• Title/Summary/Keyword: Electronic Power Consumption

Search Result 800, Processing Time 0.038 seconds

A Study on Receiving Characteristic Analysis of LED Visible Light Communication System based on Remote Dimming Control (원격 디밍제어 기반 LED 가시광통신 시스템의 수신 특성 분석)

  • Hong, Geun-Bin;Jang, Tae-Su;Kim, Yong-Kab
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.3
    • /
    • pp.153-157
    • /
    • 2011
  • This study to implement properties such as high brightness, reliability, lower power consumption and long lifetime indoor illumination control visible light communication system that with LED used by illuminations. It has probability presently to apply many application field like ubiquitous. To implement such a system, it designs Date to transmit signals to visible light communication transmitter/receiver analyzes the communication performance using computer programming language. This research result Confirmed that it is possible to implement indoor illumination control visible light communication transmitter/receiver consisting of smooth date.

Design and Implementation of Double Down-Converter for Satellite TV (위성 TV용 이중 하향 변환기의 설계 및 제작)

  • Lee, Seung-Dae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.840-845
    • /
    • 2013
  • In this paper, the broadband frequency double down-converter based on LC filter technologies has been designed and implemented, and its performances are introduced. The Designed frequency double down-converter is consisted with a low-noise amplifier, mixer, IF amplifier, LC filter, DC-block capacitor and RF-bypass capacitor. Especially, instead of active devices of a typical converter, the suggested converter designed using passive devices to provide both low-power consumption and low-cost model. As results of the measurement, the implemented frequency double down-converter realizes the broadband performance with the bandwidth of 100MHz (13~113MHz) at the center frequency of 63MHz, and its gain is approximately 40dB.

Attachment of the Air Heat Exchanger for COP Improvement in the Heat Pump (열펌프 성능향상을 위한 공기 열교환기 부착효과)

  • 노정근;송현갑;박용규
    • Journal of Biosystems Engineering
    • /
    • v.27 no.3
    • /
    • pp.235-240
    • /
    • 2002
  • Performance of the heat pump with attaching an air heat exchanger was investigated in the heating condition when the air heat exchanger was worked in the ambient air temperature of -5 to 11$\^{C}$ and air flow rate of 542 to 747 ㎡/h. Performance tests for heating condition were conducted in an experimental room equipped with heat pump. The performance tests were performed in a ambient temperature of -4 ∼ 11$\^{C}$, and room temperature of 4∼22$\^{C}$ respectively. Measured data(temperature, capacity of heat transfer and consumption of electronic power) were analyzed to the efficiency of HEEVA(Heat Exchanger fur the Evaporator), overall heat transfer coefficient and COP of heat pump. The results of inlet temperature for evaporator increased that the temperature was 2 ∼6$\^{C}$, and inlet temperature for condenser decreased that the temperature was 3 ∼ 8$\^{C}$. The results of comparing efficiency of HEEVA for the ratio of heat exchange between hot air and cold air showed that efficiency were considered to 91% because of the ratio of 83∼98%. The results of comparing of COP for the heat pump increased that improvement COP was approximately 0.3∼7.5 than HEEVA had not been operated.

Study on Remote Communication System for Automatic Water Meter Reading using Embedded Processor (임베디드프로세서를 이용한 상수도 자동검침용 원격통신시스템에 관한 연구)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2718-2721
    • /
    • 2011
  • This research developed a remote communication system for automatic water meter reading and charge calculation from the field of a house or apartment complexes within the same district. Developed system was applied to perform measurements of the pulse-sensing technology, the minimum power consumption, temperature compensation, short-range wireless communications technology, the handset and wireless communication capabilities of the DB management embedded software to efficiently control. Through this reading-related tasks that are required in a temporal, material and human resources can be minimized.

Emission Properties of Red OELD with $Znq_2$ and dye (Znq2와 dye에 의한 적색 유기 전계 발광 소자의 발광특성)

  • Cho, M.J.;Choi, W.J.;Park, C.H.;Lim, K.J.;Park, S.K.;Kim, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1466-1468
    • /
    • 2001
  • For the full color organic electro-luminescent device, essentially, red, green, and blue emissions are required. But red emission is not to reach minimum level of practical use 31[lm/W]. In order to optimize color purity and power consumption requirements, it is important for the materials development efforts to search for improvements in red emission effisiency. In this study, the bis(8-oxyquinolino)zinc II ($Znq_2$) were synthesized successfully from zinc chloride($ZnCl_2$) as a initial material. Then, we fabricated red organic electroluminescent device with a dye(DCJTB)-doped and inserted $Znq_2$ between emission layer and cathode layer for increasing EL efficiency. The hole transfer layer is a N,N'-diphenyl-N,N'-bis-(3-methyl phenyl) -1,1'-diphenyl-4.4'-diamine(TPD), and the host material of emission layer is $Znq_2$. For the inserting of $Znq_2$, efficiency increased.

