• 제목/요약/키워드: Electron detector

검색결과 264건 처리시간 0.03초

QCM을 이용한 자기조립화된 Viologen 단분자막의 전기화학적 특성 연구 (Electrochemical Properties of Self-Assembled Viologen Monolayer Using QCM)

  • 옥진영;박상현;김병상;신훈규;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1520-1522
    • /
    • 2003
  • Molecular self-assembled of surfactant viologen are of recent interest because they can from functional electrodes as well as micellar assemblies, which can be Profitably utilized for display devices, photoelectrochemical studies and electrocatalysis as electron acceptor or electron mediator. Fromherz et al studied the self-assembly of thiol and disulfide derivatives of viologens bearing long n-alkyl chains on Au electrode surface. The electrochemical behavior of self-assembled viologen monolayer has been investigated with QCM, which has been known as nano-gram order mass detector. The self-assembly process of viologen was monitored using resonant frequency (${\Delta}$F) and resonant resistance (R). The redox process of viologen was observed with resonant frequency (${\Delta}$F).

  • PDF

2-클로로벤질 알코올 및 2,4-디클로로벤질 알코올 유도체를 이용한 TDI, MDI 및 HDI의 가스크로마토그래피 분석 (Gas Chromatographic Analysis of TDI, MDI and HDI Using 2-Chlorobenzyl Alcohol and 2,4-Dichlorobenzyl Alcohol Derivatives)

  • 윤주송;박준호;이강명;최홍순;조영봉;고상백;차봉석
    • 한국산업보건학회지
    • /
    • 제16권3호
    • /
    • pp.222-232
    • /
    • 2006
  • Objectives: The objective of this study was to propose the total isocyanate analytical method which involves derivation of 2,4-toluene diisocyanate(2,4-TDI), 2,6-toluene diisocyanate(2,6-TDI), 4,4'-methylenediphenyl diisocyanate(4,4'-MDI) and 1,6-hexamethylene diisocyanate(1,6-HDI) using 2-chlorobenzyl alcohol(2-CBA) or 2,4-dichlorobenzyl alcohol(2,4-DCBA), and analyzing of hydrolysate of the synthesized urethane with the gas chromatography(GC)/flame ionization detector(FID), GC/pulsed discharge ionization detector-electron capture detector(PD-ECD) and GC/mass selective detector(MSD). Methods: Urethanes were synthesized by reacting 2,4-TDI, 2,6-TDI, 4,4'-MDI and 1,6-HDI to 2-CBA or 2,4-DCBA. Urethanes was verified by TLC, HPLC/UVD and GC/MSD. For field application, the most suitable condition that 2-CBA coated in glass fiber filter removed completely and urethanes were not removed was searched. 2-CBA generated from hydrolysis of urethanes according to hydrolysis conditions. Diisocyanates were collected on field air and analyzed. Results: Urethanes which were white and solid phase synthesized by reacting 2,4-TDI, 2,6-TDI, 4,4'-MDI, 1,6-HDI and 2-CBA or 2,4-DCBA. And urethanes were verified by TLC, HPLC/UVD and GC/MSD. The most suitable conditions to remove 2-CBA coated in glass fiber filter were $87^{\circ}C$ and 20 mmHg and urethanes were not removed under same condition. Hydrolysis yields of urethanes were 99 % to 111 %. 2-CBA, the hydrolysate of urethanes was analyzed by GC/FID, GC/PD-ECD and GC/MSD. Conclusions: Simultaneous analysis of 2,4-TDI, 2,6-TDI, 4,4'-MDI and 1,6-HDI deriving with 2-CBA and 2,4-DCBA, along with a total isocyanate analysis, was feasible with GC/FID, GC/PD-ECD and GC/MSD. This result will be a guide of further study on total isocyanate analysis.

