• Title/Summary/Keyword: Electronic Relay

Search Result 298, Processing Time 0.027 seconds

Implementation of ATE to Maintain Pre-Amplifier of Thermal Imaging System (열상장비 전단증폭부 정비용 ATE의 구현)

  • Park, Jai-Hyo;Kim, Han-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.80-87
    • /
    • 2012
  • We have developed the ATE(Automatic Test Equipment) system for the performance test of pre-amplifier of thermal imaging devices. The device regenerates the electronic signals of photon detection module which is normally in weak energy, for the image signals processing. Previous ATE system was primarily and actively developed in the field of semiconductor devices quality parts inspection. Recently, it has been studied in the field of performance testing of equipment. In the field of thermal performance test equipment, however, it lacks the study of ATE compared to other areas, which causes the maintenance related to the core of military thermal imaging system maintenance to be limited. In this paper, a new study of ATE in the field of thermal imaging system is done. It is designed to be used universally for the ATE system with different types of circuit card of thermal imaging system by adopting matrix relays. Using the developed ATE measuring the pre-amplifier amplitude, an average amplified amplitude of 2.71Vpp was measured which confirms that it is within the range of theoretical analysis and also verifies the good performance of the developed ATE.

The Development of Electronic Transformer(CT/PT) for Intelligent GIS (Intelligent GIS용 전자식 변성기 개발)

  • Kim, M.S.;Jung, J.R.;Kim, J.B.;Song, W.P.;Koh, H.S.;Choi, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1793-1795
    • /
    • 2004
  • 지금까지 변전소나 개폐소에서 전류, 전압을 계측하는 수단으로서 주로 철심과 권선으로 구성되어진 변류기(CT), 계기용 변압기(PT, PD)가 사용되어 왔다 최근, 2차측의 계측기나 보호 Relay의 Digital화가 진전되어, 또한 이것을 Digital Network으로 종합한 Intelligent 변전소의 구축이 검토되어짐에 따라 Digital Network에 대응한 신형 CT, VD가 요구되어 지고 있다. 상기와 같은 요구로 인해 당사에서는 CT는 검출부에 Rogowski Coil을 적용하며 그 후단에 적분기를 설치하였으면, VD는 검출부에 중간 전극을 이용해서 분압하는 방식인 Capacitive Voltage Divider를 사용하고 증폭기를 삽입하여, 각각 요구되는 전압 신호를 얻었다. 이러한 신형 CT/VD의 적용으로 종래의 CT/PT가 차지하는 공간이 필요 없게 되어 컴팩트한 GIS의 구조가 능하게 되어 있다.

  • PDF

Development on Governor of electronic oil pressure type for stt:am turbine of thermal power plant (전자유압식 Governor의 개발 :화력발전소증기 turbine에 있어서의 해외논초)

  • 대한전기학회
    • 전기의세계
    • /
    • v.17 no.2
    • /
    • pp.35-37
    • /
    • 1968
  • 증기 Turbine plant의 제어방식은 점점 더 복잡하게 고도화하고 있으며 원심 또는 유압조속기등 Lever와 유압기구의 조합으로 구성된 기계유압식 Governor 대신에 전자유압식 Governor(Electro-Hydraulic Governor, EHG 일반적으로 광의의 의미로는 전자유압식제어장치 Electro-Hydraulic Control System이라함)의 개발에 주력하고 있으며 본보고서는 이에 대한 시험결과를 기술한 것이다. 본보고서는 산업용(자가발전용) 증기 Turbine의 전자유압식 Governor에 관한 것으로서 기계유압식에서의 복잡한 Lever 기구, Relay 장치등 기계부분의 전자유압화와 고압제어유의 채용및 이에 따르는 각부분의 Module화, Solid State화 및 소형 Unit화에 의하여 취급및 보수가 용이한 고성능의 제어장치를 개발하게 되었다. 특히 미국의 GE사에서 이에 대한 개발이 앞서 있으며 현재 100MW까지 약 30대가 실용화되고 있다고 한다. (이글은 일본화력발전지 1968년 1월 제136호에서 발췌한 글이다.)

  • PDF

Distributed Space-Time Coded Non-Orthogonal DF Protocols with Source Antenna Switching

  • Jin, Xianglan;Yang, Jae-Dong;No, Jong-Seon;Shin, Dong-Joon
    • Journal of Communications and Networks
    • /
    • v.12 no.5
    • /
    • pp.492-498
    • /
    • 2010
  • In this paper, a new distributed space-time coded (DS-TCed) non-orthogonal decode-and-forward (NDF) protocol with source antenna switching (SAS) is proposed, where two antennas associated with each radio frequency chain can be alternatively used in the first and second phases. Several DSTC schemes for the NDF with SAS (NDF-SAS) protocol are proposed and their average pairwise error probability for the error-free source-relay (SR) channel is also derived. The simulation results show that the NDF-SAS protocol achieves larger diversity order than the NDF protocol under the error-free and erroneous SR channels.

