• Title/Summary/Keyword: Electron Flow

Search Result 675, Processing Time 0.02 seconds

Noninvasive Evaluation of Coronary Artery Bypass Graft Patency by Electron Beam Tomography (전자선 단층 촬영을 이용한 관상동맥 우회로 개존의 비침습적 평가)

  • 최규옥;김호석;조범구
    • Journal of Chest Surgery
    • /
    • v.32 no.8
    • /
    • pp.693-701
    • /
    • 1999
  • Recently non-invasive diagnostic imaging replaced the invasive catheter angiography in the diagnosis of vascular disease. Catheter methods are now almost confined to the purpose of intervention. Coronary artery or coronary artery bypass graft still needs catheter technique because of small diameter and the cardiac motion. The last challenge for radiologists in this domain is to obtain a non-invasive imaging. Electron beam tomography(EBT) for high temporal resolution is able to obtain a coronary arteriogram or coronary artery bypass graft (CABG), of which CABG imaging is quite useful for the evaluation of patency. In our experience as well as others, the accuracy of EBT angiogram in evaluating CABG patency revealed that the accuracy of patency of saphenous vein grafts(SVG) is high due to relatively wide lumen, short and straight course and less influence from cardiac motion. The sensitivity and specificity of patency of SVGs were 92%, 97% respectively in the prospective evaluat on and 100% each in the retrospective evaluation. A false positive and a false negative case are rudimentary errors in the initial learing period. In contrast the analysis of left internal mammary artery(LIMA) graft was difficult due to the inherent small size and the adjacent surgical clips provoking beam-hardening artifact; therefore, the method of combining 3 dimensional reconstruction and flow mode study was important in improving the accuracy of LIMA patency. The sensitivity and specificity of LIMA patency were 100% and 80% in both prospective and retrospective evaluation. Therefore, EBT angiography is an accurate non-invasive diagnostic modality for evaluating the patency of CABG, particularly in SVGs. The accuracy can be improved with the improvement of the EBT and the development of the image reconstruction software.

  • PDF

Characteristics of silicon etching related to $He-O_2,\; SiF_4$for trench formation (실리콘 트렌치 식각 특성에 미치는 $He-O_2,\; SiF_4$첨가 가스의 영향)

  • 김상기;이주욱;김종대;구진근;남기수
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.4
    • /
    • pp.364-371
    • /
    • 1997
  • Silicon trench etching has been carried out using a magnetically enhanced reactive ion etching system in HBr plasma containing He-$O_2$, $CF_4$. The changes of etch rate and etch profile, the degree of residue formation, and the change of surface chemical state were investigated as a function of additive gas flow rate. A severe lateral etching was observed when pure HBr plasma was used to etch the silicon, resulted in a pot shaped trench. When He-$O_2$, $SiF_4$ additives were added to HBr plasma, the lateral etching was almost eliminated and a better trench etch profile was obtained. The surface etched in HBr/He-$O_2/SiF_4$ plasma showed relatively low contamination and residue elements compared to the surface etched in HBr/He-$O-2/CF_4$plasma. In addition, the etching characteristics including low residue formation and chemically clean etched surface were obtained by using HBr containing He-$O_2$ or $SiF_4$ additive gases instead of $CF_4$ gas, which were confirmed by X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and atomic force microscopy (AFM).

  • PDF

Improved Electrical Properties by In Situ Nitrogen Incorporation during Atomic Layer Deposition of HfO2 on Ge Substrate (Ge 기판 위에 HfO2 게이트 산화물의 원자층 증착 중 In Situ 질소 혼입에 의한 전기적 특성 변화)

  • Kim, Woo-Hee;Kim, Bum-Soo;Kim, Hyung-Jun
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.14-21
    • /
    • 2010
  • Ge is one of the attractive channel materials for the next generation high speed metal oxide semiconductor field effect transistors (MOSFETs) due to its higher carrier mobility than Si. But the absence of a chemically stable thermal oxide has been the main obstacle hindering the use of Ge channels in MOS devices. Especially, the fabrication of gate oxide on Ge with high quality interface is essential requirement. In this study, $HfO_xN_y$ thin films were prepared by plasma-enhanced atomic layer deposition on Ge substrate. The nitrogen was incorporated in situ during PE-ALD by using the mixture of nitrogen and oxygen plasma as a reactant. The effects of nitrogen to oxygen gas ratio were studied focusing on the improvements on the electrical and interface properties. When the nitrogen to oxygen gas flow ratio was 1, we obtained good quality with 10% EOT reduction. Additional analysis techniques including X-ray photoemission spectroscopy and high resolution transmission electron microscopy were used for chemical and microstructural analysis.

