• Title/Summary/Keyword: Electromyographic activity

Search Result 211, Processing Time 0.183 seconds

Relationship between Movements of the Foot and Electromyographic Activities of Lower Leg Muscles in Young Women (젊은 여성의 발동작과 몇몇 하퇴근 근전도와의 관계)

  • Choe, Myoung-Ae;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.18 no.1
    • /
    • pp.81-96
    • /
    • 1984
  • As the crippled persons work mostly in a sitting position and would be engaged in a foot-pressing job, it is necessary to assess their degree of participation of important muscles in various modes of foot activities. In this regard, it deems to be urgent to establish the reference standards for healthy persons. The present study has been undertaken to determine the degree of participation of the M. tibialis anterior, M. gastrocnemius and M. soleus in heel pressing, foot-flat pressing and forefoot pressing motion under varying forces, and in order to compare the electrical activities of three muscles with each other, and to analyse the time sequence between force and appearance or disappearance of EMG recording. Sixty-three healthy young women ranging from age of 18 to 23 were examined. The results obtained were as follows: 1. Participation of three muscles in foot movement under varying forces: A) Both gastrocnemius muscles or left soleus muscle did not contribute to heel pressing motion. Activity of both tibialis anterior muscles was the greatest among three muscles at heel pressing motion and the degree of their activities was proportional to force. B) Activities of left tibialis anterior muscle and both gastrocnemius muscles were negligible under 3 kg force at foot-flat pressing movement. Left gastrocnemius muscle did not contribute to foot-flat pressing under 6 or 9 kg force. Although activities of both soleus muscles and both tibialis anterior muscles were small, the degree of their activities increased with force at foot-flat pressing movement. C) Activities of both tibialis anterior muscles were negligible under 3 kg force at forefoot pressing motion. Activity of both soleus muscles was the greatest among 3 muscles and the degree of their activities increased with force at forefoot pressing motion. Both tibialis anterior muscles participated in forefoot pressing motion with severe exertion. 2. Electrical activities by foot movement under varying forces : A) Electrical activities were prominent in both tibialis anterior muscles and the level of their activities was linear with force at heel pressing motion. The degree of participation of both soleus muscles was small at heel pressing motion. B) Electrical activity of tibialis anterior muscle was the greatest among 3 muscles at foot-flat pressing movement and was followed by that of soleus muscle. Level of electrical activities increased with force in left soleus muscle and right tibialis anterior muscle at foot-flat pressing movement. C) Electrical activity of both soleua muscles was the greatest among 3 muscles at forefoot pressing movement and that of tibialis anterior muscle was next to soleus muscle. Level of electrical activities was proportional to force in left tibialis anterior muscle, right gastrocnemius muscle and both soleus muscles at forefoot pressing movement. 3. Time between starting signal and initiation of contraction of heel pressing and forefoot pressing motion in 3 muscles was longer than that of foot-flat pressing movement. Time of relaxation in 3 muscles was longer than that of contraction under varying forces. EMG recording appeared before initiation of contraction in both tibialis anterior muscles at heel pressing motion and in both soleus muscles at forefoot pressing movement under varying forces. Time of initiation of contraction was similar in both sides of tibialis anterior muscles under varying forces and time of onset of contraction at foot-flat pressing motion was the shortest. 4. Forefoot pressing movement would be encouraged in paralysis of tibialis anterior muscle, while heel pressing motion would be encouraged in paralysis of triceps surae muscle.

  • PDF

The Effects of Strengthening Exercise for the Lower Extremities on Associated Reaction of the Upper Extremities in Patients With Hemiparesis (뇌졸중 편마비 환자에서 하지 근력강화운동이 상지 연합반응에 미치는 영향)

