• Title/Summary/Keyword: Electron detector

Search Result 266, Processing Time 0.041 seconds

Calculation of Primary Electron Collection Efficiency in Gas Electron Multipliers Based on 3D Finite Element Analysis (3차원 유한요소해석을 이용한 기체전자증폭기의 1차 전자수집효율의 계산)

  • Kim, Ho-Kyung;Cho, Min-Kook;Cheong, Min-Ho;Shon, Cheol-Soon;Hwang, Sung-Jin;Ko, Jong-Soo;Cho, Hyo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • Gas avalanche microdetectors, such as micro-strip gas chamber (MSGC), micro-gap chamber (MGC), micro-dot chamber (MDOT), etc., are operated under high voltage to induce large electron avalanche signal around micro-size anodes. Therefore, the anodes are highly exposed to electrical damage, for example, sparking because of the interaction between high electric field strength and charge multiplication around the anodes. Gas electron multiplier (GEM) is a charge preamplifying device in which charge multiplication can be confined, so that it makes that the charge multiplication region can be separate from the readout micro-anodes in 9as avalanche microdetectors possible. Primary electron collection efficiency is an important measure for the GEM performance. We have defined that the primary electron collection efficiency is the fractional number of electron trajectories reaching to the collection plane from the drift plane through the GEM holes. The electron trajectories were estimated based on 3-dimensional (3D) finite element method (FEM). In this paper, we present the primary electron collection efficiency with respect to various GEM operation parameters. This simulation work will be very useful for the better design of the GEM.

Design of Thomson Scattering System Using VPH Grating for Plasma Processing

  • Joa, Sang-Beom;Ko, Min-Guk;Kang, In-Je;Yang, Jong-Keun;Yu, Yong-Hun;Lee, Heon-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.525-525
    • /
    • 2013
  • Low temperature plasma diagnosis is one of the big issues in laboratory scale or processing industry. One of the most powerful techniques of plasma diagnostics is the use of the scattering of electromagnetic radiation from the plasma. Electron temperature and density are important parameters for understanding the information of plasmas in the plasma processing industry. Laser scattering experiments on plasma can provide a substantial amount of information about plasma parameters such as the electron density ne, the electron temperature Te, and the neutral density nn and temperature Tn. Thomson scattering spectroscopy is used several method, in accordance with detector type. Commonly, Thomson scattering is used several notch filter to separate expanded wavelength. Since using a spectrometer with surface relief grating or notch filter, the system of the measurement will be complicated and bigger. In this study, using VPHG (Volume Phase Holographic Grating) in order to install the simple and cheap system. VPHG has the advantage of the system installation, because it can be Transmission Type. The diffraction efficiency and dispersion angle of VPHG is higher than the surface relief grating relatively. For a wavelength and bandwidth selection, Using a slit or mask to select a rejection wavelength instead of notch filter.

  • PDF

Modeling for UV Photo-detector with Pt/AIGaN Schottky diode (Pt/AIGaN 쇼트키 다이오드의 수광특성 모델링)

  • Kim Jong-Hwan;Lee Heon-Bok;Park Sung-Jong;Lee Jung-Hee;Hahm Sung-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.605-608
    • /
    • 2004
  • A $Pt/Al_xGa_{l-x}N$ Schottky type Ultra-violet photodetector was modeled and simulated using the commercial SILVACO software program. In the carrier transport, we applied field model and other analytic model to determine the electron saturation velocity and low field mobility for GaN and $Al_xGa_{l-x}N$. A C-Interpreter function was defined to described the mole-fraction for the ternary compound semiconductor such as $Al_xGa_{l-x}N$. As comparing the simulated and experimental results, we found that the simulated result for type-1 has $15.9 nA/cm^2$ of leakage current at 5V. We confirmed a good agreement of photo-current in the UV Photo-detector, while applying the absorption coefficient and reflective index of active $Al_xGa_{l-x}N$ and other layers. There had been an intensive search for the proper refractive indices of the layers.

  • PDF

A NUMERICAL METHOD TO ANALYZE GEOMETRIC FACTORS OF A SPACE PARTICLE DETECTOR RELATIVE TO OMNIDIRECTIONAL PROTON AND ELECTRON FLUXES

  • Pak, Sungmin;Shin, Yuchul;Woo, Ju;Seon, Jongho
    • Journal of The Korean Astronomical Society
    • /
    • v.51 no.4
    • /
    • pp.111-117
    • /
    • 2018
  • A numerical method is proposed to calculate the response of detectors measuring particle energies from incident isotropic fluxes of electrons and positive ions. The isotropic flux is generated by injecting particles moving radially inward on a hypothetical, spherical surface encompassing the detectors. A geometric projection of the field-of-view from the detectors onto the spherical surface allows for the identification of initial positions and momenta corresponding to the clear field-of-view of the detectors. The contamination of detector responses by particles penetrating through, or scattering off, the structure is also similarly identified by tracing the initial positions and momenta of the detected particles. The relative contribution from the contaminating particles is calculated using GEANT4 to obtain the geometric factor of the instrument as a function of the energy. This calculation clearly shows that the geometric factor is a strong function of incident particle energies. The current investigation provides a simple and decisive method to analyze the instrument geometric factor, which is a complicated function of contributions from the anticipated field-of-view particles, together with penetrating or scattered particles.