선량보강(Build-up) 영역에서의 광자선 깊이선량률 측정을 위한 검출기의 특성 비교 (Characteristics of Detectors for Measurements of Photon Depth Doses in Build-Up Region)

  • 강세권;박석원;오도훈;박희철;김수산;배훈식;조병철
    • 한국의학물리학회지:의학물리
    • /
    • 제16권2호
    • /
    • pp.77-81
    • /
    • 2005
  • 표면 선량을 포함한 선량보강(build-up) 영역에 대한 깊이선량률(percentage depth dose)을 측정하는 데 있어서 적절한 측정방법을 결정하기 위해 6 MV 광자선에 대해 Atiix와 Markus 평행평판형 이온함, 원통형이온함, 그리고 다이오드 검출기를 사용하여 측정, 비교하었다. Attix 이온함에 의한 측정을 기준으로 할 때, Markus 이온함의 측정은 민조사면(open field)에서 $2\%$ 내로 일치하였으나, 오염전자가 포함된 광자선의 경우에는 최대 $3.9\%$의 차이를 보였다. 원통형 이온함과 다이오드 선량계의 경우에는 이들 검출기가 물 팬텀에 완전히 잠긴 이후부터는 오염전자가 포함된 광자선에 대해서도 각각 $1.5\%$ 혹은 $1.0\%$ 내의 정확도를 보였다. 따라서 민조사면에서 표면선량을 포함한 깊이선량률을 정확히 측정하기 위해서는 평행평판형 이온함이 추천되나, 표면에서의 정확한 선량에 특별한 관심을 두는 경우가 아니면, 원통형 이온함이나 다이오드 선량계를 이용하여 선량보강영역의 깊이선량률을 측정하는 것은 양호한 결과를 준다고 할 수 있다.

  • PDF

서울지역 학교급식 식재료의 잔류농약 위해성 평가 (Monitoring and risk assessment of pesticide in school foodservice products in seoul, Korea)

  • 서영호;문광덕
    • 한국식품저장유통학회지
    • /
    • 제21권1호
    • /
    • pp.69-74
    • /
    • 2014
  • 학교 급식 식재료로 사용되는 농산물 중 잔류농약의 안전성을 평가하고자 서울시내 초, 중, 고등학교 110곳에서 316건의 시료를 수거하여 잔류농약을 분석하였다. 185종의 농약에 대해 GC-ECD, GC-NPD, GC-MSD 및 HPLC-UVD를 이용한 다종농약 다성분 분석법으로 잔류농약을 분석하였고, 분석결과 26건의 시료에서 농약이 검출되었고, 취나물과 들깻잎에서 각각 57.1, 55.6%의 높은 검출율을 나타내었다. 농약 성분별 검출빈도는 프로시미돈, 엔도설판, 아족시스트로빈의 순으로 높게 나타났으며, 2종 이상의 농약이 동시에 검출된 것은 3건이었다. 그리고 검출된 시료 중 잔류허용기준을 초과한 시료는 6건이었으며 시금치, 취나물, 양배추에서 엔도설판, 깻잎에서는 디니코나졸과 카보후란, 고추에서는 에토프로포스가 잔류허용기준치를 초과하여 검출되었다. 위해성 평가결과 들깻잎에서 검출된 카보후란의 hazard index가 3.8%로 가장 높았으며, 다른 농산물들은 모두 2% 미만을 나타내어 위해도가 매우 낮은 것으로 조사되었다. 따라서 서울지역 학교급식 식재료로 사용되는 농산물은 비교적 안전한 수준으로 농약관리가 이루어지는 것으로 판단되며, 지속적으로 농약의 안전한 사용을 위한 홍보와 교육이 이루어져야 할 것으로 여겨진다.