  • Park, Hyung-Ki;Kim, Jong-Man;Kim, Won-Ho
    • Physical Therapy Korea
    • /
    • v.13 no.2
    • /
    • pp.52-60
    • /
    • 2006
  • Muscle weakness in the hemiplegia following stroke is an important factor which determines the quality of life in the future. Therefore, muscle strengthening exercise is essential for functional recovery in hemiplegic patients. Even though the popular conception is that muscle strengthening exercise causes spasticity and associated reaction that hemiplegia patients don't want, and that it disturbs functional recovery, recently there have been many new reports against that opinion. Therefore, the effects of strengthening exercise programs on functional recovery in hemiplegic patients are still controversial. The purpose of this study was to determine the effects of strengthening exercise programs for the knee joint using isokinetic exercise on the associated reaction of the upper extremities. Comparing the muscle activities of biceps brachii and triceps brachii during, before, and immediately after 2 and 5 minute intervals of isokinetic exercise, we examined the increase and decrease of associated reaction. Twenty stroke inpatients participated in this study. Surface electromyography was used to get muscle activity data from biceps brachii and triceps brachii. The major findings of this study were as follows: 1. The flexor and extensor peak torque were significantly higher on the sound side than the affected side (p<.05). 2. Before and after strengthening exercise, there was no significant difference in muscle activities (surface electromyographic root mean square values) between the sound and affected side. 3. Muscle activities were examined during, before, and immediately after 2 and 5 minute intervals of isokinetic exercise. There were significant differences in muscle activities between, before and during the exercises, during exercise and 5 minutes after exercise in the biceps brachii (p<.05), and during exercise and 5 minutes after exercise in the triceps brachii (p<.05). In conclusion, there was no relation between strengthening exercise and associated reaction in the upper extremities. Rather, muscle activities after exercise had a tendency to decrease relative to before the exercise. Thus, it is considered that intensive strengthening exercise contributes to improvement of functional recovery without increase in associated reaction in hemiparetic patients.

  • PDF

Physiologic Phonetics for Korean Stop Production (한국어 자음생성의 생리음성학적 특성)

  • Hong, Ki-Hwan;Yang, Yoon-Soo
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.17 no.2
    • /
    • pp.89-97
    • /
    • 2006
  • The stop consonants in Korean are classified into three types according to the manner of articulation as unaspirated (UA), slightly aspirated (SA) and heavily aspirated (HA) stops. Both the UA and the HA types are always voiceless in any environment. Generally, the voice onset time (VOT) could be measured spectrographically from release of consonant burst to onset of following vowel. The VOT of the UA type is within 20 msec of the burst, and about 40-50 msec in the SA and 50-70 msec in the HA. There have been many efforts to clarify properties that differentiate these manner categories. Umeda, et $al^{1)}$ studied that the fundamental frequency at voice onset after both the UA and HA consonants was higher than that for the SA consonants, and the voice onset times were longest in the HA followed by the SA and UA. Han, et $al^{2)}$ reported in their speech synthesis and perception studies that the SA and UA stops differed primarily in terms of a gradual versus a relatively rapid intensity build-up of the following vowel after the stop release. Lee, et $al^{3)}$ measured both the intraoral and subglottal air pressure that the subglottal pressure was higher for the HA stop than for the other two stops. They also compared the dynamic pattern of the subglottal pressure slope for the three categories and found that the HA stop showed the most rapid increase in subglottal pressure in the time period immediately before the stop release. $Kagaya^{4)}$ reported fiberscopic and acoustic studies of the Korean stops. He mentioned that the UA type may be characterized by a completely adducted state of the vocal folds, stiffened vocal folds and the abrupt decreasing of the stiffness near the voice onset, while the HA type may be characterized by an extensively abducted state of the vocal folds and a heightened subglottal pressure. On the other hand, none of these positive gestures are observed for the SA type. Hong, et $al^{5)}$ studied electromyographic activity of the thyroarytenoid and posterior cricoarytenoid (PCA) muscles during stop production. He reported a marked and early activation of the PCA muscle associated with a steep reactivation of the thyroarytenoid muscle before voice onset in the production of the HA consonants. For the production of the UA consonants, little or no activation of the PCA muscle and earliest and most marked reactivation of the thyroarytenoid muscle were characteristic. For the SA consonants, he reported a more moderate activation of the PCA muscle than for the UA consonant, and the least and the latest reactivation of the thyroarytenoid muscle. Hong, et $al^{6)}$ studied the observation of the vibratory movements of vocal fold edges in terms of laryngeal gestures according to the different types of stop consonants. The movements of vocal fold edges were evaluated using high speed digital images. EGG signals and acoustic waveforms were also evaluated and related to the vibratory movements of vocal fold edges during stop production.