Digital X-ray Detector에 적용을 위한 Polycrystalline CdTe 구조에 따른 전기적 신호 연구

  • Kim, Jin-Seon;O, Gyeong-Min;Jo, Gyu-Seok;Song, Yong-Geun;Hong, Ju-Yeon;Heo, Seung-Uk;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.484-484
    • /
    • 2013
  • 기존 진단용 Digital X-ray Detector이 직접방식에서는 a-Se (Amorphous Selenium)이 대중화되었지만 고전압을 인가하여야한다는 점과 그로 인한 물질 자체의 Life time 감소 등 여러 단점들 때문에 기타 후보물질들로 HgI2, PbI2, PbO, CdTe, CdZnTe가 연구 되고 있다. 이러한 후보 물질들 중 본 연구에서는 PVD (Physical Vapor Deposition)방식을 이용하여 Polycrystalline CdTe 박막을 제작하고 특성 향상을 위해 유전물질을 Passive layer와 Protect layer로써 증착하였다. 또한 유전체층의 위치에 따른 특성 분석을 위해 제작된 박막은 FE-SEM (Field Emission Scanning Electron Microscope), XRD (X-ray Diffraction)을 통해 구조적인 특성을 확인하였다. 그리고 입사되는 X-ray 선량에 의해 생성되는 전기적 특성을 분석하였다, 그 결과 박막의 Grain Size는 약 $5{\mu}M$이며 (111)방향의 주 peak를 띄는 Poly CdTe형태로 증착된 것을 확인하였다. 전기적인 신호 결과 Passive layer와 Protect layer를 증착한 박막 모두 Darkcurrent가 감소된 것을 확인하였다. 또한 Sensitivity 측정 결과 Passive layer를 삽입한 경우 신호 값이 감소하였으며 Protect layer를 삽입한 경우 신호 값의 변화가 일어나지 않았다. 그러므로 Protect layer를 등착한 박막의 경우 SNR이 현저히 높아지는 결과를 낳았다.

  • PDF

Interface Engineering in Superconducting Ultra-thin Film of Ga (Ga 극초박막의 계면특성과 초전도 물성제어에 대한 연구)

  • Lee, Nyun-Jong;Kim, Tae-Hee
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.6
    • /
    • pp.212-215
    • /
    • 2010
  • Spin polarized tunneling studies were carried out with Al-Ga bilayer as a spin detector, by Meservey-Tedrow technique. The superconductor (SC)/Insulator (I)/Ferromagnet (FM) tunnel junctions were provided by ultra high vacuum molecular beam epitaxy (UHV-MBE) technique. The analysis of interfacial properties in the Al-Ga bilayer was also carried out by Auger electron spectroscopy. It was observed that the superconducting transition temperature and energy gap were raised in comparison with that of bulk Ga and pure ultrathin Al films. Current studies clearly show how one can modify the material properties at the interface just with a few monolayers.

Radiation protective qualities of some selected lead and bismuth salts in the wide gamma energy region

  • Sayyed, M.I.;Akman, F.;Kacal, M.R.;Kumar, A.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.860-866
    • /
    • 2019
  • The lead element or its salts are good radiation shielding materials. However, their toxic effects are high. Due to less toxicity of bismuth salts, the radiation shielding properties of the bismuth salts have been investigated and compared to that of lead salts to establish them as a better alternative to radiation shielding material to the lead element or its salts. The transmission geometry was utilized to measure the mass attenuation coefficient (${\mu}/{\rho}$) of different salts containing lead and bismuth using a high-resolution HPGe detector and different energies (between 81 and 1333 keV) emitted from point sources of $^{133}Ba$, $^{57}Co$, $^{22}Na$, $^{54}Mn$, $^{137}Cs$, and $^{60}Co$. The experimental ${\mu}/{\rho}$ results are compared with the theoretical values obtained through WinXCOM program. The theoretical calculations are in good agreement with their experimental ones. The radiation protection efficiencies, mean free paths, effective atomic numbers and electron densities for the present compounds were determined. The bismuth fluoride ($BiF_3$) is found to have maximum radiation protection efficiency among the selected salts. The results showed that present salts are more effective for reducing the intensity of gamma photons at low energy region.