  • PDF

PESQ-Based Selection of Efficient Partial Encryption Set for Compressed Speech

  • Yang, Hae-Yong;Lee, Kyung-Hoon;Lee, Sang-Han;Ko, Sung-Jea
    • ETRI Journal
    • /
    • v.31 no.4
    • /
    • pp.408-418
    • /
    • 2009
  • Adopting an encryption function in voice over Wi-Fi service incurs problems such as additional power consumption and degradation of communication quality. To overcome these problems, a partial encryption (PE) algorithm for compressed speech was recently introduced. However, from the security point of view, the partial encryption sets (PESs) of the conventional PE algorithm still have much room for improvement. This paper proposes a new selection method for finding a smaller PES while maintaining the security level of encrypted speech. The proposed PES selection method employs the perceptual evaluation of the speech quality (PESQ) algorithm to objectively measure the distortion of speech. The proposed method is applied to the ITU-T G.729 speech codec, and content protection capability is verified by a range of tests and a reconstruction attack. The experimental results show that encrypting only 20% of the compressed bitstream is sufficient to effectively hide the entire content of speech.

Development of energy expenditure measurement device based on voice and body activity (음성과 활동량을 이용한 에너지 소모량 측정기기 개발)

  • Im, Jae Joong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.303-309
    • /
    • 2012
  • Energy expenditure values were estimated based on the voice signals and body activities. Voice signals and body activities were obtained using PVDF contact vibration sensor and 3-axis accelerometer, respectively. Vibration caused by voices, activity signals, and actual energy consumption were acquired using data acquisition system and gas analyzer. With the use of power values from the voice signals and weight as independent variables, R-square of 0.918 appeared to show the highest value. For activity outputs, use of signal vector magnitude, body mass index, height, and age as independent variables revealed to provide the highest correlation with actual energy expenditure. Estimation of energy expenditure based on voice and activity provides more accurate results than based on activity only.

Design and Implementation of 30" Geometry PIG

  • Kim, Dong-Kyu;Cho, Sung-Ho;Park, Seoung-Soo;Yoo, Hui-Ryong;Park, Yong-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.629-636
    • /
    • 2003
  • This paper introduces the developed geometry PIG (Pipeline Inspection Gauge), one of several ILI (In-Line Inspection) tools, which provide a full picture of the pipeline from only single pass, and has compact size of the electronic device with not only low power consumption but also rapid response of sensors such as calipers, IMU and odometer. This tool is equipped with the several sensor systems. Caliper sensors measure the pipeline internal diameter, ovality and dent size and shape with high accuracy. The IMU (Inertial Measurement Unit) measures the precise trajectory of the PIG during its traverse of the pipeline. The IMU also provide three-dimensional coordination in space from measurement of inertial acceleration and angular rate. Three odometers mounted on the PIG body provide the distance moved along the line and instantaneous velocity during the PIG run. The datum measured by the sensor systems are stored in on-board solid state memory and magnetic tape devices. There is an electromagnetic transmitter at the back end of the tool, the transmitter enables the inspection operators to keep tracking the tool while it travels through the pipeline. An experiment was fulfilled in pull-rig facility and was adopted from Incheon LT (LNG Terminal) to Namdong GS (Governor Station) line, 13 km length.

New Energy Efficient Clear Channel Assessment for Wireless Network

  • Shin, Soo-Young;Ramachandran, Iyappan;Roy, Sumit
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.8
    • /
    • pp.1404-1422
    • /
    • 2011
  • In this paper, a new clear channel assessment (CCA) method: cascaded-CCA, is proposed. The primary motivation for the proposed approach is to integrate the respective advantages of two standard CCA mechanisms, energy detect and preamble detect, to arrive at a new dual threshold CCA family that can provide greater flexibility towards tuning MAC performance. Cascaded-CCA integrates energy efficiency of the energy detector (ED) and the reliability of the preamble detector (PD). The probability of detection/false alarm and power consumption of cascaded-CCA in the CCA modules of IEEE 802.11b are analyzed and compared with ED and PD as an example. The performance of cascaded-CCA is explored via MATLAB simulations that implement the CCA modules and medium access control (MAC) protocol for IEEE 802.11 and IEEE 802.15.4. Simulation results showed that cascaded-CCA improves the energy efficiency significantly compared to ED-only or PD-only CCA. In addition, ED, PD, and cascaded CCA are applied to a cognitive network scenario to validate the effectiveness of the proposed cascaded-CCA.

The Development of 12.1' SVGA Reflective Color Thin Film Transistor Liquid Crystal Display with The New Structured Reflector and Optimized Optical Films

  • Shin, Jong-Eup;Joo, Young-Kuil;Jang, Yong-Kyu;Kang, Myeon-Koo;Souk, Jun-Hyung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.19-20
    • /
    • 2000
  • We have developed the 12.1" SVGA reflective type color TFT-LCD(Thin Film Transistor - Liquid Crystal Display) with the high aperture ratio and well designed reflector for the applications such as mini note PC, Note PC and electronic book. The panel shows the high reflectance(30%) and contrast ratio(20:1) resulted from optimizing the optical films and designing the embossing shaped reflector. By improving the chromacity, the color reproducibility was increased up to 20%. As removing the backlight unit, we reduced the power consumption, thickness and weight of the panel to 0.8W, 2.2mm, and 250gram, respectively. According to the above performances, we have obtained fabrication process for mass production, and furthermore, could have access to fast market launching.

  • PDF