Study on Radioprotection of Alliin and Damage Mechanism in Hepatocyte After Irradiation (방사선 피폭 시 간세포의 손상 기전과 알리인의 방어효과)

  • Ji, Tae-Jeong;Kim, Won-Tae
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.623-630
    • /
    • 2016
  • Liver tissue damage by a radiation exposure caused a jaundice and ascitic fluid e form harden atrophy. The reason for this lies in morphological damage of a liver cells. This study tried that observe damage mechanism of the cell organelles. It was especially observed mitochondria, endoplasmic reticulum and nuclear membrane associated with energy metabolizable. also, This study had with a radio-protector development research at the same time. Radio-protector was used to alliin that has an blood flow increase. Cell observation make used of transmission electron microscope(TEM). The result of an experiment, 7Gy of whole body irradiation was caused an inflammation in cell organelles and hypertrophy of the nucleus membrane. After 20 days, The hepatocyte has been observed in a damaged membrane on peroxisome, mitochondria and vacuole of the cell organelles. After 30 days, The hepatocyte has been observed in disconnected ribosomes on a rough endoplasmic reticulum. There was looked a giant lipoblast. There was clearly normal observed a mitochondria and nucleus membrane in the hepatocyte after alliin injection. aslo, It was no damaged the nucleus membrane. therefore, It was identified portion a radio-protector effect from alliin.

Synthesis of High-Quality Single-Walled Carbon Nanotube Fibers by Vertical CVD (수직 가열로를 이용한 고순도 단일벽 탄소나노튜브 섬유의 합성)

  • Kim, Tae-Min;Song, Woo-Seok;Kim, Yoo-Seok;Kim, Soo-Youn;Choi, Won-Chel;Park, Chong-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.5
    • /
    • pp.377-384
    • /
    • 2010
  • Many routes have been developed for the synthesis of signle-walled carbon nanotubes (SWCNTs). We spun fibers of SWCNTs directly from vertical furnace using a liquid source of carbon and an iron-contained molecule. The solution was prepared by ethanol as a carbon source, in which ferrocene as a catalyst, thiophene were dissolved. It was then injected from the top of the furnace into hot zone with hydrogen as a carrier gas. We successfully synthesized high-quality SWCNTs by adjusting the various experimental conditions, such as concentration of ferrocene, solution injection rate, concentration of thiophene, and hydrogen flow rate. Measurement of Raman spectroscopy, scanning electron microscopy, and transmission electron microscopy were carried out to find the optimized conditions. The synthesized SWCNTs (1.16~1.64 nm) appeared a bundle structure and well-aligned parallel to the direction of furnace. These results also provide an simple way for high-quality SWCNTs mass production and fabricating direct spining SWCNTs fiber. It will allow one-step production of SWCNTs fiber with potentially excellent properties and wide-range applications.

Biomimetic Analysis on the Spider Silk Apparatus for Designing the Nanofiber-spinning Nozzle (나노섬유 방사노즐 설계를 위한 거미 실크 방적장치의 생체모사 분석)

  • Moon, Myung-Jin;Kim, Hoon;Park, Jong-Gu
    • Applied Microscopy
    • /
    • v.42 no.2
    • /
    • pp.67-76
    • /
    • 2012
  • The biomimetic approach on the cuticular spinning nozzles of the major ampullate silk glands in the golden-web spider Nephila calvata has been attempted using various visualizing techniques of light and electron microscopes to improve the design of spinning nozzle for producing synthetic nanofibers spun from electrospinning apparatus. The major ampullate spigot which has the most effective nozzle system to produce nanofibers for dragline silk with high strength and elasticity is connected via the bullet type spigot on anterior spinneret with flexible terminal segment. The excretory duct which transports the liquid silk feedstock from ampulla to spigot is divided into 3 limbs by loops back on itself to form an S-shape morphology that is bundled in connective tissue. Final diameter of the nanofibers at nozzle was dramatically reduced by gradual narrowing of duct cuticle less than 10 times comparing to its original size of funnel region. Moreover, the funnel has a characteristic cuticular organization with porous microstructure which seems to be related to water removal from feedstock of silk precursors. High magnification electron micrographs also reveal the presence of the spiral grooves on the surface of the cuticular intima near the valve which presumed to reduce friction during rapid flow of liquid silk.

Characterization of Cold Hollow Cathode Ion Source by Modification of Electrode Structure (전극 구조 변화에 따른 Cold Hollow Cathode Ion Source의 특성 변화)

  • Seok, Jin-Woo;Chernysh, V.S.;Han, Sung;Beag, Young-Hwoan;Koh, Seok-Keun;Yoon, Ki-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.10
    • /
    • pp.967-972
    • /
    • 2003
  • The inner-diameter 5 cm cold hollow cathode ion source was designed for the high current density and the homogeneous beam profile of ion beam. The ion source consisted of a cylindrical cathode, a generation part of magnetic field, a plasma chamber, convex type ion optic system with two grid electrode, and DC power supply system. The cold hollow cathode ion sources were classified into standard type (I), electron output electrode modified type (II). The operation of the ion source was done with discharge current, ion beam potential and argon gas flow rate. The modification of electron output electrode resulted in uniform plasma generation and uniform area of ion beam was extended from 5 cm to 20 cm. Improved ion source was evaluated with beam uniformity, ion current, team extraction efficiency, and ionization efficiency.

