• Title/Summary/Keyword: Electron beam irradiation

Search Result 460, Processing Time 0.032 seconds

Comparison of Irradiated Food with Electron Beam and Gamma-ray by PSL and TL Methods (광자극발광법과 열발광법 분석을 통한 전자선과 감마선 조사식품의 비교 연구)

  • Kim, Kyu-Heon;Kwak, Ji-Young;Yoon, Jin-Ho;Park, Young-Eun;Lee, Jae-Hwang;Park, Yong-Chjun;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.258-266
    • /
    • 2013
  • This study was conducted to determine the PSL and TL properties of foods irradiated with electron beam and gamma-ray. 5 kinds of food including cereal, pulse, fish powder, dried vegetable and tea were irradiated at 0 to 10 kGy by electron beam accelerator or $^{60}Co$ gamma-ray irradiator. The PSL analysis showed negative results for most of the non-irradiated samples. Non-irradiated shrimp powder showed intermediate result. Irradiated samples gave negative or intermediate or positive value which presented the limitation of PSL technique. In TL analysis, there were TL glow curves at around $300^{\circ}C$ with low intensity on non-irradiated samples. Maximum peak in the range of $150-250^{\circ}C$ was appeared on irradiated samples. TL ratio obtained by re-irradiation with 1 kGy was less than 0.1 on non-irradiated samples and higher than 0.1 on irradiated samples. Therefore, in PSL measurement, electron-beam irradiated samples could obtain more clear results. TL analysis showed obvious difference between non-irradiated and irradiated samples. But the identification was impossible for the sample of rice and lemon tea. Because of it's low contents of mineral.

Analysis of the Volatile Flavor Components in Plum ($Prunus$ $salicina$) Irradiated with an Electron Beam (전자선 조사한 자두의 휘발성 유기성분 변화)

  • Jeong, In-Seon;Lee, Sun-Im;Jeon, Dong-Bok;Hong, Young-Sin;Kim, Jae-Sung;Choi, Sung-Hwa;Nho, Eun-Yeong;Choi, Ji-Yeon;Kim, Byung-Sook;Kim, Kyong-Su
    • Food Science and Preservation
    • /
    • v.19 no.2
    • /
    • pp.249-256
    • /
    • 2012
  • The changes in the volatile organic compounds in plum after its electron beam irradiation and storage were determined using the simultaneous distillation extraction method and gas chromatograph-mass spectrometry. There were 44, 46, 45, 47, and 38 volatile compounds in the 0-, 0.25-, 0.5-, 0.75-, and 1 kGy irradiated samples, respectively. Also, the volatile flavor components of the plum that was stored for 30 days were identified as 48, 40, 40, 39, and 40 components. The compositions of the volatile compounds of the control and irradiated samples showed a similarity after the storage. Especially, the more important volatile flavor of the plum was identified as hexanal of the C6compounds, (E)-2-hexenal and (Z)-3-hexenal. In particular, hexanal, (E)-2-hexenal, and (Z)-3-hexen-1-ol increased in all the doses, where as hexanol and (E)-2-hexen-1-ol decreased. Among the lactone compounds, ${\gamma}$-hexalactone, ${\gamma}$-octalactone, and ${\gamma}$-decalactone were identified during the storage period in the raw samples. Hexanonic acid and 2-hexenoic acid were not identified during the storage of the samples, and 2-methylprrole was detected only when the storage samples were irradiated at a dose higher than 0.5kGy. Therefore, it was shown that there was no effect on the variation of the volatile organic component suntil 1 kGy in the plum was irradiated with an electron beam.

Granulocytic Sarcoma: Results of Radiotherapy (Granulocytic Sarcoma : 방사선 치료 성적)

  • Song Mi Hee;Chung Eun Ji;Seong Jin Sil;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.261-266
    • /
    • 1992
  • We analyzed retrospectively the patients of granulocytic sarcoma treated with radiotherapy at the Department of Radiation Oncology, Yonsei University College of Medicine from Mar 1987 to Mar.1992 in an attempt to review our experience with irradiation of granulocytic sarcoma and to evaluate the treatment results for the radiation dose response. Fourteen lesions of granulocytic sarcoma in 9 patients were developed in variable clinical settings such as AML, CML and without leukemia. The involved lesions were bone, lymph node, soft tissue and skin in descending order of occurrence. All of the lesions in 9 patients were treated with external beam radiotherapy (Co-60 or electron beam). Both age distribution and clinical settings did not show any correlation with the response to treatment. The response to treatment seemed to be better for lesions in the bone than in other involved lesions. The majority received local irradiation of a total dose of more than 2000 cGy. Radiation dose of more than 2000 cGy showed excellent local control of $100\%$, (11/11), while local control decreased to $33\%$(1/3) with total dose less than 2000 cGy. In conclusion, local radiotherapy seems to be very effective for palliative or curative aim of granulocytic sarcoma, and a radiation dose more than 2000 cGy is highly recommended.