Ubiquitous Network and Wireless Embedded System with Intelligent Channel Scheduling Method (지능형 채널 할당 기법의 유비쿼터스 네트워크 및 무선 임베디드 시스템)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1336-1340
    • /
    • 2011
  • In this paper, the efficient prevention of cross talk technique for basically avoiding the confusion problem between the overlapped ubiquitous network of the other object is developed within the same area. The intelligent unified wireless network remote meter reading system of the ubiquitous ZigBee base is developed based on this technology. Therefore, in this paper, each meter reading equipments managed the information of its own adjacent ZigBee channel. The intelligent network system steadily transmitting data a relay was developed based upon this information in each region through the flexible channel conversion technique.

LAN-Based Protective Relaying for Interconnect Protection of Dispersed Generators (LAN을 이용한 분산전원 연계 계통의 보호)

  • Jyung, Tae-Young;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.491-497
    • /
    • 2007
  • As dispersed generators was driven in condition interconnecting with utility, it could cause a variety of new effects to the original distribution system that was running as considered only the one-way power flow. Therefore, the protection devices that is builted in distribution system should be designed to be able to operate with disposing of not only a fault of the generator, but also utility condition. Especially, the fault of the feeder interconnected with Dispersed Generator can cause the islanding phenomenon of open DG(Dispersed Generators). This phenomenon has many problems such as a machinery damage, electricity qualify degradation and a difficulty of the system recovery. In the fault therefore, we must separate Dispersed Generator from the system quickly. In this paper, for the fault classification of the interconnected DG and the outside feeder we judge the fault of the interconnected DG and the outside feeder in HMI through data provided by IED(Intelligent Electronic Device) on the network and decide whether it operates or not by sending the result to each relay.

A Special Protection Scheme Against a Local Low-Voltage Problem and Zone 3 Protection in the KEPCO System

  • Yun, Ki-Seob;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.294-299
    • /
    • 2007
  • This paper presents a special protection scheme, which was established in the KEPCO (Korea Electric Power Corporation) system, against a critically low voltage profile in a part of the system after a double-circuit tower outage. Without establishing the scheme, the outage triggers the operation of a zone 3 relay and trips the component. This sequence of events possibly leads to a blackout of the local system. The scheme consists of an inter-substation communication network using PITR (Protective Integrated Transmitter and Receiver) for acquisition of the substations' data, and under-voltage load shedding devices. This paper describes the procedure for determining the load shedding in the scheme and the experiences of the implementation.

A Design of the Multifunction Bay Controller (다기능 Bay Controller 설계)

  • Lee, Sung-Hwan;Jang, Nak-Won;Woo, Chun-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.146-148
    • /
    • 2007
  • In this paper, we designed the bay control unit that is based on the microprocessors and integrates with the new technology of electrical, electronic, and mechanical fields. Nowadays the customers have required much more integrates multi protection relay, monitoring, control devices and power management for better and easier maintenance, performance, electrical system analysis and communication according to new trend of switchboard. This bay controller supplies those requirements of customers with easy handling and operation. This bay controller provides a graphic display with rear-lit liquid crystal LCD and push buttons as kinds of HMI. This bay controller provides the parameter setting program, various editors and fault recording and analysis program on Windows/95/98/NT/2000/XP for HMI. In addition, this bay controller can be set manually and this manual setting function helps user to interface easily.

  • PDF

Design and Implementation of the ATM Handoff Subsystem Supporting Soft-Handoffs between Mobile Switching Centers

  • Yun Sung-Hyun;Cho Kwang-Moon
    • International Journal of Contents
    • /
    • v.1 no.1
    • /
    • pp.45-49
    • /
    • 2005
  • If the service provider provides mobile service with mobile switching centers that use different handoff message format, the soft-handoff between mobile switching centers is not available and the hard-handoff scheme is used instead. When this occurs, calls are often disconnected or there is an interruption of service. This can be very annoying to a mobile user. We propose the handoff subsystem of the ATM switch which provides the soft-handoff between wireless cells under the control of different MSCs. The proposed handoff subsystem transforms the handoff message format of the source MSC to that of the destination MSC. It also provides efficient routing scheme that distributes handoff packets to balance the traffic load.

  • PDF

Construction of 154kV Intelligent Substation for Verification Test (154kV급 실증시험용 인텔리전트 변전소 구축)

  • Chung, Y.H.;Kim, M.S.;Kim, J.B.;Lee, H.S.;Choi, I.H.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.456-457
    • /
    • 2006
  • We have carried out the construction of the 154kV intelligent substation with KEPRI. The Intelligent substation is built in Gochang testing facility of KEPCO and consists of electronic instruments for GIS(gas insulated switchgear), digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are introduced compared with the instrument transformer of conventional type. Digital control Panel(DCP) replaces the LCP(local control panel) which is drived for mechanical operation. For the monitoring of the condition of GIS and TR, various sensors are used. In this Paper, we mention the synopsis and report the progress state of project.

  • PDF