The analysis of Residual Pesticides and Sulfur Dioxide in Commercial Medicinal Plants (유통 한약재의 잔류농약 및 잔류이산화황의 함량 분석)

  • Kim, Tae Hee;Jang, Seol;Lee, Ah Reum;Lee, A Young;Choi, Goya;Kim, Ho Kyung
    • The Korea Journal of Herbology
    • /
    • v.27 no.6
    • /
    • pp.43-48
    • /
    • 2012
  • Objectives : This study was investigated to determine the contents of pesticide residues and sulfur dioxide residues in commercial herbal medicines in Korea. Methods : Chromatographic test was performed on 100 samples consisted with 10 kinds of medicinal plants including improted and domestic products. To establish 19 pesticide residues (DDE, DDD, DDT, Dieldrin, Methoxychlor, BHC isomers, Aldrin, Endosulfan isomers, Endrin, Captan, Procymidone, Chlorpyrifos and Imidacloprid) in commercial herbal medicines, chromatographic equipments were used with the gas chromatography-mass detector and gas chromatography-electron capture detector for qualitative analysis. The imidacloprid analysis was performed by high performance liquid chromatograpgy-ultraviolet detector at 270 nm UV wavelength. The contents of sulfur dioxides were analyzed by modified Monnier-Williams method. All methods were based on notification procedure of Korea Food & Drug Administration (KFDA). Results : The residual pesticides were not founded in improted and domestic samples. Among 100 samples, the residues of sulfur dioxide in 73 samples were not detected and 25 samples showed contents in the range of 0~21.90 mg/kg. The excess samples of MRLs were 2 samples (30 mg/kg to medicinal herbs), Asiasari Radix et Rhizoma (Imported product) and the average amount of sulfur dioxide in 2 unsuitable samples were 14.83 mg/kg. These samples were found to transgress KFDA regulatory guidance of residual sulfur dioxide. Conclusion : These results are able to use as basic data to improve the reliability and value of commercial medicinal herbs.

Molecular holographic QSPR analysis on the reactivity between glycine and ninhydrin analogues as latent fingerprints detector (잠재지문 검출제로서 Ninhydrin 유도체들과 Glycine과의 반응성에 관한 분자 홀로그래픽적인 QSPR 분석)

  • Kim, Se-Gon;Jang, Seok-Chan;Cho, Yun-Gi;Hwang, Tae-Yeon;Park, Sung-Woo;Sung, Nack-Do
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.339-346
    • /
    • 2007
  • To search the ninhydrin derivatives that have high chromogenic and fluorogenic properties, molecular holographic quantitative structure property relationship (HQSPR) models on the reactivity between glycine and ninhydrin analogues as latent fingerprint detector were derived and investigated quantitatively. The ${\varepsilon}LUMO$ (e.v.) energy of ninhydrin molecule was an important factor to reactivity of ninhydrin. And, it is suggested that the nucleophilic reaction by orbital-controlled reaction from the frontier molecular orbital (FMO) interaction between glycine and ninhydrin derivatives was more superior than that of electrophilic reaction by charged controlled reaction. The analytical results in atomic contribution maps also shows that the reactivity of ninhydrin was increased by meta-substituents as strong electron withdrawing groups on the benzo ring. Therefore, it is sugested by HQSPR and QSPR model that the 5,6-dinitroninhydrin molecule would increase the reactivity as much as three times as compared to none substituted ninhydrin molecule.

Introduction of Dental X-ray Imaging with New Concept - intra Oral x-ray Tube (신개념 치과용 X-선 영상장치 소개 - 강내형 X-선 튜브)

  • Cho, Sung-Ho;Kim, Dong-Young;Baek, Kwang-Woo;Lee, Re-Na
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.94-101
    • /
    • 2011
  • Various kinds of medical imaging devices have been studied to develop periapical radiography. However, there are some problems such as high x-ray exposure rate and pains for patients because of the problems caused by intra-oral sensor based radiography system. In this study, a new concept of periapical radiography, intra oral X-ray tube and detector system, is introduced to solve these problems. This system is made up of miniature X-ray tube based on subminiature thermal electron or cold electron, CMOS based detector, and a body including automatic position and system control devices. In order to confirm the possibility of proposed new concept to periapical radiography, miniature x-ray tube from XOFT corporation is used to develop new x-ray system, and the performance evaluation of this system is performed according to collimator. Also, dental images are compared after acquiring both images from existing system versus new concept of system. As a result, new concept of system showed excellent image. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.