• Title/Summary/Keyword: Electronic Circuit

Search Result 3,012, Processing Time 0.029 seconds

Wideband 6-port Phase Correlator Using Caxial Cable Impedance Transformer and Wireline Coupler (동축선 임피던스 변환기와 Wireline Coupler를 이용한 광대역 6-단자 위상 상관기)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.8
    • /
    • pp.1188-1195
    • /
    • 2022
  • The 6-port phase correlator consists of one in-phase power divider and three 3-dB 90-degree phase difference power dividers, and is mainly used in a demodulation circuit that determines the phase of an input signal. This paper proposes the wideband 6-port phase correlator that consists of an in-phase power divider using a wideband 2:1 impedance transformer with three 37.5-Ω coaxial cables, and a 3-dB 90-degree phase difference power divide using Wireline. The proposed wideband phase correlator fabricated at a center frequency of 1000MHz has the value of the input reflection coefficient(S11 and S22) -14dB or less in the frequency range of 640~1270MHz. Also, the signal transmission characteristic(Si1), from the in-phase power divider input port to four output ports, has the amplitude of -6.5±0.6dB and the phase error of within ±3.4°, and the signal transmission characteristic(Si2), from the 90 degree phase difference power divider input port to four output ports, has the amplitude of -6.1±0.6dB and the phase error of within ±6.2°.

A Study on the Effects of Ambient Light on the Reflective PPG Measurement Device using Infrared (적외선을 사용한 반사형 PPG 측정 장치에서의 주변광의 영향에 대한 연구)

  • Namsub Kim
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.406-412
    • /
    • 2023
  • In this paper, we studied the effect of noise caused by ambient light on a reflective PPG measurement device using infrared light. Noise caused by ambient light was examined by dividing it into general situations and special situations. In the general situation, noise due to changes in time and ambient light sources was randomly observed, and in the special situation, a halogen lamp was used to observe the effect of noise variations. In the experiment, PPG signals were measured and data acquired in real-time depending on each situation, and the measured data was analyzed in the time domain and frequency domain. First, through a general situation experiments, it was visually observed that noise increases with the brightness of ambient light, and through frequency analysis, it was observed that the noise sources were white noise, power line noise, and internal noise of the circuit. Futhermore, using a halogen lamp, we experimented with the change in noise depending on the change in distance from the ambient light and calculated the SNR. As a result of the experiment, an SNR of 3.2 dB was shown at a distance of 50 cm with an irradiance of 278.3 W/m2. It was observed that normal measurement was difficult at SNRs below that, and an irradiance of 27.7 W/m2 was obtained. It showed a value of 18.2 dB at a distance of 2 m, and it was observed that normal PPG measurement was possible through a filter at values above that.

Implant Isolation Characteristics for 1.25 Gbps Monolithic Integrated Bi-Directional Optoelectronic SoC (1.25 Gbps 단일집적 양방향 광전 SoC를 위한 임플란트 절연 특성 분석)

  • Kim, Sung-Il;Kang, Kwang-Yong;Lee, Hai-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.52-59
    • /
    • 2007
  • In this paper, we analyzed and measured implant isolation characteristics for a 1.25 Gbps monolithic integrated hi-directional (M-BiDi) optoelectronic system-on-a-chip, which is a key component to constitute gigabit passive optical networks (PONs) for a fiber-to-the-home (FTTH). Also, we derived an equivalent circuit of the implant structure under various DC bias conditions. The 1.25 Gbps M-BiDi transmit-receive SoC consists of a laser diode with a monitor photodiode as a transmitter and a digital photodiode as a digital data receiver on the same InP wafer According to IEEE 802.3ah and ITU-T G.983.3 standards, a receiver sensitivity of the digital receiver has to satisfy under -24 dBm @ BER=10-12. Therefore, the electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysed and measured results of the implant structure, the M-BiDi SoC with the implant area of 20 mm width and more than 200 mm distance between the laser diode and monitor photodiode, and between the monitor photodiode and digital photodiode, satisfies the electrical crosstalk level. These implant characteristics can be used for the design and fabrication of an optoelectronic SoC design, and expended to a mixed-mode SoC field.