CFD Explanation and Verification of Multi Inner Stage Cyclone for The Particle Removal (미세입자 제거를 위한 Multi Inner Stage Cyclone의 CFD 해석 및 검증)

  • Lee, Sang Jun;Kim, Chun-Lee;Lee, Won Joo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.1
    • /
    • pp.149-156
    • /
    • 2013
  • In this paper, Commercial program, STAR-CCM+, was used for computer simulation. And also Multi Inner Stage(MIS) cyclone which especially designed for the real experiments of particle removal efficiency. Under negative pressure condition of outlet, computer simulation was performed to predict the removal efficiency for $5{\mu}m$ and $10{\mu}m$ particles by using a turbulence model and lagrangian method. The simulation results are 55.7% and 64.1% for $5{\mu}m$ and $10{\mu}m$ particles, respectively. To compare the simulation results with the actual test of MIS cyclone, we generated the $SiO_2$ particles by heat reactor. Although removal efficiency of actual tests is 63~76% at different flow rate, the size of $SiO_2$ particles which confirmed by SEM(scanning electron microscope) and WAPS(wide range aerosol particle spectrometer) is too small(15~30nm) to compare each results. And so the alternative experiments were performed by using commercial alumina particles ($5{\mu}m$, $10{\mu}m$ and $20{\mu}m$). It was shown that the actual removal efficiency, 76~95%, from MIS cyclone is higher than simulated one.

IMPLICATION OF STELLAR PROPER MOTION OBSERVATIONS ON RADIO EMISSION OF SAGITTARIUS A

  • CHANG HEON-YOUNG;CHOI CHUL-SUNG
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.81-87
    • /
    • 2003
  • It is suggested that a flying-by star in a hot accretion disk may cool the hot accretion disk by the Comptonization of the stellar emission. Such a stellar cooling can be observed in the radio frequency regime since synchrotron luminosity depends strongly on the electron temperature of the accretion flow. If a bright star orbiting around the supermassive black hole cools the hot disk, one should expect a quasi-periodic modulation in radio, or even possible an anti-correlation of luminosities in radio and X-rays. Recently, the unprecedentedly accurate infrared imaging of the Sagittarius A$\ast$ for about ten years enables us to resolve stars around it and thus determine orbital parameters of the currently closest star S2. We explore the possibility of using such kind of observation to distinguish two quite different physical models for the central engine of the Sagittarius A$\ast$, that is, a hot accretion disk model and a jet model. We have attempted to estimate the observables using the observed parameters of the star S2. The relative difference in the electron temperature is a few parts of a thousand at the epoch when the star S2 is near at the pericenter. The relative radio luminosity difference with and without the stellar cooling is also small of order $10^{-4}$, particularly even when the star S2 is near at the pericenter. On the basis of our findings we tentatively conclude that even the currently closest pass of the star S2 is insufficiently close enough to meaningfully constrain the nature of the Sagittarius A$\ast$ and distinguish two competing models. This implies that even though Bower et al. (2002)have found no periodic radio flux variations in their data set from 1981 to 1998, which is naturally expected from the presence of a hot disk, a hot disk model cannot be conclusively ruled out. This is simply because the energy bands they have studied are too high to observe the effect of the star S2 even if it indeed interacts with the hot disk. In other words, even if there is a hot accretion disk the star like S2 has imprints in the frequency range at v $\le$ 100 MHz.

EFFECT OF STEP CURING ON THE CONTRACTION STRESS AND MARGINAL ADAPTATION OF RESIN RESTORATION (단계별 광중합 방식이 복합레진 수복물의 수축 응력과 변연 접합도에 미치는 영향)

  • Park, Jong-Whi;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.221-232
    • /
    • 2006
  • The purpose of this study was to investigate the effect of step-curing mode on polymerization shrinkage and contraction of composite resin restoration. Class I cavities were prepared on the extracted human premolars. The cavities were ailed with Filtek $Z-250^{TM}$ (hybrid resin, 3M ESPE, USA) and Filtek $flow^{TM}$ (flowable resin, 3M ESPE, USA) and cured with one of the following irradiation modes; Halogen 40sec with continuous curing, LED 10sec with continuous curing, and LED 13sec with step-curing. Contraction stress was measured with strain gauge which was connected to TML $Datalogger^{TM}$ (TDS-102, SOKKI, Japan) and resin-dentin interfaces were observed by scanning electron microscope. The results of present study can be summarized as follows : 1. Composite resin restoration showed transient expansion just after irradiation of curing light. Contraction stress was increased rapidly at the early phase of polymerization and reduced slowly as time elapsed (P<0.05) 2. $Filtek\;flow^{TM}$ showed lower contraction stress than Filtek $Z-250^{TM}$ regardless of curing modes. 3. LED step-curing mode showed lowest contraction stress in Filtek $Z-250^{TM}$ compared with other curing modes(P<0.05). 4. LED step-curing mode showed lowest contraction stress in $Filtek\;flow^{TM}$ compared with other curing modes(P<0.05), but difference in contraction stress was not so greate as in $Filtek\;Z-250^{TM}$. 5. Polymerization of composite resin by LED light with step-curing mode and halogen light with continuous ode resulted in better marginal sealing than LED light with continuous mode.

  • PDF