  • PDF

DIAGNOSTICS OF PLASMA INDUCED IN Nd:YAG LASER WELDING OF ALUMINUM ALLOY

  • Kim, Jong-Do;Lee, Myeong-Hoon;Kim, Young-Sik;Seiji Katayama;Akira Matsunawa
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.612-619
    • /
    • 2002
  • The dynamic behavior of Al-Mg alloys plasma was very unstable and this instability was closely related to the unstable motion of keyhole during laser irradiation. The keyhole fluctuated both in size and shape and its fluctuation period was about 440 ${\mu}{\textrm}{m}$. This instability has been estimated to be caused by the evaporation phenomena of metals with different boiling point and latent heats of vaporization. Therefore, the authors have conducted the spectroscopic diagnostics of plasma induced in the pulsed YAG laser welding of Al-Mg alloys in air and argon atmospheres. In the air environment, the identified spectra were atomic lines of Al, Mg, Cr, Mn, Cu, Fe and Zn, and singly ionized Mg line, as well as strong molecular spectrum of AlO, MgO and AIH. It was confirmed that the resonant lines of Al and Mg were strongly self-absorbed, in particular in the vicinity of pool surface. The self-absorption of atomic Mg line was more eminent in alloys containing higher Mg. These facts showed that the laser-induced plasma was relatively a low temperature and high density metallic vapor. The intensities of molecular spectra of AlO and MgO were different each other depending on the power density of laser beam. Under the low power density irradiation condition, the MgO band spectra were predominant in intensity, while the AlO spectra became much stronger in higher power density. In argon atmosphere the band spectra of MgO and AlO completely vanished, but AlH molecular spectra was detected clearly. The hydrogen source was presumably the hydrogen solved in the base Metal, absorbed water on the surface oxide layer or H$_2$ and $H_2O$ in the shielding gas. The temporal change in spectral line intensities was quite similar to the fluctuation of keyhole. The time average plasma temperature at 1 mm high above the surface of A5083 alloy was determined by the Boltzmann plot method of atomic Cr lines of different excitation energy. The obtained electron temperature was 3, 280$\pm$150 K which was about 500 K higher than the boiling point of pure aluminum. The electron number density was determined by measuring the relative intensities of the spectra1lines of atomic and singly ionized Magnesium, and the obtained value was 1.85 x 1019 1/㎥.

  • PDF

High Resolution TEM Observations in $Hg_{1-x}\;Tl_{x}\;Ba_{2}(Ca_{0.86}\;Sr_{0.14})_{2}\;Cu_{3}\;O_{8+\delta}$ Superconductors (고온 초전도체 $Hg_{1-x}\;Tl_{x}\;Ba_{2}(Ca_{0.86}\;Sr_{0.14})_{2}\;Cu_{3}\;O_{8+\delta}$의 고분해능 TEM에 의한 구조 관찰)

  • Lee, Hwack-Joo;Ryu, Hyun;Hur, Nam-H.;Park, Yong-K.
    • Applied Microscopy
    • /
    • v.25 no.4
    • /
    • pp.124-131
    • /
    • 1995
  • High resolution transmission electron microscopic observations on the $Hg_{1-x}\;Tl_{x}\;Ba_{2}(Ca_{0.86}\;Sr_{0.14})_{2}\;Cu_{3}\;O_{8+\delta}$(x=0.00, 0.25, 0.50, 0.75) were carried out using side-entry type TEM working at 300 kV. The TEM samples are prepared by powder method. The pellets are crushed in agatar motar and suspended in $CCl_4$, solution and scooped in holely carbon microgrid. The 1223 structures are observed in all samples with [010] zone axis. Except x=0.25 sample, the lattice parameter a and c tend to decrease as the thallium contents are increased ranging from 0.3936 nm to 0.3713 nm for a, and from 1.6131 nm to 1.5138 nm for c parameter. Those of x=0.25 sample are reduced too much, 0.3785 nm for a, 1.5375 nm for c. The sample with x=0.25 shows the intergrowth of 1223 and 1234 structure with the ratio of 19 to 1. As the thallium content increases, the structures become more stable without having any defect. The samples are damaged by electron beam irradiation during the observation, however the structure can endure longer as the thallium contents are increased.

  • PDF

Defect center of $Li^{+}$ ion implanted $Al_2O_3$ ($Li^{+}$ 이온 주입된 $Al_2O_3$의 결함 특성)

  • Kim, Tae-Kyu
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.13-20
    • /
    • 1994
  • The thermoluminescence(TL) glow curves and the optical absorption of $Al_2O_3$ irradiated with ${\gamma}$-ray, electron, and $Li^{+}$ ion followed by electron irradiation have been investigated to determine the relation of TL peak to its defect type. The TL glow curve of $Al_2O_3$ irradiated with ${\gamma}$-ray shows TL peaks at 380 K, 415 K, and 475 K. The UV photobleached TL glow curve of $Al_2O_3$ irradiated with ${\gamma}$-ray shows that the 380 K and 475 K TL peaks completely disappear while the 415 K TL peak still exists. The electron beam induced TL glow curve of $Al_2O_3$ after $Li^{+}$ ion implantation shows that the TL peak at 440 K is enhanced by a factor of 2 over the TL intensity of unimplanted $Al_2O_3$ while the TL peak at 380 K evidently disappears The implanted $Li^{+}$ ions are assumed to form singly charged interstitial cations and then recombine with electron trapped in F centers to produce F+ centers. The 380 K and 475 K TL peaks are proposed to be associated with F center, while the 415 K and 440 K TL peak are connected with F$^{+}$ center.