A Study on Development of Alternative Non-aqueous Cleaning Agents to Ozone Depletion Substances and its Field Application (오존파괴물질 대체 비수계세정제 개발 및 현장 적용 연구)

  • Park, Yong-Bae;Bae, Jae-Heum;Lee, Min-Jae;Lee, Jong-Gi;Lee, Ho-Yeoul;Bae, Soo-Jung;Lee, Dong-Kee
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.306-313
    • /
    • 2011
  • Flux or solder is used in soldering process for manufacturing electronic parts such as printed circuit boards (PCB). After soldering process, residual flux and solder paste on the parts should be removed since their residuals could cause performance degradation or failure of parts due to their corrosion and electric leakage. Ozone depletion substances such as 1,1,1- trichloroethane (TCE) and HCFC-141b have widely been using for removal of residual flux and solder paste after soldering process In manufacturing of electronic parts until now. In this study, non-aqueous cleaning agents without flash point were developed and applied to industrial field for replacement of cleaning agents with ozone depletion. In order to develop non-aqueous cleaning agents without ethers, esters, fluoride- type solvents. And their physical properties and cleaning abilities were evaluated, and they were applied to industrial fields for cleaning of flux and solder on the PCB. And vacuum distillation apparatus were operated to determine their operating conditions and recycling yields for recycling of used cleaning agents formulated in this study. As a result of physical properties measurement of our formulated cleaning agents, they were expected to have good wetting and penetrating power since their surface tensions were relatively low as 18.0~20.4 dyne/$cm^2$ and their wetting indices are relatively large. And some cleaning agents holding fluoride-type solvents as their components did not have any flash point and they seemed to be safe in their handling and storage. The cleaning experimental results showed that some cleaning agents were better in their cleaning of flux and solder paste than 1,1,1-TCE and HCFC-141b. And industrial application results of the formulated cleaning agents for cleaning PCB indicated that they can be applicable to industry due to their good cleaning capability in comparison with HCFC-141b. The recycling experiments of the used formulated cleaning agents through a vacuum distillation apparatus also showed that their 91.9~97.5% could be recycled with its proper operating conditions.

Impact Resistance Reliability of Sn-1.2Ag-0.5Cu-0.4In Solder Joints (Sn-1.2Ag-0.5Cu-0.4In 조성 솔더 접합부의 내 충격 신뢰성 평가)

