• Title/Summary/Keyword: Electromechanical delay

Search Result 8, Processing Time 0.021 seconds

Computational Study to Understand the Cardiac Electromechanical Responses in LBBB and RBBB to the Application of CRT and LVAD

  • Heikhmakhtiar, Aulia Khamas;Lim, Ki Moo
    • Proceeding of EDISON Challenge
    • /
    • 2017.03a
    • /
    • pp.650-652
    • /
    • 2017
  • the aim of this study was to observe the combined effect of the CRT and LVAD on electromechanical cardiac behavior under LBBB and RBBB conditions computationally. We performed simulation by using advanced electromechanics model of failing ventricle combined with lumped model represents circulatory system, CRT and LVAD. We analyzed seven failing ventricle model including normal sinus rhythm, LBBB, LBBB coupled with CRT, LBBB coupled with CRT and LVAD, RBBB, RBBB coupled with CRT, and RBBB coupled with CRT and LVAD. We compared the effect from CRT and the effect from combined CRT and LVAD to both under LBBB and RBBB conditions. The results showed that the combined CRT and LVAD contributed a better hemodynamic compared to single CRT. This combined system synchronized the electrical activation greatly under LBBB and slightly under RBBB. It also shortened mechanical activation time which resulted short electromechanical delay. More importantly, the combined system produced better mechanical responses under both LBBB and RBBB conditions.

  • PDF

a study on the elastic wave delay line (탄성파 지정선에 관한 연구)

  • 김종상
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.6
    • /
    • pp.1-15
    • /
    • 1974
  • In this paper, the SH mode of elastic surface waves which are used for delay lines of elastic surface wave is the cretically analysed. It is shown that the SH mode has very large electromechanical coupling factor and propagates on the surface with very small decaying coefficient into the medium. In the case of P2T-4, the depth cf piezoelectric medium that contains 80% of energy is 190 wavelengths. An elastic surface wave delay line is discussed from the view point of 2-port network. Center frequency is shifted by the ratio of transducer electrode width to gap between transducer ellcerodes when electromechanical coupling factor is large. Tempera _ore coefficients for bulk waves of LiNbO3 and LiTaO3 are also calculated and the minimum temperature coefficient value of delay time is 5.4X 10-6/$^{\circ}C$ ia the case of transverse wave propagating along Z axis on LiTaO3. Experimental data are in good agreement with theoretical values of the temperature coefficients of delay time for elastic surface waves propagating along X axis of 130$^{\circ}$ and 64$^{\circ}$ rotated Y cut planes of the LiNbO3.

  • PDF

Characteristic Test of the Electro Mechanical Brake Actuator for Urban Railway Vehicles (도시철도용 전기기계식 제동장치의 특성시험)

  • Kim, Min Soo;Oh, Seh Chan;Kwon, Seok Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.7
    • /
    • pp.535-540
    • /
    • 2016
  • The braking device in railway vehicles decelerates or stops the train by dissipating the thermal energy converted from kinetic energy into the air. Therefore, the brake system is crucial for safety. In this paper, we performed a study on an electromechanical brake actuator using an electrical motor as an alternative to pneumatic air cylinders to reduce the idle running time in braking, which subsequently increases braking distance, and to ensure reliable response characteristics. Especially, to analyze the response characteristics of the electromechanical brake actuator, we measure the delay time, response time and power consumption compared to the air cylinder. It is confirmed that the electromechanical brake actuator can reduce reaction time by 0.1 seconds (Braking Action) and 0.46 seconds (Brake Release) compared to the air cylinder.

Comparison of Reaction Times of Ankle Joint Muscles in the Elderly Men and Women (고령자 남녀의 발목관절 근육 반응시간의 비교)

  • Kim, Ji-Won;Jeong, Hong-Young;Kim, Hyo-Hee;Kwon, Yu-Ri;Eom, Gwang-Moon;Lee, Jeong-Whan;Kim, Kyung-Seoup;Jun, Jae-Hoon;Park, Byung Kyu
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.163-168
    • /
    • 2012
  • Elderly women are reported to have greater risk of falls. The purpose of this paper was to investigate the possible gender differences in the reaction performance of ankle joint muscles, which have dominant role in the control of sagittal plane balance. Twenty-six elderly men and women with comparable mean age participated in this study. Reaction times to the audible beeps were measured in the tibialis anterior muscle and gastrocnemius muscle. Reaction time variables included premotor time, electromechanical delay and total reaction time. Gender difference in each reaction time was investigated by independent t-test. In both muscles, premotor time was longer in men but the electromechanical delay was longer in women (p < 0.05). Resulting total reaction time was longer in men in tibialis anterior muscle (p < 0.01) and it tended to be longer in men also in gastrocnemius muscle (p = 0.25). The results demonstrates that the overall reaction performances of elderly women is better than or comparable to those of elderly men in ankle joint muscles. This suggests that the reaction performance of ankle muscles is hardly the cause of the greater risk of falls in elderly women.