  • PDF

Observations on the Modulated Structure in Pyrochlore-type Compounds, $In_2(Ti_{1.7}Zn_{0.3})O_{0.67}$ and $In_2(Ti_{1.7}Mg_{0.3})O_{6.7}$ (Pyrochlore형 화합물 $In_2(Ti_{1.7}Zn_{0.3})O_{0.67}$$In_2(Ti_{1.7}Mg_{0.3})O_{6.7}$에서의 변조구조 관찰)

  • Lee, Hwack-Joo;Park, Hyun-Min;Cho, Yang-Koo;Ryu, Hyun;Nahm, Sahn;Bando, Y.
    • Applied Microscopy
    • /
    • v.29 no.4
    • /
    • pp.471-477
    • /
    • 1999
  • Microstructural observations on the pyrochlore-type $Lu_2Ti_2O_7$ and the similar type of compounds, $In_2(Ti_{1.7}Zn_{0.3})O_{6.7}$ and $In_2(Ti_{1.7}Mg_{0.3})O_{6.7}$ which were made by the isothermal heat-treatment at 1623K for 18 days in Pt tube, were carried out using a top-entry HRTEM working at 200 kV. The modulated structures were found in both compounds, however, not in $Lu_2Ti_2O_7$. From the electron diffraction pattern analysis, the modulated superlattices are incommensurate and are 2.69 times of sublattices along (220) direction. The high resolution TEM images have shown that the superlattices consist of alternate superlattices which are composed of two or three sublattices, resulting in the average of 2.7 times of sublattices in accordance with the analysis of electron diffraction patterns. The crystal structures of both compounds are found to quite similar to those of pyrochlore, however the evidence that the cubic axes are slightly deviated from right angle. The modulated structure has gradually changed to the unmodulated structure induced by electron irradiation.

  • PDF

Pre-Irradiation Grafting of Acrylic Acid onto Polyethylene Film (전조사법에 의한 아크릴산의 폴리에틸렌 필름에 대한 그라프트 반응)

  • Nho, Young Chang;Jin, Joon-Ha;Lee, Myun Zu
    • Applied Chemistry for Engineering
    • /
    • v.7 no.1
    • /
    • pp.75-82
    • /
    • 1996
  • Acrylic acid was graft-copolymerized on polyethylene film in the presence of additives such as acid and $FeSO_4(NH_4)_2SO_4{\cdot}6H_2O$ using peroxide grafting technique by ${\gamma}$-ray and electron beam, and the effect of $FeSO_4(NH_4)_2SO_4{\cdot}6H_2O$ and acid on the grafting yield was evaluated. The grafting mechanism and the physical property of grafted films were also examined. The results showed that the inclusion of $FeSO_4(NH_4)_2SO_4{\cdot}6H_2O$ in acidified acrylic acid grafting solution was extremely beneficial and led to a most unusual enhancement effect in the radiation grafting. In the other hand, inclusion of mineral acid in the grafting solution in the absence of $FeSO_4(NH_4)_2SO_4{\cdot}6H_2O$ could not lead to he suitable grafting reaction by the severe homopolymerization of acrylic acid. The addition of $H_2SO_4$, and HCl led to much higher grafting yield than $HNO_3$and $CH_3COOH$. It was shown that grafting yield of ${\gamma}$-ray irradiated-polyethylene was higher than that of electron beam irradiated polyethylene.

  • PDF

Photostimulated Luminescence-Thermoluminescence Application to Detection of Irradiated White Ginseng Powder (방사선 조사 백삼분말의 PSL-TL 다중검지법)

  • Chung, Hyung-Wook;Delincee, Henry;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.265-270
    • /
    • 2000
  • White ginseng powder, permitted to be irradiated in Korea for the purpose of microbial decontamination, was treated with electron beam at doses of $0{\sim}15\;kGy$ for a detection trial whether it is irradiated or not by measuring photostimulated luminescence for whole samples first and then (TL) for the mineral adhering to the samples. PSL values were less than threshold value (700, $T_{1}$) and were negative for nonirradiated samples but more than 5000 $(T_2)$ and were positive for irradiated ones. After PSL measurement mineral was separated from the whole samples using density separation. Mineral of nonirradiated samples was characterized by glow curves which have low intensity and were situated at the high temperature region (about $300^{\circ}C$) by the low level of natural radioactivity. Glow curves of minerals for all irradiated samples were observed at about $200^{\circ}C$. TL ratio by normalization was 0.01 for nonirradiated sample and more than 0.78 for irradiated samples, and it was possible to detect whether white ginseng powders were irradiated or not.

  • PDF

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.