  • Yu, A-Mi;Lee, Chang-Woo;Kim, Jeong-Han;Kim, Mok-Soon;Lee, Jong-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.226-226
    • /
    • 2008
  • 지난 10여년 동안 Sn-3.0Ag-0.5(wt%)Cu 합금은 대표 무연솔더 조성으로 다양한 전자제품의 실장 및 접합에 적용되어 왔으며, 그 신뢰성 역시 충분히 검증된 바 있다. 그러나 최근 Ag 가격의 급격한 상승과 솔더 접합부의 내 충격 신뢰성을 보다 향상시키고자 하는 업계의 동향은 Ag의 함량이 낮은 무연솔더 조성의 적용 확대를 유도하고 있다. 이에 따라 본 연구자들은 저 Ag 함유 무연슬더로 Sn-1.2Ag-0.5Cu-0.4In 조성을 제안한 바 있는데, 이는 Sn-3.0Ag-0.5Cu 조성 이상의 solderability를 가지면서도 그 금속원료 가격이 약 20% 가량 저렴한 특징을 가진다. 또한 열 싸이클링 (cycling) 테스트를 통한 슬더 조인트의 신뢰성을 평가한 결과, Sn-3.0Ag-0.5Cu에 크게 뒤떨어지지 않는 양호한 특성이 관찰되었다. 따라서 본 연구에서는 열 싸이클링 테스트와 더불어 최근 그 중요성이 지속적으로 커지고 있는 내 충격 신뢰성 평가 시험을 실시하여 개발된 4원계 무연솔더 조성의 기계적 특성을 기존 무연솔더 조성과 비교, 분석해 보았다. 각 솔더 조성은 솔더 볼 형태로 제조되어 CSP(Chip Scale Package) 상에 범핑 (bumping)되었으며, CSP를 PCB(Printed Circuit Board) 상에 실장하는 공정에서도 Sn-3.0Ag-0.5Cu 및 Sn-1.2Ag-0.5Cu-0.4In의 두 종류의 솔더 페이스트가 사용되었다. 본 연구에서의 내 충격 신뢰성 시험에는 자체 제작한 rod drop 시험기를 사용하였는데, 고정된 CSP 실장 board의 후면 부위를 일정한 높이에서 추를 반복적으로 자유 낙하시켜 급격한 충격을 주는 방식으로 실험을 실시하였다. 이 때 추의 무게는 30g, 낙하 높이는 10cm 였으며, 추의 낙하 시 측정된 board 의 휨 변위량은 약 0.7mm로 측정되었다. 사용된 CSP와 PCB 는 모두 daisy chain 방식으로 연결되어 있기 때문에 저항측정기를 사용한 간단한 실시간 저항 측정 방법으로 시험 이력에 따른 파단부의 발생 시점과 대략의 위치를 손쉽게 확인할 수 있었다. 솔더 조인트의 파단 기준 저항값으로 $1000\Omega$을 설정하였으며. 각 조건 당 5 개 이상의 샘플에 대해 평가를 실시한 후 그 평균값을 조사하였다. 시험 결과 제안된 Sn-1.2Ag-0.5Cu-0.4In 조성은 대표적인 저 Ag 함유 조성인 Sn-1.0Ag-0.5Cu에 비해서는 떨어지는 내 충격 신뢰성을 나타내었지만, 우수한 연성에 기인하여 Sn-3.0Ag-0.5Cu 조성에 비해서는 약 2 배 이상 우수한 신뢰성이 관찰되었다. 또한 CSP의 실장 시 Sn-3.0Ag-0.5Cu보다 Sn-1.2Ag-0.5Cu-0.4In 조성 솔더 페이스트를 적용한 경우에서 보다 우수한 내 충격 신뢰성을 나타내어 기본적으로 개발된 Sn-1.2Ag-0.5Cu-0.4In 솔더 페이스트가 Sn-3.0Ag-0.5Cu 조성의 기존 솔더 페이스트 보다 내 충격 신뢰성이 우수함을 검증할 수 있었다. 각 조성의 솔더 조인트를 $150^{\circ}C$ 에서 500시간 aging한 후 실시한 내 충격 신뢰성 평가에서는 모든 조성에서 그 신뢰성이 급감하는 경항을 나타내었으나, Sn-1.2Ag-0.5Cu-0.4In가 Sn-l.0Ag-0.5Cu보다도 그 상대적인 신뢰성이 우수한 것으로 관찰되었다. 이와 같이 aging 후 실시하는 충격시험은 가장 실제적인 상황과 유사한 조건이므로 상기의 실험 결과는 매우 고무적이었으며, 이에 대한 보다 면밀한 분석이 요청되었다. 마지막으로 파면 및 미세조직 관찰을 통하여 각 조성에서의 충격 파단 특성을 비교, 분석해 보았다.