  • PDF

Effect of Occlusal Stabilization Appliance on Driving Distance in Golf (교합안정장치가 전문골프선수들의 드라이버 비거리에 미치는 영향)

  • Kwon, Tae-Hoon;Shin, Sang-Wan;Ryu, Jae-Jun;Lee, Richard Sung-Bok;Ahn, Su-Jin;Choi, Yeo-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.157-168
    • /
    • 2010
  • Many athletes have been using occlusal stabilization appliances to improve their performance. Few studies have examined the benefits of such an appliance in golf. We determined the effect of such appliances on the masticatory muscle activities and driving distances of professional golf players. The appliances were customized for each player and adjusted using a computerized device. The electromyographic muscle activities and driving distances with and without the appliance were measured and compared using the K7 Analyzer and the GolfAchiever II assembly. A paired t-test was used for statistical analysis. The muscle activities of the temporo-frontal and masseter muscles with the appliance were significantly more stable than those without the appliance, and the driving distances with the appliance were significantly different from those without it. Although there were intra-individual differences, professional golf players with temporomandibular disorders showed a greater improvement in performance.

The Comparison of Trunk Muscle Activities During Sling and Mat Exercise (요부 안정화 운동에 따른 몸통 근육들의 근활성도 비교)

  • Choi, Hee-Soo;Kwon, Oh-Yun;Yi, Chung-Hwi;Jeon, Hye-Seon;Oh, Jae-Seop
    • Physical Therapy Korea
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 2005
  • The purpose of this study was to verify the most effective spinal stabilization exercises program by comparing the activities of muscles contributing to spinal stabilization during four types of exercises using a sling and a mat. Twenty healthy males were recruited and each subjects performed four types of exercises. Exercise 1 was performed in a quadruped position with the subjects lifting the left arm and the opposite leg on the mat. Exercise 2 was performed in a prone position while holding a sling with the right hand and the left knee was fully extended while lifting the left arm and right leg. Exercise 3 was performed in quadruped position while holding a sling with one the right hand and lifting the opposite arm and leg. In exercise 4, subjects were instructed to maintain a balance push-up position while holding slings with both hands in 10 cm forward reaching with extended elbows. Electromyographic(EMG) activities were recorded from the multifidus, external oblique, internal oblique, abdominal rectus, and erector spinalis muscles during the exercises. The EMG amplitude of each muscle was normalized to the amplitude in the maximal voluntary isometric contraction (MVIC) of each muscle. Repeated ANOVA and Bonferroni's tests were used to compare the differences in the muscle activity according to the types of exercise. The EMG amplitudes of all the muscles were significantly different according to the types of exercises (p<.05). The highest EMG activities of each muscle was as follow; multifidus was 73.38%MVIC in exercise 3, the erector spinalis was 40.03%MVIC in exercise 3, the external oblique was 135.88%MVIC in exercise 4, the internal oblique was 128.60%MVIC in exercise 4, and the rectus abdominalis was 95.24%MVIC in Exercise 4. The types of exercises showed a significant difference in composition rate of EMG amplitudes of each muscle (p<.05). EMG composition rate of the multifidus was high in exercise 1 and 3. However, EMG composition rates of the external oblique, internal oblique, and the rectus abdominals were high in exercise 2 and 4. These results showed differences in EMG activities of muscles contributing to trunk stabilization during different therapeutic exercises. Therefore, the type of exercise should be carefully selected to effectively strengthen a specific trunk stabilizer.

  • PDF

CORRELATIONS BETWEEN ORBICULARIS ORIS AND MENTALIS MUSCLE ACTIVITY AND CRANIOFACIAL MORPHOLOGY IN NORMAL OCCLUSION AND CLASS III MALOCCLUSION (정상교합자와 3급 부정교합자에서 구륜근과 턱끝근의 활성과 안면골격 사이의 상관성에 관한 연구)