Surface Acoustic Wave Characteristics of PSS-PZT Cermaics with Cr addition (Cr 첨가에 따른 PSS-PZT 세라믹스의 탄성 표면파 특성)

  • 홍재일;유주현;김준한;강진규;박창엽
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.68-72
    • /
    • 1991
  • In this study, to improve temperature stability 0.05 Pb(Sn$\_$$\frac{1}{2}$/Sb$\_$$\frac{1}{2}$/O$_3$ - 0.35PbTiO$_3$ - 0.60PbZrO$_3$ + 0.4[wt%]MnO$_2$ piezoelctric oeramics of low dielectric constant and large mechanical quality factor were manufactured with the addition of Cr$_2$O$_3$by Hot Press method. And the SAW delay line was fabricated and the propagation characteristics of SAW was investigated, and the SAW filter was fabricated on C4 added by 0.2[wt%] Cr$_2$O$_3$and its frequency characteristics was investigated. The specimen, whose propagation characteristics of surface acoustic wave were the best, was C4 added by 0.2[wt%] Cr$_2$O$_3$, and its electromechanical coupling factor(ks$^2$) was 3.11[%] and its temperature coefficient of the center frequency (C$\_$fo/) was -21.27[ppm/$^{\circ}C$]. The 31[MHz] SAW IF filter of C4 scarcely had diffraction phenomena and its group delay time was 1.4673 ${\pm}$40[ns] in the pass band, and the insertion loss was -24.419[dB] on no impedance matching.

A Bursty Traffics Friendly MAC Protocol in Wireless Sensor Networks (무선센서 네트워크에서 버스티 트래픽에 적합한 MAC 프로토콜)

  • Lee, Jin-young;Kim, Seong-cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.5
    • /
    • pp.772-778
    • /
    • 2018
  • Due to the recent advances in computing, communication and micro-electromechanical technology, Wireless Sensor Networks (WSNs) applications have been extended from military to many commercial areas such as object tracking, wire detection, and vehicular sensor networks. In some applications bursty data from many sensor nodes may be generated and the generated data from the monitoring area may be sent in a limited time to the final destination, sink node. In this paper, we present a BTF-MAC protocol adequate for WSNs applications in which bursty data packets are required to be transmitted in a limited time. The BTF-MAC is a synchronous duty-cycle MAC protocol and uses a slot-reserved and operational period extension mechanism adapted to the traffics. Our numerical analysis and simulation results show that BTF-MAC outperforms other related protocols such as DW-MAC and SR-MAC in terms of energy consumption and transmission delay.

Effects of Different Types of Attentional Focus on Dart Throwing Mechanics (주의 집중 방법이 다트 던지기 역학에 미치는 영향)

  • Kim, Hye-Ree;Kong, Se-Jin;Kim, Soo-Yeon;Lee, Ki-Kwang
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.4
    • /
    • pp.327-333
    • /
    • 2013
  • The purpose of this study was to investigate the effects of different types of attentional focus(internal focus vs. external focus) on the dart throwing mechanics. Seven expert dart throwing athletes were assigned to an internal focus group and other seven athletes were assigned to an external focus group. Each group was asked to throw dart either under verbal instruction or without instruction. During dart throwing, accuracy(radial error), consistency(bivariate variable error), dart velocity, acceleration, elbow joint ROM, elbow joint angular velocity, EMD(electromechanical delay), iEMG of biceps brachii and triceps brachii, and CI(coactivation index) were collected and analyzed. Nither instruction type nor instruction itself affected in accuracy and consistency. However, in dart velocity and acceleration, there was an interaction between instruction and attentional focus types. Velocity and acceleration increased in the internal condition, where as they decreased in the external condition. The ROM of elbow joint did not affected by instruction and attention type. However, similar to dart velocity and acceleration, angular velocity increased in internal focus group, while it decreased in external focus group. EMG showed no difference with any condition. In conclusion, internal focus is better than external focus for dart throwing.

The Influences of Pulsed Electromagnetic Field Treatment Following Experimentally Induced Delayed-Onset Muscle Soreness in Biceps Brachii (펄스자기장이 위팔 두갈래근의 지연성 근육통에 미치는 영향)

  • Kang, Sun-Young;Park, Joo-Hee;Jeon, Hye-Seon;Lee, Hyun-Sook
    • Physical Therapy Korea
    • /
    • v.20 no.2
    • /
    • pp.11-19
    • /
    • 2013
  • Delayed onset muscle soreness (DOMS) is a painful condition that arises from exercise-induced muscle damage after unaccustomed physical activities. Various therapeutic interventions have been applied to reduce the intensity and duration of DOMS-related symptoms. Recently, pulsed electromagnetic field (PEMF) intervention has been introduced as an alternative noninvasive treatment for DOMS. This randomized, double-blind, placebo-controlled experiment was conducted to examine the effects of PEMF therapy on DOMS in elbow flexors at 24, 48, and 72 hours after the experimental DOMS induction. Thirty healthy volunteers ($23{\pm}2.4$ yrs, $175{\pm}5.7$ cm, and $74{\pm}7.8$ kg) participated in this study. Each was randomly assigned to a PEMF or placebo group. On the first day, DOMS was induced in the elbow flexors by repeated isokinetic motions at low ($60^{\circ}/s$) and fast ($120^{\circ}/s$) speeds in all subjects. Thereafter, the PEMF group received 15-min daily treatment with a PEMF device. The placebo group received sham treatment of the same duration. Overall, PEMF application was more effective than the sham treatment in reducing the physiological symptoms associated with the DOMS including perceived soreness, median frequency, and electromechanical delay of the surface electromyography. In addition, median frequency and isokinetic peak torque of the PEMF group recovered to the pre-DOMS induction level earlier than the placebo group. In conclusion, this study suggests that PEMF can be applied as a new recovery strategy in reducing DOMS symptoms. Further experiments are required to examine the effect of the PEMF treatment on different types of exercise conditions and to determine the optimal treatment dosage and duration in a real clinical setting.