  • PDF

Development and Complementation of Evaluation Area and Content Elements in Electrical, Electronics and Communications Subject (중등교사 임용후보자선정경쟁시험 표시과목인 전기·전자·통신의 평가영역 및 내용요소 개발·보완 연구)

  • Song, Youngjik;Kang, Yoonkook;Cho, Hanwook;Gim, Seongdeuk;Lim, Seunggak;Lee, Hyuksoo
    • 대한공업교육학회지
    • /
    • v.44 no.1
    • /
    • pp.52-71
    • /
    • 2019
  • The quality of school education is a key element for national education development. An important factor that determines the quality of school education is qualities of teachers who are in responsible for school education in the field. Therefore, it is necessary to hire competent teachers in the teacher appointment exam for the secondary school. This necessity is evident especially for vocational high schools and Meister high schools with the introduction of 2015-revised curriculum based on NCS that separates each three subjects, "Electrical, Electronics Communication" resulting in the change of question mechanism, which requires new designing of assessment and content area. So, this study analyzes curriculum in college of education for "Electrical", "Electronics", "Communication", 2015-revised curriculum based on NCS and the development of standards for teacher qualifications and assessment area and evaluation of teaching ability in the subjects of the teacher appointment exam, "Electrical, Electronics Communication" Engineering" in 2009. The assessment area and content elements of "Electrical", "Electronics", "Communication are extracted from the analyzed results and they are verified by experts' consultation and presented as follows; First, the assessment area and content elements of the "Electrical" subject were designed to evaluate the NCS - based 2015 revised curriculum by presenting the NCS learning module to the evaluation area and content element in the basic subject "Electrical and Electronics Practice". Second, the section of "Electronics" presented the assessment area and content elements applying the Electronic Circuit, basic subject of the NCS and it also added "Electromagnetics", which is the basic part of Electronics in the Application of Electromagnetic waves that could be applied to the assessment. Third, the assessment area and content elements of "Communication" consist of the communication-related practice that is based on "Electrical" and "Electronic", considering the characteristics of "Communication Engineering". In particular, "Electrical and Electronics practice" which adds network construction practice and communication-related practice makes it to be able to evaluate the communication-related practical education.

Particle Size Analysis of Cadmium Aerosol for Cadmium Inhalation Toxicology Study (766ppm Cadmium Nebulizing Solution) (카드뮴의 흡입독성 연구를 위해 설계된 에어로졸 발생장치에서 발생된 카드뮴 에어로졸의 입경분석(766ppm 카드뮴 네뷸라이징 용액))

  • Jeung Jae Yeal;Milton Donald K.;Kim Tae Hyeung;Lee Jong Young;Jahng Doo Sub;Kang Sung He;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.5
    • /
    • pp.1035-1041
    • /
    • 2002
  • Ultrasonic nebulizer with the application of new engineering methodology and the design of electronic circuit and 766ppm Cd nebulizing solution were used to generate cadmium aerosol for inhalation toxicology study. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 43.449 x 10³ in inlet temperature 250℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 43.211 x 10³ in inlet temperature 100 ℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 41.917x10³ in inlet temperature 250℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter(GMD) were 0.677-1.009㎛ in source temperature 20℃, 0.716-0.963㎛ in source temperature 50℃, and 0.724-0.957㎛ in source temperature 70℃. The smallest GMD was 0.677㎛ in source temperature 20℃ and inlet temperature 20℃. and the largest GMD was 1.009㎛ in source temperature 20℃ and inlet temperature 20℃. The ranges of geometric standard deviation(GSD) were 1.635-2.101 in source temperature 20℃. 1.676-2.073 in source temperature 50℃, and 1.687-2.051 in source temperature 70℃. The lowest GSD was 1.635 in source temperature 20℃ and inlet temperature 20℃, and the highest GSD was 2.101 in source temperature 20℃ and inlet temperature 200℃. Aerosol generated for cadmium inhalation toxicology study was polydisperse aerosol. The ranges of mass median diameter(MMD) were 1.399-5.270㎛ in source temperature 20℃. 1.593-4.742㎛ in source temperature 50℃, and 1.644-4.504㎛ in source temperature 70℃. The smallest MMD was 1.399㎛ in source temperature 20℃ and inlet temperature 20℃, and the largest MMD was 5.270㎛ in source temperature 20℃ and inlet temperature 200℃. Increasing trends for GMD, GSD, and MMD were observed with same source temperature and increase of inlet temperature. MMD for inhalation toxicology testing in EPA guidance is less than 4㎛. In our results. inlet temperature 20 and 50℃ in source temperature 20℃, and inlet temperature 20 to 150℃ in source temperature 50 and 70℃ were conformed to the EPA guidance. MMD for inhalation toxicology testing in OECD and EU is less than 3㎛. In our results, inlet temperature 20 and 50℃ in source temperature 20, 50, and 70℃ were conformed to the OECD and EU guidance.