Evaluation of Residual Pesticides in Fresh Ginseng Collected in Seoul

  • Kim, Tae-Rang;Park, Ki-Hwan;Jang, Mi-Ra;Choi, Young-Hee;Kim, Eun-Hee;Choi, Chae-Man;Park, Sung-Kyu;Yu, In-Sil;Hwang, In-Sook;Han, Ki-Young;Kim, Moo-Sang;Kim, Jung-Hun;Chae, Young-Zoo
    • Journal of Applied Biological Chemistry
    • /
    • 제56권1호
    • /
    • pp.29-35
    • /
    • 2013
  • This study was performed to analyze 48 kinds of pesticide residues using gas chromatography (GC)/nitrogen phosphorous detector, GC/micro electron capture detector, GC/mass selective detector, and high performance liquid chromatograph/diode array detector in 186 fresh ginseng samples collected in the Seoul area from 2010 to 2011. Fresh ginseng dietary intakes were estimated using the data from the 2009 Korea National Health and Nutrition examination survey. Residual pesticides were detected in 79 samples (42.5%) with eight different fungicides. Only 20 samples (10.8%) exceeded the maximum residue limits (MRLs) for pesticides registered by the Korea Food & Drug Administration. Among them, tolclofos-methyl residues (10.2%) exceeded the MRL for fresh ginseng in 18 ginseng seedlings and one of the two-year old fresh ginseng plants, and the residual level in just one ginseng seedling violated the MRL for pyrimethanil. The results showed that residual pesticides levels in marketable fresh ginseng around Seoul were relatively safe. The percent acceptable daily intake (%ADI) was calculated using pesticide residues in fresh ginseng and dietary intakes of fresh ginseng. The risk caused by pesticide residues in fresh ginseng was very low.

원자간인력현미경을 이용한 분자수준의 중금속 이온 검출 (Molecular Level Detection of Heavy Metal Ions Using Atomic Force Microscope)

  • 김영훈;강성구;최인희;이정진;이종협
    • 청정기술
    • /
    • 제11권2호
    • /
    • pp.69-74
    • /
    • 2005
  • 본 연구에서는 AFM 양극산화법을 이용하여 서브마이크로 수준의 패턴을 구성하였다. 자기조립법으로 제조한 MPTMS/Si(100) 기질 위에 AFM 양극산화법으로 패턴을 형성하였고, 비에칭법을 이용하여 아민그룹을 지닌 기능기를 고정시켰다. 금속전극으로는 Frens 방법으로 제조한 금나노입자를 이용하였다. 금속이온의 흡착에 따른 전도도는 근거리의 경우 coherent tunneling에 의존하지만, 원거리 전극에서는 incoherent tunneling에 의존한다. 전극의 간격이 가까울수록 저항이 감소하여 센서의 감도와 최소검출능을 개선할 수 있었다. 또한 다중기능성을 부여하여 센서의 선택도를 부여하였으며, 패턴의 크기에 따른 최소검출농도를 낮출 수 있음을 확인하였다.

  • PDF

Influence of Ne-Xe Gas Mixture Ratio on the Extreme Ultraviolet (EUV) Emission Measurement from the Coaxially Focused Plasma

  • Lee, Sung-Hee;Hong, Young-June;Choi, Duk-In;Uhm, Han-Sup;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.220-220
    • /
    • 2011
  • The Ne-Xe plasmas in dense plasma-focus device with coaxial electrodes were generated for extreme ultraviolet (EUV) lithography. The influence of gas mixture ratio, Ne-Xe (1, 10, 15, 20, 25, 30, 50%) mixture gas, on EUV emission measurement, EUV intensity and electron temperature in the coaxially focused plasma were investigated. An input voltage of 4.5 kV was applied to the capacitor bank of 1.53mF and the diode chamber was filled with Ne-Xe mixture gas at a prescribed pressure. The inner surface of the cylindrical cathode was lined by an acetal insulator. The anode was made of tin metal. The EUV emission signal of the wavelength in the range of 6~16 nm has been detected by a photo-detector (AXUV-100 Zr/C, IRD). The visible emission line was also detected by the composite-grating spectrometer of the working wavelength range of 200~1100 nm (HR 4000CG). The electron temperature is obtained by the optical emission spectroscopy (OES) and measured by the Boltzmann plot with the assumption of local thermodynamic equilibrium (LTE).