  • Chang, Chun Sil;Lee, Ki Soo
    • The korean journal of orthodontics
    • /
    • v.22 no.1
    • /
    • pp.253-271
    • /
    • 1992
  • The purpose of this study was to investigate the difference of EMG activity of the Orbicularis oris and Mentalis muscle between normal occlusion and class III malocclusion group during various lip position and to find out whether any correlations exist between the muscular activity and craniofacial morphology. In this study, 50 subjects with a mean age of 22.9 Years (range 20.0-26.0) were investigated (25 subjects were normal occlusion, and 25 subjects were class III malocclusion). EMG data were recorded from the Orbicularis oris and Mentalis muscle during rest lip posture, lip position at maximum biting, lip position at maximum sealing effort, lip position at chewing, swallowing and phonation with the Medelec MS-25 electromyographic machine. Lateral cephalometric radiographs was taken with the mandible in intercuspal position on all subjects. All data were recorded and statistically processed. The findings of this study can be summerized as follows: 1. In normal occlusion, the maximal mean amplitude of upper lip during the lip position at chewing was lower than that of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not statistically different. 2. In Class III malocclusion, the maximal mean amplitude of upper lip during the lip position at chewing, swallowing and phonation was lower than that of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not statistically different. 3. Compare to normal occlusion, the Class III malocclusion was showed low maximal mean amplitude of upper lip during rest lip posture and the lip position at swallowing of saliva, and showed great maximal mean amplitude of lower lip and meantalis muscle during the lip position at chewing and phonation. 4. In normal occlusion, the maximal mean amplitude of upper lip during various lip position was not correlated with the length and thickness of upper lip, but the maximal mean amplitude of lower lip during the lip position at chewing and swallowing was positively correlated with the thickness of lower lip. 5. In Class III malocclusion, the maximal mean amplitude of upper lip during rest lip posture was negatively correlated with the thickness of upper lip, and the maximal mean amplitude of lower lip and mentalis muscle during the lip position at chewing and swallowing was positively correlated with the thickness of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not correlated with the cephalometric measurements of soft tissue. 6. The correlation between the maximal mean amplitude of orbicularis oris and mentalis muscle and cephalometric measurements of incisors was not nearly present. 7. In normal occlusion, the maximal mean amplitude of lower lip and mentalis muscle during the lip position at maximum biting was negatively correlated with the angle between palatal plane and mandibular plane. In Class III malocclusion, the maximal mean amplitude of upper lip, lower lip and mentalis muscle during function was negatively correlated with the length of maxilla, the maximal mean amplitude of upper lip and lower lip during function was negatively correlated with the SNA and SNPo, and the maximal mean amplitude of lower lip during the lip position at chewing was negatively correlated with the ANB.

  • PDF

Effects of Occlusal Condition and Clenching Force on the Mandibular Torque Rotational Movement (교합조건 및 이악물기 힘의 변화가 하악의 비틀림 회전운동에 미치는 영향)

  • Oh, Min-Jung;Han, Kyung-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.411-426
    • /
    • 2005
  • The purpose of this study was to investigate the effects of occlusal condition and clenching level on the mandibular torque rotational movement. For this study, healthy 14 men without any symptoms and signs of temporomandibular disorders were selected. Mandibular torque rotational movement was observed in each circumstance of combination of three occlusal conditions such as natural dentition, with wafer of 3.6 mm thickness, and wafer with resin stop of 14 mm thickness total during hard biting of bite stick at maximum voluntary contraction(MVC) and 50% of MVC level of surface EMG activity of masseter muscle. Electromyographic activity and mandibular torque rotational movement were observed using BioEMG and BioEGN in $BioPak^{(R)}$ system. Each biting movement in each circumstance was composed of clenching one time and hard biting of wooden stick two times. The observed items were opening distance, velocity and amount of torque rotational movement in mandibular movement, and the data were statistically processed with $SPSS^{(R)}$ windows (ver.10.0). The results of this study were as follows: 1. There were no differences in the mandibular movement distance between those value in both biting sides, and between those in both clenching forces, but the mandibular velocity showed a different results by clenching force. For the amount of torque rotational movement, there were no difference in the value of the frontal plane but some significant difference was in the value of the horizontal plane by biting side. 2. The mandibular movement distance and the mandibular velocity in both planes were higher by maximum voluntary contraction than those by half maximum voluntary contraction, and amount of torque rotational movement in the horizontal plane was also increased by maximum voluntary contraction. 3. The opening distance in both planes were decreased with the increase of vertical dimension of occlusion, namely, by the occlusal appliances, and this pattern was also showed in the mandibular velocity in case of hard biting by maximum voluntary contraction. However, the amount of torque rotational movement were not different by the increase of vertical dimension of occlusion. 4. The value of angle and distance of the torque rotational movement in the hard biting of wooden stick were generally higher than those in the clenching without wooden stick in both planes without regard to occlusal conditions and/or clenching forces.