A Study on Formulation of Surfactant-free Aqueous Cleaning agents and Evaluation of Their Physical Properties and Cleaning Ability (계면활성제 무첨가 세정제의 배합 및 물성/세정성 평가 연구)

  • Lee, Jae Ryoung;Yoon, Hee Keun;Lee, Min Jae;Bae, Jae Heum;Bae, Soo Jeong;Lee, Ho Yeoul;Kim, Jong Hee
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.219-225
    • /
    • 2013
  • Environment-friendly and surfactant-free aqueous cleaning agents have been developed in order to solve various problems generated by surfactants in the aqueous cleaning agents. Aqueous surfactant-free cleaning agents, S-1 and S-2 have been formulated with water-soluble solvents such as propylene glycol and propylene glycol ether on their main components and with some additives. These solvents were chosen because of their good solubility in water and excellent solubility of fluxes which are major contaminants of printed circuit board in the electronic industry. Physical properties of the formulated and the imported cleaning agents were measured to predict their cleaning performance, and their cleaning abilities of flux and solder contaminants were evaluated under the various ultrasonic frequencies by a gravimetric method. The measurement results show that the physical properties of cleaning agent V are generally similar with those of formulated cleaning agents S-1 and S-2. Both the cleaning agent V and the formulated cleaning agents S-1 and S-2 showed similar trends that their pH decrease in the beginning and then increases later on with the increase of their dilution in water. It is considered that the wetting indices of the cleaning agents calculated with experimental values do not not have any influence on their cleaning ability. In ultrasonic cleaning tests under three ultrasonic frequencies of 28, 45, and 100 kHz, their best performances of cleaning solder and flux were obtained at 45 kHz and 28 kHz, respectively, and the cleaning performance of the formulated cleaning agents S-1 and S-2 was better than that of the cleaning agent V. However, in the case of the recommended diluted concentration of 25 wt% cleaning solution, the cleaning performance of the cleaner V for solder and flux was better in the initial stage of cleaning compared to the formulated cleaners. And it may be concluded that the formulated cleaning agents S-1 and S-2 can be applied to cleaning of solder and flux in the industry, based on the experimental results in this study.

Particle Size Analysis of Lead Aerosol with the use of 2730ppm Lead Nebulizing Solution for Inhalation Toxicology Study (흡입독성 연구를 위한 2730ppm 납 네뷸라이징 용액에서 발생된 에어로졸의 입경분석)

