circuit breaker against inductive fault current defined by IEEE C37.14-2004 Standard for Low-Voltage DC Power Circuit Breakers Used in Enclosures. The performance of the proposed DC circuit breaker was verified by an experimental circuit breaker test system built in this research.

Rosen형 적층 압전변압기의 등가회로 모델링 (Equivalent Circuit Modeling of Rosen-type Multilayer Piezoelectric Transformer)

  • 신훈범;이용국;유영한;안형근;한득영
    • 한국전기전자재료학회논문지
    • /
    • 제19권12호
    • /
    • pp.1099-1105
    • /
    • 2006
  • In this paper, the equivalent circuit model of a Rosen-type multilayer piezoelectric transformer(MPT) has been proposed based on the Mason's equivalent circuit model and the principle of single layer piezoelectric plate. From the piezoelectric direct and converse effects, the symbolic expressions between the electric inputs and outputs of the MPT have been derived from the equivalent circuit model. A simplified equivalent circuit model of the MPT whose driving part has a single input form has been proposed. The symbolic expressions of the driving part have been derived from the simplified equivalent circuit model and the model was compared with the multi-input equivalent circuit model through the simulation. In the comparisons between the simulation results and the experimental data, output voltage is 630 Vp-p in case of 11-layered MPT and 670 Vp-p for 13-layered MPT over the experiment range. As the load resistance increases, output voltage increases and saturates over $300k{\Omega}$ and the resonant frequency changes from 102 kHz to 103 kHz. The simulation and the experimental results agree well over different load resistances and frequencies.

터치스크린 패널의 회로 모델링 및 분석 (Circuit Modeling and Analysis of Touch Screen Panel)

  • 변기식;민병욱
    • 한국전자파학회논문지
    • /
    • 제25권1호
    • /
    • pp.47-52
    • /
    • 2014
  • 본 논문에서는 대면적 정전식 터치스크린 구동 회로를 설계하기 위하여 여러 가지 터치스크린 패널 구조의 회로 모델을 제안하고, 그 모델의 사용 가능한 주파수 영역을 분석하였다. 터치스크린 패널 한 개 셀의 2D EM 시뮬레이션 결과를 이용한 전체 패널의 circuit 시뮬레이션을 통하여, 23인치 대면적 패널의 가장 긴 채널과 짧은 채널을 5개의 RC 소자의 회로 모델로 근사하였다. EM/circuit 시뮬레이션과 5개 소자의 RC 모델의 S 파라미터 비교를 통해, 5개 소자 모델이 130 kHz까지 10도 이내의 채널 위상 차이를 가지는 것을 확인하였다. 7개 RC 소자를 사용한 모델을 통하여 10도 이내의 채널 위상 차이를 가지는 모델의 주파수 영역을 200 kHz까지 확장하였다.