Psychophysiologic Responses to Event Imagery in Traffic Accident Related Patients (교통사고관련 환자에서 사건상상에 대한 정신생리반응)

  • Chung, Sang-Keun;Choi, Myong-Su;Hwang, Ik-Keun
    • Sleep Medicine and Psychophysiology
    • /
    • v.8 no.1
    • /
    • pp.45-51
    • /
    • 2001
  • Objectives: The experience of traffic accident is a kind of the psychosocial stressors to person. The traffic accident-related patients may show the psychophysiologic hyperarousal. So we examined the differences of psychophysiologic response between patients with and without the memory of experienceing a traffic accident. Methods: Twenty-four traffic accident-related patients were divided into two groups according to ther memory of a traffic accident. In psychological assessment, levels of anxiety and depression were evaluated by State-Trait Anxiety Inventory, Beck's Depression Inventory, and Hamilton Rating Scales For Anxiety and Depression. Heart rate, electrodermal response (EDR), and electromyographic activity (EMG) were measured by biofeedback system, and systolic and diastolic blood pressure by automated vital sign monitor during baseline, task, and rest periods. We utilized script-driven imagery technique as a stressful task. The patients listened to the script describing their own traffic accident experience and were instructed to imagine the event during the task period. Statistically analytic data were obtained from the differences of psychological and psychophysiologic data between two groups. Results: The memory group did not show significantly higher EDR than the none memory group, but showed higher tendency during baseline, imagery, and rest periods. The memory group showed significantly lower EMG than the none memory group during rest period. However, there were no differences in other psychophysiologic reponses between the two groups. Conclusion: Our results showed that the memory group had higher tendency in autonomic arousal level such as electrodermal response than the none memory group. We suggest that physicians need to minimize repetitive imagery of traffic accident (reexperience), and decrease the autonomic hyperarousal in the treatment of traffic accident-related patients.

  • PDF

The Psychophysiologic Response in Korean Patients with Generalized Anxiety Disorder (범불안장애환자의 정신생리적 반응)

  • Chung, Sang-Keun;Hwang, Ik-Keun
    • Sleep Medicine and Psychophysiology
    • /
    • v.4 no.1
    • /
    • pp.107-119
    • /
    • 1997
  • Objectives: The psychophysiologic response pattern between healthy subjects and patients with generalized anxiety disorder, and the relationship among anxiety rating scales and those patterns in patients were examined. Methods: Twenty-three patients with generalized anxiety disorder(AD) and 23 healthy subjects were evaluated by Hamilton Rating Scale for Anxiety(HRSA) and State-Trait Anxiety Inventory before baseline stressful tasks. Subjective Units of Distress were evaluated just before baseline period, immediately after stressful tasks, at the end of the entire procedure, and psychophysiologic measures, i.e., skin temperature(ST), electromyographic activity(EMG), heart rate(HR), electrodermal response(EDR) during baseline & rest and during two psychologically stressful tasks (mental arithmetic, TM; talk about a stressful event, TT) were also evaluated. Results: 1) AD group showed significantly higher EMG level during rest after stressful tasks and higher HR level during all period except TM compared to control group. 2) AD group showed lower change in the startle response(SR) of ST, in the SR & the recovery response(RR) of EMG during TM, and in the RR of EDR immediately after TM than control group. AD group showed that the RR of EDR was significantly lower than the SR during stressful tasks. 3) We found that there was significantly negative correlation between state anxiety and the RR of EDR after TT in AD group. We also found that there were significantly positive correlations between HRSA score and the SRs of EDR during stressful tasks, and between state anxiety and the SR of EDR during TT. Conclusion: Our results suggest that patients with generalized anxiety disorder show higher autonomic arousal than healthy subjects and decreased physiologic flexibility or reduced autonomic flexibility.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.