  • Jeung Jae Yeal;Kang Sung Ho;Kim Sam Tae;Lee Eun Kyoung;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.2
    • /
    • pp.518-524
    • /
    • 2003
  • Ultrasonic nebulizer with the application of new engineering methodology and the design of electronic circuit was made for lead inhalation toxicology study and 2730ppm lead nebulizing solution was used to generate lead aerosol. After modification of source and inlet temperatures, the results of particle size analysis for lead aerosol were as following. The highest particle counting for source temperature 20℃ was 39933.66 in inlet temperature 100℃ and particle diameter 0.75tLm. The highest particle counting for source temperature 50℃ was 39992.71 in inlet temperature 250℃ and particle diameter 0.75μm. The highest particle counting for source temperature 70℃ was 37569.55 in inlet temperature 50℃ and particle diameter 0.75μm. The ranges of geometric mean diameter(GMD) were 0.754-0.784μm for source temperature 2℃, 0.758-0.852μm for source temperature 50℃, and 0.869-1.060μm for source temperature 70℃. The smallest GMD was 0.754μm in source temperature 20℃ and inlet temperature 20℃, and the largest GMD was 1.060μm in source temperature 70℃ and inlet temperature 250℃. The ranges of geometric standard deviation(GSD) were 1.730-1.782 for source temperature 20℃, 1.734-1.894 for source temperature 50℃, and 1.921-2.148 for source temperature 70℃. The lowest GSD was 1.730 in source temperature 20℃ and inlet temperature 20℃, and the highest GSD was 2.148 in source temperature 70℃ and inlet temperature 250℃. Lead aerosol generated in this study was polydisperse. The ranges of mass median diameter(MMD) were 1.856-2.133μm for source temperature 20℃, 1.877-2.894μm for source temperature 50℃, and 3.120-6.109μm for source temperature 70℃. The smallest MMD was 1.856μm in source temperature 20℃ and inlet temperature 20℃, and the largest MMD was 6.109μm in source temperature 70℃ and inlet temperature 250℃. Slight increases for GMD, GSD, and MMD values were observed with same source temperature and increase of inlet temperature. MMD for inhalation toxicology testing in EPA guidance is less than 4μm. In this study, source temperature 20℃ and 50℃ with inlet temperature from 20℃ to 250℃ were conformed to the EPA guidance, but inlet temperature 20℃ and 50℃ for source temperature 70℃ were conformed EPA guidance. MMD for inhalation toxicology testing in OECD and EU is less than 3μm. In this study, source temperature 20℃ and 50℃ with inlet temperature from 20℃ to 250℃ were conformed to the EPA guidance, but none for source temperature 70℃.

Recent study of Acupuncture in Treatment of Urianry Disturbance (배뇨장애(排尿障碍)에 대한 침구치료(鍼灸治療)의 연구동향(硏究動向))

  • Kim, Kyung-tai;Ko, Young-jin;Kim, Yong-suk;Kim, Chang-hwan
    • Journal of Acupuncture Research
    • /
    • v.22 no.3
    • /
    • pp.123-135
    • /
    • 2005
  • Objective : The aim of this study was to rivew systemically literature and clinical trials in the treatment of urinary incontinence or lower urinary tract syndrome(LUTS). Methods : Computerized literature searches were carried out on two electronic database, and computerized searching on some korea oriental medicine journals in library of Kyung-Hee Medical center. Results : 1. Three reports of review study, six reports of experimental study and fourteen reports of clinical trials were collected and reviewed. Three reports of review study were all printed in the korea oriental medicine journal. From 2000, researches and studies have been increased in quantity and improved in quality. 2. Urinary disturbance include variable symptoms of lower urinary tract symptoms, urinary incontinence, in theaspect of Oriental medicine these symptoms are anurin, dysuria, urinary incontinence, nochumal enuresis, uracratia and so on. 3. Roughly physiological procedure of Acupuncture in Treatment of Urianry Disturbance may be that effect of acupuncture stimulation for parasympathetic nerve, sleep-arousal system in cerebrum, pontine/spinal urination center and pudendal/pelvic nerve affect bladder in expansion of bladder capacity, inhibition of urinary contraction and affection in periurethral muscle by continuous excitement of spinal annular circuit and synapse of neuron. 4. Clinical result for acupuncture treatment in urinary disturbance is summarized that acupuncture treatment in urianation disturbance of Neurogenic Bladder, Incontinence, Cycitis, Nocturnal Enuresis, Prostatitis/Pelvic Pain Syndrom and so on is significant clinical trials and technique. Conclusion : Hereafter, in the old age society these variable urinary disturbance patients are increased and desire of treatment may be also increased. So study of various and formal treatment and tecnnique is needed.

  • PDF