  • PDF

Measurement of EUV Emission and its Plasma Parameters Generated from the Coaxial Plasma Focus of Mather and Hypocycloidal Pinched Electrodes

  • Lee, Sung-Hee;Lee, Kyung-Ae;Hong, Young-June;Uhm, Han-Sup;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.332-332
    • /
    • 2011
  • The extreme ultraviolet (EUV) radiation, whose wavelength is from 120 nm down to 10 nm, and the energy from 10 eV up to 124 eV, is widely utilized such as in photoelectron spectroscopy, solar imaging, especially in lithography and soft x-ray microscopy. In this study, we have investigated the plasma diagnostics as well as the debris characteristics between the two types of dense plasma focusing devices with coaxial electrodes of Mather and hypocycloidal pinch (HCP), respectively. The EUV emission intensity, electron temperature and plasma density have been investigated in these cylindrical focused plasma along with the debris characteristics. An input voltage of 5 kV has been applied to the capacitor bank of 1.53 uF and the diode chamber has been filled with Ar gas at pressure ranged from 1 mTorr and 180 mTorr. The inner surface of the cathode was covered by polyacetal insulator. The central anode electrode has been made of tin. The wavelength of the EUV emission has been measured to be in the range of 6~16 nm by a photo-detector (AXUV-100 Zr/C, IRD). The visible emission has also been measured by the spectrometer with the wavelength range of 200~1,100 nm. The electron temperature and plasma density have been measured by the Boltzmann plot and Stark broadening methods, respectively, under the assumption of local thermodynamic equilibrium (LTE).

  • PDF

6 MV 광자선과 6 MeV 전자선 하에서 TLD 기판 위에 얹힌 금속 박막의 효과 (The Effects of Metal Plate loaded on TLD chip in 6 MV Photon and 6 MeV Electron Beams)

  • Kim, Sookil;Byungnim Min
    • 한국의학물리학회지:의학물리
    • /
    • 제10권1호
    • /
    • pp.41-46
    • /
    • 1999
  • 본 실험은 의료용 가속기로부터 나오는 6MV 광자선과 6 MeV 전자선을 고체 팬텀위의 LiF 열형광 선량계 (TLD-l00)에 쪼여서 수행하였다. TLD-l00의 방사선 반응감도를 증가시키기 위해 TLD-l00 기판 (표면적 3.2 $\times$ 3.2 $\textrm{mm}^2$) 위에 같은 면적의 금속박막 (주석 혹은 금)을 얹어서 실험하였다. SSD l00cm, 방사선장의 크기 10$\times$10 $\textrm{cm}^2$의 조건 하에서 표면 흡수선량을 측정하였다. 측정결과 각 금속들로 인하여 TLD-l00 의 신호강도가 증강된 것이 관측되었다. 그리고 표면 흡수선량이 방사선량에 따라서 매우 선형적인 값을 가지는 것으로 나타났다 .6 MV 광자선의 경우 1 mm 의 금속박막을 TLD-l00 에 얹은 결과 표면 흡수선량이 각 각 14%, 56% 증가되었다 .6MeV의 전자선의 경우에는 금박막은 TL 반응감도가 13% 증가되었으나 주석의 경우에는 전혀 변화가 없었다. 금속박막을 얹은 TLD-l00의 방사선량 반응감도는 금속박막의 전자 입자밀도에 따라 증가하는 것으로 관측되었다. 이것은 TLD-l00보다 큰 전자밀도를 가진 부가물질(금속박막 )로부터 TLD-l00으로 산란전자가 유입되는 데 기인하는 것으로 보인다. 이 결과로부터 금속박막을 얹은 TL 선량계가 치료광자선용 증폭 선량계로서의 역할을 할 수 있을 것임을 시사한다. 즉 금속박막으로 인해서 TLD-l00 의 방사선 량 반응감도가 증가되었으므로 높은 감도의 보다 작은 TL 선량계의 개발이 가능하게 되었다.

  • PDF

고해상도 지구관측위성 카메라의 복사신호량에 대한 통합적 모델링 (Integrated Radiometric Signal Modeling for High Resolution Earth Observation Satellite Camera)

  • 장홍술;정대준;육영춘;이승훈
    • 항공우주기술
    • /
    • 제7권2호
    • /
    • pp.82-87
    • /
    • 2008
  • 본 연구에서는 우주에서 가시광 영역으로 지구의 지표면을 고해상도로 촬영하는 위성탑재카메라를 위한 복사에너지 신호량을 모델링하였다. 복사에너지 모델링은 광원으로서의 태양과 지구대기 및 지표면 반사도, 카메라의 특성 등을 포함하며 최종 계산 결과는 광전자카메라의 광검지기에서 생성되는 전자의 수로 나타난다.

  • PDF